Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #27776312

Provision Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar Ca No Cwe/Pat/T-10/2021-22 Provn Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar

Issued by Statutory Bodies & Commissions/Committees · DAPPAR, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 May 2021
0 days left
EMD
23400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
DAPPAR → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar Ca No Cwe / Pat / T-10 / 2021-22 Provn Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-May-2021

BOQ

Name of Work: PROVN OF 5 KW SOLAR POWER SYSTEMFOR NSI AND CSD AT MIL STN DAPPER UNDER GE(P) DAPPER)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supply, Installation,Testing and commissioning of 5KW Solar off-grid power plant with 6.25KVA solar power conditioning (PSU), Single phase 230V, Battery bank of 12 V, 150AH, 8 Nos Tubular housing LMLA Solar batteries, including battery rack of suitable size for 8 Nos batteries ,PV modules, 16 Nos, Module mounting structure, Single Phase 230V Invertor 5KW capacity, charge controller device, AC/DC cables, earthing and lightning protection/arrestor etc and consisting of the following main components : -\nPoly Crystaline Solar Photovolaic modules minimum of 325Wp, 16 Nos for 5KW capacity, having efficiency 16.28% min under standard conditions, form fill factor more than 0.74, plant performance ratio > 75% , made of high transmitivity glass front surface and it shall give high encapsulation gain ( transmittance above 90% and bending less than 0.3%). The electrical parameters of SPV modules under standard test condition of irradiance 100 W/sqm2, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under \nMax Peak Power Pmax > 325W Voltage at Max Power :>38.81V \nCurrent at Pmax: >8.12 A\nShort Circuit Current : > 8.84 A\nOpen Circuit Voltage: >45.94\nModule Efficiency: > 16.28% .2Each
21.01(a) Rated outputof the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed. \n(b) It shall perform satisfactority in RH 85% with temperature up to +85 degree C and should withstand wind of 150 kmph on the surface of panel. \n(c) PV modules shall be warrented for their output peak watt capacity, and it shall not fall of its initial value below 90% in first 10 year end and 80% after the end of 25 years. Battery warranty for five years. (d) Each module shall have RFID tag encapsulated with solar cell bearing following details: \nName of manufacture of SPV Module, Name of Manufacturer of solar cell and module) country of Origin ( both cell and module) Peak wattage, Im, Vm and fill factor of the module IV curve of module. \n(e) The temperature coefficient of the module shall not be more than 0.50% degree celcius.
31.02(f) PV modules must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID. \n(g) It shall also be in confirmity to latest minimum technical specification issued by MNRE from time to time. Modules should be of 48 cell configuration and should be of MNRE approved companies/agencies in category/ rating 'SA-1A' . (h) Provision of earting and earth strip/ cable etc for earth of solar Pvmodule/ array etc as per latest IS/MNRE norms to be provided and cost of the same is deemed to be included in the item and no extra amount will be paid to the contractor on this account. (i) Both cell and SPV modules shall be made in India and must conform to DSR norms of MNRE\n (j) Waaree, TATA, ADANI, RENEWSYS
41.03(k)DC Cables & AC Cables: Suitable size of XLPE insulated tinned copper cable of solar grade, 1100 volt and UV resistant for putdoor installations confirming to IEC 60227/15694 & 60502/ is 1554 (Pt& I&II) of minium size 6sq.mm All cables and connectors for use of installation shall be of solar grade which can withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt,burial and attack by moss and microbes for 25 years ans voltage as per latest IEC/IS. All the cables/wires shall be provided with UV resistant printed ferrules for DC side .The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. The AC cables along with AC DB with necessary arrangement to Connect with the existing power supply to be done. The size of XLPE LT cable To be got approved by Engineer in charge. Suitable electronic smart meter To be fixed to measure generation of electricity. Cable batch no,drum no, IS code and size and make shall be metioned on every one meter or as per OEM practice .The wiring of the module interconnection shall be in suitable size UPVC/HDPE pipe. The cost of interconnecting DC copper cable, and earth work for trenches suitable to accommodate solar grade cables from SPV module upto inverters are included in the item. Make: Lapp, Havells, Polycab, Leoni, Siechem
51.04(l) Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanisized iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts,mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fastners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with stadpro report and submitted for the approval of the acepting officer. Cost of all equipments, copper strip up to earth test point and earthing etc are included in this item. The cost of sufficient earthing for lightning protection is included in this included in this item and no extra payment will be made to the contractor on this account.
61.05(m) String Inverter: Procure, fixing, testing and commissioning of 5 KW -1 No 50+3 Hz (min) 1 phase 230 volt, THD< 3%, at nominal power inverter suitable to convert DC power of solar PV module/arry/ to AC for further feeding to bldg confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 5 KW inverter are as under: \nInput (DC) \n DC V oltage Range: 200-240V\n Max DC Voltage: 100V\n Nominal Power : 5 kW\n Max output power : 5 kW\n Nominal AC current : as per standards \n Nominal OUTPUT VOLTAGE: 230V AC\n Output Frequency : 50/60 Hz \n Harmonic Distortion current : < 3%\nEfficiency : 98.3%\nStandby operation consumption (feed in) : < 20 W
72Excavating in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified.60Cum
83Removing excavated material to a distance exc 50m and n exc 250m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.20Cum
94Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified.40Cum
105Supply, laying, jointing, connecting, testing and commissioning UG cable XLPE insulated screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of cross sectional area 35 sqmm 3.5 core all as specified and directed by Engineer in Charge. Note : Excavation and earth work will be measured and paid under respective item of Schedule 'A' Section-II.400RM
116M/L Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified.\nNote :For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as as perpara 19.75 of SSR part-I.20Cum
127M/L Sub Class 'B' old size burnt bricks of class designation 100 for cable protection laid length wise perpendicular tp the axis of cable,adjacent to each othercomplete,all as specified .2.51000 Nos

AI Tender Summary

OUR REF NO 27776312
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 24-05-2021
Authority
Authority Name Military Engineer Services
Work Description Provision Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar Ca No Cwe / Pat / T-10 / 2021-22 Provn Of 5 Kw Solar Power Systeem For Nsi And Csd At Mil Stn Dappar Under Ge Project Dappar
Basic Detail
Tender No 8321/PAT/T-10/2021-22
Bidding Type Tender
Location
City DAPPAR
State Punjab
Key Dates
Publish Date 17 May 2021
Submission Date 24 May 2021
Open Date 26 May 2021
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 23400
Exemption Not Available
Document List
TD.pdf
87A32E01-CACD-4324-ACD4-70BA1761215D.html
Tendernotice_1.pdf
BOQ_489957.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 17, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
May 24, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 24, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 26, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TD.pdf

html

87A32E01-CACD-4324-ACD4-70BA1761215D.html

pdf

Tendernotice_1.pdf

xls

BOQ_489957.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders