Irrigation And Flood Control Department-IFCD has published Comprehensive Annual Maintenance Contract ( Amc ) For Electrical Gadgets ( Motors And Starters ) Installed At Various Irrigation Cum Dewatering Scheme Fall Under The Mechanical Irrigation Division Shadipora For The Year 2020-21. Submission Date for this Tender is 20-05-2021. Starter Tenders in SHADIPORA Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-May-2021 | Date Corrigendum | Date | 20-05-2021 |
Name of Work: Comprehensive Annual Maintenance Contract (AMC) for Electrical Gadgets (motors and Starters) installed at various Irrigation Cum Dewatering scheme fall under the Mechanical Irrigation Division Shadipora for the year 2021-22 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Mechanical transportation, loading, unloading and stacking of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: | |||
2 | 2 | Private car, auto-rickshaw or similar with 1.0 km lead | 1 | trip | |
3 | 3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
4 | 4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
5 | 5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
6 | 6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
7 | 7 | Load carrier auto, mini van or similar with 1.0 km lead | 1 | trip | |
8 | 8 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
9 | 9 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
10 | 10 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
11 | 11 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
12 | 12 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead | 1 | trip | |
13 | 13 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
14 | 14 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
15 | 15 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
16 | 16 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
17 | 17 | Truck, tipper or similar with 1.0 km lead | 1 | trip | |
18 | 18 | Extra per kilometer for lead >1.0 kms upto 5.0 kms | 1 | km | |
19 | 19 | Extra per kilometer for lead >5.0 kms upto 10.0 kms | 1 | km | |
20 | 20 | Extra per kilometer for lead >10.0 kms upto 20.0 kms | 1 | km | |
21 | 21 | Extra per kilometer for lead >20.0 kms upto 30.0 kms | 1 | km | |
22 | 22 | Hiring of mobile crane upto 5 Ton capacity | 1 | day | |
23 | 23 | Hiring of hydraulic back hoe loader. | 1 | hour | |
24 | 24 | DISMANTLING AND ASSEMBLING\nMOTORS\nDisconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, carefully taking out the rotor from the stator, and completely disassembly as per requirement of job:\nupto 60 HP | 1 | job | |
25 | 25 | >60 upto 200 HP | 1 | job | |
26 | 26 | Complete assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load.\nupto 60 HP | 1 | job | |
27 | 27 | >60 upto 200 HP | 1 | job | |
28 | 28 | Repairs to Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of:\nDisconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load. | 1 | job | |
29 | 29 | Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of:\nIsolating the motor, dismantling of top end cover of the motor, removing of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load. | 1 | job | |
30 | 30 | Replacement of Driving End (DE) bearing of Vertical electric motor by way of:\nDisconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job excludes the cost of bearing\nupto 60 HP rating | 1 | job | |
31 | 31 | >60 upto 200 HP | 1 | job | |
32 | 32 | Replacement of Non Driving End (NDE) bearing of Vertical electric motor by way of:\nDisconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of non-reverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor.\nupto 60 HP rating | 1 | job | |
33 | 33 | >60 upto 200 HP | 1 | job | |
34 | 34 | Replacement of Driving End (DE) bearing of horizontal electric motor by way of:\nDisconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load.\nupto 60 HP rating | 1 | job | |
35 | 35 | >60 upto 200 HP | 1 | job | |
36 | 36 | Replacement of Non-Driving End (NDE) bearing of horizontal electric motor by way of:\nDisconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load.\nupto 60 HP rating | 1 | job | |
37 | 37 | >60 upto 200 HP | 1 | job | |
38 | 38 | STARTER\nIsolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. The Job excludes the cost of material\nupto 60 HP rating | 1 | job | |
39 | 39 | >60 upto 200 HP | 1 | job | |
40 | 40 | >200 HP upto 500HP | 1 | jon | |
41 | 41 | Fitting of autotransformer coil assembly in the starter oil tank, refilling of collected t.oil in the tank, reconnecting all leads and load testing of the starter.The Job excludes the cost of material\nupto 60 HP rating | 1 | job | |
42 | 42 | >60 upto 200 HP | 1 | job | |
43 | 43 | >200 HP upto 500HP | 1 | job | |
44 | 44 | Isolating and disconnecting of all incoming and outgoing leads from OISD starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged copper contactpoints from the starter. The Job excludes the cost of contact points\nupto 60 HP rating | 1 | job | |
45 | 45 | >60 upto 200 HP | 1 | job | |
46 | 46 | Fitting of copper contact points, refilling of collected t.oil in the tank, reconnecting all leads and load testing of the starter.The Job excludes the cost of copper contact points.\nupto 60 HP rating | 1 | job | |
47 | 47 | >60 upto 200 HP | 1 | job | |
48 | 48 | MOTORS\nComplete rewinding of stator coils of 3-phase LV horizontal/ vertical induction motor with suitable copper wire after complete removal of burnt out winding, cleaning of slots, etc., insulation class F, varnishing, tapping, etc. \n(Note: The unserviceable scrap copper windings extracted shall be property of the firm and is taken into account for estimation of rates).\n0.5 HP (single phase) | 1 | job | |
49 | 49 | 1 HP (single phase) | 1 | job | |
50 | 50 | 3 HP | 1 | job | |
51 | 51 | 5 HP | 1 | job | |
52 | 52 | 15 HP | 1 | job | |
53 | 53 | 15 HP (Submersible type) | 1 | job | |
54 | 54 | 25 HP | 1 | job | |
55 | 55 | 30 HP | 1 | job | |
56 | 56 | 40 HP | 1 | job | |
57 | 57 | 50 HP | 1 | job | |
58 | 58 | 60 HP | 1 | job | |
59 | 59 | 75 HP | 1 | job | |
60 | 60 | 90 HP(Large body & Low RPM) | 1 | job | |
61 | 61 | 100 HP | 1 | job | |
62 | 62 | 120 HP | 1 | Job | |
63 | 63 | 125 HP | 1 | Job | |
64 | 64 | 150 HP | 1 | job | |
65 | 65 | BEARINGS AND ALLIED\nProviding of new bearing as under: \n(Prefered makes: ZKL/ARB/NBC).\n3210 | 1 | no. | |
66 | 66 | 3212 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
67 | 67 | 3213 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
68 | 68 | 3309 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
69 | 69 | 3313 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
70 | 70 | 51310 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
71 | 71 | 51312 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
72 | 72 | 51314 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
73 | 73 | 51320 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
74 | 74 | 51322 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
75 | 75 | 51328 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
76 | 76 | 6014 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
77 | 77 | 6028 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
78 | 78 | 6217 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
79 | 79 | 6220 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
80 | 80 | 6305 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
81 | 81 | 6306 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
82 | 82 | 6307 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
83 | 83 | 6308 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
84 | 84 | 6309 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
85 | 85 | 6310 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
86 | 86 | 6311 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
87 | 87 | 6312 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
88 | 88 | 6313 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
89 | 89 | 6314 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
90 | 90 | 6315 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
91 | 91 | 6316 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
92 | 92 | 6318 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
93 | 93 | 6406 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
94 | 94 | 6408 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
95 | 95 | 6410 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
96 | 96 | 6411 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
97 | 97 | 6412 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
98 | 98 | 6415 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
99 | 99 | 6418 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
100 | 100 | 7220 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
101 | 101 | 7312 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
102 | 102 | N317 | 1 | no. | |
103 | 103 | NU 316 | 1 | no | |
104 | 104 | NU318 | 1 | no. | |
105 | 105 | NU322 | 1 | no. | |
106 | 106 | NU324 | 1 | no. | |
107 | 107 | 32309 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
108 | 108 | 32310 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
109 | 109 | 7318 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
110 | 110 | 6320 (Prefered makes: ZKL/ARB/NBC). | 1 | no. | |
111 | 111 | OIL IMMERSED MANUAL STAR DELTA STARTER/ DOL STARTER\nProviding, installation, testing and commissioning of (L&T/Bentex/Kilburn make). OISD Starter, mechanically operated, working on 450±10% AC voltage supply, 50HZ, working on star delta principle. The starter shall be fitted with heavy duty copper bush rods 6 nos. 3 for incoming and 3 no’s for outgoing, and auto tripping system. The starter shall be fitted with heavy duty copper points 24nos, both moving and fixed. The complete assembly shall be housed in a suitable container fabricated out of 14 gauge MS sheet with easy inspection cover. The starter shall be first filled with starter oil (upto required level) of high grade and low viscosity. The starter shall be mounted with nuts and bolts for proper fixing on panel board and tested on full load at site. \n100HP | 1 | Job | |
112 | 112 | 150 HP | 1 | Job | |
113 | 113 | 200 HP( Triple contact) | 1 | Job | |
114 | 114 | Providing, installation, testing and commissioning of dry type 10HP (L&T/Bentex/Kilburn make). DOL Starters, mechanically operated, working on 50Hz, 450±10% AC voltage supply for operation of priming units. The starter shall be mounted with nuts and bolts for proper fixing on pannel. | 1 | Job | |
115 | 115 | Repairs to upto 200 HP OISD Starter by way of complete dismantling of the starter & then replacement of; and then testing on full load \nReplacement of Long/fixed contact point as per sample | 1 | No | |
116 | 116 | Replacement of Short/movable contact point as per sample | 1 | No | |
117 | 117 | Replacement of damaged trip coil contact point as per sample | 1 | Job | |
118 | 118 | Replacement of copper bush rod as per sample | 1 | No | |
119 | 119 | Setting right of handle mechanism & Rettaping/ thimbling of the terminal connections | 1 | Job | |
120 | 120 | AUTOTRANSFORMER\nRewinding burnt/ damaged limb/s of autotransformer coil assembly (comprising of three limbs) of below specified rating using superior quality copper wire of proper gauge as per requirement with superior insulation, varnish, etc. \n(Note: The unserviceable scrap copper generated shall be property of the firm and is taken into account for estimation of rates).\n30 HP | 1 | limb | |
121 | 121 | 40 HP | 1 | limb | |
122 | 122 | 80 HP | 1 | limb | |
123 | 123 | 100 HP | 1 | limb | |
124 | 124 | 125 HP | 1 | limb | |
125 | 125 | 275 HP | 1 | limb | |
126 | 126 | 300 HP | 1 | limb | |
127 | 127 | 350 HP | 1 | limb | |
128 | 128 | 375 HP | 1 | limb | |
129 | 129 | 400 HP | 1 | limb | |
130 | 130 | 425 HP | 1 | limb | |
131 | 131 | CONTACTORS\nProviding and fitting of 3-pole contactor with specified coil voltage:\nL&T ML 1.5 | 1 | no. | |
132 | 132 | L&T ML 2 | 1 | no. | |
133 | 133 | L&T ML 3 | 1 | no. | |
134 | 134 | L&T ML 4 | 1 | no. | |
135 | 135 | L&T ML 6 | 1 | no. | |
136 | 136 | L&T ML 10 | 1 | no. | |
137 | 137 | L&T ML 12 | 1 | no. | |
138 | 138 | L&T MNX 50 | 1 | no. | |
139 | 139 | L&T MNX 70 | 1 | no. | |
140 | 140 | L&T MNX 80 | 1 | no. | |
141 | 141 | L&T MNX 95 | 1 | no. | |
142 | 142 | L&T MNX 110 | 1 | no. | |
143 | 143 | L&T MNX 140 | 1 | no. | |
144 | 144 | L&T MNX 185 | 1 | no. | |
145 | 145 | L&T MNX 225 | 1 | no. | |
146 | 146 | L&T MNX 250 | 1 | no. | |
147 | 147 | L&T MNX 325 | 1 | no. | |
148 | 148 | Schneider Electric LC1F115(without coil) | 1 | no. | |
149 | 149 | Schneider Electric LC1F150(without coil) | 1 | no. | |
150 | 150 | Schneider Electric LC1F185(without coil) | 1 | no. | |
151 | 151 | Schneider Electric LC1F265 (without coil) | 1 | no. | |
152 | 152 | Schneider Electric LC1F330 (without coil) | 1 | no. | |
153 | 153 | Schneider Electric LC1FDP400 (without coil) | 1 | no. | |
154 | 154 | Schneider Electric LC1F400 (without coil) | 1 | no. | |
155 | 155 | Schneider Electric LC1F630 (without coil) | 1 | no. | |
156 | 156 | Providing and fitting of new coil with specified coil voltage for contactors as under:\nL&T ML 2/ 3 | 1 | no. | |
157 | 157 | L&T ML 4/ 6 | 1 | no. | |
158 | 158 | L&T ML 10/ 12 | 1 | no. | |
159 | 159 | L&T MNX 50/ 70/ 80 | 1 | no. | |
160 | 160 | L&T MNX 95/ 110/ 140 | 1 | no. | |
161 | 161 | L&T MNX 185/ 225/ 250 | 1 | no. | |
162 | 162 | L&T MNX 300/325/ 400 | 1 | no. | |
163 | 163 | L&T MNX 550/ 650 | 1 | no. | |
164 | 164 | Schneider Electric LC1F115/LC1F150/LC1F185/ LC1F225 | 1 | no. | |
165 | 165 | Schneider Electric LC1F265/ LC1F330 | 1 | no. | |
166 | 166 | Schneider Electric LC1F400 | 1 | no. | |
167 | 167 | Schneider Electric LC1F630 | 1 | no. | |
168 | 168 | Providing and fitting of new Contact kit set for contactors\nL&T ML 2 | 1 | set | |
169 | 169 | L&T ML 3 | 1 | set | |
170 | 170 | L&T ML 4 | 1 | set | |
171 | 171 | L&T ML 6 | 1 | set | |
172 | 172 | L&T ML 10 | 1 | set | |
173 | 173 | L&T ML 12 | 1 | set | |
174 | 174 | Providing and fitting of auxillary/ control relay (L&T MX0 or similar) for AC control | 1 | no. | |
175 | 175 | Providing and fitting of auxillary/ control relay (L&T MN0 or similar) for DC control | 1 | no. | |
176 | 176 | Providing and fitting of (1NO+1NC) side mounting auxillary contact block (For L&T/ Schneider Electric make contactors). | 1 | no. | |
177 | 177 | Providing and fitting of front mounting auxillary contact block having 04 contacts (all combinations) (For L&T/ Schneider Electric make contactors) | 1 | no. | |
178 | 178 | TIMING RELAYS\nProviding, fitting and setting of electropneumatic (2NO + 2NC) double timing relay (BCH make or equivalent) with timing range upto 60s; coil voltage 415V AC. | 1 | no. | |
179 | 179 | Providing, fitting and setting of 240VAC Star Delta Timer delay ( within range from 3s - upto 120s) DIN mounted electronic timer relay (L&T or equivalent make) | 1 | no. | |
180 | 180 | Providing, fitting and setting of ON delay (0.3s - 60s or higher) DIN mounted electronic timer relay (GIC or equivalent make) | 1 | no. | |
181 | 181 | Providing, fitting and setting up of 240V synchronous ON delay timer (0.15 - 3.0min) (L&T/ GIC or equivalent make) | 1 | no. | |
182 | 182 | THERMAL OVERLOAD RELAY\nProviding, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN2) \nRelay range in between 0.2A to 15A | 1 | no. | |
183 | 183 | 14-23A | 1 | no. | |
184 | 184 | 20-33A | 1 | no. | |
185 | 185 | 24-40A | 1 | no. | |
186 | 186 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MN5)\n30-50A | 1 | no. | |
187 | 187 | 36-60A | 1 | no. | |
188 | 188 | 45-75A | 1 | no. | |
189 | 189 | 66-110A | 1 | no. | |
190 | 190 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T ML1) \nRelay range in between 0.15A to 16A | 1 | no. | |
191 | 191 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T ML2/3) \nRelay range in between 9A to 42A | 1 | no. | |
192 | 192 | Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots | 1 | sq. inch | |
193 | 193 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. | 1 | job | |
194 | 194 | Complete replacement of suitable copper control wiring of ATS including connections, tapping and insulation as per requirement. | 1 | job | |
195 | 195 | Providing and fitting 3 Phase, 3 Wire Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) | 1 | no. | |
196 | 196 | Providing and fitting auto reset Single Phasing Preventor (Minilec VSP 2 or equivalent) | 1 | no. | |
197 | 197 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) | 1 | no. | |
198 | 198 | Providing of HRC fuses (2A - 32A) ratings | 1 | no. | |
199 | 199 | Providing and fitting of Fuse holders for fuses upto 32A rating | 1 | no. | |
200 | 200 | Providing and fixing uPVC panel trunking with allied fittings\n15x15mm | 1 | mtr | |
201 | 201 | 25x25mm | 1 | mtr | |
202 | 202 | Providing and fitting of Terminal Block 100A - 3 way | 1 | no. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy