Construction Of Toilet Block At Satpuli ( Pauri )
Tender Value
36.60 Lakhs
Estimated cost
Bid Submission
06 May 2021
0 days left
EMD
73000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Satpuli → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Toilet Block At Satpuli ( Pauri )
BOQ
| Name of Work: Construction of Toilet Block, Satpuli, Pauri | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m 2.28.1 | BI01010001010000000000000515BI0100001112 | 64.75 | Sq M |
| 2 | 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 Sq M on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge 2.1.1 | BI01010001010000000000000515BI0100001113 | 85.77 | Sq M |
| 3 | 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq M on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All Kinds of Soil 2.6.1 | BI01010001010000000000000515BI0100001114 | 96.04 | Cu M |
| 4 | 4 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2.26.1 | BI01010001010000000000000515BI0100001115 | 121.77 | Cu M |
| 5 | 5 | Filling available excavated earth (excluding hard rock / Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2.25 | BI01010001010000000000000515BI0100001116 | 29.14 | Cu M |
| 6 | 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 2.27 | BI01010001010000000000000515BI0100001117 | 9.71 | Cu M |
| 7 | 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 4.1.8 | BI01010001010000000000000515BI0100001118 | 11.76 | Cu M |
| 8 | 8 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : - Cement mortar 1:6 (1 cement : 6 coarse sand) 7.1.1 | BI01010001010000000000000515BI0100001119 | 11.94 | Cu M |
| 9 | 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level [ 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) ] 5.1.2 | BI01010001010000000000000515BI0100001120 | 7.92 | Cu M |
| 10 | 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement [ (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)] 5.2.2 | BI01010001010000000000000515BI0100001121 | 8.36 | Cu M |
| 11 | 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 5.3 | BI01010001010000000000000515BI0100001122 | 6.64 | Cu M |
| 12 | 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more 5.22.6 | BI01010001010000000000000515BI0100001123 | 2699 | Kg |
| 13 | 13 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases for columns 4.3.1 | BI01010001010000000000000515BI0100001124 | 71.46 | Sq M |
| 14 | 14 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, piers, abutments, pillars, posts and struts 4.3.3 | BI01010001010000000000000515BI0100001125 | 167.72 | Sq M |
| 15 | 15 | Ruled / Flush pointing on Red sand stone masonry surface with\nlime, surkhi and marble dust mortar in the ratio of 1:1.5:1/2 {One\nlime: 1.5 surkhi (50% red and 50% light yellow surkhi ) : 1/2 marble\ndust}. (The rate is inclusive of all materials & labours involved except scaffolding). 24.5 | BI01010001010000000000000515BI0100001126 | 88 | Sq M |
| 16 | 16 | Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. Coursed rubble masonry (1st sort) 11-6-1-2 MORD | BI01010001010000000000000515BI0100001127 | 39.61 | Cu M |
| 17 | 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 6.4.2 | BI01010001010000000000000515BI0100001128 | 1.02 | Cu M |
| 18 | 18 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to Floor V level [Cement mortar 1:4 (1 cement :4 coarse sand)] 6.13.1 | BI01010001010000000000000515BI0100001129 | 63.1 | Cu M |
| 19 | 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) 13.2.2 | BI01010001010000000000000515BI0100001130 | 169.31 | Sq M |
| 20 | 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 9.1.2 | BI01010001010000000000000515BI0100001131 | 1.25 | Cu m |
| 21 | 21 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood 30 mm thick shutters 9.5.1.2 | BI01010001010000000000000515BI0100001132 | 32.51 | Sq M |
| 22 | 22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 | BI01010001010000000000000515BI0100001133 | 155.52 | Kg |
| 23 | 23 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : - 300x16x5 mm 9.75.1 | BI01010001010000000000000515BI0100001134 | 24 | Each |
| 24 | 24 | Providing and fixing bright finished brass handles with screws etc. complete: - 125 mm 9.81.1 | BI01010001010000000000000515BI0100001135 | 24 | Each |
| 25 | 25 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. - Twin rubber stopper 9.101.2 | BI01010001010000000000000515BI0100001136 | 12 | Each |
| 26 | 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 11.41.2\n | BI01010001010000000000000515BI0100001137 | 64.75 | Sq M |
| 27 | 27 | Providing and laying Ceramic glazed Wall tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. 11.40\n | BI01010001010000000000000515BI0100001138 | 86.8 | Sq M |
| 28 | 28 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominal size graded stone aggregate.) 4.17 | BI01010001010000000000000515BI0100001139 | 33.18 | Sq M |
| 29 | 29 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric Resistance or Induction Butt Welded Tubes 10.16.3 | BI01010001010000000000000515BI0100001140 | 741.66 | Kg |
| 30 | 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, Like birla white /JK white or equivalent, over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. 13.80 | BI01010001010000000000000515BI0100001141 | 169.31 | Sq M |
| 31 | 31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :- New work (two or more coats) over and including water thinnable priming coat with cement primer 13.41.1 | BI01010001010000000000000515BI0100001142 | 169.31 | Sq M |
| 32 | 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 13.61.1 | BI01010001010000000000000515BI0100001143 | 8.64 | Sq M |
| 33 | 33 | 12.45.1Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square SUB HEAD : 12- ROOFING 742 edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : - 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I | BI01010001010000000000000515BI0100001144 | 64.75 | Sq M |
| 34 | 34 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² 12.1.1 | BI01010001010000000000000515BI0100001145 | 109.34 | Sq M |
| 35 | 35 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B 1.10.2 | BI01010001010000000000000515BI0100001146 | 76 | Each |
| 36 | 36 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 1.31 | BI01010001010000000000000515BI0100001147 | 5 | Each |
| 37 | 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 1.14.1 | BI01010001010000000000000515BI0100001148 | 310 | rmt |
| 38 | 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1.14.2 | BI01010001010000000000000515BI0100001149 | 291 | rmt |
| 39 | 39 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 1.14.8 | BI01010001010000000000000515BI0100001150 | 270 | rmt |
| 40 | 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 1.14.9 | BI01010001010000000000000515BI0100001151 | 113 | rmt |
| 41 | 41 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc. as required. 1.33 | BI01010001010000000000000515BI0100001152 | 7 | Each |
| 42 | 42 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 em) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1.45 | BI01010001010000000000000515BI0100001153 | 6 | each |
| 43 | 43 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. 1.25 | BI01010001010000000000000515BI0100001154 | 8 | Each |
| 44 | 44 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 | BI01010001010000000000000515BI0100001155 | 7 | each |
| 45 | 45 | 4 way (4+12), TPN, MCB DB, double door, horizontal type 1754 | BI01010001010000000000000515BI0100001156 | 6 | Each |
| 46 | 46 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 2.10.1 | BI01010001010000000000000515BI0100001157 | 11 | Each |
| 47 | 47 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 2.11 | BI01010001010000000000000515BI0100001158 | 5 | Each |
| 48 | 48 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 n1A in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 2.15.3 | BI01010001010000000000000515BI0100001159 | 5 | Each |
| 49 | 49 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry 'enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 5.4 | BI01010001010000000000000515BI0100001160 | 9 | Each |
| 50 | 50 | Supplying and laying 25 mm X 5 mm G.l strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) 5.9 | BI01010001010000000000000515BI0100001161 | 9 | R M |
| 51 | 51 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 18.48 | BI01010001010000000000000515BI0100001162 | 4000 | Litre |
| 52 | 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia .Pipes. 18.8.3 | BI01010001010000000000000515BI0100001163 | 60 | R M |
| 53 | 53 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. External work 50 mm nominal outer dia .Pipes. 18.9.6 | BI01010001010000000000000515BI0100001164 | 14 | R M |
| 54 | 54 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. External work 75 mm diaMeter (minimum wall thickness 3.2mm) 18.9.8 | BI01010001010000000000000515BI0100001165 | 16 | R M |
| 55 | 55 | Providing and fixing unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes for working pressure of 4 kg/sqcm. External work 100 mm diaMeter (minimum wall thickness 3.2mm) 18.9.9 | BI01010001010000000000000515BI0100001166 | 24 | R M |
| 56 | 56 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 75 mm 7192 | BI01010001010000000000000515BI0100001167 | 24 | Each |
| 57 | 57 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm 7193 | BI01010001010000000000000515BI0100001168 | 24 | Each |
| 58 | 58 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single pushfit Coupler 75 mm 7194 | BI01010001010000000000000515BI0100001169 | 12 | Each |
| 59 | 59 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single pushfit Coupler 110 mm 7195 | BI01010001010000000000000515BI0100001170 | 12 | Each |
| 60 | 60 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm 7196 | BI01010001010000000000000515BI0100001171 | 24 | Each |
| 61 | 61 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm 7197 | BI01010001010000000000000515BI0100001172 | 24 | Each |
| 62 | 62 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 75x75x75 mm 7198 | BI01010001010000000000000515BI0100001173 | 24 | Each |
| 63 | 63 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm 7199 | BI01010001010000000000000515BI0100001174 | 24 | Each |
| 64 | 64 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.50 75 mm bend 7208 | BI01010001010000000000000515BI0100001175 | 24 | Each |
| 65 | 65 | Providing and fixing unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC soil and waste pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.50 110 mm bend 7209 | BI01010001010000000000000515BI0100001176 | 24 | Each |
| 66 | 66 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 17.78 | BI01010001010000000000000515BI0100001177 | 8 | Each |
| 67 | 67 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : -- One urinal basin with 5 litre white P.V.C. automatic flushing cistern 17.4.1 | BI01010001010000000000000515BI0100001178 | 5 | Each |
| 68 | 68 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 17.7.1 | BI01010001010000000000000515BI0100001179 | 10 | Each |
| 69 | 69 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 17.22A | BI01010001010000000000000515BI0100001180 | 8 | Each |
| 70 | 70 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 17.31 | BI01010001010000000000000515BI0100001181 | 8 | Each |
| 71 | 71 | Providing and fixing toilet paper holder : C.P. brass 17.34.1 | BI01010001010000000000000515BI0100001182 | 8 | Each |
| 72 | 72 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore. 18.49.1 | BI01010001010000000000000515BI0100001183 | 15 | Each |
| 73 | 73 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore. 18.52.1 | BI01010001010000000000000515BI0100001184 | 10 | Each |
| 74 | 74 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore. 18.53.1 | BI01010001010000000000000515BI0100001185 | 4 | Each |
| 75 | 75 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm diaMeter PVC. Pipe 19.2.1 | BI01010001010000000000000515BI0100001186 | 36 | RM |
| 76 | 76 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 200 mm diaMeter OD 19.2.3 | BI01010001010000000000000515BI0100001187 | 60 | RM |
| 77 | 77 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes ,110 mm diaMeter (minimum wall thickness 2.2mm) 12.41.2 | BI01010001010000000000000515BI0100001188 | 90 | RM |
| 78 | 78 | Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type (With well burnt bricks ) 19.4.3.1 | BI01010001010000000000000515BI0100001189 | 15 | Each |
| 79 | 79 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diaMeter, 160 mm bottom diaMeter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay bricks of 25 kg /sqcm compressive strength. 18.33.1 | BI01010001010000000000000515BI0100001190 | 8 | Each |
AI Tender Summary
Tender Timeline
Apr 27, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedMay 06, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 06, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender