Replacement Of Conventional Lts Into Energy Efficient Led Lts In Arty Centre And Provn Of Prepaid Automatic Meter Reading And Billing System Software For Private Parties At Arty Centre And Aop Under Ge Nasik Road Camp As Per Tender Documents, Garrison Engineer Nasik Road-Maharashtra

Military Engineer Services-MES has published Replacement Of Conventional Lts Into Energy Efficient Led Lts In Arty Centre And Provn Of Prepaid Automatic Meter Reading And Billing System Software For Private Parties At Arty Centre And Aop Under Ge Nasik Road Camp As Per Tender Documents. Submission Date for this Tender is 27-05-2021. Accounting Software Tenders in Garrison Engineer Nasik Road Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

27790804
Corrigendum : Replacement Of Conventional Lts Into Energy Efficient Led Lts In Arty Centre And Provn Of Prepaid Automatic Meter Reading And Billing System Software For Private Parties At Arty Centre And Aop Under Ge Nasik Road Camp As Per Tender Documents
Open Tender
Indian
Maharashtra
Garrison Engineer Nasik Road
27-05-2021

Tender Details

Replacement Of Conventional Lts Into Energy Efficient Led Lts In Arty Centre And Provn Of Prepaid Automatic Meter Reading And Billing System Software For Private Parties At Arty Centre And Aop Under Ge Nasik Road Camp As Per Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-May-2021 Revised BOQ BOQ 20-05-2021
2 20-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
INR 11.52 Lakhs /-

BOQ Items

Name of Work : REPLACEMENT OF CONVENTIONAL LTS INTO ENERGY EFFICIENT LED LTS IN ARTY CENTRE AND PROVN OF PREPAID AUTOMATIC METER READING AND BILLING SYSTEM SOFTWARE FOR PRIVATE PARTIES AT ARTY CENTRE AND AOP UNDER GE NASIK ROAD CAMP
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, fix, connect and test LED street light fitting 45 W, pressure die cast aluminum housing, heat resistance toughened glass, IP 65 protection, 10 KV SPD included better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management, all as specified and directed by Engr-in-Charge. 49 Each
2 2 Supply, fix, connect and test LED street light fitting 60 W, pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, 10 KV SPD better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management, complete all as specified and directed.. 20 Each
3 3 Supply, fix, connect and test LED flood light fitting 80W, pressure die cast aluminum housing, heat resistance toughened glass, IP 66 protection, better optics for uniform distribution, aesthetically designed roadway luminiare with excellent thermal management, all as specified and directed. 5 Each
4 4 Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion 3 Each
5 5 Excavation in trenches in soft / loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, RCC poles / stays and struts etc. and getting out including trimming sides and forming bottom surface complete all as specified and directed at site. 50 Cum
6 6 Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed. 40 Cum
7 7 Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. 10 Cum
8 8 Supply, laying and testing XLPE insulated heavy duty electric cable with aluminium conductor , 1100 volts grade of size 2 core 10 sqmm all as specified and directed by Engineer-in-Charge. 200 RM
9 9 Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 25 mm suitable for cable protection complete all as specified and directed. 180 Per Rm
10 10 Taking down of old street light bracket including clamps of any type/any size from pole/wall including necessary nuts & bolts as directed complete all as specified and directed. 15 Each
11 11 M&L for fabrication and installation of GI pipe bracket made of medium grade tubing of size 40mm dia duly bended by hot forging after filling of sand, length 1.20 mtr including two pairs of MS flat strip clamps 30 x 5mm with GI bolts, nuts and washers complete all as specified and directed. 15 Each
12 12 Supply and fix junction box of Size 250 x 200 x 100mm size complete with industrial connector including clamps made out of MS flat iron 30 x 5mm including connection from junction box to street light fitting with suitable size MCB and 3 core PVC insulated & PVC sheathed copper conductor cable 1.5 sqmm size all as specified and directed. 5 Each
13 13 Same as per Above Item No. 12.00 but Size 185 x 165 x 60 mm 10 Each
14 14 Same as per Above Item No. 12.00 but Size 140 x 140 x 95 mm 10 Each
15 15 Supply and fix in repaires PVC insulated 2 core 1.5 sqmm multistranded (un armoured 2XY) copper conductor complete all as specified and directed. 450 Rm
16 16 Dismantling and taking down by disconnecting electric connection from existing serviceable / unserviceable / partly unserviceable street / security light fittings or any other light fitting of any type / any watt, fitting and fixtures etc. 74 Each
17 17 Supply and Installation of AMR Enable Single Phase Meter with the following specifications:\n• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10-60A anti tamper features. Meter should support the following data : 30 min instantaneous data for voltage, current, power factor , power cumulative energy, cumulative apparent energy and frequency. Meter should have connect/disconnect functionally operable from pre-paid billing software. Meter should have built in GPRS modem to provide connectivity with the billing software. 32 Each
18 18 Supply and installation of Three phase smart meter with the following specification :- AC Three phase four wire , Tamper proof, static meter of class 1.0, 415 V, 50 Hz, 10-60A anti-tamper features. * Meter should support the following data : 30 min instantaneous data for voltage, current, power factor , power cumulative energy, cumulative apparent energy and frequency. * Meter should have connect/disconnect functionally operable from pre-paid billing software. Meter should have built in GPRS modem to provide connectivity with the billing software. 4 Each
19 19 Hosting and Configuration of the Web based Software with following modules:\n(i) Meter Data Management Module\nThe meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data:\n(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency\n(b) Monthly and quarterly billing survey data for cumulative energy and max demand\n(ii) Prepaid Billing Module (for single phase and three phase snart meters) and max demand.\nThe billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. 36 Each Meter
20 20 Operational Cost and annual maintenance support for the software and GPRS provisioning after two years of defect liability period. 72 Each Meter Year
21 21 Supply and fix in repairs PVC insulated single core 2.5 sqmm multistranded 1100 volts aluminium conductor cable complete all as specified and directed. 100 RM
22 22 NOTE :- AMOUNT OF SCHEDULE OF CREDIT RS. 9,875.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.