Ht-Lt Electrification Works And Augmentation Of Power System /Modernisation Of Mill Ht/Lt Electrification Works And Augmentation Of Power System /Modernisation Of Mill
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Jun 2021
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
TCSM LTD → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Ht-Lt Electrification Works And Augmentation Of Power System / Modernisation Of Mill Ht / Lt Electrification Works And Augmentation Of Power System / Modernisation Of Mill
BOQ
| Name of Work: HT/LT ELECTRIFICATION WORKS AND AUGMENTATION OF POWER SYSTEM /MODERNISATION OF MILL | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | H T INSTALLATION [11kV INCOMING AND OUT GOING PANELS- 3PANEL VCB & BUS PT]: Design, fabrication, supply, installation, testing and Commissioning of 11kV VCB panel as per the scope of work, technical specification and drawing. The panel comprises of following major components. 11 kV, 800 A, 350MVA (3 sec) VCB - 3Nos. [1-I/C from Grid Supply and 2 O/Gs to 2Nos 800kVA OCTC ONAN Existing Transformers] Numerial protection relays having Modbus connectivity Digital power analyser/meter having RS 485 communication facilities Analog meters, control MCB, indication lamps, annuunciator, Hooters etc. Panel lighting (LED lamp) and panel heater with temperature control thermostat. Current density of aluminium busbar: 0.8 Amps/Sq.mm. The control supply voltage is 30V DC. [REFER Technical specification and SLDs] | El-1 | 1 | SET |
| 2 | 2 | 30V DC BATTERY, BATTERY CHARGER AND DC DB.: Supply,Installation, Testing & Commissioning of indoor,floor mounted 30V DC power supply system with 50Amps rated float and boost type battery charger, 15 nos. of 2Volt, 160AH (minimum) stationary type SMF VRLA batteries on a suitable stand. Battery charger shall be suitable for 3 Phase, 415V , 50Hz ,ac input and shall be capable of delivering continuous load of 50A, complete with DC DB Panel having 50A DP MCB as incomer and 6 nos: 25A DP MCB's as outlets. [REFER Technical specification and SLDs] VCB & VCB Panel shall be Manufacturede by Approved VCB Manufacturer; Siemens, ABB, L&T, Schneider] | El-2 | 1 | SET |
| 3 | 3 | 11kV CABLES AND CABLING:- Supply, Laying/ clamping testing and commissioning of the following HT Cable with Stranded compact circular ALUMINIUM conductor, conductor screened with Extruded semiconducting compound, XLPE Insulated, Insulation Screened with Extruded semiconducting compound in combination with Copper Tape, Aluminium Flat Strip / Round Wire armoured, and overall PVC ST2 Sheathed cable Conforming to IS:7098 Part-II 2011 with latest amendments. 3C X 300 SQ.MM. HT cable | El-3 | 165 | MTR |
| 4 | 4 | H T CABLE TERMINATIONS: Supply and providing end termination for the following sizes of HT XLPE cables including all materials required for frim joints. (Heat shrinkable type, Raychom/ M Seal Make)----- 3Cx300SQMM OUTDOOR | El-4 | 1 | Each |
| 5 | 5 | 3Cx300SQMM INTDOOR | El-5 | 5 | Each |
| 6 | 6 | EMERGENCY OFF PUSH BUTTON:- Supply, Installation ,testing and commissioning of Lockable Push Button for Emergency OFF facility of the HT VCB Panel for the Incomer VCB. [Cable shall also be included, Out side Trfo Room-1, Out side Trfo Room-2 & I/C VCB] | El-6 | 3 | Each |
| 7 | 7 | OUT DOOR CT/PT UNITS FOR SUPPLIERS METERING: Supply, installation, testing and commissioning of 11kV outdoor type CT/PT unit with, class 0.2S, 15VA CT with suitable ration as required as per KSEBL and 11kV/110V class 0.2S, 150VA PT on the existing DP structure with all necessary accessories for connecting 11kV lines, control cable, etc. as required. The existing CT PT Unit, Metering KIOSK and control cable shall be dismantled from the structure and stacked in stores as directed by the engineer incharge/ consultant. The Unit shall be duly tested at the TMR section of KSEB and the certificates should be submitted to the concerneed authorities for obtaining HT supply/ Regularised, as required. | El-7 | 1 | Each |
| 8 | 8 | TOD METER - SUPPLIERS METERING]:- Supply, Installation ,testing and commissioning of a TOD meter for KSEB within HT Metering panel including connections from CT and PT etc. as per KSEB/ Suppliers recommendation. The Meter shall be duly tested at the TMR section of KSEB and the certificates should be submitted to the concerneed authorities for obtaining HT supply, as required. [Make L&T; Trivector Meter Class 0.2s, Model ER300P Class 0.2s (Base Mounting) OR Equivalent. All statutory chargers shall be reimbursed from clients on production of proper receipts. | El-8 | 1 | Each |
| 9 | 9 | TOD METER KIOSK [OUTDOOR]:- Supply, Installation, testing and commissioning of HT Out door Metering KIOSK/Panel with glass window and sufficient number of terminal connectors with 25% spares, for connections from CT and PT etc. as per KSEB/ Suppliers recommendation, Control fuses, etc. The KIOSK shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54, weather proof, with rain guard, undergone seven tank process, powder coated finish, earthing, entire civil work including suitable foundation and all mounting accessories as required complete as per the rquirement of KSEBL. | El-9 | 1 | Each |
| 10 | 10 | M. V PANELS/ DISTRIBUTION BOARDS- SSB#01 & SSB#01 Refer SLDs and Technical Specifications | El-10 | 2 | SET |
| 11 | 11 | SSB-03 (DRAWING) Refer SLDs and Technical Specifications | El-11 | 1 | SET |
| 12 | 12 | SSB-04 AND SSB-05 (SIMPLEX) Refer SLDs and Technical Specifications | El-12 | 2 | SET |
| 13 | 13 | SSB-06 (COMBER) Refer SLDs and Technical Specifications | El-13 | 1 | SET |
| 14 | 14 | MCC-A AND MCC-B (HUMIDIFICATION PLANT FOR SPG-I&II) Refer SLDs and Technical Specifications | El-14 | 2 | SET |
| 15 | 15 | MCC-C (EXHAUST PLANT FOR SPG-I,II&III) Refer SLDs and Technical Specifications | El-15 | 1 | SET |
| 16 | 16 | MCC-D (EXHAUST PLANT FOR SPG-IV&V) Refer SLDs and Technical Specifications | El-16 | 1 | SET |
| 17 | 17 | MCC-E (SUPPLY&EXHAUST PLANT FOR PREPARATORY) Refer SLDs and Technical Specifications | El-17 | 1 | SET |
| 18 | 18 | MCC-F (SUPPLY&EXHAUST PLANT FOR POST SPG) Refer SLDs and Technical Specifications | El-18 | 1 | SET |
| 19 | 19 | REPAIRING OF LT PANELS Supply of all necessary materials and carrying out repaire and maintenance works of the following LT panels [Existing] as shown in the One Line Diagrams including cleaning, priming, spray painting with required colour [Grey], replacing of Bus Bar insulators/ SMC Supports [Pillar Type/ Finger Type], PVC Sleeves etc. as required and testing and commissioning. All panels boards shall be tested at site [SAT] and ensure all the values are sufficient and satifactory as per standards and requirements at the point of electrical safety rules as per CEA regulations/ KSEI Guidelines/ Orders and shall be recorded in presents of the Engineer in Charge/ Consultant. ------- MSB [MAIN MV PANEL-DOUBLE BUS PANEL] | El-19 | 1 | SET |
| 20 | 20 | PCC-1 | El-20 | 1 | SET |
| 21 | 21 | PCC-2 | El-21 | 1 | SET |
| 22 | 22 | PCC-3 | El-22 | 1 | SET |
| 23 | 23 | PCC-4 | El-23 | 1 | SET |
| 24 | 24 | PCC-5 | El-24 | 1 | SET |
| 25 | 25 | PCC-6 | El-25 | 1 | SET |
| 26 | 26 | PCC-7 | El-26 | 1 | SET |
| 27 | 27 | PCC-8 | El-27 | 1 | SET |
| 28 | 28 | PCC-9 | El-28 | 1 | SET |
| 29 | 29 | PCC-9-A | El-29 | 1 | SET |
| 30 | 30 | PCC-10 | El-30 | 1 | SET |
| 31 | 31 | BUS DUCT 2000A, 4POLE, 415V. | El-31 | 20 | Mtr |
| 32 | 32 | RETROFITTING DAMAGED SWITCHGEARS/ COMPONENTS.: Supply, installation, testing and commissioning of the following switch gears with in the existing LT Panel Boards including cecessary cutting, drilling, extension of Bus Bars, Interconnections etc. as required as per standards complete. The scope also includes dismantling and stacking of existing damages switches/ bus bars etc. as directed by the Engineer in Charge/ Consultant. ---- 400A TPN Isolators | El-32 | 2 | Each |
| 33 | 33 | 315A TPN Switch Fuse Units | El-33 | 1 | Each |
| 34 | 34 | 250A TPN Switch Fuse Units | El-34 | 4 | Each |
| 35 | 35 | 100A TPN Switch Fuse Units | El-35 | 6 | Each |
| 36 | 36 | 63A TPN Switch Fuse Units | El-36 | 4 | Each |
| 37 | 37 | Heavy Duty APP Capacitors of Different ratings with in the APFC Panel | El-37 | 250 | kVAR |
| 38 | 38 | HRC FUSE LINKS: Supply, installation, testing and commissioning of the following rating HRC Fuse Links DIN Type [Bolted Type for lower rating] suitable for 315A/ 250A/100A/63A SFUs with in the existing Panel Boards/ Switchgears. The Fuse links shall be provided as per the Standards and requirements of the Scheme Approval from the Department of Electrical Inspectorate in order to achieve Grading in between sections. The scope also includes dismantling and stacking of existing damages FUSE LINKS as directed by the Engineer in Charge/ Consultant. 400A | El-38 | 3 | Each |
| 39 | 39 | 300A/315A | El-39 | 30 | Each |
| 40 | 40 | 250A | El-40 | 3 | Each |
| 41 | 41 | 200A | El-41 | 6 | Each |
| 42 | 42 | 160A | El-42 | 36 | Each |
| 43 | 43 | 150A | El-43 | 36 | Each |
| 44 | 44 | 125A | El-44 | 33 | Each |
| 45 | 45 | 120A | El-45 | 21 | Each |
| 46 | 46 | 100A | El-46 | 9 | Each |
| 47 | 47 | 80A | El-47 | 72 | Each |
| 48 | 48 | 63A | El-48 | 3 | Each |
| 49 | 49 | 50A | El-49 | 3 | Each |
| 50 | 50 | 40A/35A | El-50 | 6 | Each |
| 51 | 51 | 25A | El-51 | 3 | Each |
| 52 | 52 | 2A [Control Fuses] | El-52 | 60 | Each |
| 53 | 53 | METERS AND INSTRUMENTS: Supply, installation, testing and commissioning of the following instruments/ Cast Resin CTs/ panel accessories with in the existing Panel Boards. The CTs shall be provided as per the Standards and requirements of the Scheme Approval from the Department of Electrical Inspectorate. The scope also includes dismantling and stacking of existing damages CTs/ Components Etc. as directed by the Engineer in Charge/ Consultant. --- RYB/ Trip Indication Lamps LED | El-53 | 48 | Each |
| 54 | 54 | Cast Resin CTs 1250/5A, Class 05, 10VA | El-54 | 6 | Each |
| 55 | 55 | Cast Resin CTs 400/5A, Class 05, 10VA | El-55 | 39 | Each |
| 56 | 56 | Cast Resin CTs 300/5A, Class 05, 10VA | El-56 | 3 | Each |
| 57 | 57 | 25A HRC Fuse Units [Control Fuses] | El-57 | 60 | Each |
| 58 | 58 | Digital Combination Meters V,A,F,PF, kVA, PF & kWhr | El-58 | 2 | Each |
| 59 | 59 | Digital Combination Meters V,A & F | El-59 | 14 | Each |
| 60 | 60 | Analogue Ammeters [0-1250A] | El-60 | 6 | Each |
| 61 | 61 | Analogue Volt meters [0-500V] | El-61 | 2 | Each |
| 62 | 62 | Volt Meter Selector Switches | El-62 | 2 | Each |
| 63 | 63 | Mechanical Interlocks between Switchgears | El-63 | 10 | Set |
| 64 | 64 | LOCAL ISOLATION FOR MOTORS/ EQUIPMENTS:- Supply, Installation, Testing and commissioning of Lockable OFF PBs with in suitable Sheet Steel Powder coated enclosures complete. | El-64 | 20 | Each |
| 65 | 65 | Supply, Installation, Testing and commissioning of 32A TP Isolators, MCB Type with in suitable Sheet Steel Powder coated enclosures complete. | El-65 | 12 | Each |
| 66 | 66 | Supply, Installation, Testing and commissioning of 63A TP Isolators, MCB Type with in suitable Sheet Steel Powder coated enclosures complete. | El-66 | 4 | Each |
| 67 | 67 | POWER FACTOR IMPROVEMENT CAPACITORS: Supply, Installation, Testing and commissioning of the following ratings Heavy Duty, APP Capacitors with in suitable Sheet Steel Powder coated enclosures, and giving connections as direct connection near by Motors/ Equipments, complete. --- 15kVAR | El-67 | 20 | Each |
| 68 | 68 | 10kVAR | El-68 | 6 | Each |
| 69 | 69 | LT CABLES AND CABLING:- Supply, laying, Testing and Commissioning of the following sizes of 650/1100 Volts Power/ Control Cables with Aluminium/ Copper Conductor (Solid up to 10 sqmm and Stranded for balance), XLPE Insulated, Cores Laid Up, Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. The cables shall be laid in cable trenches or on wall or through pipes as per specifications, including providing of cable route makers in every 50M and at all strategic turning/ diversion points [if burried Directly in ground], etc. Necessary clamping should be providing while burying cables in prepared trenches etc.as per standards. ALUMINIUM CONDUCTOR POWER CABLE --- 3.5x240 Sq.mm | El-69 | 460 | MTR |
| 70 | 71 | 3.5x185 Sq.mm AL Armoured | El-71 | 448 | MTR |
| 71 | 72 | 3.5x150 Sq.mm AL Armoured | El-72 | 15 | MTR |
| 72 | 73 | 3.5x50Sq.mm AL Armoured | El-73 | 10 | MTR |
| 73 | 74 | 3.5x35Sq.mm AL Armoured | El-74 | 10 | MTR |
| 74 | 75 | 3.5x25Sq.mm AL Armoured | El-75 | 10 | MTR |
| 75 | 76 | 3.0x25Sq.mm AL Armoured | El-76 | 110 | MTR |
| 76 | 77 | 4.0x16Sq.mm AL Armoured | El-77 | 10 | MTR |
| 77 | 78 | 3.0x16Sq.mm AL Armoured | El-78 | 270 | MTR |
| 78 | 79 | 4.0x10Sq.mm AL Armoured | El-79 | 20 | MTR |
| 79 | 80 | 3.0x10Sq.mm AL Armoured | El-80 | 310 | MTR |
| 80 | 81 | 4.0x6Sq.mm AL Armoured | El-81 | 10 | MTR |
| 81 | 82 | 3.0x6Sq.mm AL Armoured | El-82 | 186 | MTR |
| 82 | 83 | COPPER CONDUCTOR POWER CABLE --- 3.5x120 Sq.mm | El-83 | 465 | MTR |
| 83 | 84 | 3.5x95 Sq.mm - Cu Armoured | El-84 | 1 | MTR |
| 84 | 85 | 3.5x70Sq.mm - Cu Armoured | El-85 | 565 | MTR |
| 85 | 86 | 3.5x25Sq.mm - Cu Armoured | El-86 | 264 | MTR |
| 86 | 87 | 4.0x16Sq.mm - Cu Armoured | El-87 | 48 | MTR |
| 87 | 88 | 4.0x4Sq.mm - Cu Armoured | El-88 | 5 | MTR |
| 88 | 89 | 3.0x4Sq.mm - Cu Armoured | El-89 | 35 | MTR |
| 89 | 90 | 4.0x2.5Sq.mm - Cu Armoured | El-90 | 165 | MTR |
| 90 | 91 | 3.0x2.5Sq.mm - Cu Armoured | El-91 | 600 | MTR |
| 91 | 92 | COPPER CONDUCTOR CONTROL CABLE 16.0x1.5Sq.mm | El-92 | 74 | MTR |
| 92 | 93 | 12.0x1.5Sq.mm - Cu Armoured | El-93 | 246 | MTR |
| 93 | 94 | 10.0x1.5Sq.mm - Cu Armoured | El-94 | 45 | MTR |
| 94 | 95 | 8.0x1.5Sq.mm - Cu Armoured | El-95 | 96 | MTR |
| 95 | 96 | 7.0x1.5Sq.mm - Cu Armoured | El-96 | 32 | MTR |
| 96 | 97 | 6.0x1.5Sq.mm - Cu Armoured | El-97 | 38 | MTR |
| 97 | 98 | 4.0x1.5Sq.mm - Cu Armoured | El-98 | 128 | MTR |
| 98 | 99 | 3.0x1.5Sq.mm - Cu Armoured | El-99 | 1 | MTR |
| 99 | 100 | 2.0x1.5Sq.mm - Cu Armoured | El-100 | 1 | MTR |
| 100 | 101 | 3Cx0.75sQ.mm Copper Shielded Cable | El-101 | 90 | MTR |
| 101 | 102 | CABLE TERMINATIONS- ALUMINIUM CONDUCTOR POWER CABLE:- Supply and providing end terminations using siemens type compression gland for PVC insulated and PVC sheathed armoured conductor cable 1.1KV grade for the followings sizes including earthing the glands as required as per standards.--- 3.5x240 Sq.mm | El-102 | 14 | Each |
| 102 | 103 | 3.5x185 Sq.mm | El-103 | 24 | Each |
| 103 | 104 | 3.5x150 Sq.mm | El-104 | 2 | Each |
| 104 | 105 | 3.5x50Sq.mm | El-105 | 2 | Each |
| 105 | 106 | 3.5/3.0x35Sq.mm | El-106 | 2 | Each |
| 106 | 107 | 3.5x25Sq.mm | El-107 | 2 | Each |
| 107 | 108 | 3.0x25Sq.mm | El-108 | 8 | Each |
| 108 | 109 | 4.0x16Sq.mm | El-109 | 2 | Each |
| 109 | 110 | 3.0x16Sq.mm | El-110 | 16 | Each |
| 110 | 111 | 4.0x10Sq.mm | El-111 | 1 | Each |
| 111 | 112 | 3.0x10Sq.mm | El-112 | 8 | Each |
| 112 | 113 | 4.0x6Sq.mm | El-113 | 1 | Each |
| 113 | 114 | 3.0x6Sq.mm | El-114 | 12 | Each |
| 114 | 115 | CABLE TERMINATIONS- COPPER CONDUCTOR POWER CABLE --3.5x120 Sq.mm | El-115 | 18 | Each |
| 115 | 116 | 3.5x95 Sq.mm | El-116 | 2 | Each |
| 116 | 117 | 3.5x70Sq.mm | El-117 | 2 | Each |
| 117 | 118 | 4.0x25Sq.mm | El-118 | 14 | Each |
| 118 | 119 | 4.0x16Sq.mm | El-119 | 2 | Each |
| 119 | 120 | 4.0x4Sq.mm | El-120 | 2 | Each |
| 120 | 121 | 3.0x4Sq.mm | El-121 | 2 | Each |
| 121 | 122 | 4.0x2.5Sq.mm | El-122 | 16 | Each |
| 122 | 123 | 3.0x2.5Sq.mm | El-123 | 48 | Each |
| 123 | 124 | CABLE TERMINATIONS- COPPER CONDUCTOR CONTROL CABLE --16.0x1.5Sq.mm | El-124 | 4 | Each |
| 124 | 125 | 12.0x1.5Sq.mm | El-125 | 8 | Each |
| 125 | 126 | 10.0x1.5Sq.mm | El-126 | 2 | Each |
| 126 | 127 | 8.0x1.5Sq.mm | El-127 | 4 | Each |
| 127 | 128 | 7.0x1.5Sq.mm | El-128 | 2 | Each |
| 128 | 129 | 6.0x1.5Sq.mm | El-129 | 2 | Each |
| 129 | 130 | 4.0x1.5Sq.mm | El-130 | 8 | Each |
| 130 | 131 | 3.0x1.5Sq.mm | El-131 | 2 | Each |
| 131 | 132 | 2.0x1.5Sq.mm | El-132 | 2 | Each |
| 132 | 133 | 3Cx0.75sQ.mm Copper Shielded Cable | El-133 | 2 | Each |
| 133 | 134 | GENERAL EARTHING BARE COPPER EARTHING CONDUCTORS:- Supply, Laying/ fixing of earthing conductor with Purity not less than 99% of the following sizes/ type, jointing as per IS:3043/87 in trench walls pulling through pipes etc.as required. All joints in the system shall be braced properly with lead. 50x6 mm Copper Strip | El-134 | 560 | MTR |
| 134 | 135 | 40x6 mm Copper Strip | El-135 | 360 | MTR |
| 135 | 136 | 31x6 mm Copper Strip | El-136 | 470 | MTR |
| 136 | 137 | 25x3 mm Copper Strip | El-137 | 530 | MTR |
| 137 | 138 | Copper wire No.4 SWG | El-138 | 310 | MTR |
| 138 | 139 | Copper wire No.10 SWG | El-139 | 1700 | MTR |
| 139 | 140 | MAINTENANCE OF EARTHING STATIONS: Supply of all necessary materials and carrying out repaire works of the existing stations including replacing of damaged bolts/ nuts/ washers/ bracing the ends, etc. and taking earth reading in presence of the EIC/ Consultant to obtain a satifactory value for each station, etc. complete. | El-140 | 10 | Each |
| 140 | 141 | MISCELLANEOUS ITEMS:- Supply and Fixing of FRAMED KEY ONE LINE DIAGRAM in A-1 Size with frame work and glass at desired locations including supply of all fixing materials as required and as directed by EIC/ Consultant. | El-141 | 2 | Each |
| 141 | 142 | Supply and fixing of standard Shock Treatment Chart with frame work and glass including supply of all fixing materials as required and as directed by EIC/ Consultant. | El-142 | 4 | Each |
| 142 | 143 | CABLE TRAYS/ SUPPORTS: Supply and Erection of Vertical/Horizontal type M.S. Cable Trays and cable supports fabricated out of M.S.Angles (ISA) and M.S. flats with sufficient width and Spacing between successive cross members and supported at adequate spacing. The cable trays and supports 'shall be painted with 2coats of Zinc chromate 'primer and 2coats of enamel paint. 25x25x6mm MS angles and 20x6mm MS flats shall be used for trays up to 450mm wide and 40x40x6mm MS angles and 20x6mm MS flats shall be used for trays up to 900mm wide. | El-143 | 1200 | KG |
| 143 | 144 | CIVIL WORKS: Excavtion of soil in all classes up to a depth of 750mm suitable for Cable Trench directly burrying and backfilling with excavated soil after laying of cable including supply and laying of bricks, sand cushioning, etc. as required as per the standards for cable laying. | El-144 | 12 | MTR |
| 144 | 145 | CT&PT METER TESTING: Transporting CT/PT units and TOD meter (11KV) to the testing laboratories of KSEB and obtaining the necessary certificates for approval and load sanction from power supply company. | El-145 | 1 | LS |
| 145 | 146 | TRANSFORMER PROTECTION CUM MAINTENANCE:- 'Supply and Providing protection Class, Cast Resin, CTs suitable for REF Protection Relay [4 CT Method], Class PS, 10VA with suitable ID and outer dimensions. | El-146 | 8 | Each |
| 146 | 147 | Supply and Providing protection Class, Cast Resin, CTs suitable for Low set E/F Protection Relay. The NCT provided in the Earthing conductor shall be provided with necessary control box and supports. | El-147 | 2 | Each |
| 147 | 148 | Supply and providing Buchholz Relay, Oil Temperature and Winding Temperature [high] Indicators [OTI&WTI], with marshaling box and provision for alarm trip at Primary Breaker. | El-148 | 2 | Set |
| 148 | 149 | Supply of all necessary materials, labour etc. and carrying out Over all maintenance for the Existing 800 kVA ONAN OCTC Transformer, replacement of full set Gasket, Breather, Cleaning, Primimg and Painting with approved cloour Epoxy Paint, etc. complete. Test certificates/reports shall also be issued after conducting all necessary routeen tests, through competent and approved agency. | El-149 | 2 | Set |
| 149 | 150 | Supply and Filling of Brand New Transformer Oil as per IS 335 of sufficient quantity for 800kVA ONAN Transformer, [740 Ltr] tested for BDV including draining out the old oil, cleaning and washing the tank etc. complete. | El-150 | 2 | Set |
| 150 | 151 | Supply and providing new Radiators (4nos) with dimensions of (1100mm x 520mm x 10 fins.). Butterfly valve (8nos) along with fasteners and all necessary accessories, pipes etc. This scope includes all necessary fabrication, assembling and including replacing the existing tank, comlete. | El-151 | 2 | Set |
| 151 | 152 | DOCUMENTS & APPROVAL- ELECTRICAL INSPECTORATE APPROVALS & SANCTION ORDERS: Preparation of all documents, applications, forms and conducting Soil resistivity tests, submission of Scheme, obtaining Scheme Approval, Conducting Electrical Inspection, as installaed drawings, obtaining Energisation Sanction Orders for the Entire Installation including installations/ equipments/ panels/ loads, etc. existing at the premises but to be regularised as per statutes, etc. complete. (Excluding statutory charges). | El-152 | 1 | LS |
| 152 | 153 | SUPPLY AUTHORITY CONNECTED LOAD/ CD REGULARISATION: 'Preparation of necessary documents, forms, drawings, schemes, certificates, submitting completion reports, Executing HT Supply Agreement, etc. and obtaining Power sanction/ additional Power Sanction service connection @ 11kV from KSEB for the installation. All statutory charges shall be remitted by the clients. | El-153 | 1 | LS |
AI Tender Summary
Tender Timeline
May 14, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedJun 07, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 08, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender