Military Engineer Services-MES has published Ge ( P ) Af/Gur-22/2021-22 Repair/Maintenance Of Air Conditioning Plants , Air Conditioners , Refrigerators , Water Coolers And Other Cooling Appliances At 13 Brd , 16 Brd , 27Ed , 31 Mcu Of Af Stn Palam Under Ge ( P ) Af Gurgaon. Submission Date for this Tender is 03-06-2021. Air Conditioner Tenders in GE (P) AF Gurgaon Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-May-2021 | BOQ Corrigendum22 | BOQ | 27-05-2021 |
2 | 27-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-06-2021 |
3 | 27-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-06-2021 |
NAME OF WORK: REPAIR/MAINTENANCE OF AIR CONDITIONING PLANTS, AIR CONDITIONERS, REFRIGERATORS, WATER COOLERS AND OTHER COOLING APPLIANCES AT 13 BRD, 16 BRD, 27ED, 31 MCU OF AF STN PALAM UNDER GE (P) AF GURGAON | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1.01 | Supply and fixing in replacement of Galvanized Iron fly wheel gate valve size 50 mm complete all as specified and as directed by Engr In Charge. | BI01010001010000000000000515BI0100001113 | 2 | Each |
2 | 2 | M&L for Pump down the existing refrigerant in separate cylinder. Disconnecting of electric motor of compressor refrigerant line gauges pipe opening and dismantle of reciprocating compressor for general overhauling model SMC 8 X 100 carry out the inspection of compressor, carry out the general overhauling of compressor includin 30 TR replacement of springs, aluminum washer packing screw work cleaning detergent cotton waste, etc and cleaning the suction filter oiul filter replacing the defective parts. Assembling the compressor tessting for leakage with nitrogen gas and rectify them. Re-charging of refrigerant R-22/R-407as per existing compressor oil and testing on connected load the compressor all as directed by Engr-in-charge.\nNote : spares and compressor and refrigerant shall be measured and paid separately as under and disconnecting,Transporting and refixing charges included in this job and no extra payment shall be admissible. | 2 | Each Job | |
3 | 2.01 | (a) Supply only piston pin bush | 8 | Each | |
4 | 2.02 | (b) Supply only overhauling gasket set SMC 8 X 100 | 3 | Each | |
5 | 2.03 | (c) Supply only suction reed | 8 | Each | |
6 | 2.04 | (d) Supply only discharge reed | 8 | Each | |
7 | 2.05 | (e) Supply only piston ring | 8 | Each | |
8 | 2.06 | (f) Supply only piston | 4 | Each | |
9 | 2.07 | (g) Supply only cylinder liner | 4 | Each | |
10 | 2.08 | (h) Supply only main bearing | 3 | Each | |
11 | 2.09 | (j) Supply only CR bearing | 3 | Each | |
12 | 2.1 | (k) Supply only discharge valve assy | 8 | Each | |
13 | 2.11 | (l) Supply only piston pin | 8 | Each | |
14 | 2.12 | (m) Supply only oil pump coupling | 3 | Each | |
15 | 2.13 | (n) Supply only oil pump repair kit | 2 | Each | |
16 | 2.14 | (o) Supply only shaft seal | 2 | Each | |
17 | 2.15 | (p) Supply only oil regulating valve | 2 | Each | |
18 | 2.16 | (q) Supply only compressor oil | 80 | Ltrs | |
19 | 2.17 | (r) Supply only oil filter cartriage | 3 | Each | |
20 | 3 | M&L for Opening of condenser cover of both sides including disconnecting of water pipe line for inlet and outlet of the condenser of each plant. Removing scale/sludge precipitated in the copper tube by push and pule method with iron rod connected with steel wire brush of suitable size as per condenser copper tube size at the entire length of condenser that scraping down the sludge precipitated in side the tube. Closing both side of condenser and circulating the descaling soulation in all tube of three condenser of each plant through the cidsrculating pump and allows holding it for 30 minutes for chemical reaction. Opning the condenser both sides and clean with iron road connected with nylon brush of suitable size as per condenser copper tube size at the entire length of condenser ensure that descaling process has been complete then closing the condenser at both end and circulating clean water in all the tube of three condenser of each oplant and drain out the process will be continue till the satisfaction of Engr-in-Charge then fixing new gasket for both ends of the three condenser of each plant tighten with new nut end bolt for the following plants :- | BI01010001010000000000000515BI0100001116 | 3 | Each Job |
21 | 3.01 | (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity | 3 | Each Job | |
22 | 3.02 | (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity | 3 | Each Job | |
23 | 3.03 | (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity | 3 | Each Job | |
24 | 3.04 | (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity | 3 | Each Job | |
25 | 3.05 | (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity | 3 | Each Job | |
26 | 4 | M&L for Pressure tasting for entire system of the following AC plant of all three set of condenser, compressor and circulating system with CO2/Nitrogen gas and retain to allow the pressure for three days. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage premanently :- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. | BI01010001010000000000000515BI0100001117 | 5 | Each Job |
27 | 5 | Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities sush as silt, dust particles mud/ sand inside the dume and around the fins, on wiremesh, main shaft etc and other connected items complete all as specified and directed by Engineer-in-Charge:- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. | BI01010001010000000000000515BI0100001118 | 7 | Each Job |
28 | 6 | M&L for blocking the punctured tubes of the following condensers with brass pillet complete all as specified and directed by Engr-in-Charge:- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. | BI01010001010000000000000515BI0100001119 | 6 | Each Job |
29 | 7 | M&L for Vacuum the system and after maintaining vacuum for 24 hours supply and charging refrigerant gas HCFC 22/R22/R407 as per existing complete all as specified and directed by Engr-in-Charge:- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. | BI01010001010000000000000515BI0100001120 | 190 | Kg |
30 | 8 | M&L for rewinding of induction electric motor upto Upto 5 HP capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates. | BI01010001010000000000000515BI0100001121 | 3 | Each |
31 | 9 | M&L for rewinding of induction electric motor upto 7.5 HP capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates. | 2 | Each | |
32 | 10 | M&L for rewinding of induction electric motor upto 10 to 15 HP capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates. | 2 | Each | |
33 | 11 | M&L for rewinding of induction electric motor upto 50 HP capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material and replacement of ball bearing complete all as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates. | 1 | Each | |
34 | 12 | S&F in replacement of power contactor for type MNX-18 Power rated 415 V, AC 3, 7.5 KW with auxiliary contacts 1 NO + 1 NC cat Pt No C101810/C101801, complete all as specified and directed by Engr-in-Charge. Make:- Havells/BCH/L&T. | 5 | Each | |
35 | 13 | All as per Srl item No 12 above but for type MNX-25 Power rated 415 V AC 3, 11 KW with auxiliary contacts 1 NO + 1 NC Make :- Make :- Havells/BCH/L&T | 2 | Each | |
36 | 14 | All as per Srl item No 12 above but for type MNX-40 Power rated 415 V AC 3, 18.5 KW with auxiliary contacts 1 NO + 1 NC cat Pt No Make :- Havells/BCH/L&T | 2 | Each | |
37 | 15 | Supply and Fix in replacement of mono-block Centrifugal pump set with Motor Capacity 7.5 HP including connecting head and connected accessories as suitable as per existing provisions and testing completed and complete all as specified and as directed by Engr In Charge. Note: Taking out old unserviceable Centrifugal pump & Motor deposit to MES Storeyard. | 2 | Each | |
38 | 16 | Supply and Fix in replacement of mono-block Centrifugal pump set with Motor Capacity 5 HP including connecting head and connected accessories as suitable as per existing provisions and testing completed and complete all as specified and as directed by Engr In Charge. Note: Taking out old unserviceable Centrifugal pump & Motor deposit to MES Storeyard. | 1 | Each | |
39 | 17 | Supply and Fix in replacement of mono-block Centrifugal pump set with Motor Capacity 3 HP including connecting head and connected accessories as suitable as per existing provisions and testing completed and complete all as specified and as directed by Engr In Charge. Note: Taking out old unserviceable Centrifugal pump & Motor deposit to MES Storeyard. | 1 | Each | |
40 | 18 | S&F repair/replacement of hand stuff off liquid valve including welding, brazing, soldering at each end including connecting pieces and testing of leakage of the following sizes or the near by sizes:-1/2" / 5/8" / 3/4" / 1" /5/4" / 3/2" as per existing complete all as specified and directed by Engr in Charge. | 8 | Each | |
41 | 19 | S&F as in repairs thermostat expansion valve suitable for refrigerant R-22 of the following capacityof plant:- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. | 6 | Each | |
42 | 20 | M&L for raping of laminated glass cloth cover at existing EPDM insulation for duct of AC plant in between AHU and shed including coating of UV resistent paint complete all as specified and directed by Engr-in-Charg. | 15 | SQM | |
43 | 21 | Removing of Alpha filter from its position and layout at site for refixing after clearing, AHU cooling coil using chemical with brass brush in-order to remove all type of sledge/dust precipitatated on the coil without any damage to the copper cooling coil then wash the cooling with fresh water and air blower upto the satisfactory of Engr-in-Charge. Cooling coil drain water shall be clean, if any type of obstacle on the flow of water, iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer over a coat of synthetic enameld pait including part of duct portion in the AHU shall be completed upto the satisfactory of Engr-in-Charge for the following AC plant :- | |||
44 | 21.1 | (a) AHU of Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity | 1 | Each | |
45 | 21.2 | (b) AHU of Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity | 2 | Each | |
46 | 21.3 | (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity | 2 | Each | |
47 | 21.4 | (d) AHU of Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity | 1 | Each | |
48 | 21.5 | (e) AHU of New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity | 2 | Each | |
49 | 21.6 | Supply and fix replacement of AC Plant AHU Motor Belt of size B-78 /B-121 etc as per existing complete all as specified and as directed by Engr in Charge. | 12 | Each | |
50 | 22 | M&L for Opening of pump 7.5 HP/10 HP centrifugal for repair and replacement of following u/s parts including re-fixing of all the same and testing and commissioning , complete all as specified and as directed by Engr-in-Charge\n(a) Replacement of gun metal impeller. -01 Nos \n(b)Replacement of gun metal bush -02 Nos \n(c) Replacement of ball bearing. Make: SKF - 01 Nos. \n(d) Replacement of oil seal -01 Nos. \n(e) Replacement of gland -01 Job . | 4 | Each Job | |
51 | 23 | All as per srl item No-22 here-in-before but upto upto 5 HP. | 5 | Each Job | |
52 | 24 | S&F in replacement of AHU pre filters EU4 /G4 of size 610X610X50mm having filteration capacity as per sample complete all as specified and as directed by Engineer-in-charge. | 6 | Each | |
53 | 25 | S&F in replacement of AHU pre filters EU4 /G4 of size 610X305X50mm having filteration capacity as per sample complete all as specified and as directed by Engineer-in-charge. | 3 | Each | |
54 | 26 | S&F in replacement of AHU pre filters EU4 /G4 of size 305X610X50mm having filteration capacity as per sample complete all as specified and as directed by Engineer-in-charge. | 2 | Each | |
55 | 27 | S&F in replacement of AHU pre filters EU4 /G4 of size 305X305X50mm having filteration capacity as per sample complete all as specified and as directed by Engineer-in-charge. | 1 | Each | |
56 | 28 | S&F in replacement of of electronic circuit board (Dishplay) of AC plant by OEM service engineer removing defects including replacement of all unserviceable spares and testing complete all as specified and as directed by Engineer-in-charge. Make Voltas OEM | 2 | Each Job | |
57 | 29 | M&L for servicing of compressor including oil draining and dismantling of liquid line filter and de-scaling old housing & re-fixing after replacing the filter and refilling new oil 25 Ltrs in compressor complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | |
58 | 30 | M&L for replacement of non freezing oil N-68 complete all as specified and as directed by Engineer-in-charge. Make:- Castrol/ Servo | 25 | Ltrs | |
59 | 31 | M&L for painting of AC plant as per existing colour including compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipeline & connected valve including wiriting SM/MES No. Of AC plant of capacity 3X30TR plant & 3 x 50 TR AC Plant,3x 75 TR,3 x 11 TR, 3 x 35 TR Plant complete all as specified and as directed by Engineer-in-charge. | 5 | Each Job | |
60 | 32 | S&F in replacement of MCCB 415V AC with thermal adjustable magnetic setting four pole 400 Amps 36 KA complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/L&T | 1 | Each | |
61 | 33 | S&F in replacement of MCCB 415V AC with thermal adjustable magnetic setting four pole 250 Amps complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/L&T | 1 | Each | |
62 | 34 | S&F in replacement of MCCB 415V AC with thermal adjustable magnetic setting three pole upto 100 Amps complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/schinider/L&T | 1 | Each | |
63 | 35 | S&F in replacement of motor protection 3-phase IEC rated contactor20 HP at 230V and 40 HP at 460V , Conforms to IEC 60946 Model No Siemens 3TF46 complete all as specified and as directed by Engineer-in-charge. Make Siemens/ L&T | 3 | Each | |
64 | 36 | S&F in replacement of MCB TP/TPN upto 63 AMP 10KA as per sample complete all as specified and as directed by Engineer-in-charge. Make Indo Asian/ L&T/Legrand | 10 | Each | |
65 | 37 | M&L for Pre - insulated MS pipe dia upto 80 mm , Class 'C' having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge Aluminium cladding complete suitable for above ground with all mounting arrangements like clamps with nut bolt etc, complete all as specified and as directed by Engineer-in-charge. Make-Jindal/TATA | 45 | RM | |
66 | 38 | M&L in replacement of high pressure/Low Pressure/oil pressure Cutout for R134 complete all as specified and as directed by Engineer-in-charge. Make: Danfoss/ Indofoss | 4 | Each | |
67 | 39 | S&F in replacement of duct filter suitable for AC plant of size 600X600X150mm filter media capacity shall capable 5 micron as per existing make air flow complete all as specified and as directed by Engineer-in-charge. | 2 | Each | |
68 | 40 | S&F in replacement of aluminium sprinkler 3'X63mm with MT complete make active cooling tower complete all as specified and as directed by Engineer-in-charge. | 5 | Each | |
69 | 41 | S&F in repair of AHU motor suitable for AC plants/Dehumidifier unit/Air washer of motor capacity upto 30 HP by dismantling it from weather making unit of AHU, replacement of Bushes, bearings by opening nuts bolts and removing electrical connections of the motor, replacement of V type Belt with new belt, replacement of stator and rotor assembly, winding of motor with Copper enameled wire of required thickness as existing, replacement and alignment of shaft, complete all as specified and as directed by Engr-in-Charge. | 3 | Each JOB | |
70 | 42 | S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80mm as per sample existing icluding bending and welding work and testing complete this job complete all as specified and directed by Engr in charge. | 15 | RM | |
71 | 43 | S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100mm as per sample existing icluding bending and welding work and testing complete this job complete all as specified and directed by Engr in charge. | 20 | RM | |
72 | 44 | Dismantling and taking down from existing duct if required of various sizes upto 1400mm for Inner duct cleaning, servicing, denting, at site AC Plant and Air washer and re-fixing the same including replacement of gasket, nut & bolts etc complete all as specified and as directed by Engineer-in-charge. | 200 | RM | |
73 | 45 | S&F in replacement of Pressure Gauge with replacement of connected rusted out pipeline complete as specified and direcetd as site.Make H-Guru | 4 | Each | |
74 | 46 | S&F in replacement of Temp Gauge as per matching to existingtype with replacement of connected rusted out pipeline complete as specified and direcetd as site. Make H-Guru. | 4 | Each | |
75 | 47 | S&F in replacement of Syphone as per matching to existing type with replacement of connected rusted out pipeline complete as specified and as directed as site. | 4 | Each | |
76 | 48 | S&F in replacement of Cast Iron butterfly valve (wafer Type) without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-10/PN-16 by replacing the existing upto 80 mm dia, complete all as specified and as directed by Engr-in-Charge. \nMake : Zoloto Cat No 1078B/Leader/castle/Advance | 8 | Each | |
77 | 49 | S&F in replacement of Cast Iron butterfly valve (wafer Type) without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-10/PN-16 by replacing the existing one 100 mm dia, complete all as specified and as directed by Engr-in-Charge. \nMake : Zoloto Cat No 1078B/Leader/castle | 2 | Each | |
78 | 50 | Taking down RO water purifier and aquaguard including opening and taking out the filters and accessories and cleaning, servicing the filters accessories and other connected items refixing the same after repairs at the existing position and providing any repair work required after this complete servicing through out the contract period complete all as specified and as directed by Engineer-in-charge. Make: Kent RO Qty-5 Opening the RO water purifier 50 LTR Capacity and servicing with chemical and replacement of following items | 4 | Each Job | |
79 | 50.01 | (a) 5 micron chlorine taste & Odor reduction filter 20" Make Kemflo | 4 | Each | |
80 | 50.02 | (b) 5 micron cotton Spun water filter catridge 20" Make Kemflo | 10 | Each | |
81 | 50.03 | (c ) Non Returning valve size 1/4 as per existing | 4 | Each | |
82 | 50.04 | (d) water flexible pipe 1/4" to 3/8" | 12 | RM | |
83 | 50.05 | (e) Membrane Housing for Model No 103 make : Osram | 5 | Each | |
84 | 50.06 | (f) Membrane 80GPD Model RE1812-80 make CSM | 30 | Each | |
85 | 50.07 | (g) Solenoid valve ORIFICE 2.5M SLC-2 24 V DC Model-0-120psi Make SANLI XIN | 20 | Each | |
86 | 50.08 | (h) Low Pressure/High Pressure switch 24 VDC Make -SANLI XIN | 10 | Each | |
87 | 50.09 | (i) Elbow and Tee Plaintype/push type size 1/4'' to 3/8" | 25 | Each | |
88 | 50.1 | (j) pressure pump EC-103-75 Model No 103 Make : E CHAIN | 3 | Each | |
89 | 51 | Detecting the fault of any capacity of AC Plants and any location by providing skilled Refrigerent Mechanic/Skelled Elect & helper with necessary safety and working equipment such as ,multimeter , speedometer and other reqd tools and plants and rectified the defects on top priority basis/as and when reqd including testing, complete all as specified and directed by Engineer-in-Charge. | 12 | Each Job | |
90 | 52 | T&P and Labour for disconnecting the condecing line /chiller line (Condencer/Chiller to AHU) detect the Line blockage and rectify blockage and refixing the line and testing completed completed all as specified and as directed. | 2 | Each Job | |
91 | 53 | M&L ,T&P for servicing of the window AC AC 1.5/2 ton capacity of any make ,including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles, proper connections of wires etc and re-fixing the air conditioner at its origional position by the experienced ref mech all as directed by Engr-in-Charge (Note :- (i) Any u/s items other than specified above need to be replaced/gas charging etc shall be replaced & paid under seperately respective items. (ii) the cost of Taking out window AC 1.5/2.0 Ton from window and shifting to location where directed for proper washing and servicing with soap water jet followed with clean water jet and the help of blower, wipe and clean the unit with dry cloth and refixing the same shall be deemed to be included in item rate quoted. | 30 | Each | |
92 | 54 | All same as per Item No. 53 but for Servicing of split type AC of capacity 1.5/2.0 TR capacity of any make by washing the outdoor unit condenser coil with soap water jet followed with clean water jet and indoor unit with the help of blower, wipe and clean the unit with dry cloth, complete all as specified and directed by Engg-in charge. | 260 | Each | |
93 | 55 | S&F in replacement Blower/ condensor Copper fan motor ISI Marked of three speed, testing, commissioning complete suitable for window type/ Split type 1.5 to 2 Ton AC suitable to operate 230V AC all as specified and directed. | 16 | Each | |
94 | 56 | S&F in replcement of blower motor suitable for indoor unit rating and capacity as per site requirement for upto 2.0 ton capacity Split type AC complete all as specified and as directed by Engr-in-charge. | 14 | Each | |
95 | 57 | S&F in replacement Condenser fan blade made out of aluminium/plastic as per matching to existing suitable for window /split type AC upto 2.0 ton capacity complete all as specified and as directed by Engr-in-charge. | 20 | Each Set | |
96 | 58 | S&F in replacement Front grill suitalbe for window type AC upto 2 ton capacity complete all as specified and as directed by Engr-in-charge. | 5 | Each | |
97 | 59 | S&F in replacement Copper Condensing coil suitable for split type AC of capacity up to 2 ton complete all as specified and as directed by Engr-in-charge. | 7 | Each | |
98 | 60 | S & F in replacement Copper cooling coil suitable for split type AC of up to capacity 2 ton complete all as specified and as directed by Engr-in-charge. | 5 | Each | |
99 | 61 | S&F in replacement of indoor sealed unit of split type AC of capacity 2TR comprises of PCB, filters complete indoor set of 5 star rated Inverter AC complete all as specified and directed. \nNote: Unserviceable unit will be deposited to MES store.\nMake: Cat No Copper SAC_245V_ZZV White of Voltas/Cat No Alloy AC 2T GIC 24 MGP5-WRA Split 5S White of Godrej and equialent makes | 2 | Each | |
100 | 62 | S&F in replacement of outdoor sealed unit of split type AC of capacity 2 TR comprises of copper condenser, condenser motor, fan and blade, compressor, capacitor, suction, discharge valve, outer cover duly power coated complete indoor set of 5 star rated Inverter AC complete all as specified and directed. \nNote: Unserviceable unit will be deposited to MES store.\nMake: Cat No Copper SAC_245V_ZZV White of Voltas/Cat No Alloy AC 2T GIC 24 MGP5-WRA Split 5S White of Godrej | 2 | Each | |
101 | 63 | M&L in Replacement of PCB for window/Split type AC up to 2 Ton capacity replacement unserviceable parts complete all as specified and as directed by Engr-in-charge. | 22 | Each | |
102 | 64 | M&L in replacement PCB for window/Split type AC up to 2 Ton capacity as pwer matching existing complete all as specified and as directed by Engr-in-charge. .Make Voltas/LG | 10 | Each | |
103 | 65 | S&F in replacement of electronic digital 2 AC Timer for 2 AC for server room of programe for 1 hr to 12 hr as per matching to existing complete all as specified and as directed by Engr-in-charge. | 6 | Each | |
104 | 66 | S&F of Split/Window AC rotary compressor of capacity 1.5 TR in replacement and fixing including brazing work etc with replacement of capillary, filter, pressure testing & establishing vacuum for 24 hours for dehydration, complete all as specified and directed by Engr-in-Charge. Make : Tecumseh/Kirloskar/Emerson Copeland | 8 | Each Job | |
105 | 67 | S&F of Split/Window AC rotary compressor of capacity 2 TR in replacement and fixing including brazing work etc with replacement of capillary, filter, pressure testing & establishing vacuum for 24 hours for dehydration, complete all as specified and directed by Engr-in-Charge. \nMake : Tecumseh/Kirloskar/Emerson Copeland | 8 | Each Job | |
106 | 68 | S&F of Split/Window AC reciprocating compressor of capacity upto 2 TR in replacement and fixing including brazing work etc with replacement of capillary, filter, pressure testing & establishing vacuum for 24 hours for dehydration, complete all as specified and directed by Engr-in-Charge. Make : Tecumseh/Kirloskar/Emerson Copeland | 2 | Each Job | |
107 | 69 | Supply only of Starting with Running Multi Capacitor capacity 6 to 50 mfd as per existing complete all as specified and directed by Engr-in-Charge. make :Tibcon/Seacon | 80 | Each | |
108 | 70 | Supply only Starting duel Capacitor of 80 to 120 mfd complete all as specified and directed by Engr-in-Charge. Make Tibcon/ Seacon | 35 | Each | |
109 | 71 | S&F in replacement Wiring kit suitable for 1.5 to 2.0 ton capacity AC complete all as specified and directed by Engr-in-Charge. | 15 | Each | |
110 | 72 | S&F in replacement Refrigerant gas filter and capilary assembly for Split ac /window Ac as per existing complete suitable for AC upto 2 ton capacity complete all as specified and directed by Engr-in-Charge. | 20 | Each | |
111 | 73 | Supply only gas charging pin valvecomplete all as specified and directed by Engr-in-Charge. | 18 | Each | |
112 | 74 | Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another locatiion in the same or other building in the complex complete all as specified and directed by Engr-in-Charge. | 5 | Each Job | |
113 | 75 | Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischare copper piuping and shifting to another locatiion in the same or other building in the complex complete all as specified and directed by Engr-in-Charge. | 8 | Each Job | |
114 | 76 | Supply and charging the gas refrigerant (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of notorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed by Engr-in-Charge. | 22 | Each job | |
115 | 77 | All same as per item No 76 here-in-before but split type AC up to 2 TR capacity complete all as specified and directed by Engr-in-Charge. | 135 | Each job | |
116 | 78 | M&L for replacement of split valve ¼” to 5/8"for split AC upto 2 ton capacity as per existing complete all as specified and directed by Engr-in-Charge. | 8 | Each | |
117 | 79 | S & F in replacement of Copper tubing of size 1/4" / 1/2" / 3/8" / 5/8" suitble for any type of split type AC complete all as specified and directed by Engr-in-Charge. | 220 | RM | |
118 | 80 | Supply only flexible condence water pipe suitable for any type of AC complete all as specified and directed by Engr-in-Charge. | 160 | RM | |
119 | 81 | S&F in replacement of synthetic rubber tube for insulation for refrigerant copper piping of size 1/4" to 5/8" internal dia split type AC as per existing complete all as specified and directed suitable for the under mentioned sizes. MAKE- KAIFLEX | 220 | RM | |
120 | 82 | S&F in replacement of window AC complete chasis including cooling coil, condensing coil, fan motor, blower, condensing fan,PCB,Front grill and complete body without compressor suitable for window AC of capacity 1.5 ton complete all as specified and as directed by Engr-in-Charge. | 4 | Each | |
121 | 83 | Supply only of remote for window / split type AC as per matching existing complete all as specified and directed by Engr-in-Charge. | 20 | Each | |
122 | 84 | Supply only of remote Battery (Pack of Two) for window / split type AC as per matching existing complete all as specified and directed by Engr-in-Charge. Make Evereaday and equialent makes | 60 | Each set | |
123 | 85 | S&F in replacement of condensate water collecting tray for window AC installed in bldg upto 5 storey complete all as specified and directed by Engr-in-Charge. | 4 | Each Job | |
124 | 86 | Supply only metal plug top 2 pole and earth, 20 Amps, 250 volts suitalbe for sheet metal enslousers complete all as specified and directed by Engr-in-Charge. | 45 | Each | |
125 | 87 | Supply only metal clad socket 2 pole and earth, 20 Amps 250 volts suitalbe for sheet metal enclusers complete all as specified and directed by Engr-in-Charge. | 20 | Each | |
126 | 88 | Supply only MCB single pole, 32 Amps, 10 KA 240 Volts, 50 HZ type. C series complete all as specified and directed by Engr-in-Charge. | 65 | Each | |
127 | 89 | S&F in replacement sheet metal enclosure single pole and neutral with 2 pin and earth socket complete with one single pole MCB 20 A, 10 KA 'C' series complete all as specified and directed by Engr-in-Charge. | 30 | Each | |
128 | 90 | Supply onlyt of PVC insulated flexible copper conductor 3/4 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed by Engr-in-Charge. | 250 | RM | |
129 | 91 | M&L in replaqcement sub main wiring with two run of single core strated copper conductor cable of size 4 Sqmm and 2.5 Sqmm copper conductor cable as earth continuity conductor drawn in existing conduit or PVC casing capping complete all as specified and directed by Engr-in-Charge. | 220 | RM | |
130 | 92 | S&F in replacement AC stand suitable for out door AC unit up to cap of upto 2 ton capacity complete all as specified and directed by Engr-in-Charge. | 15 | Each set | |
131 | 93 | M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed by Engr-in-Charge. | 8 | Each job | |
132 | 94 | Supply and charging the gas in the water cooler of any make and capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specified and directed by Engr-in-Charge. | 4 | Each job | |
133 | 95 | S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed by Engr-in-Charge. Make : Renutrol or equivalent out of makes specified in list of makes. | 2 | Each | |
134 | 96 | S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed by Engr-in-Charge. | 8 | Each | |
135 | 97 | S&F in replacement company sealed compressor unit of water coolers of capacity 40 to 180 ltrs as per existing complete all as specified and directed by Engr in Charge. | 2 | Each | |
136 | 98 | M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule. | 20 | Each Job | |
137 | 99 | M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge.\nNote : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting. | 30 | Each Job | |
138 | 100 | Supply only of wood wool pad (set of three) heavy duty for desert cooler complete all as specified and as directed by Engineer-in-charge. | 40 | Each Set | |
139 | 101 | Supply only of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and as directed by Engineer-in-charge. Make:- Khaitan/Havells/Bajaj. | 40 | Each Job | |
140 | 102 | Supply only desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts, fanblade/bolts for fixing of fan motor complete with connection & testing complete all as specified and as directed by Engineer-in-charge. Make:- Khaitan/Havells/Bajaj. | 25 | Each Job | |
141 | 103 | Supply only of commercial ply wood BWP 4mm thick ISI marked for desert cooler/window AC of any size to close the opening between desert cooler grill and window complete all as directed by Engr-in-Charge. | 18 | SQM | |
142 | 104 | Supply only plug top 3 pin 5 Amps complete all as specified and as directed by Engineer-in-charge. | 10 | Each | |
143 | 105 | Supply only plug top 3 pin 15 Amps complete all as specified and as directed by Engineer-in-charge. | 35 | Each | |
144 | 106 | Supply only motor capacitor 2.5/3.15/4 Mfd complete all as specified and as directed by Engineer-in-charge. | 25 | Each | |
145 | 107 | Supply only front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and as directed by Engineer-in-charge. | 25 | Each | |
146 | 108 | Supply only of body without side panels made out of galvanised iron sheets of of 18 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge. | 25 | Each | |
147 | 109 | Supply only of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed by Engineer-in-charge. | 75 | Each | |
148 | 110 | Supply only of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler/Desert cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as directed by Engr-in-Charge. | 8 | Each | |
149 | 111 | Supply only of switch board with switch for motor, pump and selector switch for motor speed variation complete all as specified and as directed by Engineer-in-charge. | 25 | Each Set | |
150 | 112 | S&F in replacement of PVC rubber pipe 15mm bore heavy duty including pvc elbow threaded suitable for insertion in flexible PVC pipe complete all as specified and as directed by Engineer-in-charge. | 18 | RM | |
151 | 113 | Supply only of PVC water distributor four way complete all as specified and as directed by Engineer-in-charge. | 25 | Each | |
152 | 114 | M&L laying in replacement of GI pipe 25 mm bore medium grade with fitting complete all as specified and as directed by Engineer-in-charge. | 15 | RM | |
153 | 115 | M&L laying in replacement 15 mm GI pipe bore medium grade with fitting complete all as specified and as directed by Engineer-in-charge. | 55 | RM | |
154 | 116 | M&L in replacement 15 mm GI union ISI marked complete all as specified and as directed by Engineer-in-charge. | 5 | Each | |
155 | 117 | M&L in replacement gate valve 25 mm complete all as specified and as directed by Engineer-in-charge. | 3 | Each | |
156 | 118 | M&L in replacement gate valve 15 mm bore complete all as specified and as directed by Engineer-in-charge. | 6 | Each | |
157 | 119 | S&F in replacement of compressor for refrigerator of capacity upto 310 Ltrs as per matching to existing complete all as specified and as directed by Engineer-in-charge. | 2 | Each | |
158 | 120 | M&L for repair to refrigerator any capacity upto 310 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified and as directed by Engineer-in-charge. | 1 | Each Job | |
159 | 121 | S&F in replacement of compressor for deep freezer of capacity 425 Ltrs as per matching to existing complete all as specified and as directed by Engineer-in-charge. | 1 | Each | |
160 | 122 | M&L for repair to deep freezer any capacity upto 425 Ltrs including replacement of all spares like any relay, wiring, thermostate, capacitor, leakage testing & stopping the leakage and charging the refrigerant gas complete all as specified as directed. | 1 | Each Job | |
161 | 123 | M&L for Servicing of voltage stabilizer AC single phase 2 to 5 KVA of any make by opening of body, cleaning internally checking and tightening of all terminal connections including replacement of worn out terminals connectors, screw, bolts etc complete all as specified and directed by Engineer-in-charge. | 85 | Each Job | |
162 | 124 | Supply & fix compressor for bottled water dispenser including brazing work creating vacuum for 24 hrs for pressure testing and charging of refrigerant R134a, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity1.6 ltrs, working in R - 134a refrigerant, complete all as specified and as directed by Engr-in-Charge. \nMake-Voltas/LG/Emerson Copeland | 2 | Each Job | |
163 | 125 | S&F in replacement of Voltage Stabilizer for automatic operation single phase 230 volts 50 C/s AC 160 volt to 250 volts + 2.5 % of capacity 5 KVA electronic digital type wall mounted type, complete all as specified and directed by Engr-in-charge. \nMake: Cat No 1SB44B of Volina/Cat No PS 170 Power plus of Crompton/Cat No VG-500 of V-Guard \nNote: Unserviceable units will be deposited to MES store | 22 | Each | |
164 | 126 | S&F in replacement of mini magic pure-T dispenser, tank material of stainless steel, its function for Hot, Normal & cool complete all as specified and as directed by Engineer-in-charge.Voltas/LG/Godrej | 4 | Each | |
165 | 127 | S&F replacement of Refrigerator of capacity 195 Ltr , 230 Volts,5 star rating single door type complete all as specified and as directed by engr-in-charge.Make : LG/Godrej Note: Unserviceable units shall be deposited to MES store | 1 | Each | |
166 | 128 | S&F replacement of water cooler of capacity 60/120 Ltr , 230 Volts, complete all as specified and as directed by engr-in-charge.Make :Voltas/LG/Godrej Note: Unserviceable units shall be deposited to MES store | 2 | Each | |
167 | 129 | S&F replacement of Deep Freezer of capacity 425 Ltr , 230 Volts, complete all as specified and as directed by engr-in-charge. Make :Voltas/LG/Godrej Note: Unserviceable units shall be deposited to MES store | 1 | Each | |
168 | 130 | Attending complaints related to Air Conditioning including replacement & minor repairs like reconnections,Stabilizer reconnections, Water leakage from AC, Wire fault rectification, replacement of Supply only items, replacement of screw/washers any type & size, insulation tape replacement etc and obtaining completion of user on complaint slip, complete all as specified and as directed by engineer-in-charge. Contractor shall attend the complaints on requirement bases from 0830 to 1730 hours on working days including on non-working day also if required for that contractor shall deploy at least 01 Refrigerent Mechanic with 01 No helper at 13 BRD/16BRD and at least 01 Refrigerent Mechanic with 01 No helper at27 ED/ 31MCU for Day to day on all working day.The cost of said Refrigerent Mechanic and helpers shall be included in cost of attending complaints under this item and No extra payment on this accound shall be given to the contractor. | 650 | Each Job | |
169 | 131 | Note :- (a) The amount of Rs 1,21,253/- against Schedule of Credit on Srl Page 126 to 127 shall be deducted from the total amount quoted against Sch 'A'. (b) 1. The contractor shall deploy sufficient technician with helpers for maintenance of summer appliances at 13BRD, 16 BRD, 27 ED & 31 MCU and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints to complete the same complaint detailed by JE E/M /Engineer-in-charge within 24 hrs. (c) The complaints shall be rectified with in 24 hrs. If the complaints is/are not complited within 24 hours (except repair/ replacement of major items like repair/ replacement of compressor, cooling coil, condensing coil, fan motor ducting work of AC plant & insulation work. These work can be completed in time period (max 36 Hrs) as decided by Engineer-in-charge after which penal recovery shall be made @ 100/- per complaint per day. The decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. (d) The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station PALAM. (e) The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge. (f) Contractor has to submit copy of MOU with any one of the OEM of cooling machinery within 20 days of work order as mentioned in the particular specifications failing which recovery shall be made on this account @ rate of Rs. 2000/- per week. |