}

Providing Necessary Infrastructure For Buildings At Daf Taliparamba, DAF, Taliparamba-Kerala

Department Of Agriculture-DOA has published Providing Necessary Infrastructure For Buildings At Daf Taliparamba. Submission Date for this Tender is 14-05-2021. Earth Moving Machinery Tenders in DAF, Taliparamba Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

27809613
Providing Necessary Infrastructure For Buildings At Daf Taliparamba
Open Tender
Indian
Kerala
DAF, Taliparamba
14-05-2021

Tender Details

Providing Necessary Infrastructure For Buildings At Daf Taliparamba - 1 Roof Top Water Harvesting And Well Recharging For Agro Service Centre 2 2.1.1 : Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 3 2.8.1 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 4 4.1.8 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) 5 50.6.7.1 : Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20x15cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 6 2.25 : Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M.Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 7 5.1.3 : Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 8 5.9.2 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 9 5.22.6 : Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 10 13.1.1 : 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 11 18.48 : Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 12 Od1521 / 2020_2021 : :Providing And Fixing 110Mm Dia 4 Kg / Cm2 Pvc Half Round Pipe For Rain Drain Pipe Including Droper, Stopper, And Supporting Clamp @ 1.5M Spacing Etc Complete 13 Od1523 / 2020_2021 : :Supplying And Providing 110Mm Roof Water Harvesting Filter Best Quality ( Isi ) Suitable For Upto An Area Of 225 Sqm, 225 Lpm Capacity, Works In Cohesive And Centrifugal Force, Filter Element Of Ss -304 Screen, Mesh Size Of 250 Microns, Inlet 110Mm, Clean Water Outlet 75Mm, Drain Outlet 90Mm, Operating Pressure Of 0.060Kg / Cm2 Etc Complete. 14 50.18.9.19.2 : Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps / Clips At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 M Dia 4 Kgf / Cm2 - External Work - Exposed On Wall 15 50.18.9.9.2 : Providing And Fixing Pvc Pipes Includes Joints Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 110 Mm Dia 4 Kg / Cm2 16 50.18.9.22.1 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 17 50.18.9.22.4 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 18 50.18.9.22.5 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee 19 50.18.9.22.9 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia Offset 20 50.18.9.22.11 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Socket / Coupling 21 Od1524 / 2020_2021 : :Providing And Fixing 110 Mm Dia Pvc Ball Valve With Isi Specifications 22 50.18.9.12.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 10Kgf / Cm2 External Work- Exposed On Wall 23 18.15.2 : Providing And Fixing Brass Bib Cock Of Approved Quality :20 Mm Nominal Bore 24 Office Cum Sales Building Painting 25 14.43 : Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 26 14.53.1 : Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:One Or More Coats On Old Work 27 14.54.1 : Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To An Give Even Shade:One Or More Coats On Old Work 28 Roof Water Harvesting Structure 29 2.1.1 : Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 30 2.8.1 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 31 Od1542 / 2020_2021 : Earth Work In Excavation Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.≪Br≫All Kinds Of Soil 32 4.1.8 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) 33 50.6.7.1 : Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20x15cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 34 2.25 : Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M.Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 35 5.1.3 : Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 36 5.9.2 : Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 37 5.22.6 : Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 38 13.1.1 : 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 39 18.48 : Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 40 50.18.9.16.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 6Kgf / Cm2 - External Work - Exposed On Wall 41 50.18.9.18.1 : Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps / Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf / Cm2 - External Work- Exposed On Wall 42 50.18.9.19.1 : Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps / Clips / At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf / Cm2 - External Work- Exposed On Wall 43 50.18.9.9.1 : Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf / Cm2 44 Od1540 / 2020_2021 : :Supplying And Providing 110Mm Roof Water Harvesting Filter Best Quality ( Isi ) Suitable For Upto An Area Of 225 Sqm, 225 Lpm Capacity, Works In Cohesive And Centrifugal Force, Filter Element Of Ss -304 Screen, Mesh Size Of 250 Microns, Inlet 110Mm, Clean Water Outlet 75Mm, Drain Outlet 90Mm, Operating Pressure Of 0.060Kg / Cm2 Etc Complete. 45 Od1541 / 2020_2021 : Providing And Fixing - 110 Mm Dia Pvc Ball Valve With Isi Secifications 46 50.18.9.20.10 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63X50 Mm Dia Reducer 47 50.18.9.21 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Elbow 48 50.18.9.21.5 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75X75x75 Mm Dia Tee 49 50.18.9.21.10 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75X63 Mm Dia Reducer 50 50.18.9.22.1 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 51 50.18.9.22.4 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 52 50.18.9.22.5 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee 53 50.18.9.22.12 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X75 Mm Dia Reducer 54 50.18.9.12.2 : Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 10Kgf / Cm2 External Work- Exposed On Wall 55 18.15.2 : Providing And Fixing Brass Bib Cock Of Approved Quality :20 Mm Nominal Bore

Key Value

Document Fees
INR 1000 /-
EMD
INR 7500.0 /-
Tender Value
INR 4.19 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail