Distribution System Improvement Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv / 11Kv / Lt Lines In Tripura -Package Ii- Lot 3, Across the State of Tripura-Tripura

Tripura State Electricity Corporation Limited-TSECL has published Distribution System Improvement Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv / 11Kv / Lt Lines In Tripura -Package Ii- Lot 3. Submission Date for this Tender is 03-07-2021. Overhead Line Tenders in Across the State of Tripura Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

27825794
Corrigendum : Distribution System Improvement Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv / 11Kv / Lt Lines In Tripura -Package Ii- Lot 3
Open Tender
Indian
Tripura
Across the State of Tripura
03-07-2021

Tender Details

Distribution System Improvement Turnkey Contract For Supply And Construction Of New / Augmentation Of 33Kv / 11Kv / Lt Lines In Tripura -Package Ii- Lot 3

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-May-2021 Corrigendum for Online Pre Bid Meeting Other 18-06-2021
2 21-May-2021 Corrigendum Tech1 Technical Bid 18-06-2021
3 02-Jun-2021 Corrigendum for Time Extension Date 25-06-2021
4 07-Jun-2021 BoQ Corrigendum BOQ 25-06-2021
5 23-Jun-2021 Time Extension2 Date 03-07-2021
6 29-Jun-2021 Technical Bid Corrigendum Technical Bid 03-07-2021
7 30-Jun-2021 Modified Corrigendum Technical Bid 03-07-2021

Key Value

Document Fees
INR 25000 /-
EMD
INR 10500000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Distribution System Improvement: Turnkey contract for Supply & Construction of New / Augmentation of 33KV /11KV / LT lines in Tripura -Package-II
Sl. No. Item Description
1Sch-A2 :Schedule of Quantities for 11 kV UG Cable Lines ( New and Conversion of Existing OH Lines)
26.35/11 kV (E)grade,Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 240 Sqmm
3Termination kit for11 kV Grade, 3-core, 240 Sq.mm, Al conductor, Tr-XLPE insulated, screened, armoured, PVC sheathed power cable,outdoor / heat-shrinkable type including screen and armour earth kits, all accessories andlugs.
4Straight through jointing kit for 11 kV Grade, 3-core, 240 Sq.mm,Al conductor, Tr-XLPE insulated , screened, armoured, PVC sheathed power cable,cold-shrink type including termite proofing mesh and all accessories
5125 mm dia HDPE pipe, PE-100 material grade, SDR 19, wall thickness 7.4 mm (min) inclusing coupling as required.
6GI pipe , medium class, 125 mm dia. (For Road Crossings)
7Duct sealing material / kit for duct dia 125 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables .
8RCC Cable Protection Tiles 500 X 250X 35mmwith"DANGER - ELECTRICITY" mark
9Cable route marker, plate type 100 mm dia with 60 cm shaft with helix, Marking " 11 kV Cable" and direction arrows.
10Cable Termination at Substations / DTR on existing single / double pole structures
1111 kV lightning Arrestertor (Distribution Class), 9 kV, 10 KA with earth lead disconnector and GI mounting frame, GI bolts and nuts and all accessories
12G.I. Channel cross arm 100x50x6x2200 mm
13UPG Clamp for ACSR Racoon conductor
14G.I. Earth pipe, 40mm dia x 2.5 mt. Longwith earth conductor clamp including eathing compound for earth pit backfill
15G.I. Wire 8 SWG for earthing
16Corrugated flexible protection conduit for electrical cables, 125 mm dia, polyamide or other UV andabrasion-resistant material, including cable glands
17GI pipe , medium class, 125 mm dia.
18C-clamp for GI Pipe, 50x5 mm, 125 mm Dia
19G.ITop Pole Clamp- Type C11-1
20G.I. Nuts & bolts with spring washers- assorted sizes
21Mandatory Spares, tools and instruments
226.35/11 kV (E)grade,Al conductor, TR-XLPE insulated, Cu tape screened, armoured, PVC sheathed power cable : 3-core/ 240 Sqmm
23Duct sealing material / kit for duct dia 125 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for PVC / HDPE sheathed cables .
24Schedule A3 : Schedule of Quantities for construction of new 33 kV Covered Conductor Single Circuit Lines
25Galvanized Steel Tubular Pole 540 SP-66 - 12 mtrs (For Cradle Guarding for line crossing )
26Galvanized Steel Tubular Pole 540 SP-57 - 11 mtrs
27G.I. Channel cross arm 100x50x6x3150 mm
28GI Channel top bracket, 100x50×6×310mm (for top pin insulator)
29G.I Channel cross arm 100x50x6x1570 mm
30Cross arm bottom Support GI V bracket , Type C12-V (for single pole cross arm)
3133 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories
3233 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories
33Insulating Piercing Connector - 33 kV CC to CC (100 sqmm)
3433KV Composite (Polymeric) Pin Insulatortie top type including all accessories
35Non-metallic helical ties for covered conductor
36Insulating Piercing Connector for 33 kV CC (100 sqmm CC- 8 SWG GI wire for LA )
37Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer
38Insulated Tension Mid Span Joint /Repair Sleeve for 33 kV Covered Conductor (100 sqmm)
39Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm)
4033 kV 100 sqmm Covered Conductor End Seal Caps, heat or cold shrink type
4133KVCovered Conductor Triple Layer Type with AAAC 100 Sqmm (or 99 sqmm) conductor
4233 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C12-XB)
43G.I. Earth pipe, 40mm dia x 2.5 mt. Longwith earth conductor clamp including eathing compound for earth pit backfill
44G.I. Wire 8 SWG for earthing
45H.T. galvanized stay setincluding anchor plate (300x300x8), nut bolts,turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete
46H.T. Guy insulator 88KN
47G.I Stay wire 7/10 SWG
4833KV Danger plate with clamps
49G.ITop Pole Clamp- Type C12-1
50G.IMiddle Pole Clamp - Type C12-2
51G.IBottom Pole clamp - Type C12-3
52G.I Stay Clamp - Type C12-S
53G.I. Nuts & bolts with spring washers- assorted sizes
54G.I Barbed wire 12 SWG
55Stone Pad, 450x450x50 mm
56Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm
57Concreting Materials, M15 Grade, 0.2 cum per stay
58Painting Materials for pole numbering per pole (Area 150 x 200 mm)
59MANDATORY SPARE PARTS
60Insulated Tension Mid Span Joint /Repair Sleeve for Covered Conductor (100 sqmm)
6133KVCovered Conductor AAAC 100 Sqmm (or 99 sqmm)
62Insulating Piercing Connector for 33 kV CC- CC to CC (100 sqmm)
63Insulating Piercing Connector for 33 kV CC -100 sqmm- Earthing (8 SWG)
64Insulating Piercing Connector for 33 kV CC (100 sqmm) to Bare ( 75-150 sqmm)
65Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),30 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 25 kV or as recommended by CC manufacturer
66SSchedule A4 : Schedule of Quantities for new11 kV Covered Conductor S/C Lines including existing line replacements
67Galvanized Steel Tubular Pole 540 SP-57 - 11 mtrs
68G.I. Channel cross arm 100x50x6x2200 mm
69GI Channel top bracket, 100x50×6×310mm (for top pin insulator)
70G.I Channel cross arm 100x50x6x1570 mm
71Cross arm bottom Support GI V bracket , Type C11-V (for single pole cross arm)
7211 kV Composite (Polymer) Tension Insulator, 45 kN with all accessories
7311 kV Composite Insulator Tension Hardware, 45 kN suitable for stringing covered conductor including all accessories
74Insulating Piercing Connector for 11 kV CC to CC (70 sqmm)
7511KV Composite (Polymeric) Pin Insulatortie top type including all accessories
76Non-metallic helical ties for covered conductor
77Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for LA
78Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer
79Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm)
80Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm)
8111KVCovered Conductor Triple Layer Type with AAAC 70 Sqmm conductor
8211 kV 70 sqmm Covered Conductor End Seal Caps, heat or cold shrink type
8311 kV G.I Cross Bracing Set made of G.I angles 65x 65x 6 mm , X-type, single Tier (Type : C11-XB)
84G.I. Earth pipe, 40mm dia x 2.5 mt. Longwith earth conductor clamp including eathing compound for earth pit backfill
85G.I. Wire 8 SWG (for earthing)
86H.T. galvanized stay setincluding anchor plate (300x300x8 mm), nut bolts,turn buckles,1.8 m long 20 mm dia. Solid GS Stay Rod, Thimble complete
87H.T. Guy insulator 88KN
88G.I Stay wire 7/10 SWG
8911 kV Danger plate with clamps
90G.ITop Pole Clamp- Type C11-1
91G.IMiddle Pole Clamp - Type C11-2
92G.IBottom Pole clamp - Type C11-3
93G.I Stay Clamp - Type C11-S
94G.I. Nuts & bolts with spring washers- assorted sizes
95G.I Barbed wire 12 SWG
96Stone Pad, 450x450x50 mm
97Concreting Materials, M15 Grade, 0.35 cum per pole including muffling above GL 300 mm
98Concreting Materials, M15 Grade, 0.2 cum per stay
99Painting Materials for pole numbering per pole (Area 150 x 200 mm)
100ADDITIONAL ITEMS FORCRADLE GUARDING FOR LINE CROSSING (0.5X0.33 m GI wire mesh, Double Pole Section - 50 MTR) - 01 NO PER 6 CKM
101G.I. Guard Angles (65×65x6mm-2.2 m)
102G.I. Flat back clamp (50x6xmm - 2.2 m)
103G.I. Eye Bolt-16 mm
104G.I . Turn Buckle
105G.I. Wire 8 SWG (for guarding and grounding )
106G.I. wire 6 SWG (for guarding)
107MANDATORY SPARE PARTS
108Insulated Tension Mid Span Joint /Repair Sleeve for 11 kV Covered Conductor (70 sqmm)
10911KVCovered Conductor Triple Layer Type with AAAC 70 Sqmm conductor
110Insulating Piercing Connector for 11 kV CC to CC (70 sqmm)
111Insulating Piercing Connector for 11 kV CC : 70 sqmm CC- 8 SWG GI wire for earthing
112Insulating Piercing Connector for 11 kV CC (70 sqmm) to Bare ( 75-150 sqmm)
11311 kV Covered Conductor End Seal Caps, heat or cold shrink type
114Lightning Arrester (Distribution Class) with polymer housing (suitable for CC),9 kV , 10 KA, with earth lead disconnector and channel mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer
115Schedule A5 : Schedule of Quantities for New LT ABC Lines and Conversion of existing LT lines to AB Conductor Lines
116Galvanized Steel Tubular Pole 540 SP-33 - 9 mtrs
1171.1 kV XLPE/Al Cable with one Street LTG conductor and AAAC insulated messenger neutral - 3x70 sqmm + 1x50 sqmm + 1x16 sqmm
118Anchoringclamp wedge type for ABC -3x70+1x50+1x16 sqmm (for terminations, large angles & branch lines)
119Suspension clamp for ABC - 3x70+1x50+1x16 sqmm
120Eye Hook for ABC anchoring / suspension clamps
121GI Pole Clamps / Double SS straps for fixing Eye Hook to existing 8 m PCC Poles including GI B&N / Strap Buckles
122GI Pole Clamps / Double SS straps for fixing Eye Hook to 8 m STP Poles including GI B&N / Strap Buckles
123Pre- insulated mid span jointing sleeves - 1 set forABC - 3x70+1x50+1x16 sqmm
124Pre-moldedpush on type end capsfor ABC - 3x70+1x50+1x16 sqmm
125Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm
126Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection)
127Single phase LTABC Distribution Box1 incoming / 6 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole
128Three phase LTABC Distribution Box 1 incoming / 4 outgoing including accessories and GI clamps /SS straps for fixing with STP/PCC pole
129Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm
130Insulated piercing connector for main - st lighting taps / earthing 16 -95 / 4-35 sqmm
1311x25 sqmm Al/PVC cable
1321x35 sqmm Al/PVC cable
133Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse linksrated as recommended for thermal capacity of AB cable and solid link for neutral, pole mounting type with pole mounting brackets / double SS strapsfor STP / PCC poles
134Pre-insulated lugs with bolts and nuts for 70 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards
135Pre-insulated lugs with bolts and nuts for 50 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards
136Pre-insulated lugs with bolts and nuts for 16 sqmm Al Conductors for terminating ABC cables at DTR bushing terminals or Dist. Boards
1372Cx6 sqmm Al/ PVC/PVC service cable
1384Cx10 sqmm Al/ PVC/PVC service cable
139L.T. galvanized stay setincluding anchor plate (300x300x8), nut bolts,turn buckles,1.8 m long 16 mm dia. Solid GS Stay Rod, Thimble complete
140L.T. Guy insulator
141G.I Stay wire 7/12 SWG
142GI Stay Clamps for 8 m STP / PCC Poles including bolts & Nuts
143G.I Barbed wire 12 SWG
14420 mm dia, 1.8 mtr long GI Earth Rod includingconnecting clamps , bolts & nuts etc.
145G.I. Wire 8 SWG (for earthing)
146Stone Pad, 300x300x50 mm
147Concreting Materials, M15 Grade, 0.25 cum per pole including muffling above GL 300 mm
148Concreting Materials, M15 Grade, 0.2 cum per stay
149Painting Materials for pole numbering per pole (Area 100 x 150 mm)
150MANDATORY SPARE PARTS
151Insulated piercing connector for main - main connections, 25-95 / 25-95 sqmm
152Insulated piercing connector 16-35 /16-35 sqmm (for street light conductor main-main connection)
153Insulated piercing connector for main - service taps, 25-95 / 6-35 sqmm
154Insulated piercing connector for main - st lighting taps, 16 -95 / 4-35 sqmm
155Pre- insulated mid span jointing sleeves - 1 set forABC - 3x70+1x50+1x16 sqmm
156Single phase LTABC Distribution Box1 incoming / 6 outgoing including accessories and clamps for fixing with STP/PCC pole
157Three phase LTABC Distribution Box 1 incoming / 4 outgoing including accessories and clamps for fixing with STP/PCC pole
158Pre-moldedpush on type end capsfor ABC - 3x70+1x50+1x16 sqmm
159Outdoor Three Phase Fuse-Switch-Disconnector with HRC fuse links rated as recommended for thermal capacity of AB cable, pole mounting type with pole mounting brackets / double SS strapsfor STP / PCC poles
160Insulated Operating Rod for Outdoor Three Phase Fuse-Switch-Disconnector
161HRC fuse links with blade contacts with fuse rating as per ABC manufacturer recommendations
Disclaimer :