| 1 | 1 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. | BI01010001010000000000000515BI0100001113 | 450 | SQM |
|---|
| 2 | 2 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. | BI01010001010000000000000515BI0100001114 | 35 | EACH |
|---|
| 3 | 3 | Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C . pan of size 580x440 mm. | BI01010001010000000000000515BI0100001115 | 35 | EACH |
|---|
| 4 | 4 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion - Single socketed pipes. - 110 mm diameter. | BI01010001010000000000000515BI0100001116 | 400 | METER |
|---|
| 5 | 5 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion - Single tee with door - 110x110x110mm. | BI01010001010000000000000515BI0100001117 | 80 | EACH |
|---|
| 6 | 6 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. | BI01010001010000000000000515BI0100001118 | 500 | SQM |
|---|
| 7 | 7 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion - Single tee with door - Bend 87.5° - 110 mm bend. | BI01010001010000000000000515BI0100001119 | 80 | SQM |
|---|
| 8 | 8 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion - Single tee with door - Shoe (Plain) - 110 mm shoe. | BI01010001010000000000000515BI0100001121 | 40 | EACH |
|---|
| 9 | 9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal outer dia Pipe | BI01010001010000000000000515BI0100001122 | 30 | METER |
|---|
| 10 | 10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 25 mm nominal outer dia Pipe | BI01010001010000000000000515BI0100001123 | 25 | METER |
|---|
| 11 | 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia Pipe. | BI01010001010000000000000515BI0100001124 | 25 | METER |
|---|
| 12 | 12 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. | BI01010001010000000000000515BI0100001125 | 100 | SQM |
|---|
| 13 | 13 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1cement: 4 fine sand). | BI01010001010000000000000515BI0100001126 | 150 | SQM |
|---|
| 14 | 14 | 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand). | BI01010001010000000000000515BI0100001127 | 200 | SQM |
|---|
| 15 | 15 | Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. | BI01010001010000000000000515BI0100001128 | 2800 | KG |
|---|
| 16 | 16 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar | BI01010001010000000000000515BI0100001129 | 12 | CUM |
|---|
| 17 | 17 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001130 | 14 | CUM |
|---|
| 18 | 18 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead :100 mm dia pipe. | BI01010001010000000000000515BI0100001131 | 250 | METER |
|---|
| 19 | 19 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’ specifications including appropriate priming coat, preparation of surface, etc. complete.On Steel work | BI01010001010000000000000515BI0100001132 | 150 | SQM |
|---|
| 20 | 20 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | BI01010001010000000000000515BI0100001133 | 20 | CUM |
|---|
| 21 | 21 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metre lead.For thickness of tiles above 10 mm and upto 25 mm | BI01010001010000000000000515BI0100001134 | 300 | SQM |
|---|
| 22 | 22 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) | BI01010001010000000000000515BI0100001135 | 400 | SQM |
|---|
| 23 | 23 | Applying one coat of water thinable cement primerof approved brand and manufacture on wall surface:water thinable cement primer | BI01010001010000000000000515BI0100001136 | 400 | SQM |
|---|
| 24 | 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001137 | 400 | SQM |
|---|
| 25 | 25 | Providing and fixing C.P Jali of approved quality in mouth of drainage pipe-100 mm dia as per instruction of EIC. | BI01010001010000000000000515BI0100001138 | 40 | EACH |
|---|
| 26 | 26 | Providing and Fixing PVC Flush Pipe Connecting flushing cistern to EWC/IWC of aprroved quality as per instruction of EIC. | BI01010001010000000000000515BI0100001139 | 40 | EACH |
|---|
| 27 | 27 | Providing and laying water proofing treatment to wallTwo coats of Dr.fixit krystalline water proofing treatment including preparation of surface by removing all damaged and loose particles. | BI01010001010000000000000515BI0100001140 | 300 | SQM |
|---|
| 28 | 28 | Dismantling all damaged and spalled concrete including derusting exposed reinforcement rods with liquid rust remover of approved quality and applying two coats anti corrosive coating of standard make and repairing of spalled RCC surface of chajja/beam/slab/column etc with polymerized cement mortar 1:4 (1 cement : 4 sand) prepared by diluted latex 1:8 (1 latex : 8 water) over a primer/bounding coat of latex slurry primer - 40mm average thickness as per instruction of EIC.Execluding the cost of scafolding. | BI01010001010000000000000515BI0100001141 | 100 | SQM |
|---|
| 29 | 29 | Total impact of GST for the purpose of CTC | BI01010001010000000000000515BI0100001189 | 1 | Nos. |
|---|