Tripura State Electricity Corporation Limited-TSECL has published Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv /11Kv / Lt Lines In Tripura Package Iii Lot 2 Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv /11Kv / Lt Lines In Tripura Package Iii Lot 2. Submission Date for this Tender is 07-07-2021. Overhead Line Tenders in Across the State of Tripura Tripura. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-May-2021 | Corrigendum for online pre bid meeting | Other | 21-06-2021 |
2 | 04-Jun-2021 | Time Extension | Date | 29-06-2021 |
3 | 07-Jun-2021 | BoQ Corrigendum | BOQ | 29-06-2021 |
4 | 23-Jun-2021 | Time Extension2 | Date | 07-07-2021 |
5 | 29-Jun-2021 | Technical Bid Corrigendum | Technical Bid | 07-07-2021 |
6 | 30-Jun-2021 | Modified Corrigendum | Technical Bid | 07-07-2021 |
Sl. No. | Item Description |
1 | Schedule A3 : Schedule of Quantities for construction of new 33 kV Covered Conductor Single Circuit Lines |
2 | Galvanized Steel Tubular Pole 540 SP-66 - 12 mtrs (For Cradle Guarding for line crossing ) |
3 | Galvanized Steel Tubular Pole 540 SP-57 - 11 mtrs |
4 | G.I. Channel cross arm 100x50x6x3150 mm |
5 | GI Channel top bracket, 100x50×6×310mm (for top pin insulator) |
6 | G.I Channel cross arm 100x50x6x1570 mm |
7 | Cross arm bottom Support GI V bracket , Type C12-V (for single pole cross arm) |
8 | 33 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories |
9 | 33 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories |
10 | Insulating Piercing Connector - 33 kV CC to CC (100 sqmm) |
11 | 33KV Composite (Polymeric) Pin Insulatortie top type including all accessories |
12 | Non-metallic helical ties for covered conductor |
13 | Insulating Piercing Connector for 33 kV CC (100 sqmm CC- 8 SWG GI wire for LA ) |
14 | Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer |
15 | Insulated Tension Mid Span Joint /Repair Sleeve for 33 kV Covered Conductor (100 sqmm) |
16 | Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm) |
17 | 33 kV 100 sqmm Covered Conductor End Seal Caps, heat or cold shrink type |
18 | 33KVCovered Conductor Triple Layer Type with AAAC 100 Sqmm (or 99 sqmm) conductor |
19 | 33 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C12-XB) |
20 | G.I. Earth pipe, 40mm dia x 2.5 mt. Longwith earth conductor clamp including eathing compound for earth pit backfill |
21 | G.I. Wire 8 SWG for earthing |
22 | H.T. galvanized stay setincluding anchor plate (300x300x8), nut bolts,turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete |
23 | H.T. Guy insulator 88KN |
24 | G.I Stay wire 7/10 SWG |
25 | 33KV Danger plate with clamps |
26 | G.ITop Pole Clamp- Type C12-1 |
27 | G.IMiddle Pole Clamp - Type C12-2 |
28 | G.IBottom Pole clamp - Type C12-3 |
29 | G.I Stay Clamp - Type C12-S |
30 | G.I. Nuts & bolts with spring washers- assorted sizes |
31 | G.I Barbed wire 12 SWG |
32 | Stone Pad, 450x450x50 mm |
33 | Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm |
34 | Concreting Materials, M15 Grade, 0.2 cum per stay |
35 | Painting Materials for pole numbering per pole (Area 150 x 200 mm) |
36 | MANDATORY SPARE PARTS |
37 | Insulated Tension Mid Span Joint /Repair Sleeve for Covered Conductor (100 sqmm) |
38 | 33KVCovered Conductor AAAC 100 Sqmm (or 99 sqmm) |
39 | Insulating Piercing Connector for 33 kV CC- CC to CC (100 sqmm) |
40 | Insulating Piercing Connector for 33 kV CC -100 sqmm- Earthing (8 SWG) |
41 | Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm) |
42 | Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer |
43 | SSchedule A4 : Schedule of Quantities for new11 kV Covered Conductor S/C Lines including existing line replacements |
44 | Galvanized Steel Tubular Pole 540 SP-57 - 11 mtrs |
45 | G.I. Channel cross arm 100x50x6x2200 mm |
46 | GI Channel top bracket, 100x50×6×310mm (for top pin insulator) |
47 | G.I Channel cross arm 100x50x6x1570 mm |
48 | Cross arm bottom Support GI V bracket , Type C11-V (for single pole cross arm) |
49 | 11 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories |
50 | 11 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories |
51 | Insulating Piercing Connector for 11 kV CC to CC (70 sqmm) |
52 | 11KV Composite (Polymeric) Pin Insulatortie top type including all accessories |
53 | Non-metallic helical ties for covered conductor |
54 | Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for LA |
55 | Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer |
56 | Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm) |
57 | Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm) |
58 | 11KVCovered Conductor Triple Layer Type with AAAC 70 Sqmm conductor |
59 | 11 kV 70 sqmm Covered Conductor End Seal Caps, heat or cold shrink type |
60 | 11 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C11-XB) |
61 | G.I. Earth pipe, 40mm dia x 2.5 mt. Longwith earth conductor clamp including eathing compound for earth pit backfill |
62 | G.I. Wire 8 SWG (for earthing) |
63 | H.T. galvanized stay setincluding anchor plate (300x300x8 mm), nut bolts,turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete |
64 | H.T. Guy insulator 88KN |
65 | G.I Stay wire 7/10 SWG |
66 | 11 kV Danger plate with clamps |
67 | G.ITop Pole Clamp- Type C11-1 |
68 | G.IMiddle Pole Clamp - Type C11-2 |
69 | G.IBottom Pole clamp - Type C11-3 |
70 | G.I Stay Clamp - Type C11-S |
71 | G.I. Nuts & bolts with spring washers- assorted sizes |
72 | G.I Barbed wire 12 SWG |
73 | Stone Pad, 450x450x50 mm |
74 | Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm |
75 | Concreting Materials, M15 Grade, 0.2 cum per stay |
76 | Painting Materials for pole numbering per pole (Area 150 x 200 mm) |
77 | ADDITIONAL ITEMS FORCRADLE GUARDING FOR LINE CROSSING (0.5X0.33 m GI wire mesh, Double Pole Section - 50 MTR) - 01 NO PER 6 CKM |
78 | G.I. Guard Angles (65×65x6mm-2.2 m) |
79 | G.I. Flat back clamp (50x6xmm - 2.2 m) |
80 | G.I. Eye Bolt-16 mm |
81 | G.I . Turn Buckle |
82 | G.I. Wire 8 SWG (for guarding and grounding ) |
83 | G.I. wire 6 SWG (for guarding) |
84 | MANDATORY SPARE PARTS |
85 | Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm) |
86 | 11KVCovered Conductor Triple Layer Type with AAAC 70 Sqmm conductor |
87 | Insulating Piercing Connector for 11 kV CC to CC (70 sqmm) |
88 | Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for earthing |
89 | Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm) |
90 | 11 kV Covered Conductor End Seal Caps, heat or cold shrink type |
91 | Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer |
92 | Schedule A5 : Schedule of Quantities for New LT ABC Lines and Conversion of existing LT lines to AB Conductor Lines |
93 | Galvanized Steel Tubular Pole 540 SP-33 - 9 mtrs |
94 | 1.1 kV XLPE/Al Cable with one Street LTG conductor and AAAC insulated messenger neutral - 3x70 sqmm + 1x50 sqmm + 1x16 sqmm |
95 | Anchoringclamp wedge type for ABC -3x70+1x50+1x16 sqmm (for terminations, large angles & branch lines) |
96 | Suspension clamp for ABC - 3x70+1x50+1x16 sqmm |
97 | Eye Hook for ABC anchoring / suspension clamps |
98 | GI Pole Clamps / Double SS straps for fixing Eye Hook to existing 8 m PCC Poles including GI B&N / Strap Buckles |
99 | GI Pole Clamps / Double SS straps for fixing Eye Hook to 8 m STP Poles including GI B&N / Strap Buckles |
100 | Pre- insulated mid span jointing sleeves - 1 set forABC - 3x70+1x50+1x16 sqmm |
101 | Pre-moldedpush on type end capsfor ABC - 3x70+1x50+1x16 sqmm |
102 | Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm |
103 | Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection) |
104 | Single phase LTABC Distribution Box1 incoming / 6 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole |
105 | Three phase LTABC Distribution Box 1 incoming / 4 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole |
106 | Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm |
107 | Insulated piercing connector for main - st lighting taps / earthing 16 -95 / 4-35 sqmm |
108 | 1x25 sqmm Al/PVC cable |
109 | 1x35 sqmm Al/PVC cable |
110 | Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse linksrated as recommended for thermal capacity of AB cable and solid link for neutral, pole mounting type with pole mounting brackets / double SS strapsfor STP / PCC poles |
111 | Pre-insulated lugs with bolts and nuts for 70 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards |
112 | Pre-insulated lugs with bolts and nuts for 50 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards |
113 | Pre-insulated lugs with bolts and nuts for 16 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards |
114 | 2Cx6 sqmm Al/ PVC/PVC service cable |
115 | 4Cx10 sqmm Al/ PVC/PVC service cable |
116 | L.T. galvanized stay setincluding anchor plate (300x300x8), nut bolts,turn buckles,1.8 m long 16 mm dia. Solid GS Stay Rod, Thimble complete |
117 | L.T. Guy insulator |
118 | G.I Stay wire 7/12 SWG |
119 | GI Stay Clamps for 8 m STP / PCC Poles including bolts & Nuts |
120 | G.I Barbed wire 12 SWG |
121 | 20 mm dia, 1.8 mtr long GI Earth Rod includingconnecting clamps , bolts & nuts etc. |
122 | G.I. Wire 8 SWG (for earthing) |
123 | Stone Pad, 300x300x50 mm |
124 | Concreting Materials, M15 Grade, 0.25 cum per pole including muffling above GL 300 mm |
125 | Concreting Materials, M15 Grade, 0.2 cum per stay |
126 | Painting Materials for pole numbering per pole (Area 100 x 150 mm) |
127 | MANDATORY SPARE PARTS |
128 | Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm |
129 | Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection) |
130 | Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm |
131 | Insulated piercing connector for main - st lighting taps, 16 -95 / 4-35 sqmm |
132 | Pre- insulated mid span jointing sleeves - 1 set forABC - 3x70+1x50+1x16 sqmm |
133 | Single phase LTABC Distribution Box1 incoming / 6 outgoing including accessories and clamps for fixing with STP/PCC pole |
134 | Three phase LTABC Distribution Box 1 incoming / 4 outgoing including accessories and clamps for fixing with STP/PCC pole |
135 | Pre-moldedpush on type end capsfor ABC - 3x70+1x50+1x16 sqmm |
136 | Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse links rated as recommended for thermal capacity of AB cable, pole mounting type with pole mounting brackets / double SS strapsfor STP / PCC poles |
137 | Insulated Operating Rod for Outdoor Three Phase Fuse-Switch-Disconnector |
138 | HRC fuse links with blade contacts with fuse rating as per ABC manufacturer recommendations |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy