Tender Details

Dnit For Renovation Repair Of Water Works Structures Alongwith Distribution System Including Functional Household Tap Connection In Village Khasa Mahajana

Key Value

Document Fees
INR 2500 /-
EMD
INR 97320.00 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Tendernotice_2.pdf Tender Document-Tender Notice 51.32
7B4B1BF7-9655-4BF0-8B7B-FFA3CE2612B8.html Tender Notice-Tender Notice 0
dnit.pdf Tender Document-DNIT 6743.73
BOQ_226881.xls Tender Document-BOQ 318.00
Tendernotice_1.pdf Tender Document-DNIT 139.45

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work
Sl. No. Item Description NS Item Item Code / Make Quantity Units
1 1.1 Supply & erection of Horizontal spindle split casing type puming sets of following duties directly coupled to AC squirrel cage induction type motor with 1440 RMP, 3 Phase, 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame.\n(A) Raw water pump set 1100 LPM 12 mtr. head 2 No.
2 1.2 B) Clear water pump set 1100 LPM 40 mtr. Head 2 No.
3 1.3 Supply and fixing following CI D/F pipe and specials/ bell mouth/ including cost of joining materials laying jointing, refilling of including making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water pumping sets at water works in position as per specification given in schedule No.II. (i) 100 mm i/d\n\n 20 Mtr.
4 1.4 ii) 150 mm i/d 30 mtr
5 1.5 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items.\nA )For Raw water Pumpsets for 1100 LPM 12 mtr head = 2 nos. a) Main switch 63 Amp 2 No.(L&T Siemens, ABB)\nb) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T)\nC) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T)\nD) CT 100/ 3 Nos. (AE/KAPPA/L&T)\nE) VSS & ASS 4 No. of approved make\nF) SPP 4 No. of approved make\ng) Motor starter, Star delta 2 No.for 1100 LPM x 12 Mtr Head (L&T Simens. ABB)\nH) Capacity suitable capacity = 2 Nos. \nI) Indicating Lamp - One Set \nj) Change over switch 100 Amp = 1 No.\n 1 Job
6 1.6 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items.\nA )For Clear water Pumpsets for 1100 LPM 40 mtr head = 2 nos. a) Main switch 63 Amp 2 No.(L&T Siemens, ABB)\nb) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T)\nC) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T)\nD) CT 100/ 3 Nos. (AE/KAPPA/L&T)\nE) VSS & ASS 4 No. of approved make\nF) SPP 4 No. of approved make\ng) Motor starter, Star delta 2 No.for 1100 LPM x 40 Mtr Head (L&T Simens. ABB)\nH) Capacity suitable capacity = 2 Nos. \nI) Indicating Lamp - One Set \nj) Change over switch 100 Amp = 1 No.\n 1 Job
7 1.7 Supply erection testing of ISI marked copper wire for 4 Nos motors with under ground system in PVC and flexible pipes copper wire size 6 Sq. mm complete in all respects with accessories like thimble etc. 30 Mtr.
8 1.8 Supply erection testing of ISI marked copper wire for 2 Nos panel boards from main switch to panel and wiring of panel with size 10 sq. mm (copper wire ) ISI marked complete in all respects with accessories like thimble etc. complete in respects. 30 Mtr.
9 1.9 Supply ,errection testing of light fitting including wire in the Pump Chamber with material upto 10 point including switch button , plug PVC, condut pipe & copper wire etc as per approved specifications complete in respects. 1 Complete Job of 10 points
10 2 Providing & fixing Exahaust fan 18" i/d (450mm) complete with suitable GI sheet of approved Make complete in respect 1 each
11 2.1 Providing & fixing Ceiling fan 56" (1400mm) with speed adjester of reputed make complete with suitable GI sheet of approved Make.(Crompton, Usha, Bajaj, Orient etc. 1 each
12 2.2 Providing & fixing suitable floating arms along with swivel bend as per required specifications approved by Engineer-in- charge (200 mm) complete in respects 3 each
13 2.3 Supply erection, testing of reputed make LED light 100 watts with fittings and accessories complete in respects. 2 each
14 2.4 Taking out filter media from filter bed & relaying the same after screening washing & cleaning into bed intop layer to Bottom layer 185 cum
15 2.5 Less old Bricks bats / less old Bricks bats 18359 each