Housing Urban and Rular Development Government Departments Closing in 0 days TDR #27836802

Supply Of Laboratory/Field Equipment And Consumables As Part Of Creating Departmental Facility For Subsequent Quality Monitoring/ Material Testing At District Material Testing Laboratory Baramulla

Issued by Government Departments · Baramulla, Jammu And Kashmir
Tender Value
8.40 Lakhs
Estimated cost
Bid Submission
17 May 2021
0 days left
EMD
25200
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Laboratory / Field Equipment And Consumables As Part Of Creating Departmental Facility For Subsequent Quality Monitoring / Material Testing At District Material Testing Laboratory Baramulla - 1 Iss Sieve Sets ( As Per Specifications Of Nis:460 ) Niss Gi-Frame Sieve Set. ( Size 30Cm Dia ) Na ) 80 Mm Nb ) 63 Mm Nc ) 45 Mm Nd ) 40 Mm Ne ) 37.5 Mm Nf ) 26.5 Mm Ng ) 20 Mm Nh ) 19 Mm Ni ) 16 Mm Nj ) 13.2 Mm Nk ) 12.5 Mm Nl ) 11.2 Mm Nm ) 10.0 Mm Nn ) 9.5 Mm No ) 6.3 Mm Np ) 5.6 Mm Nq ) 2.8 Mm Nr ) 4.75 Mm Ns ) 3.35 Mm Nt ) 2.36 Mm N ( Complete & Operational In All Respects ) . N 2 Iss Sieve Sets ( As Per Specifications Of Is:460 ) Niss Brass Sieves. ( Size 20Cm Dia ) ; Sizes ( Mm / Micron-Μ ) : Na ) 4.75 Mm Nb ) 2.36 Mm Nc ) 1.18 Mm Nd ) 0.600 Mm Ne ) 0.425 Mm Nf ) 0.300 Mm Ng ) 0.150 Mm Nh ) 0.090 Mm Ni ) 0.075 Mm N ( Complete & Operational In All Respects ) . 3 Precision Electronic / Digital Nbalance, With Dual Power Operation ( Ac / Battery ) Cas Or Equivalent: Nsuperior Brand Precision Digital Balance ( 5 Kg ) , Capable Of Measuring 0.5 Gm To 5 Kg With Permissible Error. N ( Complete & Operational In All Nrespects ) 4 Precision Electronic / Digital Nbalance, With Dual Power Operation ( Ac / Battery ) Cas Or Equivalent: Nsuperior Brand Precision Digital Balance ( 30Kg ) , Capable Of Measuring 1.0 Gm To 30 Kg With Permissible Error. N ( Complete & Operational In All Nrespects ) 5 Precision Infrared Thermometer N ( Fluke Or Superior Make ) Ndigital Non-Contact Infrared Thermometer ( Fluke Or Superior Make ) , With Backlight Lcd Display, Battery Powered, With Minimum Operational Temperature Range Of -20°C To 300°C ( Or Better ) , Display Resolution Of At Least 0.1 °C / °F, Suitable Spectral Response, Class-2 Laser Power With Display Hold Feature. N ( Complete & Operational In All Nrespects ) 6 Thermometer Ndigital Contact Type Probe Thermometer ( Superior Make ) , Battery Powered, With Minimum Operational Temperature Range Of - 50°C To 300°C ( Or Better ) , Display Resolution Of At Least 0.1 °C / °F. N ( Complete & Operational In All Nrespects ) 7 Aggregate Impact Testing Machine N ( As Per Specifications Of Is:9377 ) Nstandard Aggregate Impact Testing Machine For Determination Of Impact Value For Small Size Mineral Aggregates / Rocks. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 8 Bitumen Binder Centrifuge Nextractor N ( As Per Relevant Is Specifications / Astm D 2172 ) Nmanually Operated Bitumen Binder Centrifuge Extractor For Bituminous Mix Up To N1.5 Kg Capacity, With Hand Speed Control, With Filter Paper Discs ( Set Of 500 Sheets ) . Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) 9 Consistency Test Apparatus Nthe Test Apparatus Must Be As Per Is: 2720 Part-5, Is: 9259 Relevant Specifications, For Determination Of Consistency ( Liquid Limit ) Of Soils By Casagrande Method. The Apparatus Must Be Manually Operational, With Counter, With Is / Bs / Astm Grooving Tools, Gauging Block. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 10 Enamel Ei-Trays: Nsampling Purpose Enamel Tray / Plates / Bucket Of Following Minimum Sizes. Na ) 250X300 Mm Tray. 11 B ) 450X600 Mm Tray N ( Complete & Operational In All Respects ) 12 Flakiness Apparatus ( Shape Test Nas Per Is Specifications / Sp-36, Is:2386 ( Part 1 ) Nequipment Must Consist Of Following: Thickness Gauge Manufactured From Heavy Gauge Steel With Is-Certification Stamp. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 13 Elongation Apparatus ( Shape Test ) Nas Per Is Specifications / Sp-36, Is:2386 ( Part 1 ) Nequipment Must Consist Of Following: Nlength Gauge Manufactured From Superior Steel, Mounted On A Hardwood Base, With Is- Certification Stamp. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 14 Cone & Bitumen Penetration Kit ( Is: 1448 ( Part 60 ) , Astm: D 937, Ip: 179, Bs:4698, Nastm: D 217, Ip: 50, Iso: 2137, En:1426, N13179-2 ) Nequipment Must Consist Of Following Replicable Parts Na ) Universal Penetrometer With Adjustable Head And Display ( 1 No ) . Nb ) Penetration Cone For Determination Of Consistency Of Lubricating Grease And Oils ( 1 No ) . Nc ) Bitumen Penetration Kit Consisting Of Penetration Needle, Copper Transfer Dish, Aluminum Containers ( 1 No ) . Nd ) Penetration Test Cone For Soils, With Cups ( 1 No ) . Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 15 Softening Point Apparatus N ( As Per Is:1205 Ring And Ball Type ) : Nequipment Must Be Capable For Determining Temperature At Which A Sample Of Bituminous Specifically Loaded Will Achieve Certain Degree Of Softening. Apparatus Must Have Arrangement For Magnetic Stirring Of Water Bath, Adjustable Heating System With Digital Display Of Temperature. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 16 Cleveland Flash ( Open ) & Fire Point Apparatus. N ( As Per Specification Of Is:1448, P:69, Is: 73- 2013 ) Nequipment Must Be Capable For Determining Flash & Fire Point Of Bitumen. The Flash Cup Must Be Made Of Brass With Insulated Handle. Equipment Must Have A Metal Heating Plate Electrically Operated With Energy Regulator & Gas-Jet Assembly ( Complete In All Respects With All Noptional Accessories ) . 17 Absolute ( Dynamic ) & Kinematic Viscosity Apparatus ( As Per Is Specifications 1206 Part-Ii & Part-Iii, Is:73- 2013 ) Equipment Must Comprise Of Following Na ) 2-No Imported Viscometer Tubes ( Cannon-Manning Vacuum Viscometer ) Made Of Borosilicate Glass With Size No:12 ( Is: 1206-Part-Ii ) For Determination Of Absolute Viscosity In The Range Of 300 To 8000 Poise At 60°C, Along With Calibration Certificate. Nb ) 2-No Imported Viscometer Tubes ( Cannon-Fenske Viscometer ) Made Of Borosilicate Glass With Size No:350 ( Is: 1206-Part-Ii ) For Determination Of Kinematice Viscosity In The Range Of 30 To 500 Cst At 135°C, Along With Calibration Certificate. Nc ) 1-No Oil Free Vacuum Application System With 4- Lines, With Vacuum Range Up To 300Mm Of Hg, And Least Measurable And Maintainable Level Of ±0.5Mm Of Hg. Nd ) 3-No Mercury In Glass Tube Type Thermometer With Range Of 0°C To 150°C, Scale ± 0.2°C ( As Per Is: 1206 Part-Ii ) Ne ) 1-No Viscometer Silicon Bath, With Uniform Temperature Maintenance System, Using Accurate Pdi Temperature Controller With Accuracy Of ±1° C, For Conduction Of Absolute & Kinematic Viscosity Test On Bituminous And Cut-Back Materials By Vacuum Capillary Method At Specified Temperatures. ( Complete & Operational In All Respects With All Optional Accessories ) . 18 Thickness Gauge Nms Thickness Gauge With Minimum Gauging Depth Of 150Mm N ( Complete & Operational In All Nrespects ) 19 Hydrometer: Nas Per Is Specifications / Sp-36, Is:2720 ( Part 4 ) , Is:3014. N ( For Soils / Fines With >10% Passing 75 Micron Sieve ) Nsoil Hydrometer Made Of Superior Clear / Transparent Glass Of Uniform Clarity Throughout The Upper Density Scale End. The Density Scale Range Must Be 0.995 To 1.30 G / Cc ( G / Ml ) At 27°C, With Least Count Of 0.0005 G / Cc ( G / Ml ) . There Shall Be No Abrupt Changes In The Cross Section Of The Hydrometer, Such As Will Hinder Cleaning Or Permit Air Bubbles To Be Trapped. The Hydrometer Shall Have Maximum Permissible Scale Error Of Plus / Minus One Scale Division. ( Complete & Operational In All Respects ) 20 Soil Pycnometer ( As Per Ref. Standard Is: 2386 ) N ( For Determination Of Specific Gravity Of Clays, Sands, And Gravels Of Grain Size N<10Mm. ) Nequipment Must Consist Of 1-Kg / 1-Liter Superior Glass Bottles, With Bored Brass Cone Stopper, With Locking Ring And Rubber Seal. ( Complete & Operational In All Respects ) 21 Electric Hot Air Oven ( Reputed Make ) Nsuperior Laboratory Electric Oven, Thermostatically Controlled Or With Digital Controller Cum Indicator With Safety Alarm. It Must Be Double Walled, With Outer Body Made Of Ms Powder Coated & Inner Made Of Stainless Steel. It Must Have Provision For Horizontal Ribs For Adjusting Trays At Any Height. Equipment Must Have Side Heating / Air Circulating Fan, To Distribute The Temperature Range 50°C To 250°C ± 1°C, With Air-Ventilators. The Size Of Oven Must Be 450X450x450 Cm, With Size Tolerance ± 10Mm. Equipment Must Operate Under 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply Equipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Respects ) 22 Table Mounted Marshall’S Stability Apparatus N ( As Per Is / Astm D-1559, D-6927 Specifications ) Equipment Must Consist Of Marshals Stability Loading Frame 50Kn Capacity ( With Proving Ring ) , Single Speed With Platen Speed Of 50.8Mm / Min ( Precise Speed ) , Suitable To Operate On 220V, 50 Hz, Single Phase Ac-Supply, Limit Switch Protection For Both Upward And Downward Travel, Nfollowing Must Be Supplied With The Apparatus; Na ) Marshalls Steel Compaction Hammer, Weight N4.5 Kg, With A Free Fall Of 457Mm ( 2-No ) . Nb ) Compaction Moulds ( 10.16 Cm Dia And 7.6 Cm Height, For 25.4Mm Maximum Nominal Aggregate Size ) Of Steel Cylindrical, With Individual Extension Collar And Base Plates ( 3-No ) Nc ) Hydraulic Sample Eject ( 1-No ) . Nd ) Sample Breaking Head With Load Transfer Bar And Flow Measurement Arrangement Using Dial- Gauge. Ne ) Compaction Pedestal Comprising Of Steel Plate Capped Wooden-Post. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Respects ) 23 Water Bath ( Reputed Make ) Nwater Bath ( 12 Holes ) Thermostatically Controlled Or With Digital Controller Cum Indicator, Doubled Walled, Inner Chamber Made Of Non-Rusting / Stainless Steel, Outer Body Made Of Ss And Minimum Dimensions ( 425X325x100 ) Mm Or Better, With Temperature Range Of 5°C To 100°C With Precision Of ±0.5°C, Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 24 Motorised Sieve Shaker Nequipment Must Consist Of Motorized Sieve Shaker For Sieving Dry Granular Or Powdered Materials / Soils. It Must Accommodate Up To 8 Sieves Of 20 Cm Dia. The Equipment Must Be Geared Motor Driven Of Suitable Hp. Direction Of Inclination Of Sieve Table Must Change Progressively In Clock-Wise Direction, With Both Gyratory And Tapping Motion Of Table. Equipment Must Be Controlled By A Proper Switching Device With Timer Facility And Emergency Stop / Start Button. Equipment Must Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Nequipment Must Be Of Good Make / Manufacture And Finish. ( Complete And Operational In All Respects ) 25 Miscellaneous Items / Glassware / Nconsumable Items / Safety 26 Superior Quality Borosilicate Bottles Of 50Ml Capacity, With Capillary Bored Glass Stopper, For Determination Of Specific Gravity Of Soil / Bitumen / Powders Etc 27 Heat Resistance Safety Glove Of Superior Nquality. 28 Natural High Grade Pigmented Heavy Duty Nlatex Hand Gloves Of Medium Size. 29 Medium Size Ss Scoops / Trowels. 30 Superior Quality And Make Heavy-Duty Led Nflash Light With Chargeable Battery. 31 Superior Quality Masks 32 Knife / Spatula. 33 Trichloroethylene. 34 Glass Beaker 1Liter Capacity 35 General Tool Box 36 Ss Container ( 1-Liters ) With Lids 37 Disposable Aluminum Foil Container 38 Traffic Diversion Cones ( Delineators ) 39 Ss Moisture Containers With Lids

BOQ

Name of Work: Supply of Laboratory/Field Equipment & Consumables as part of creating departmental facility for subsequent quality monitoring/ Material Testing at District material Testing laboratory Baramulla
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11ISS SIEVE SETS (As per Specifications of\nIS:460)\nISS GI-Frame Sieve Set. (Size 30cm dia)\na) 80 mm\nb) 63 mm\nc) 45 mm\nd) 40 mm\ne) 37.5 mm\nf) 26.5 mm\ng) 20 mm\nh) 19 mm\ni) 16 mm\nj) 13.2 mm\nk) 12.5 mm\nl) 11.2 mm\nm) 10.0 mm\nn) 9.5 mm\no) 6.3 mm\np) 5.6 mm\nq) 2.8 mm\nr) 4.75 mm\ns) 3.35 mm\nt) 2.36 mm\n(COMPLETE & OPERATIONAL IN ALL RESPECTS).\n1Set
22ISS SIEVE SETS (As per Specifications of IS:460)\nISS Brass Sieves. (Size 20cm dia); Sizes (mm/micron-µ):\na) 4.75 mm\nb) 2.36 mm\nc) 1.18 mm\nd) 0.600 mm\ne) 0.425 mm\nf) 0.300 mm\ng) 0.150 mm\nh) 0.090 mm\ni) 0.075 mm\n(COMPLETE & OPERATIONAL IN ALL RESPECTS).1Set
33PRECISION ELECTRONIC / DIGITAL\nBALANCE, with dual power operation (AC/Battery) CAS or equivalent:\nSuperior Brand Precision Digital Balance (5 Kg), capable of measuring 0.5 gm to 5 Kg with permissible error.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)2No
44PRECISION ELECTRONIC / DIGITAL\nBALANCE, with dual power operation (AC/Battery) CAS or equivalent:\nSuperior Brand Precision Digital Balance (30Kg), capable of measuring 1.0 gm to 30 Kg with permissible error.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)2No
55PRECISION INFRARED THERMOMETER\n(Fluke or superior Make)\nDigital non-contact Infrared Thermometer (Fluke or Superior Make), with backlight LCD Display, battery powered, with minimum operational temperature range of -20°C to 300°C (or better), display resolution of at least 0.1 °C/°F, suitable spectral response, Class-2 Laser power with display hold feature.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)2No
66THERMOMETER\nDigital contact type Probe Thermometer (Superior Make), battery powered, with minimum operational temperature range of - 50°C to 300°C (or better), display resolution of at least 0.1 °C/°F.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)2No
77AGGREGATE IMPACT TESTING MACHINE\n(As per Specifications of IS:9377)\nStandard Aggregate Impact Testing Machine for determination of Impact Value for small size mineral aggregates/rocks.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
88BITUMEN BINDER CENTRIFUGE\nEXTRACTOR\n(As per Relevant IS Specifications/ ASTM D 2172)\nManually operated Bitumen Binder Centrifuge extractor for bituminous mix up to\n1.5 Kg capacity, with hand speed control, with filter Paper Discs (Set of 500 sheets). Equipment must be of Good make/manufacture and finish. (COMPLETE & OPERATIONAL IN ALL RESPECTS)1No
99CONSISTENCY TEST APPARATUS\nThe test apparatus must be as per IS: 2720 Part-5, IS: 9259 relevant specifications, for determination of consistency (Liquid Limit) of soils by Casagrande Method. The apparatus must be manually operational, with counter, with IS/BS/ASTM Grooving Tools, Gauging Block.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
1010ENAMEL EI-TRAYS:\nSampling purpose Enamel Tray/Plates/Bucket of following minimum sizes.\na) 250x300 mm Tray.10No
1110.01b)450x600 mm Tray\n(COMPLETE & OPERATIONAL IN ALL RESPECTS)10No
1211FLAKINESS APPARATUS (SHAPE TEST\nAs per IS Specifications/SP-36, IS:2386 (Part 1)\nEquipment must consist of following: Thickness Gauge manufactured from heavy gauge steel with IS-Certification Stamp.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
1312ELONGATION APPARATUS (SHAPE TEST)\nAs per IS Specifications/SP-36, IS:2386 (Part 1)\nEquipment must consist of following:\nLength Gauge manufactured from superior steel, mounted on a hardwood base, with IS- Certification Stamp.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
1413cone & Bitumen Penetration Kit (IS: 1448 (Part 60), ASTM: D 937, IP: 179, BS:4698,\nASTM: D 217, IP: 50, ISO: 2137, EN:1426,\n13179-2)\nEquipment must consist of following replicable parts\na) Universal Penetrometer with adjustable head and display (1 No).\nb) Penetration cone for determination of consistency of lubricating grease and Oils (1 No).\nc) Bitumen Penetration kit consisting of penetration needle, copper transfer dish, aluminum containers (1 No).\nd) Penetration test cone for soils, with cups (1 No).\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1Set
1514SOFTENING POINT APPARATUS\n(As per IS:1205 RING AND BALL TYPE):\nEquipment must be Capable for determining temperature at which a sample of bituminous specifically loaded will achieve certain degree of softening. Apparatus must have arrangement for magnetic stirring of water bath, adjustable heating system with digital display of temperature.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
1615CLEVELAND Flash (Open) & Fire point Apparatus.\n(As per specification of IS:1448, P:69, IS: 73- 2013)\nEquipment must be Capable for determining flash & fire point of Bitumen. The flash cup must be made of brass with insulated handle. Equipment must have a metal heating plate electrically operated with energy regulator & gas-jet assembly (COMPLETE IN ALL RESPECTS with all\noptional accessories).1No
1716ABSOLUTE (DYNAMIC) & KINEMATIC VISCOSITY APPARATUS (As per IS Specifications 1206 Part-II & part-III, IS:73- 2013) Equipment must comprise of following\na) 2-No Imported Viscometer Tubes (Cannon-Manning Vacuum Viscometer) made of borosilicate glass with Size No:12 (IS: 1206-Part-II) for determination of Absolute Viscosity in the range of 300 to 8000 poise at 60°C, along with Calibration Certificate.\nb) 2-No Imported Viscometer Tubes (Cannon-Fenske Viscometer) made of borosilicate glass with Size No:350 (IS: 1206-Part-II) for determination of Kinematice Viscosity in the range of 30 to 500 cSt at 135°C, along with Calibration Certificate.\nc) 1-No Oil Free Vacuum application System with 4- Lines, with vacuum range up to 300mm of Hg, and least measurable and maintainable level of ±0.5mm of Hg.\nd) 3-No Mercury in glass tube type thermometer with range of 0°C to 150°C, Scale ± 0.2°C (As per IS: 1206 Part-II)\ne) 1-No Viscometer Silicon Bath, with uniform temperature maintenance system, using Accurate PDI Temperature Controller with accuracy of ±1° C, for conduction of Absolute & Kinematic Viscosity Test on bituminous and cut-back materials by vacuum capillary method at specified temperatures.(COMPLETE & OPERATIONAL IN ALL RESPECTS with all optional accessories).1Set
1817THICKNESS GAUGE\nMS Thickness Gauge with minimum gauging depth of 150mm\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)2No
1918HYDROMETER:\nAs per IS Specifications/SP-36, IS:2720 (Part 4), IS:3014.\n(For Soils/Fines with >10% passing 75 micron sieve)\nSoil Hydrometer made of superior clear/transparent glass of uniform clarity throughout the upper density scale end. The density scale range must be 0.995 to 1.30 g/cc (g/ml) at 27°C, with least count of 0.0005 g/cc (g/ml). There shall be no abrupt changes in the cross section of the hydrometer, such as will hinder cleaning or permit air bubbles to be trapped. The hydrometer shall have maximum permissible scale error of plus/minus one scale division. (COMPLETE & OPERATIONAL IN ALL RESPECTS)2No
2019SOIL PYCNOMETER (As per Ref. Standard IS: 2386)\n(For Determination of Specific Gravity of clays, sands, and gravels of grain size\n<10mm.)\nEquipment must consist of 1-Kg/1-Liter superior glass bottles, with bored brass cone stopper, with locking ring and rubber seal. (COMPLETE & OPERATIONAL IN ALL RESPECTS)3No
2120ELECTRIC HOT AIR OVEN (Reputed Make)\nSuperior laboratory electric Oven, thermostatically controlled or with digital controller cum indicator with safety alarm. It must be Double Walled, with outer body made of MS Powder Coated & inner made of Stainless Steel. It must have provision for horizontal ribs for adjusting trays at any height. Equipment must have side heating/air circulating fan, to distribute the temperature range 50°C to 250°C ± 1°C, with air-ventilators. The size of oven must be 450x450x450 cm, with size tolerance ± 10mm. Equipment must operate under 220 V (±5%), 50Hz, Single Phase AC Supply Equipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL RESPECTS)1No
2221TABLE MOUNTED MARSHALL’S STABILITY APPARATUS\n(As per IS/ASTM D-1559, D-6927 Specifications) Equipment must consist of Marshals Stability Loading frame 50kN capacity (With Proving Ring), single speed with Platen Speed of 50.8mm/min (precise speed), suitable to operate on 220V, 50 Hz, Single Phase AC-Supply, Limit switch protection for both upward and downward travel,\nFollowing must be supplied with the apparatus;\na) Marshall's Steel Compaction Hammer, weight\n4.5 Kg, with a free fall of 457mm (2-No).\nb) Compaction moulds (10.16 cm dia and 7.6 cm height, for 25.4mm maximum nominal aggregate size) of steel cylindrical, with individual extension collar and base plates (3-No)\nc) Hydraulic Sample Eject (1-No).\nd) Sample Breaking Head with load transfer bar and flow measurement arrangement using dial- gauge.\ne) Compaction Pedestal comprising of steel plate capped wooden-post.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL RESPECTS)1Set
2322WATER BATH (Reputed Make)\nWater bath (12 Holes) thermostatically controlled or with digital controller cum indicator, doubled walled, inner chamber made of non-rusting /stainless steel, outer body made of SS and minimum dimensions (425x325x100)mm or better, with temperature range of 5°C to 100°C with precision of ±0.5°C, Run by 220 V (±5%), 50Hz, Single Phase AC Supply.\nEquipment must be of Good make/manufacture and finish.\n(COMPLETE & OPERATIONAL IN ALL\nRESPECTS)1No
2423MOTORISED SIEVE SHAKER\nEquipment must consist of Motorized Sieve Shaker for sieving dry granular or powdered materials/soils. it must accommodate up to 8 sieves of 20 cm dia. the equipment must be geared motor driven of suitable HP. Direction of inclination of sieve table must change progressively in clock-wise direction, with both gyratory and tapping motion of table. Equipment must be controlled by a proper switching device with timer facility and emergency stop/start button. Equipment must run by 220 V (±5%), 50Hz, Single Phase AC Supply.\nEquipment must be of Good make/manufacture and finish. (Complete and Operational in all respects)1No
2524Miscellaneous Items/ Glassware/\nConsumable Items/ Safety
2624.01Superior Quality Borosilicate bottles of 50ml Capacity, with capillary bored glass stopper, for determination of Specific Gravity of Soil/Bitumen/Powders etc5No
2724.02Heat Resistance safety glove of superior\nquality.10No
2824.03Natural high grade pigmented heavy duty\nlatex hand gloves of medium size.10No
2924.04Medium size SS Scoops/Trowels.8No
3024.05Superior quality and make Heavy-Duty LED\nflash light with chargeable battery.2No
3124.06Superior Quality Masks50No
3224.07Knife/Spatula.6No
3324.08Trichloroethylene.5Ltr
3424.09Glass Beaker 1Liter Capacity2No
3524.1General Tool Box1No
3624.11SS Container (1-liters) with lids20No
3724.12Disposable Aluminum Foil Container500No
3824.13Traffic Diversion Cones (Delineators)10No
3924.14SS moisture containers with lids20No

AI Tender Summary

OUR REF NO 27836802
AUTHORITY Government Departments
TENDER VALUE 8.40 Lakhs
LAST DATE 17-05-2021
Authority
Authority Name Public Works Department
Work Description Supply Of Laboratory / Field Equipment And Consumables As Part Of Creating Departmental Facility For Subsequent Quality Monitoring / Material Testing At District Material Testing Laboratory Baramulla - 1 Iss Sieve Sets ( As Per Specifications Of Nis:460 ) Niss Gi-Frame Sieve Set. ( Size 30Cm Dia ) Na ) 80 Mm Nb ) 63 Mm Nc ) 45 Mm Nd ) 40 Mm Ne ) 37.5 Mm Nf ) 26.5 Mm Ng ) 20 Mm Nh ) 19 Mm Ni ) 16 Mm Nj ) 13.2 Mm Nk ) 12.5 Mm Nl ) 11.2 Mm Nm ) 10.0 Mm Nn ) 9.5 Mm No ) 6.3 Mm Np ) 5.6 Mm Nq ) 2.8 Mm Nr ) 4.75 Mm Ns ) 3.35 Mm Nt ) 2.36 Mm N ( Complete & Operational In All Respects ) . N 2 Iss Sieve Sets ( As Per Specifications Of Is:460 ) Niss Brass Sieves. ( Size 20Cm Dia ) ; Sizes ( Mm / Micron-Μ ) : Na ) 4.75 Mm Nb ) 2.36 Mm Nc ) 1.18 Mm Nd ) 0.600 Mm Ne ) 0.425 Mm Nf ) 0.300 Mm Ng ) 0.150 Mm Nh ) 0.090 Mm Ni ) 0.075 Mm N ( Complete & Operational In All Respects ) . 3 Precision Electronic / Digital Nbalance, With Dual Power Operation ( Ac / Battery ) Cas Or Equivalent: Nsuperior Brand Precision Digital Balance ( 5 Kg ) , Capable Of Measuring 0.5 Gm To 5 Kg With Permissible Error. N ( Complete & Operational In All Nrespects ) 4 Precision Electronic / Digital Nbalance, With Dual Power Operation ( Ac / Battery ) Cas Or Equivalent: Nsuperior Brand Precision Digital Balance ( 30Kg ) , Capable Of Measuring 1.0 Gm To 30 Kg With Permissible Error. N ( Complete & Operational In All Nrespects ) 5 Precision Infrared Thermometer N ( Fluke Or Superior Make ) Ndigital Non-Contact Infrared Thermometer ( Fluke Or Superior Make ) , With Backlight Lcd Display, Battery Powered, With Minimum Operational Temperature Range Of -20°C To 300°C ( Or Better ) , Display Resolution Of At Least 0.1 °C / °F, Suitable Spectral Response, Class-2 Laser Power With Display Hold Feature. N ( Complete & Operational In All Nrespects ) 6 Thermometer Ndigital Contact Type Probe Thermometer ( Superior Make ) , Battery Powered, With Minimum Operational Temperature Range Of - 50°C To 300°C ( Or Better ) , Display Resolution Of At Least 0.1 °C / °F. N ( Complete & Operational In All Nrespects ) 7 Aggregate Impact Testing Machine N ( As Per Specifications Of Is:9377 ) Nstandard Aggregate Impact Testing Machine For Determination Of Impact Value For Small Size Mineral Aggregates / Rocks. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 8 Bitumen Binder Centrifuge Nextractor N ( As Per Relevant Is Specifications / Astm D 2172 ) Nmanually Operated Bitumen Binder Centrifuge Extractor For Bituminous Mix Up To N1.5 Kg Capacity, With Hand Speed Control, With Filter Paper Discs ( Set Of 500 Sheets ) . Equipment Must Be Of Good Make / Manufacture And Finish. ( Complete & Operational In All Respects ) 9 Consistency Test Apparatus Nthe Test Apparatus Must Be As Per Is: 2720 Part-5, Is: 9259 Relevant Specifications, For Determination Of Consistency ( Liquid Limit ) Of Soils By Casagrande Method. The Apparatus Must Be Manually Operational, With Counter, With Is / Bs / Astm Grooving Tools, Gauging Block. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 10 Enamel Ei-Trays: Nsampling Purpose Enamel Tray / Plates / Bucket Of Following Minimum Sizes. Na ) 250X300 Mm Tray. 11 B ) 450X600 Mm Tray N ( Complete & Operational In All Respects ) 12 Flakiness Apparatus ( Shape Test Nas Per Is Specifications / Sp-36, Is:2386 ( Part 1 ) Nequipment Must Consist Of Following: Thickness Gauge Manufactured From Heavy Gauge Steel With Is-Certification Stamp. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 13 Elongation Apparatus ( Shape Test ) Nas Per Is Specifications / Sp-36, Is:2386 ( Part 1 ) Nequipment Must Consist Of Following: Nlength Gauge Manufactured From Superior Steel, Mounted On A Hardwood Base, With Is- Certification Stamp. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 14 Cone & Bitumen Penetration Kit ( Is: 1448 ( Part 60 ) , Astm: D 937, Ip: 179, Bs:4698, Nastm: D 217, Ip: 50, Iso: 2137, En:1426, N13179-2 ) Nequipment Must Consist Of Following Replicable Parts Na ) Universal Penetrometer With Adjustable Head And Display ( 1 No ) . Nb ) Penetration Cone For Determination Of Consistency Of Lubricating Grease And Oils ( 1 No ) . Nc ) Bitumen Penetration Kit Consisting Of Penetration Needle, Copper Transfer Dish, Aluminum Containers ( 1 No ) . Nd ) Penetration Test Cone For Soils, With Cups ( 1 No ) . Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 15 Softening Point Apparatus N ( As Per Is:1205 Ring And Ball Type ) : Nequipment Must Be Capable For Determining Temperature At Which A Sample Of Bituminous Specifically Loaded Will Achieve Certain Degree Of Softening. Apparatus Must Have Arrangement For Magnetic Stirring Of Water Bath, Adjustable Heating System With Digital Display Of Temperature. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 16 Cleveland Flash ( Open ) & Fire Point Apparatus. N ( As Per Specification Of Is:1448, P:69, Is: 73- 2013 ) Nequipment Must Be Capable For Determining Flash & Fire Point Of Bitumen. The Flash Cup Must Be Made Of Brass With Insulated Handle. Equipment Must Have A Metal Heating Plate Electrically Operated With Energy Regulator & Gas-Jet Assembly ( Complete In All Respects With All Noptional Accessories ) . 17 Absolute ( Dynamic ) & Kinematic Viscosity Apparatus ( As Per Is Specifications 1206 Part-Ii & Part-Iii, Is:73- 2013 ) Equipment Must Comprise Of Following Na ) 2-No Imported Viscometer Tubes ( Cannon-Manning Vacuum Viscometer ) Made Of Borosilicate Glass With Size No:12 ( Is: 1206-Part-Ii ) For Determination Of Absolute Viscosity In The Range Of 300 To 8000 Poise At 60°C, Along With Calibration Certificate. Nb ) 2-No Imported Viscometer Tubes ( Cannon-Fenske Viscometer ) Made Of Borosilicate Glass With Size No:350 ( Is: 1206-Part-Ii ) For Determination Of Kinematice Viscosity In The Range Of 30 To 500 Cst At 135°C, Along With Calibration Certificate. Nc ) 1-No Oil Free Vacuum Application System With 4- Lines, With Vacuum Range Up To 300Mm Of Hg, And Least Measurable And Maintainable Level Of ±0.5Mm Of Hg. Nd ) 3-No Mercury In Glass Tube Type Thermometer With Range Of 0°C To 150°C, Scale ± 0.2°C ( As Per Is: 1206 Part-Ii ) Ne ) 1-No Viscometer Silicon Bath, With Uniform Temperature Maintenance System, Using Accurate Pdi Temperature Controller With Accuracy Of ±1° C, For Conduction Of Absolute & Kinematic Viscosity Test On Bituminous And Cut-Back Materials By Vacuum Capillary Method At Specified Temperatures. ( Complete & Operational In All Respects With All Optional Accessories ) . 18 Thickness Gauge Nms Thickness Gauge With Minimum Gauging Depth Of 150Mm N ( Complete & Operational In All Nrespects ) 19 Hydrometer: Nas Per Is Specifications / Sp-36, Is:2720 ( Part 4 ) , Is:3014. N ( For Soils / Fines With >10% Passing 75 Micron Sieve ) Nsoil Hydrometer Made Of Superior Clear / Transparent Glass Of Uniform Clarity Throughout The Upper Density Scale End. The Density Scale Range Must Be 0.995 To 1.30 G / Cc ( G / Ml ) At 27°C, With Least Count Of 0.0005 G / Cc ( G / Ml ) . There Shall Be No Abrupt Changes In The Cross Section Of The Hydrometer, Such As Will Hinder Cleaning Or Permit Air Bubbles To Be Trapped. The Hydrometer Shall Have Maximum Permissible Scale Error Of Plus / Minus One Scale Division. ( Complete & Operational In All Respects ) 20 Soil Pycnometer ( As Per Ref. Standard Is: 2386 ) N ( For Determination Of Specific Gravity Of Clays, Sands, And Gravels Of Grain Size N<10Mm. ) Nequipment Must Consist Of 1-Kg / 1-Liter Superior Glass Bottles, With Bored Brass Cone Stopper, With Locking Ring And Rubber Seal. ( Complete & Operational In All Respects ) 21 Electric Hot Air Oven ( Reputed Make ) Nsuperior Laboratory Electric Oven, Thermostatically Controlled Or With Digital Controller Cum Indicator With Safety Alarm. It Must Be Double Walled, With Outer Body Made Of Ms Powder Coated & Inner Made Of Stainless Steel. It Must Have Provision For Horizontal Ribs For Adjusting Trays At Any Height. Equipment Must Have Side Heating / Air Circulating Fan, To Distribute The Temperature Range 50°C To 250°C ± 1°C, With Air-Ventilators. The Size Of Oven Must Be 450X450x450 Cm, With Size Tolerance ± 10Mm. Equipment Must Operate Under 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply Equipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Respects ) 22 Table Mounted Marshall’S Stability Apparatus N ( As Per Is / Astm D-1559, D-6927 Specifications ) Equipment Must Consist Of Marshals Stability Loading Frame 50Kn Capacity ( With Proving Ring ) , Single Speed With Platen Speed Of 50.8Mm / Min ( Precise Speed ) , Suitable To Operate On 220V, 50 Hz, Single Phase Ac-Supply, Limit Switch Protection For Both Upward And Downward Travel, Nfollowing Must Be Supplied With The Apparatus; Na ) Marshalls Steel Compaction Hammer, Weight N4.5 Kg, With A Free Fall Of 457Mm ( 2-No ) . Nb ) Compaction Moulds ( 10.16 Cm Dia And 7.6 Cm Height, For 25.4Mm Maximum Nominal Aggregate Size ) Of Steel Cylindrical, With Individual Extension Collar And Base Plates ( 3-No ) Nc ) Hydraulic Sample Eject ( 1-No ) . Nd ) Sample Breaking Head With Load Transfer Bar And Flow Measurement Arrangement Using Dial- Gauge. Ne ) Compaction Pedestal Comprising Of Steel Plate Capped Wooden-Post. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Respects ) 23 Water Bath ( Reputed Make ) Nwater Bath ( 12 Holes ) Thermostatically Controlled Or With Digital Controller Cum Indicator, Doubled Walled, Inner Chamber Made Of Non-Rusting / Stainless Steel, Outer Body Made Of Ss And Minimum Dimensions ( 425X325x100 ) Mm Or Better, With Temperature Range Of 5°C To 100°C With Precision Of ±0.5°C, Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Nequipment Must Be Of Good Make / Manufacture And Finish. N ( Complete & Operational In All Nrespects ) 24 Motorised Sieve Shaker Nequipment Must Consist Of Motorized Sieve Shaker For Sieving Dry Granular Or Powdered Materials / Soils. It Must Accommodate Up To 8 Sieves Of 20 Cm Dia. The Equipment Must Be Geared Motor Driven Of Suitable Hp. Direction Of Inclination Of Sieve Table Must Change Progressively In Clock-Wise Direction, With Both Gyratory And Tapping Motion Of Table. Equipment Must Be Controlled By A Proper Switching Device With Timer Facility And Emergency Stop / Start Button. Equipment Must Run By 220 V ( ±5% ) , 50Hz, Single Phase Ac Supply. Nequipment Must Be Of Good Make / Manufacture And Finish. ( Complete And Operational In All Respects ) 25 Miscellaneous Items / Glassware / Nconsumable Items / Safety 26 Superior Quality Borosilicate Bottles Of 50Ml Capacity, With Capillary Bored Glass Stopper, For Determination Of Specific Gravity Of Soil / Bitumen / Powders Etc 27 Heat Resistance Safety Glove Of Superior Nquality. 28 Natural High Grade Pigmented Heavy Duty Nlatex Hand Gloves Of Medium Size. 29 Medium Size Ss Scoops / Trowels. 30 Superior Quality And Make Heavy-Duty Led Nflash Light With Chargeable Battery. 31 Superior Quality Masks 32 Knife / Spatula. 33 Trichloroethylene. 34 Glass Beaker 1Liter Capacity 35 General Tool Box 36 Ss Container ( 1-Liters ) With Lids 37 Disposable Aluminum Foil Container 38 Traffic Diversion Cones ( Delineators ) 39 Ss Moisture Containers With Lids
Basic Detail
Tender No 07/1280-89/2020-21/RnB/Bla Dated 06.05.2021
Bidding Type Tender
Location
City Baramulla
State Jammu And Kashmir
Key Dates
Publish Date 07 May 2021
Submission Date 17 May 2021
Open Date 18 May 2021
Finance
Tender Value 8.40 Lakhs
Tender Fee 600
EMD 25200
Exemption Not Available
Document List
Tendernotice_1.pdf
3287405B-78FA-42BA-B12A-7DACF582F271.html
BOQ_241523.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 07, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
May 17, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 18, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

3287405B-78FA-42BA-B12A-7DACF582F271.html

xls

BOQ_241523.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders