Eastern Coal Fields Ltd-ECL has published 655 . 5Mtr Shortening , 57Mtr Dismantling With Drive Head-Discharge Unit Of 62L Tandem Belt Conveyor And 769 . 5Mtr Shortening , 80Mtr Dismantling With Drive Head-Discharge Unit Of 62L Belt Conveyor At 3-4 Incline , Jpc And Salvaging Of Material As Pe. Submission Date for this Tender is 21-05-2021. Conveyors and Accessories Tenders in Underground of 3and4 Incline unit, JPC West Bengal. Bidders can get complete Tender details and download the document.
Name of Work: Works And Services | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Shortening of 655.5 mtr i.e. 23 pillars(one pillar at a time i.e 28.5 mtr) of 1000mm width 62L tandem belt conveyor from 43D to 20D in R-VIIA seam and salvaging them from panel-3 to (14XD-13XD)/57L in R-VIIA seam | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | Dismantling of 23 times tail end unit complete from 62L/43D to 62L/21D for 23 times 62L tandem belt shortening in R-VIIA seam. | BI01010001010000000000000515BI0100001113 | 21.735 | MT |
3 | 1.02 | Dismantling of 23 pillars i.e. 655.5mtr 1000 mm width belt structure from 62L/43D to 62L/20D for 23 times 62L tandem belt shortening in R-VIIA seam. Each time belt shortening for 1 pillar i.e 28.5 mtr | BI01010001010000000000000515BI0100001114 | 95.48 | MT |
4 | 1.03 | 23 times transportation and installation of this tail end unit complete from 62L/42D to 62L/20D for 23 times 62L tandem belt shortening in R-VIIA seam. | BI01010001010000000000000515BI0100001115 | 21.735 | MT |
5 | 1.04 | Unlapping & pulling out 1000mm width 1311mtr. belting for 23 pillars i.e 655.5mtr belt shortening of 62L tandem belt conveyor; then belt jointing; tensioning, tuning & trial run. Each time belt shortening for 1pillar i.e 28.5mtr. | BI01010001010000000000000515BI0100001116 | 1 | Work |
6 | 1.05 | Loading of 1311mtr dismantled 1000mm width belting & 655.5mtr dismantled 1000mm width belt structures of 62L tandem belt conveyor on trolly and salvaging them from panel-3 to (14XD-13XD)/57L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001117 | 1 | Work |
7 | 1.06 | Dismantling of 23 pillars i.e 655.5mtr of pull cords, communication devices, signalling wires etc. from 62L tandem belt conveyor at the time of 23times 62L tandem belt shortening and salvaging them from panel-3 to (14XD-13XD)/57L in R-VIIA seam. Each time belt shortening for 1pillar i.e 28.5mtr. | BI01010001010000000000000515BI0100001118 | 1 | Work |
8 | 2 | Dismantling of 57 mtr of 62L tandem belt with drive head, discharge unit, loop take up unit, tail end unit,belt structure, electricals etc from 20D to 18D in R-VIIA seam and salvaging them from panel-3 to (14XD-13XD)/57L in R-VIIA seam | BI01010001010000000000000515BI0100001119 | ||
9 | 2.01 | Dismantling of the 1000mm width, 1x110kW, 550V, single Drive Head unit Complete with Drive Drum, Driven Drum, Gear Box, Motor, Couplings, Bearing Blocks, baseplate, fencing etc. of 62L tandem belt conveyor from 19D/62L (R-VIIA). | BI01010001010000000000000515BI0100001120 | 5.31 | MT |
10 | 2.02 | Dismantling of the complete belt discharge unit with strike plate & chute plate of 1000mm width 62L tandem belt conveyor from 18D/62L (R-VIIA). | BI01010001010000000000000515BI0100001121 | 2.56 | MT |
11 | 2.03 | Dismantling of the complete loop take up unit of 1000mm width 62L tandem belt conveyor from 19D-20D/62L (R-VIIA). | BI01010001010000000000000515BI0100001122 | 2.5 | MT |
12 | 2.04 | Dismantling of the complete belt tail end unit with fencing & dust collector of 1000mm width 62L tandem belt conveyor from 20/62L(R-VIIA). | BI01010001010000000000000515BI0100001123 | 0.945 | MT |
13 | 2.05 | Dismantling of 57mtr. 1000mm width 62L belt tandem belt conveyor structure complete with stringer, foot stool, top Bracket, top roller, bottom roller, decking plate, scrapper etc from 62L/20D to 62L/18D in R-VIIA seam. | BI01010001010000000000000515BI0100001124 | 8.303 | MT |
14 | 2.06 | Unlapping & pulling out of 130mtr. 1000mm width PVC belting of 62L tandem belt conveyor from 62L/20D to 62L/18D in R-VIIA seam; Dismantling of pull cords with cable, communication devices with cable, signalling wire, bobbin insulators etc for a length of 57mtr. belt conveyor of 62L tandem belt from 62L/20D to 62L/18D in R-VIIA seam. | BI01010001010000000000000515BI0100001125 | 1 | Work |
15 | 2.07 | Salvaging these drive head unit, discharge unit, loop-take-up unit, tail end unit, 57mtr. 1000mm width belt structure, 130mtr. 1000mm belting, pull cords, communication devices, signalling wire etc. from this panel-3 to (14XD-13XD)/57L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001126 | 1 | Work |
16 | 2.08 | Salvaging of this 62L tandem belt starter, breaker, LS unit, winch starter, one 315kVA 6.6kV/550V TSU(at 20D/63L in R-VIIA) with one 6.6kV VCB, 100mtr. 70sq.mm. 3.3kV grade PVCDWA cable & 500mtr. 35sq.mm 6.6kV grade PVCDWA cable from this panel-3 to (14XD-15XD)/57L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001127 | 1 | Work |
17 | 3 | Shortening of 769.5 mtr i.e. 27 pillars (one pillar at a time i.e 28.5 mtr) of of 1000mm width 62L belt conveyor from 18D to 17XD in R-VIIA seam and salvaging them from panel-3 to (14XD-13XD)/58L in R-VIIA seam | BI01010001010000000000000515BI0100001128 | ||
18 | 3.01 | Dismantling of 27 times tail end unit complete from 62L/18D to 62L/-8D for 27 times 62L belt shortening in R-VIIA seam. | BI01010001010000000000000515BI0100001129 | 25.515 | MT |
19 | 3.02 | Dismantling of 27 pillars i.e. 769.5mtr 1000mm width belt structure from 62L belt conveyor from 62L/18D to 62L/17XD for 27 times 62L belt shortening in R-VIIA seam. Each time belt shortening for 1pillar i.e 28.5mtr. | BI01010001010000000000000515BI0100001130 | 112.09 | MT |
20 | 3.03 | 27 times transportation and installation of this tail end unit complete from 62L/17D to 62L/17XD for 27 times 62L belt shortening in R-VIIA seam. | BI01010001010000000000000515BI0100001131 | 25.515 | MT |
21 | 3.04 | Unlapping & pulling out 1000mm width 1539mtr. belting for 27 pillars i.e 769.5mtr belt shortening of 62L belt conveyor; then belt jointing; tensioning, tuning & trial run. Each time belt shortening for 1pillar i.e 28.5mtr. | BI01010001010000000000000515BI0100001132 | 1 | Work |
22 | 3.05 | Loading of 1539mtr dismantled 1000mm width belting & 769.5mtr dismantled 1000mm width belt structures of 62L belt conveyor on trolly and salvaging them from panel-3 to (14XD-13XD)/58L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001133 | 1 | Work |
23 | 3.06 | Dismantling of 27 pillars i.e 769.5mtr of pull cords, communication devices, signalling wires etc. from 62L belt conveyor at the time of 27times 62L belt shortening and salvaging them from panel-3 to (14XD-13XD)/58L in R-VIIA seam. Each time belt shortening for 1pillar i.e 28.5mtr. | BI01010001010000000000000515BI0100001134 | 1 | Work |
24 | 4 | Dismantling of 80mtr of 62L belt with drive head, discharge unit, loop take up unit, tail end unit,belt structure, electricals etc from 17XD to 15XD in R-VIIA seam and salvaging them from panel-3 to (14XD-13XD)/58L in R-VIIA seam | BI01010001010000000000000515BI0100001135 | ||
25 | 4.01 | Dismantling of the 1000mm width, 1x110kW, 550V, single Drive Head unit Complete with Drive Drum, Driven Drum, Gear Box, Motor, Couplings, Bearing Blocks, baseplate, fencing etc. of 62L belt conveyor from 16XD/62L (R-VIIA). | BI01010001010000000000000515BI0100001136 | 5.31 | MT |
26 | 4.02 | Dismantling of the complete belt discharge unit with strike plate & chute plate of 1000mm width 62L belt conveyor from 15XD/62L (R-VIIA). | BI01010001010000000000000515BI0100001137 | 2.56 | MT |
27 | 4.03 | Dismantling of the complete loop take up unit of 1000mm width 62L belt conveyor from (17XD-16XD)/62L (R-VIIA). | BI01010001010000000000000515BI0100001138 | 2.5 | MT |
28 | 4.04 | Dismantling of the complete belt tail end unit with fencing & dust collector of 1000mm width 62L belt conveyor from 17XD/62L (R-VIIA). | BI01010001010000000000000515BI0100001139 | 0.945 | MT |
29 | 4.05 | Dismantling of 80mtr. 1000mm width 62L belt conveyor structure complete with stringer, foot stool, top Bracket, top roller, bottom roller, decking plate, scrapper etc from 62L/17XD to 62L/15XD in R-VIIA seam. | BI01010001010000000000000515BI0100001140 | 11.65 | Nos |
30 | 4.06 | Unlapping & pulling out of 180mtr. 1000mm width PVC belting of 62L belt conveyor from 62L/17XD to 62L/15XD in R-VIIA seam; Dismantling of pull cords with cable, communication devices with cable, signalling wire, bobbin insulators etc for a length of 80mtr. belt conveyor of 62L belt from 62L/17XD to 62L/15XD in R-VIIA seam. | BI01010001010000000000000515BI0100001141 | 1 | Work |
31 | 4.07 | Salvaging these drive head unit, discharge unit, loop-take-up unit, tail end unit, 80mtr. 1000mm width belt structure, 180mtr. 1000mm belting, pull cords, communication devices, signalling wire etc. from this panel-3 to (14XD-13XD)/58L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001142 | 1 | Work |
32 | 4.08 | Salvaging of this 62L belt starter, breaker, LS unit, winch starter, 250mtr. 70sq.mm. 3.3kV grade PVCDWA cable from this panel-3 to (14XD-15XD)/57L in R-VIIA seam by the help of haulage. | BI01010001010000000000000515BI0100001143 | 1 | Work |
33 | 5 | Total impact of GST for the purpose of CTC | BI01010001010000000000000515BI0100001144 | 1 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail