}

Supply Of Godrej Make Optimizer At Oat Office Building , Cuttack, Cuttack-Odisha

Orissa Industrial Infrastructure Development Corporation has published Supply Of Godrej Make Optimizer At Oat Office Building , Cuttack. Submission Date for this Tender is 24-05-2021. Coats and Jackets Tenders in Cuttack Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

27785956
Corrigendum : Supply Of Godrej Make Optimizer At Oat Office Building , Cuttack
Rate Contract
Indian
Odisha
Cuttack
24-05-2021

Tender Details

Supply Of Godrej Make Optimizer At Oat Office Building , Cuttack , Kd Optimizer - ( 2361 H X 915 W X 457 D ) , Sd4 457 Dr - 2361Ht , Overall Dimensions Of Sd - 4 Single Static Drive Cover Unit 4 Bay ( U / C , Fittings , Cover ) Shall Be 3660Mm ( W ) X457mm ( D ) X2361mm ( H ) . The Construction Shall Be Rigid Knock Down Construction Made Out Of 0 . 8Mm Thk For Back & Shelves And 0 . 9 Mm For Sides & Top . Finish Shall Be Epoxy Polyester Powder Coated Thickness Of 45 Microns . The Testing Of Paint Should Be Done For Various Physical & Chemical Properties As Per Is: 101 . Shelf Construction Shall Be Made From Crca Steel 0 . 8 Mm Thick Is :513 . Uniformly Distributed Load Capacity Of 80 Kg . Undercarriage Shall Have Construction In Welded Frame Made Of Hr Sheet 3 . 15 Mm Thick Conforming To Is : 1079 . Finish Shall Be Epoxy Polyester Powder Coat Of Approved Color & Shade With A Dry Film Thickness Of Minimum 45 Microns . The Movements Shall Be Drive Type Configuration : In Case Of D4 & D5 Movement Of Units Is Achieved Mechanically Through A Drive Wheel And 2 Stage Sprocket -Chain-Tensioner Arrangement Mounted Rigidly Onto Body Size . For D4 Each Movable Undercarriage Shall Be Provided With 3 Rollers On The Shaft For Driving , 3 Antifriction Ball Bearing For Rolling And 4 Antifriction Ball Bearing For Guiding Between Rail . Fittings Shall Be Centralized Locking Arrangement Through Locking Stiffener Mounted Onto Back Of Single Last Unit So That It Gets Locked On Channels When All The Units Are Brought Together . The Recess Handle Lock Is Of Godrej Make & Placed At Suitable Height . This Arrangement Occupies A Space Of 90 . 0 Mm . When The Last Unit Is Twin Movable , Hinged Doors Are Provided For The End Bodies , So In This Case Locking Stiffener Is Mounted Onto Drive Unit Cover ; And With Tile Fascia Option , It Will Be Mounted In The Recess Of Vertical Trim . Each Drive Type Units Shall Have Locking Knob Near The Drive Wheel For Manual Locking Of Individual Units When A Person Is Using Those Units . Knob Shall Be Rotated To Unlock Position When Units Are To Be Moved . End Stoppers Shall Be Provided To Prevent Derailment . Door Locking Shall Be Having Hinged Doors Of Recessed Die Cast Handle Cum Lock Giving 3 Way Locking Through A Lever & Shooting Bolts . Guide Channels Shall Have J Section 2 Mm Thick Hr & 25 Mm Square Bright Bar . Easteners Shall Be Galvanized / Blackodized / Zn Plated . The Label Holder Shall Be Made From 2 Mm Thick Clear Transparent Acrylic Sheet . Also Total No . Of Loading Levels Per Understructure Shall Be 24 For Sd4 . Fascia ( Tiling ) 3 Tile Pattern Fascia Option On Drive Side Panel Plus 3 Tile Pattern Fascia On Non-Drive Side Panel Plus 3 Tile Pattern Fascia Option On Back Panel Of Single Last Plus 3 Tile Pattern Fascia Option On Back Panel Of Single Static . The Tiles Are Held Together By Stiffeners & Fasteners In 2 Vertical Metal Trims . , Ld4 457 Dr - 2361H , Overall Dimensions Of Ld - 4 Single Last Drive Unit 4 Bay ( U / C , Fittings , Cover ) Shall Be 3660Mm ( W ) X457mm ( D ) X2361mm ( H ) . The Construction Shall Be Rigid Knock Down Construction Made Out Of 0 . 8Mm Thk For Back & Shelves And 0 . 9 Mm For Sides & Top . Finish Shall Be Epoxy Polyester Powder Coated Thickness Of 45 Microns . The Testing Of Paint Should Be Done For Various Physical & Chemical Properties As Per Is: 101 . Shelf Construction Shall Be Made From Crca Steel 0 . 8 Mm Thick Is :513 . Uniformly Distributed Load Capacity Of 80 Kg . Undercarriage Shall Have Construction In Welded Frame Made Of Hr Sheet 3 . 15 Mm Thick Conforming To Is : 1079 . Finish Shall Be Epoxy Polyester Powder Coat Of Approved Color & Shade With A Dry Film Thickness Of Minimum 45 Microns . The Movements Shall Be Drive Type Configuration : In Case Of D4 Movement Of Units Is Achieved Mechanically Through A Drive Wheel And 2 Stage Sprocket -Chain-Tensioner Arrangement Mounted Rigidly Onto Body Size . For D4 Each Movable Undercarriage Shall Be Provided With 3 Rollers On The Shaft For Driving , 3 Antifriction Ball Bearing For Rolling And 4 Antifriction Ball Bearing For Guiding Between Rail . Fittings Shall Be Centralized Locking Arrangement Through Locking Stiffener Mounted Onto Back Of Single Last Unit So That It Gets Locked On Channels When All The Units Are Brought Together . The Recess Handle Lock Is Of Godrej Make & Placed At Suitable Height . This Arrangement Occupies A Space Of 90 . 0 Mm . When The Last Unit Is Twin Movable , Hinged Doors Are Provided For The End Bodies , So In This Case Locking Stiffener Is Mounted Onto Drive Unit Cover ; And With Tile Fascia Option , It Will Be Mounted In The Recess Of Vertical Trim . Each Drive Type Units Shall Have Locking Knob Near The Drive Wheel For Manual Locking Of Individual Units When A Person Is Using Those Units . Knob Shall Be Rotated To Unlock Position When Units Are To Be Moved . End Stoppers Shall Be Provided To Prevent Derailment . Door Locking Shall Be Having Hinged Doors Of Recessed Die Cast Handle Cum Lock Giving 3 Way Locking Through A Lever & Shooting Bolts . Guide Channels Shall Have J Section 2 Mm Thick Hr & 25 Mm Square Bright Bar . Easteners Shall Be Galvanized / Blackodized / Zn Plated . The Label Holder Shall Be Made From 2 Mm Thick Clear Transparent Acrylic Sheet . Also Total No . Of Loading Levels Per Understructure Shall Be 24 For Ld4 . Fascia ( Tiling ) 3 Tile Pattern Fascia Option On Drive Side Panel Plus 3 Tile Pattern Fascia On Non-Drive Side Panel Plus 3 Tile Pattern Fascia Option On Back Panel Of Single Last Plus 3 Tile Pattern Fascia Option On Back Panel Of Single Static . The Tiles Are Held Together By Stiffeners & Fasteners In 2 Vertical Metal Trims , Td4 457 Dr - 2361Ht , Overall Dimensions Of Td - 4 Twin Mobile Drive Unit 4 Bay ( U / C , Fittings , Drive , Cover ) Shall Be 3660Mm ( W ) X915mm ( D ) X2361mm ( H ) . The Construction Shall Be Rigid Knock Down Construction Made Out Of 0 . 8Mm Thk For Back & Shelves And 0 . 9 Mm For Sides & Top . Finish Shall Be Epoxy Polyester Powder Coated Thickness Of 45 Microns . The Testing Of Paint Should Be Done For Various Physical & Chemical Properties As Per Is: 101 . Shelf Construction Shall Be Made From Crca Steel 0 . 8 Mm Thick Is :513 . Uniformly Distributed Load Capacity Of 80 Kg . Undercarriage Shall Have Construction In Welded Frame Made Of Hr Sheet 3 . 15 Mm Thick Conforming To Is : 1079 . Finish Shall Be Epoxy Polyester Powder Coat Of Approved Color & Shade With A Dry Film Thickness Of Minimum 45 Microns . The Movements Shall Be Drive Type Configuration : In Case Of D4 Movement Of Units Is Achieved Mechanically Through A Drive Wheel And 2 Stage Sprocket -Chain-Tensioner Arrangement Mounted Rigidly Onto Body Size . For D4 Each Movable Undercarriage Shall Be Provided With 3 Rollers On The Shaft For Driving , 3 Antifriction Ball Bearing For Rolling And 4 Antifriction Ball Bearing For Guiding Between Rail . Fittings Shall Be Centralized Locking Arrangement Through Locking Stiffener Mounted Onto Back Of Single Last Unit So That It Gets Locked On Channels When All The Units Are Brought Together . The Recess Handle Lock Is Of Godrej Make & Placed At Suitable Height . This Arrangement Occupies A Space Of 90 . 0 Mm . When The Last Unit Is Twin Movable , Hinged Doors Are Provided For The End Bodies , So In This Case Locking Stiffener Is Mounted Onto Drive Unit Cover ; And With Tile Fascia Option , It Will Be Mounted In The Recess Of Vertical Trim . Each Drive Type Units Shall Have Locking Knob Near The Drive Wheel For Manual Locking Of Individual Units When A Person Is Using Those Units . Knob Shall Be Rotated To Unlock Position When Units Are To Be Moved . End Stoppers Shall Be Provided To Prevent Derailment . Door Locking Shall Be Having Hinged Doors Of Recessed Die Cast Handle Cum Lock Giving

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 12-05-2021 EMD Exemption Fee 24-05-2021

Key Value

Document Fees
INR 11800 /-
EMD
INR 108700.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail