| Name of Work: Electrical work for proposed International Cruise Terminal at Mumbai Port Trust. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Supply, Delivery, Installation, Testing and Commissioning of the undermentioned items all in accordance with detailed technical specifications, drawing, etc. (Design & preparation of electrical system / layout and submission of \"Good for Construction\" drawing shall be in the scope of contractor. No separate charges shall be paid.) | |||
| 2 | 2 | PANELS & D.B.S | |||
| 3 | 3 | Providing Panel / Power distribution Boards suitable for 415V, 50Hz ,3ph 4 wire,Totally type tested as per IEC 61439-1&2, & Internal arc tested for 85kA for 0.4 Sec as per IEC 61641- V2, Seismic zone 5 compliance as per IEC 60068-3-3, IP 54,Form 4b ( Main Panels) Construction, supply dust and vermin proof floor/ wall mounting cubicle pattern with removable gland plates, copper bus bar, mounting frame, grouting made out of crca sheet, double door(for oudoor), duly powder coated painted as specified as follows. MCB with ‘c’ curve for lighting & power, d curve will be used for PC. | |||
| 4 | 4 | RETAIL Floor Panel For GF/FF\nComprising of: 400Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming – 400Amp TPN MCCB, 50kA, Microprocessor Over current, Short circuit and 3Ph 4 Wire Earth fault - 1No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no, Copper Bus Bar 400 Amp. TPN , 50kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Supressor -1 No.\nOutgoing – 200 Amp 4P MCCB, 36kA with Microprocessor Over current, Short circuit -1No, 160 Amp. TPN MCCB, 36kA -2 Nos, 125 Amp. TPN MCCB, 36kA -2 Nos, All outgoing will be having Load manager with RS 485 port- 1 No, As per SLD provided. | |||
| 5 | 4.1 | Material | 2 | Nos. | |
| 6 | 4.2 | Installation | 2 | Nos. | |
| 7 | 5 | Retail Panel-1 For GF/FF/SF\nIncoming –125 Amp. TPN MCCB, 25kA, with T/M release- 1 No. Three Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOutgoing – 63Amp TPN MCB- 6 Nos, all outgoing will be having Energy meter with RS 485 port, Copper Bus Bar 125 Amp. TPN, 25kA for 1 sec. - 1 Set, as per SLD provided.\n | |||
| 8 | 5.1 | Material | 2 | Nos. | |
| 9 | 5.2 | Installation | 2 | Nos. | |
| 10 | 6 | Retail Panel-2 For GF/FF\nIncoming –125 Amp. TPN MCCB, 25kA, with T/M release- 1 No., Three Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOutgoing –\n20Amp TPN MCB- 12 Nos, all outgoing will be having Energy meter with RS 485 port, Copper Bus Bar 125 Amp. TPN, 25kA for 1 sec. - 1 Set, as per SLD provided.\n | |||
| 11 | 6.1 | Material | 2 | Nos. | |
| 12 | 6.2 | Installation | 2 | Nos. | |
| 13 | 7 | Cruise Common Area Floor Panel For GF/FF\nComprising of: 630Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming –\n630Amp TPN MCCB, 50 kA, Microprocessor Over current, Short circuit and 3Ph 4 Wire Earth fault - 1No., Three Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no., Copper Bus Bars of 630 Amp TPN 50kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Supressor -1 No.\nOutgoing –\n250 Amp 4P MCCB, 36kA with Microprocessor Over current, Short circuit - 5 Nos., 160 Amp. TPN MCCB, 36kA -2 Nos., all outgoing will be having Load manager with RS 485 port- 1 No\nAs per SLD provided.\n | |||
| 14 | 7.1 | Material | 4 | Nos. | |
| 15 | 7.2 | Installation | 4 | Nos. | |
| 16 | 8 | Cruise Area MLDB GF/FF\nIncoming –250 Amp. TPN MCCB, 25kA, with T/M release- 1 No., Three Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOut going –\n63Amp TPN MCB- 15 Nos, Copper Bus Bar 250 Amp. TPN , 25kA for 1 sec. - 1 Set.\nAs per SLD provided.\n | |||
| 17 | 8.1 | Material | 4 | Nos. | |
| 18 | 8.2 | Installation | 4 | Nos. | |
| 19 | 9 | Cruise Area MPDB GF/FF\nIncoming –250 Amp. TPN MCCB, 25kA, with T/M release- 1 No.\nThree Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOutgoing – 63Amp TPN MCB- 15 Nos, Copper Bus Bar 250 Amp. TPN , 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 20 | 9.1 | Material | 4 | Nos. | |
| 21 | 9.2 | Installation | 4 | Nos. | |
| 22 | 10 | Cruise Area MACDB GF/FF\nIncoming – 250 Amp. TPN MCCB *, 25kA, with T/M release- 1 No., Three Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOutgoing – 63Amp TPN MCB- 15 Nos, Copper Bus Bar 250 Amp. TPN , 25kA for 1 sec. - 1 Set.\n*This MCCBs is to be provided with Shunt trip arrangement for operation in case of fire alarm with 230/24 V Transformer and 24 V Pla relay. As per SLD provided.\n | |||
| 23 | 10.1 | Material | 4 | Nos. | |
| 24 | 10.2 | Installation | 4 | Nos. | |
| 25 | 11 | Cruise Area Retail Panel \nComprising of: Incoming – 160 Amp. TPN MCCB, 25kA, with T/M release- 1 No., Three Nos. Phase Indicating Lamps, Load Manager with RS 485 port – 1 no.\nOutgoing – 20Amp DP MCB- 24 Nos, All outgoing will be having Energy meter with RS 485 port, Copper Bus Bar 160 Amp. TPN, 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 26 | 11.1 | Material | 1 | Nos. | |
| 27 | 11.2 | Installation | 1 | Nos. | |
| 28 | 12 | External LTG Panel\nComprising of: 160Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming –160 Amp. TPN MCCB, 25kA, with T/M release- 1 No.\nLoad Manager with RS 485 port – 1 no., 40kA Class (B+C) Surge Supressor -1 No.\nOut going – 63A TPN MCB - 28 Nos., Copper Bus Bar 160 Amp. TPN , 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 29 | 12.1 | Material | 1 | Nos. | |
| 30 | 12.2 | Installation | 1 | Nos. | |
| 31 | 13 | Fire Fighting Panel\nComprising of:\n400Amp 4P Microprocessor Based open transition type Auto, changeover Switch (ASCO 230 Series) - 1 No., Three Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set\nAmmeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no., Copper Bus Bars of 400 Amp TPN 50kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Suppressor -1 No.\nIncoming –\n400 Amp. TPN MCCB, 50kA, with T/M release- 1 No., Load Manager with RS 485 port – 1 no.\nOutgoing –200 TPN MCCB, 36kA - 6 Nos., 63 TPN MCCB, 36kA - 6 Nos. As per SLD provided.\n | |||
| 32 | 13.1 | Material | 1 | Nos. | |
| 33 | 13.2 | Installation | 1 | Nos. | |
| 34 | 14 | Plumbing Panel\nComprising of: 250Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming –\n250 Amp. TPN MCCB, 36kA, with T/M release- 1 No., Three Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no., Copper Bus Bars of 400 Amp TPN 50kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Suppressor -1 No.\nOutgoing –\n100 TPN MCCB, 25 kA - 4 Nos., 63 TPN MCCB, 25kA - 6 Nos., 40 TPN MCCB, 25kA - 6 Nos., Copper Bus Bar 250 Amp. TPN , 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 35 | 14.1 | Material | 1 | Nos. | |
| 36 | 14.2 | Installation | 1 | Nos. | |
| 37 | 15 | Lift & Escalator Panel (North / South)\nComprising of: 400Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.,\nIncoming –400 Amp. TPN MCCB, 36kA, with T/M release- 1 No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no., Copper Bus Bars of 400 Amp TPN 36kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Supressor -1 No.\nOutgoing –63 TPN MCCB, 25kA - 20 Nos, As per SLD provided\n | |||
| 38 | 15.1 | Material | 2 | Nos. | |
| 39 | 15.2 | Installation | 2 | Nos. | |
| 40 | 16 | Emergency Lighting Panel\nComprising of: Incoming – 160 Amp. 4P MCCB, 25kA, with T/M release- 1 No., Load Manager with RS 485 port – 1 no. , Three Nos. Phase Indicating Lamps, 20kA Class (C) Surge suppressor -1 No.\nOutgoing – 63 4P MCB - 28 Nos., Copper Bus Bar 160 Amp. 4P , 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 41 | 16.1 | Material | 1 | Nos. | |
| 42 | 16.2 | Installation | 1 | Nos. | |
| 43 | 17 | UPS OUTPUT Panel\nComprising of: Incoming –160 Amp. 4P MCCB, 25kA, with T/M release- 1 No., Load Manager with RS 485 port – 1 no., Three Nos. Phase Indicating Lamps, 20kA Class (C) Surge suppressor -1 No.\nOutgoing – 63 4P MCB - 28 Nos., Copper Bus Bar 160 Amp. 4P, 25kA for 1 sec. - 1 Set. As per SLD provided.\n | |||
| 44 | 17.1 | Material | 1 | Nos. | |
| 45 | 17.2 | Installation | 1 | Nos. | |
| 46 | 18 | Primary/Secondary Pump Panel\nComprising of: 250Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming – 250 Amp. TPN MCCB, 36kA, with T/M release- 1 No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, Energy Meter with RS 485 port – 1 no., Copper Bus Bars of 250 Amp TPN 36kA for 1 sec. - 1 Set., 40kA Class (B+C) Surge suppressor -1 No.\nOutgoing – 125 TPN MCCB, 25kA - 10 Nos. As per SLD provided.\n | |||
| 47 | 18.1 | Material | 2 | Nos. | |
| 48 | 18.2 | Installation | 2 | Nos. | |
| 49 | 19 | Fan PCC - 1 & 2\nComprising of: Providing Below Mentioned Configuration in IP 66 enclosure Panel, for free standing outdoor application, complete with MS Frameworks Legs, 400Amp 4P Microprocessor Based open transition type Auto Changeover Switch (ASCO 230 Series) - 1 No.\nIncoming – 400 Amp. TPN MCCB, 36kA, with T/M release- 1 No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set\nEnergy Meter with RS 485 port – 1 no., Copper Bus Bars of 400 Amp TPN 36kA for 1 sec. - 1 Set., 40kA Class (B+C) Surge suppressor -1 No.\nOutgoing – 63 TPN MCCB, 25kA - 25 Nos. As per SLD provided.\n | |||
| 50 | 19.1 | Material | 2 | Nos. | |
| 51 | 19.2 | Installation | 2 | Nos. | |
| 52 | 20 | Ventibule Panel-1&2\nComprising of: 630Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) - 1 No.\nIncoming – 630 Amp. TPN MCCB, 50kA, with T/M release- 1 No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set\nEnergy Meter with RS 485 port – 1 no., Copper Bus Bars of 630 Amp TPN 50kA for 1 sec. - 1 Set., 40kA Class (B+C) Surge suppressor -1 No.\nOutgoing – 250 TPN MCCB, 36kA - 1 No., 250 TPN MCCB*, 36kA - 1 No., 100 TPN MCCB, 36kA - 1 No.\nLDB Section\nIncoming – 63A TPN 36kA MCCB with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n100 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 63 Amp TPN MCB - 6 Nos.\nPDB Section\nIncoming – 63A TPN 36kA MCCB with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n100 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 63 Amp TPN MCB - 6 Nos.\nACDB Section\nIncoming – 100A TPN 36kA MCCB* with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n200 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 40 Amp TPN MCCB - 4 Nos., 32 Amp TPN MCB - 5 Nos.\nLift Section\nIncoming – 250A TPN 36kA MCCB with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n250 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 63 Amp TPN MCB - 10 Nos. As per SLD provided.\nProviding On/Off/ Trip status contact of incoming breakers for BMS\n* This MCCBs is to be provided with Shunt trip arrangement for operation in case of fire alarm with 230/24 V Transformer and 24 V Pla relay. \n | |||
| 53 | 20.1 | Material | 2 | Nos. | |
| 54 | 20.2 | Installation | 2 | Nos. | |
| 55 | 21 | Outdoor Type ODU Panel for Vestibule 1 & 2\nProviding Below Mentioned Configuration in IP 66 enclosure Panel, for free standing outdoor application, complete with MS Frameworks Legs \nIncoming – 250A TPN 36kA MCCB with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n250 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 63 Amp TPN MCB - 13 Nos. As per SLD provided.\nProviding On/Off/ Trip status contact of incoming breakers for BMS\n* This MCCBs is to be provided with Shunt trip arrangement for operation in case of fire alarm with 230/24 V Transformer and 24 V Pla relay. \n | |||
| 56 | 21.1 | Material | 2 | Nos. | |
| 57 | 21.2 | Installation | 2 | Nos. | |
| 58 | 22 | Outdoor Tyep Smoke Exactor panel for Retail & Cruise\nProviding Below Mentioned Configuration in IP 66 enclosure Panel, for free standing outdoor application, complete with MS Frameworks Legs, 630Amp 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) – 1 No.\nIncoming –630A TPN 36kA MCCB with O/C,S/C & E/F module - 1 No., Three Nos. Phase Indicating Lamps, Control fuses– 1 set. \n630 Amps TPN Cu. Busbar 36kA for 1 sec. - 1 Set.\nOutgoing – 63 Amp TPN MCB - 26 Nos. As per SLD provided.\nProviding On/Off/ Trip status contact of incoming breakers for BMS\n* This MCCBs is to be provided with Shunt trip arrangement for operation in case of fire alarm with 230/24 V Transformer and 24 V Pla relay. \n | |||
| 59 | 22.1 | Material | 2 | Nos. | |
| 60 | 22.2 | Installation | 2 | Nos. | |
| 61 | 23 | Lighting Distribution Board\nComprising of : Incoming of 63 A TPN MCB - 1 No.\nPhase indicating lamps\nOutgoing – 40 Amp, DP 30 mA RCCB – 3 Nos., 10 A SP MCB -12 Nos. per phase Total-36 Nos., 100 A TPN CU Bus Bars - 1 Set.\n | |||
| 62 | 23.1 | Material | 26 | Nos. | |
| 63 | 23.2 | Installation | 26 | Nos. | |
| 64 | 24 | Power Distribution Board \nComprising of: Incoming of 63 A TPN MCB - 1 No.\nPhase indicating lamps\nOutgoing – 40 Amp DP 100mA RCCB -3 Nos., 20 A SP MCB – 12, Nos. per phase Total –36 Nos., 100 A TPN CU Bus Bars - 1 Set.\n | |||
| 65 | 24.1 | Material | 30 | Nos. | |
| 66 | 24.2 | Installation | 30 | Nos. | |
| 67 | 25 | A C Distribution Board (for Indoor Units & VAV)\nComprising of: Incoming of 63A TPN 300mA RCBO - 1 No.\nPhase indicating lamps\nOutgoing – 20 A SP MCB – 12 Nos. per phase Total – 36 Nos.\n100 A TPN CU Bus Bars - 1 Set.\n | |||
| 68 | 25.1 | Material | 15 | Nos. | |
| 69 | 25.2 | Installation | 15 | Nos. | |
| 70 | 26 | UPS Distribution Boards\nComprising of: Incoming of 63 Amp 4P MCB - 1 No.\nPhase indicating lamps\nOutgoing –\n32 Amp DP 300 ma Si RCCB -3 Nos., 16 A SP MCB – 8 Nos. per phase Total – 24 Nos., 100 A TPN CU Bus Bars - 1 Set.\n | |||
| 71 | 26.1 | Material | 20 | Nos. | |
| 72 | 26.2 | Installation | 20 | Nos. | |
| 73 | 27 | BMS Distribution Boards\nComprising of: Incoming of 63 Amp 4P MCB - 1 No.\nPhase indicating lamps\nOutgoing – 16 A SP MCB – 12 Nos. per phase Total – 36 Nos.\n100 A TPN CU Bus Bars - 1 Set.\n | |||
| 74 | 27.1 | Material | 1 | Nos. | |
| 75 | 27.2 | Installation | 1 | Nos. | |
| 76 | 28 | Emergency Distribution Board\nComprising of: Incoming of 63 A 4P MCB - 1 No., Phase indicating lamps\nOutgoing – 40 Amp, DP 30 mA RCCB – 3 Nos., 10 A SP MCB -8 Nos. per phase Total-24 Nos., 100 A TPN CU Bus Bars - 1 Set.\n | |||
| 77 | 28.1 | Material | 26 | Nos. | |
| 78 | 28.2 | Installation | 26 | Nos. | |
| 79 | 29 | External Lighting Board\nProviding Below Mentioned Configuration DB in IP 66 enclosure, for free standing outdoor application, complete with MS Frameworks Legs \nComprising of: Incoming of 63 A TPN MCCB - 1 No. T/M release O/C,S/C & E/F, Photoelectric programmable lux sensor IP 65,\nAstronomical Timer as override for above sensor, Phase indicating, lamps- 1 set\nOutgoing – 40 Amp, TPN 300 mA RCCB – 1 No., 32 A TPN MCB – 10 Nos., 20 TPN MCB – 14 Nos., 100 A TPN CU Bus Bars - 1 Set.\n | |||
| 80 | 29.1 | Material | 4 | Nos. | |
| 81 | 29.2 | Installation | 4 | Nos. | |
| 82 | 30 | Providing in weatherproof IP65 enclosure 1000 Amp, 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) & 1000A TPN Microprocessor Over current, Short circuit and Earth fault. | |||
| 83 | 30.1 | Material | 5 | Nos. | |
| 84 | 30.2 | Installation | 5 | Nos. | |
| 85 | 31 | Providing in sheet steel enclosure 160 Amp, 4P Microprocessor Based open transition type Auto changeover Switch (ASCO 230 Series) & 160A 4P Microprocessor Over current & Short circuit. | |||
| 86 | 31.1 | Material | 2 | Nos. | |
| 87 | 31.2 | Installation | 2 | Nos. | |
| 88 | 32 | Providing in weatherproof IP66 enclosure 63Amp TPN MCB including mounting, fabrication, cable box etc. | |||
| 89 | 32.1 | Material | 25 | Nos. | |
| 90 | 32.2 | Installation | 25 | Nos. | |
| 91 | 33 | Providing in weatherproof IP66 enclosure 32Amp TPN MCB including mounting, fabrication, cable box etc. | |||
| 92 | 33.1 | Material | 15 | Nos. | |
| 93 | 33.2 | Installation | 15 | Nos. | |
| 94 | 34 | Providing in sheet steel enclosure 200 Amp TPN MCCB with T/M release, 36 KA, including mounting, fabrication, cable box etc. | |||
| 95 | 34.1 | Material | 8 | Nos. | |
| 96 | 34.2 | Installation | 8 | Nos. | |
| 97 | 35 | Providing in sheet steel enclosure 160 Amp TPN MCCB with T/M release, 36 KA, including mounting, fabrication, cable box etc. | |||
| 98 | 35.1 | Material | 5 | Nos. | |
| 99 | 35.2 | Installation | 5 | Nos. | |
| 100 | 36 | Providing in sheet steel enclosure 125 Amp TPN MCCB with T/M release, 36 KA, including mounting, fabrication, cable box etc. | |||
| 101 | 36.1 | Material | 2 | Nos. | |
| 102 | 36.2 | Installation | 2 | Nos. | |
| 103 | 37 | Providing in sheet steel enclosure 100 Amp TPN MCCB with T/M release, 36 KA, including mounting, fabrication, cable box etc. | |||
| 104 | 37.1 | Material | 5 | Nos. | |
| 105 | 37.2 | Installation | 5 | Nos. | |
| 106 | 38 | Providing in weatherproof IP66 enclosure 125 Amp TPN MCCB with T/M release, 36 KA, including mounting, fabrication, cable box etc. | |||
| 107 | 38.1 | Material | 15 | Nos. | |
| 108 | 38.2 | Installation | 15 | Nos. | |
| 109 | 39 | Providing in sheet steel enclosure 63 Amp TPN MCB, including mounting, fabrication, cable box etc. | |||
| 110 | 39.1 | Material | 35 | Nos. | |
| 111 | 39.2 | Installation | 35 | Nos. | |
| 112 | 40 | Providing in sheet steel enclosure 32 Amp TPN MCB, including mounting, fabrication, cable box etc. | |||
| 113 | 40.1 | Material | 75 | Nos. | |
| 114 | 40.2 | Installation | 75 | Nos. | |
| 115 | 41 | Providing in sheet steel enclosure 40 Amp DP MCB, including mounting, fabrication, cable box etc. | |||
| 116 | 41.1 | Material | 10 | Nos. | |
| 117 | 41.2 | Installation | 10 | Nos. | |
| 118 | 42 | Providing in sheet steel enclosure 63 Amp DP MCB, including mounting, fabrication, cable box etc. | |||
| 119 | 42.1 | Material | 15 | Nos. | |
| 120 | 42.2 | Installation | 15 | Nos. | |
| 121 | 43 | Providing in sheet steel enclosure 32 Amp DP MCB, including mounting, fabrication, cable box etc. | |||
| 122 | 43.1 | Material | 50 | Nos. | |
| 123 | 43.2 | Installation | 50 | Nos. | |
| 124 | 44 | Cables: Providing 1.1KV stranded copper / aluminum conductor 3½ core XLPE insulated conductor and insulation , flat steel wires armoring, tough heat resisting outer sheets of following sizes. | |||
| 125 | 45 | 3½ C x 300 Sq. mm.Al Conductor XLPE | |||
| 126 | 45.1 | Material | 3000 | Mtrs | |
| 127 | 45.2 | Installation | 3000 | Mtrs | |
| 128 | 46 | 3½ C x 240 Sq. mm.Al Conductor XLPE | |||
| 129 | 46.1 | Material | 4500 | Mtrs | |
| 130 | 46.2 | Installation | 4500 | Mtrs | |
| 131 | 47 | 3½ C x 185 Sq. mm.Al Conductor XLPE | |||
| 132 | 47.1 | Material | 3500 | Mtrs | |
| 133 | 47.2 | Installation | 3500 | Mtrs | |
| 134 | 48 | 3½ C x 150 Sq. mm.Al Conductor XLPE | |||
| 135 | 48.1 | Material | 2000 | Mtrs | |
| 136 | 48.2 | Installation | 2000 | Mtrs | |
| 137 | 49 | 3½ C x 120 Sq. mm.Al Conductor XLPE | |||
| 138 | 49.1 | Material | 850 | Mtrs | |
| 139 | 49.2 | Installation | 850 | Mtrs | |
| 140 | 50 | 3½ C x 95 Sq. mm.Al Conductor XLPE | |||
| 141 | 50.1 | Material | 400 | Mtrs | |
| 142 | 50.2 | Installation | 400 | Mtrs | |
| 143 | 51 | 3½ C x 70 Sq. mm.Al Conductor XLPE | |||
| 144 | 51.1 | Material | 800 | Mtrs | |
| 145 | 51.2 | Installation | 800 | Mtrs | |
| 146 | 52 | 3½ C x 50 Sq. mm.Al Conductor XLPE | |||
| 147 | 52.1 | Material | 100 | Mtrs | |
| 148 | 52.2 | Installation | 100 | Mtrs | |
| 149 | 53 | 3½ C x 35 Sq. mm.Al Conductor XLPE | |||
| 150 | 53.1 | Material | 450 | Mtrs | |
| 151 | 53.2 | Installation | 450 | Mtrs | |
| 152 | 54 | 4 C x 25 Sq. mm.Al Conductor XLPE | |||
| 153 | 54.1 | Material | 17500 | Mtrs | |
| 154 | 54.2 | Installation | 17500 | Mtrs | |
| 155 | 55 | Providing of 1.1 KV Grade PVC insulated, PVC sheathed GI wire armored multicore copper Stranded conductor, Cable of following sizes to be laid in prepared trenches/ excavated trenches/ on wall / on trays complete with dressing saddling clamping etc. Including civil work and required accessories spacers, clamps and hardware etc. | |||
| 156 | 56 | 4C x 10 Sq mm YWY | |||
| 157 | 56.1 | Material | 2000 | Mtrs | |
| 158 | 56.2 | Installation | 2000 | Mtrs | |
| 159 | 57 | 4 C x 6 Sq. mm. YRY | |||
| 160 | 57.1 | Material | 1000 | Mtrs | |
| 161 | 57.2 | Installation | 1000 | Mtrs | |
| 162 | 58 | 4 C x 4 Sq. mm. YRY | |||
| 163 | 58.1 | Material | 500 | Mtrs | |
| 164 | 58.2 | Installation | 500 | Mtrs | |
| 165 | 59 | 3 C x 6 Sq. mm. YRY | |||
| 166 | 59.1 | Material | 575 | Mtrs | |
| 167 | 59.2 | Installation | 575 | Mtrs | |
| 168 | 60 | 3 C x 4 Sq. mm. YRY | |||
| 169 | 60.1 | Material | 400 | Mtrs | |
| 170 | 60.2 | Installation | 400 | Mtrs | |
| 171 | 61 | 3 C x 2.5 Sq. mm. YWY | |||
| 172 | 61.1 | Material | 750 | Mtrs | |
| 173 | 61.2 | Installation | 750 | Mtrs | |
| 174 | 62 | 4 C x 16 Sq. mm. YWY | |||
| 175 | 62.1 | Material | 2500 | Mtrs | |
| 176 | 62.2 | Installation | 2500 | Mtrs | |
| 177 | 63 | 3 C x 2.5 Sq. mm. YY | |||
| 178 | 63.1 | Material | 750 | Mtrs | |
| 179 | 63.2 | Installation | 750 | Mtrs | |
| 180 | 64 | Providing Termination of cables with Double compression Brass cable gland and with crimping type copper/AL lugs suitable for copper/AL conductor cable with consumable such as tape, hard ware. | |||
| 181 | 65 | 3½ C x 300 Sq. mm.Al Conductor XLPE | |||
| 182 | 65.1 | Material | 320 | Nos | |
| 183 | 65.2 | Installation | 320 | Nos | |
| 184 | 66 | 3½ C x 240 Sq. mm.Al Conductor XLPE | |||
| 185 | 66.1 | Material | 130 | Nos | |
| 186 | 66.2 | Installation | 130 | Nos | |
| 187 | 67 | 3½ C x 185 Sq. mm.Al Conductor XLPE | |||
| 188 | 67.1 | Material | 100 | Nos | |
| 189 | 67.2 | Installation | 100 | Nos | |
| 190 | 68 | 3½ C x 150 Sq. mm.Al Conductor XLPE | |||
| 191 | 68.1 | Material | 24 | Nos | |
| 192 | 68.2 | Installation | 24 | Nos | |
| 193 | 69 | 3½ C x 120 Sq. mm.Al Conductor XLPE | |||
| 194 | 69.1 | Material | 80 | Nos | |
| 195 | 69.2 | Installation | 80 | Nos | |
| 196 | 70 | 3½ C x 95 Sq. mm.Al Conductor XLPE | |||
| 197 | 70.1 | Material | 40 | Nos | |
| 198 | 70.2 | Installation | 40 | Nos | |
| 199 | 71 | 3½ C x 70 Sq. mm.Al Conductor XLPE | |||
| 200 | 71.1 | Material | 44 | Nos | |
| 201 | 71.2 | Installation | 44 | Nos | |
| 202 | 72 | 3½ C x 50 Sq. mm.Al Conductor XLPE | |||
| 203 | 72.1 | Material | 6 | Nos | |
| 204 | 72.2 | Installation | 6 | Nos | |
| 205 | 73 | 3½ C x 35 Sq. mm.Al Conductor XLPE | |||
| 206 | 73.1 | Material | 20 | Nos | |
| 207 | 73.2 | Installation | 20 | Nos | |
| 208 | 74 | 4 C x 25 Sq. mm.Al Conductor XLPE | |||
| 209 | 74.1 | Material | 600 | Nos | |
| 210 | 74.2 | Installation | 600 | Nos | |
| 211 | 75 | Providig Termination of cables with Double compression Brass cable gland and with crimping type copper/AL lugs suitable for copper/AL conductor cable with consumable such as tape, hard ware. | |||
| 212 | 76 | 4Cx 10Sq mm YWY | |||
| 213 | 76.1 | Material | 80 | Nos | |
| 214 | 76.2 | Installation | 80 | Nos | |
| 215 | 77 | 4 C x 6 Sq. mm. YRY | |||
| 216 | 77.1 | Material | 50 | Nos | |
| 217 | 77.2 | Installation | 50 | Nos | |
| 218 | 78 | 4 C x 4 Sq. mm. YRY | |||
| 219 | 78.1 | Material | 100 | Nos | |
| 220 | 78.2 | Installation | 100 | Nos | |
| 221 | 79 | 3 C x 6 Sq. mm. YRY | |||
| 222 | 79.1 | Material | 50 | Nos | |
| 223 | 79.2 | Installation | 50 | Nos | |
| 224 | 80 | 3 C x 4 Sq. mm. YRY | |||
| 225 | 80.1 | Material | 50 | Nos | |
| 226 | 80.2 | Installation | 50 | Nos | |
| 227 | 81 | 3 C x 2.5 Sq. mm. YWY | |||
| 228 | 81.1 | Material | 26 | Nos | |
| 229 | 81.2 | Installation | 26 | Nos | |
| 230 | 82 | 4 C x 16 Sq. mm. YWY | |||
| 231 | 82.1 | Material | 100 | Nos | |
| 232 | 82.2 | Installation | 100 | Nos | |
| 233 | 83 | 3 C x 2.5 Sq. mm. YY | |||
| 234 | 83.1 | Material | 90 | Nos | |
| 235 | 83.2 | Installation | 90 | Nos | |
| 236 | 84 | Supply, Installation and testing of 1100 V Grade PVC insulated, PVC sheathed unarmored single core copper Stranded conductor, Cable of 300 Sq. mm. size through Flexible GI conduit in approved manner on wall / on trays complete with dressing saddling clamping termination etc. Including civil work and required accessories spacers, clamps and hardware etc. | |||
| 237 | 84.1 | Material | 700 | Mtrs | |
| 238 | 84.2 | Installation | 700 | Mtrs | |
| 239 | 85 | Supply, Installation and testing of 1100 V Grade PVC insulated, PVC sheathed unarmored single core copper Stranded conductor, Cable of 50 Sq. mm. size through Flexible GI conduit in approved manner on wall / on trays complete with dressing saddling clamping termination etc. Including civil work and required accessories spacers, clamps and hardware etc. | |||
| 240 | 85.1 | Material | 600 | Mtrs | |
| 241 | 85.2 | Installation | 600 | Mtrs | |
| 242 | 86 | Supply, Installation and testing of 1100 V Grade PVC insulated, PVC sheathed unarmored single core copper Stranded conductor, Cable of 35 Sq. mm. size through Flexible GI conduit in approved manner on wall / on trays complete with dressing saddling clamping termination etc. Including civil work and required accessories spacers, clamps and hardware etc. | |||
| 243 | 86.1 | Material | 350 | Mtrs | |
| 244 | 86.2 | Installation | 350 | Mtrs | |
| 245 | 87 | Excavation of cable trench having as per standard drawing in existing strata of soil, sand bedding, brick protection cover, plastic cover , back filling and making good as required as per standard specification and drawing. | |||
| 246 | 87.1 | Material | 250 | Cu. Mtr. | |
| 247 | 87.2 | Installation | 250 | Cu. Mtr. | |
| 248 | 88 | Providing 50 mm GI Conduit with accessories | |||
| 249 | 88.1 | Material | 500 | Nos | |
| 250 | 88.2 | Installation | 500 | Nos | |
| 251 | 89 | LIGHTING - POINT WIRING : Concealed points wiring for light, fan, 6A socket switch point, using ISI marked rigid GI 25 mm dia. Conduit along with heavy duty GI conduit accessories, GI boxes, switches, regulators, sockets, plug top, mounting plates, hardware, ceiling rose, holders, ball socket, anchor hooks, clamps etc. Wiring through GI conduit including termination.\n2 Nos. of 2.5 mm² copper conductor FRLS PVC wire for phase, neutral and 1.5 mm² copper conductor FRLS PVC wire for earthing will be used for- Primary Point includes conduiting and wiring from LDB to Switch Board, Switch Board to looped Switch Board and Switch Board to first point measured as one Primary point.\n3 Nos. of 1.5 mm² copper conductor FRLS PVC wire for phase, neutral and earthing will be used for- wiring from primary point to looped point said as Secondary Point\nPoint wiring will be done as per IE rules\n | |||
| 252 | 90 | Primary Light point | |||
| 253 | 90.1 | Material | 750 | Nos. | |
| 254 | 90.2 | Installation | 750 | Nos. | |
| 255 | 91 | Secondary Light point looped from above mentioned Primary Light point with distance up to 1 meter. | |||
| 256 | 91.1 | Material | 100 | Nos. | |
| 257 | 91.2 | Installation | 100 | Nos. | |
| 258 | 92 | Secondary Light point looped from above mentioned Primary Light point with distance over 1 meter. | |||
| 259 | 92.1 | Material | 3000 | Nos. | |
| 260 | 92.2 | Installation | 3000 | Nos. | |
| 261 | 93 | 6 A switch and 6A socket mounted on switchboard along with lighting switches. | |||
| 262 | 93.1 | Material | 50 | Nos. | |
| 263 | 93.2 | Installation | 50 | Nos. | |
| 264 | 94 | 6A switch and 6A socket mounted separately away from switch box on wall/partition. Wiring from nearest switch box through GI conduit embedded in wall or through partition. | |||
| 265 | 94.1 | Material | 50 | Nos. | |
| 266 | 94.2 | Installation | 50 | Nos. | |
| 267 | 95 | Exhaust Fan Point | |||
| 268 | 95.1 | Material | 50 | Nos. | |
| 269 | 95.2 | Installation | 50 | Nos. | |
| 270 | 96 | LIGHT FIXTURES | |||
| 271 | 97 | Providing following equipments along with accessories, hardware, down rods made out of 19mm 16 SWG GI conduit, ball and socket and check nut arrangement. In case of conduit with S.S. Chains/Gear Chain are used then same will be suspended from ceiling by ISI marked anodized anchor fasteners. Light fittings to be suspended individually at all four corners. | |||
| 272 | 98 | Providing of LED recessed Luminaire with a nomial system lumen output of 3000 lumens and a minimum system efficacy of 120 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L80 B50-50KHrs @ Ta :45 Degrees. The luminaire should have a color temperature of 4000K/6500k and CRI>80. Driver of the luminaire shall have THD<10% and PF >0.9. The luminaire housing should made of powder coated CRCA with high efficiency opal diffuser. The total power consumption should not exceed 25W (including driver) with 2KV surge protection. Leakage current should be as per as per IEC 60598 and Fixture should be EMC/EMI compliant. \nModel similar to Philips Make Full Glow RC380B LED30S-6500 L60W60 PSU OD S1 | |||
| 273 | 98.1 | Material | 225 | Nos. | |
| 274 | 98.2 | Installation | 225 | Nos. | |
| 275 | 99 | Providing of RECESSED LED Luminaire with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100lm/W. System wattage should not exceed 13W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L80. The luminaire should have a color temperature of3000K, 4000K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. The luminaire housing should be made of extruded Aluminium with PMMA diffuser. The driver shall comply to IEC 62384 , IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. \nModel similar to Philips Make Green LED i 1200 DN193B LED12S-6500 PSU WH S1 | |||
| 276 | 99.1 | Material | 1225 | Nos. | |
| 277 | 99.2 | Installation | 1225 | Nos. | |
| 278 | 100 | Providing of Surface mounted 4ft Luminaire Equivalent to Philips Make TCW450 P 1XTLED 18W/ 2100lm IP65 protection against dust and water | |||
| 279 | 100.1 | Material | 50 | Nos. | |
| 280 | 100.2 | Installation | 50 | Nos. | |
| 281 | 101 | Providing of recesseed Equivalent to Philips Make RS271 -2x 28W LED downlight with double bezzel plate | |||
| 282 | 101.1 | Material | 50 | Nos. | |
| 283 | 101.2 | Installation | 50 | Nos. | |
| 284 | 102 | Providing of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. System wattage should not exceed 20W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L80. The luminaire should have a color temperature of 4000K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. The luminaire housing should be made of CRCA with a PC glossy diffuser. Similar to Philips Make Endura LED Batten \"BN 108C LED 20S PSU NW WH\" | |||
| 285 | 102.1 | Material | 500 | Nos. | |
| 286 | 102.2 | Installation | 500 | Nos. | |
| 287 | 103 | Providing of RECESSED LED Luminaire with a nominal system lumen output of 700 lumens and a minimum system efficacy of 100lm/W. System wattage should not exceed 7W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L80. The luminaire should have a color temperature of3000K, 4000K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. The luminaire housing should be made of extruded Aluminium with PMMA diffuser. The driver shall comply to IEC 62384 , IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. \nModel similar to Philips Make Green LED i 600 DN191B LED6S-6500 PSU WH S1 | |||
| 288 | 103.1 | Material | 100 | Nos. | |
| 289 | 103.2 | Installation | 100 | Nos. | |
| 290 | 104 | Providing Square surface mounted 300x300 mm luminaire. With CRI>80 and SDCN<5. Body made of PC/CRCA and with Opal PMMA diffuser. THD should be <10% and with minimum 85% efficinecy. \nModel similar to Philips Make Cirrus mini Pro SM200C LED16S 6500 PSU OD WH | |||
| 291 | 104.1 | Material | 160 | Nos. | |
| 292 | 104.2 | Installation | 160 | Nos. | |
| 293 | 105 | Providing Surface mounted Bulkhead. The product should have THD <=20% with pf>0.9. The fixture should be IP66 and IK09 rated with high pressure die cast housing and PC diffuser. \nModel similar to Endura LED Bulkhead WT202W LED6S | |||
| 294 | 105.1 | Material | 150 | Nos. | |
| 295 | 105.2 | Installation | 150 | Nos. | |
| 296 | 106 | Providing of LED Highbay Luminarie, 100 W , 125 Lm/W \nEquivalent to Phiips Cat No. BY325P LED130s | |||
| 297 | 106.1 | Material | 575 | Nos. | |
| 298 | 106.2 | Installation | 575 | Nos. | |
| 299 | 107 | Supply Recessed 3W LED Downlight | |||
| 300 | 107.1 | Material | 50 | Nos. | |
| 301 | 107.2 | Installation | 50 | Nos. | |
| 302 | 108 | Providing of Decorative Light Fittings (upto Rs. 10,000/-) | |||
| 303 | 108.1 | Material | 5 | Nos. | |
| 304 | 108.2 | Installation | 5 | Nos. | |
| 305 | 109 | Providing of Decorative Chandelier Light Fittings (upto Rs. 1,00,000/-) | |||
| 306 | 109.1 | Material | 5 | Nos. | |
| 307 | 109.2 | Installation | 5 | Nos. | |
| 308 | 110 | Providing of PIR Sensors with contact rating of 10 Amps inductive, covering area of 8 meters at mounting height of 3 meter, occupancy Sensor \nEequivalent to Model no LRM 1070 of Philips Make | |||
| 309 | 110.1 | Material | 75 | Nos. | |
| 310 | 110.2 | Installation | 75 | Nos. | |
| 311 | 111 | POWER WIRING | |||
| 312 | 112 | Concealed points wiring for power plug point. | |||
| 313 | 113 | Concealed 16A power plug points includes for conduiting from RAW Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 16A switch, 16 A+6A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC wire for phase and 1.5 mm². Copper conductor PVC wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Two Nos. of Power points to be looped and will be measured as Two separate points. | |||
| 314 | 113.1 | Material | 400 | Nos. | |
| 315 | 113.2 | Installation | 400 | Nos. | |
| 316 | 114 | Concealed 16A power plug points includes for conduiting from AC DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 16A switch, 16 A+6A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC wire for phase and 1.5 mm². Copper conductor PVC wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Two Nos. of Power points to be looped and will be measured as Two separate points. | |||
| 317 | 114.1 | Material | 350 | Nos. | |
| 318 | 114.2 | Installation | 350 | Nos. | |
| 319 | 115 | Concealed 6A power plug points includes for conduiting from Raw Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 6A switch & 6 A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC FRLS wire for phase and 1.5 mm². Copper conductor PVC FRLS wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Six Nos. of Power points to be looped and will be measured as Six separate points. | |||
| 320 | 115.1 | Material | 250 | Nos. | |
| 321 | 115.2 | Installation | 250 | Nos. | |
| 322 | 116 | Concealed 6A power plug points includes for conduiting from AC DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 6A switch & 6 A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC FRLS wire for phase and 1.5 mm². Copper conductor PVC FRLS wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Six Nos. of Power points to be looped and will be measured as Six separate points. | |||
| 323 | 116.1 | Material | 100 | Nos. | |
| 324 | 116.2 | Installation | 100 | Nos. | |
| 325 | 117 | Concealed 20 A SPN BCH / Crompton Rey rolled porcelains socket and 20 A SP MCB housed in GI Box without wiring. Conduiting from DB to point as directed through wall/partition, by 25 mm ISI marked GI conduit, conduit accessories, plated pull boxes. Wiring by 2Nos. 2.5 Sq. mm. & 1 no. 1.5sq.mm copper conductor PVC insulated multicore flexible cable through GI conduit including termination. | |||
| 326 | 117.1 | Material | 50 | Nos. | |
| 327 | 117.2 | Installation | 50 | Nos. | |
| 328 | 118 | Providing 32 AMPS Single phase Power point with 32 A SP MCB & Industrial Socket, and wiring with 2 Nos 4 mm and 1 No. 2.5 sq mm PVC insulated copper FRLS wire from DB to point as directed through GI Conduit and GI conduit accessories. | |||
| 329 | 118.1 | Material | 15 | Nos. | |
| 330 | 118.2 | Installation | 15 | Nos. | |
| 331 | 119 | Providing 20 AMPS Single phase Power point with 32 A SP MCB & Industrial Socket, and wiring with 2 Nos 4 mm and 1 No. 2.5 sq mm PVC insulated copper FRLS wire from DB to point as directed through GI Conduit and GI conduit accessories. | |||
| 332 | 119.1 | Material | 15 | Nos. | |
| 333 | 119.2 | Installation | 15 | Nos. | |
| 334 | 120 | Providing 32 AMPS Three phase Power point with 32 A TPN MCB & Industrial Socket, and wiring with 3 Nos 4 mm and 2 Nos. 2.5 sq mm PVC insulated copper FRLS wire from DB/Panel to point as directed through GI Conduit and GI conduit accessories. | |||
| 335 | 120.1 | Material | 10 | Nos. | |
| 336 | 120.2 | Installation | 10 | Nos. | |
| 337 | 121 | Providing 63 Amp Three phase Power point comprising of 63 Amp socket and MCB in IP 56 weather proof enclosure and wiring with 3 Nos 10 sq mm and 2 Nos.6 Sqmm PVC insulated copper FRLS wire from DB/Panel to point as directed through GI Conduit and GI conduit accessories. | |||
| 338 | 121.1 | Material | 10 | Nos. | |
| 339 | 121.2 | Installation | 10 | Nos. | |
| 340 | 122 | Imigration Counter Raw Point\nConcealed 16A+6A, 6A switch socket combined power point as Power Point.\nProviding concealed Power Point wiring for – 2 Nos. of 16A+6A Socket Controlled by 2 Nos.16A switch in housing as mentioned below. \nConduiting from J. B. of Power Raceway embedded in floor to point as directed through wall/partition, by 25 mm ISI marked GI conduit, conduit accessories, plated MS pull boxes. Wiring by 3 Core 2.5 Sq. mm. copper conductor PVC FRLS insulated and overall PVC sheathed multicore flexible Grey color cable through GI conduit and raceway including termination. Cost of providing raceways will be covered in separate item mentioned elsewhere. No point to be looped.\n | |||
| 341 | 122.1 | Material | 150 | Nos. | |
| 342 | 122.2 | Installation | 150 | Nos. | |
| 343 | 123 | UPS POWER WIRING | |||
| 344 | 124 | Concealed switch socket combined power point as UPS Point. | |||
| 345 | 125 | Concealed 16A power plug points includes for conduiting from UPS Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 16A switch, 16 A+6A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC FRLS wire for phase and 1.5 mm². Copper conductor PVC FRLS wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Two Nos. of Power points to be looped and will be measured as Two separate points. | |||
| 346 | 125.1 | Material | 150 | Nos. | |
| 347 | 125.2 | Installation | 150 | Nos. | |
| 348 | 126 | Concealed 13A power plug points includes for conduiting from UPS Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 16A switch, 13A Universal sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC FRLS wire for phase and 1.5 mm². Copper conductor PVC FRLS wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Two Nos. of Power points to be looped and will be measured as Two separate points. | |||
| 349 | 126.1 | Material | 20 | Nos. | |
| 350 | 126.2 | Installation | 20 | Nos. | |
| 351 | 127 | Concealed 3 x 13A soxket with 1 no. of 16A switch power plug points includes for conduiting from UPS Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 16A switch, 13A Universal sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC FRLS wire for phase and 1.5 mm². Copper conductor PVC FRLS wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Four Nos. of Power points to be looped and will be measured as Fouro separate points. | |||
| 352 | 127.1 | Material | 40 | Nos. | |
| 353 | 127.2 | Installation | 40 | Nos. | |
| 354 | 128 | Concealed 6A power plug points includes for conduiting from UPS Power DB to point as directed, by 25 mm ISI marked GI conduit, conduit accessories, pull boxes, plates, 6A switch, 6 A sockets, wiring by 2 nos. of 2.5 mm². Copper conductor PVC wire for phase and 1.5 mm². Copper conductor PVC wire for earthing through GI conduit including termination, as shown from D.B. to power point. Maximum Four Nos. of Power points to be looped or as directed and will be measured as Four separate points. | |||
| 355 | 128.1 | Material | 100 | Nos. | |
| 356 | 128.2 | Installation | 100 | Nos. | |
| 357 | 129 | Concealed 32 A Single Phase 250V, 2P+E Mobile socket and straight plug IP44 in GI Box.\nConduiting from DB to point as directed through wall/partition, by 25 mm ISI marked GI conduit, conduit accessories, plated pull boxes. Wiring by 3C x 4 sq.mm copper conductor PVC insulated multicore flexible cable through GI conduit including termination.\n | |||
| 358 | 129.1 | Material | 15 | Nos. | |
| 359 | 129.2 | Installation | 15 | Nos. | |
| 360 | 130 | Points For Racks | |||
| 361 | 131 | Surface 32 A Single Phase 250V, 2P+E Mobile socket and straight plug IP44 in GI Box. Cabling from DB to point located under/above Rack as directed through cable tray or trunking. Wiring by 3C x 6 sq mm Copper conductor PVC insulated cable including termination. | |||
| 362 | 131.1 | Material | 13 | Nos. | |
| 363 | 131.2 | Installation | 13 | Nos. | |
| 364 | 132 | Imigration Counter Raw Point | |||
| 365 | 133 | Concealed 16A+6A, 6A switch socket combined power point as UPS Point.\nProviding concealed Power Point wiring for – 2 Nos. of 16A+6A Socket Controlled by 2 Nos.16A switch in housing as mentioned below. Conduiting from J. B. of UPS Power Raceway embedded in floor to point as directed through wall/partition, by 25 mm ISI marked GI conduit, conduit accessories, plated MS pull boxes. Wiring by 3 Core 2.5 Sq. mm. copper conductor PVC FRLS insulated and overall PVC sheathed multicore flexible Grey color cable through GI conduit and raceway including termination. Cost of providing raceways will be covered in separate item mentioned elsewhere. No point to be looped.\n | |||
| 366 | 133.1 | Material | 150 | Nos. | |
| 367 | 133.2 | Installation | 150 | Nos. | |
| 368 | 134 | EARTHING | |||
| 369 | 135 | Providing Earthing pit by auguring and installation of Copper Coated electrolytically bonded 250 micron MS Earth Rod of 17.2 mm dia 3 mtr long Earth enhancement compund 25 Kg , connector for testing link complete with inspection chamber made out of brick masonary and cast iron inspection cover duly painted and marked. | |||
| 370 | 135.1 | Material | 2 | Nos. | |
| 371 | 135.2 | Installation | 2 | Nos. | |
| 372 | 136 | Providing 3 meters Earthing having pipe in pipe technology with cast iron pipe outside and GI pipe inside duly filled by chemical for conductivity. | |||
| 373 | 136.1 | Material | 2 | No | |
| 374 | 136.2 | Installation | 2 | No | |
| 375 | 137 | Providing single core 95 mm² copper conductor PVC FRLS insulated PVC sheathed cable in GI conduit with Termination. | |||
| 376 | 137.1 | Material | 500 | Mtrs | |
| 377 | 137.2 | Installation | 500 | Mtrs | |
| 378 | 138 | Providing single core 70 mm² copper conductor PVC FRLS insulated PVC sheathed cable in GI conduit with Termination. | |||
| 379 | 138.1 | Material | 100 | Mtrs | |
| 380 | 138.2 | Installation | 100 | Mtrs | |
| 381 | 139 | Providing single core 35 mm² copper conductor PVC FRLS insulated PVC sheathed cable in GI conduit with Termination. | |||
| 382 | 139.1 | Material | 750 | Mtrs | |
| 383 | 139.2 | Installation | 750 | Mtrs | |
| 384 | 140 | Providing single core 16 mm² copper conductor PVC FRLS insulated PVC sheathed cable in GI conduit with Termination. | |||
| 385 | 140.1 | Material | 1000 | Mtrs | |
| 386 | 140.2 | Installation | 1000 | Mtrs | |
| 387 | 141 | Providing single core 10 mm² copper conductor PVC FRLS insulated PVC sheathed cable in GI conduit with Termination. | |||
| 388 | 141.1 | Material | 4000 | Mtrs | |
| 389 | 141.2 | Installation | 4000 | Mtrs | |
| 390 | 142 | Providing single core 2.5 mm² copper conductor PVC FRLS insulated PVC sheathed cable with Termination. | |||
| 391 | 142.1 | Material | 500 | Mtrs | |
| 392 | 142.2 | Installation | 500 | Mtrs | |
| 393 | 143 | Providing single core 1.5 mm² copper conductor PVC FRLS insulated PVC sheathed cable with Termination | |||
| 394 | 143.1 | Material | 500 | Mtrs | |
| 395 | 143.2 | Installation | 500 | Mtrs | |
| 396 | 144 | Providing copper earth Busbar of size 450 mm x 50 mm x 4 mm mounted on insulators having holes on it with termination arrangement, nut bolts etc. Fitted in ms junction box with acrylic cover. | |||
| 397 | 144.1 | Material | 10 | Nos | |
| 398 | 144.2 | Installation | 10 | Nos | |
| 399 | 145 | Providing copper earth Busbar of size 300 mm x 50 mm x 4 mm mounted on insulators having holes on it with termination arrangement, nut bolts etc. Fitted in ms junction box with acrylic cover. | |||
| 400 | 145.1 | Material | 30 | Nos | |
| 401 | 145.2 | Installation | 30 | Nos | |
| 402 | 146 | Providing 50 mm x 6 mm GI earthing flat | |||
| 403 | 146.1 | Material | 4000 | Mtrs | |
| 404 | 146.2 | Installation | 4000 | Mtrs | |
| 405 | 147 | Providing 50 mm x 6 mm Cu earthing flat | |||
| 406 | 147.1 | Material | 850 | Mtrs | |
| 407 | 147.2 | Installation | 850 | Mtrs | |
| 408 | 148 | Providing 32 mm x 6 mm GI earthing flat | |||
| 409 | 148.1 | Material | 3800 | Mtrs | |
| 410 | 148.2 | Installation | 3800 | Mtrs | |
| 411 | 149 | Providing 25 mm x 6 mm GI earthing flat | |||
| 412 | 149.1 | Material | 200 | Mtrs | |
| 413 | 149.2 | Installation | 200 | Mtrs | |
| 414 | 150 | Providing 12 SWG copper earthing wire | |||
| 415 | 150.1 | Material | 4000 | Mtrs | |
| 416 | 150.2 | Installation | 4000 | Mtrs | |
| 417 | 151 | Providing 8SWG Copper earthing wire. | |||
| 418 | 151.1 | Material | 1000 | Mtrs | |
| 419 | 151.2 | Installation | 1000 | Mtrs | |
| 420 | 152 | Providing 25 mm x 3 mm CU. earthing flat | |||
| 421 | 152.1 | Material | 400 | Mtrs | |
| 422 | 152.2 | Installation | 400 | Mtrs | |
| 423 | 153 | Providing 25 mm x 3 mm GI. earthing flat | |||
| 424 | 153.1 | Material | 1000 | Mtrs | |
| 425 | 153.2 | Installation | 1000 | Mtrs | |
| 426 | 154 | Supply of conventional type lightning arrestor with 100MM dia copper spheare with 5 nos spike and 1.5 Mtr copper pole with base plate. | |||
| 427 | 154.1 | Material | 2 | Set | |
| 428 | 154.2 | Installation | 2 | Set | |
| 429 | 155 | DATA VOICE CONDUITING | |||
| 430 | 156 | Providing MS box for DATA/VOICE socket point | |||
| 431 | 156.1 | Material | 100 | Nos. | |
| 432 | 156.2 | Installation | 100 | Nos. | |
| 433 | 157 | 50 mm. rigid GI ISI marked conduit with conduit accessories | |||
| 434 | 157.1 | Material | 500 | Mtr. | |
| 435 | 157.2 | Installation | 500 | Mtr. | |
| 436 | 158 | 50 mm. flexible GI ISI marked conduit with conduit accessories | |||
| 437 | 158.1 | Material | 500 | Mtr. | |
| 438 | 158.2 | Installation | 500 | Mtr. | |
| 439 | 159 | Providing 25 mm GI ISI marked Rigid conduit for Data/Voice/AV with accessories. | |||
| 440 | 159.1 | Material | 1000 | Mtr. | |
| 441 | 159.2 | Installation | 1000 | Mtr. | |
| 442 | 160 | CABLE TV | |||
| 443 | 161 | 25mm dia ISI marked rigid GI conduit for T. V. points along with medium duty GI conduit accessories, splitters, J. B.s, electro plated Pull Boxes etc. on surface in Duct & concealed in floors, through floors slab, wall etc. | |||
| 444 | 161.1 | Material | 2500 | Mtr. | |
| 445 | 161.2 | Installation | 2500 | Mtr. | |
| 446 | 162 | TV coaxial cable of RG-11 size with copper conductor. | |||
| 447 | 162.1 | Material | 2750 | Mtr. | |
| 448 | 162.2 | Installation | 2750 | Mtr. | |
| 449 | 163 | Providing TV socket outlet in plated GI box. | |||
| 450 | 163.1 | Material | 50 | Nos. | |
| 451 | 163.2 | Installation | 50 | Nos. | |
| 452 | 164 | OTHER ITEMS | |||
| 453 | 165 | Emergency Point, by using 25 mm dia GI ISI marked conduit and with GI accessories, 3 Nos. of 2.5 sq. mm. PVC FRLS insulated copper conductor wires to various points from Emergency DB to Emergency switch Board to Emergency Point. Maximum six points will be looped together. Same phase sequence to be maintained with respect to adjacent light fitting. | |||
| 454 | 165.1 | Material | 1000 | Nos. | |
| 455 | 165.2 | Installation | 1000 | Nos. | |
| 456 | 166 | CABLE SUPPORTS | |||
| 457 | 167 | Providing Structural fabrication for Cable Tray supports made out of Angle/C-Channel, plate, Anchor fasteners etc in wall/ceiling including supply of steel, cutting, welding, drilling, erecting at site including consumables like welding rods, gas drill bits etc. Job also includes for minor civil work, duly Painted with two coats of Red oxide and two coats of Synthetic namel paint of grade 631. | |||
| 458 | 167.1 | Material | 1500 | Kg. | |
| 459 | 167.2 | Installation | 1500 | Kg. | |
| 460 | 168 | Providing FRP ladder type Cable Tray made out of FRP sheet as per drawing having following width with supporting structure duly painted with two coats of red oxide and two coats of enamal paint. Steel structure will be measured and paid saperately against steel structure item. | |||
| 461 | 169 | 1000 mm width x 75 mm x 4mm Thick | |||
| 462 | 169.1 | Material | 850 | Mtrs. | |
| 463 | 169.2 | Installation | 850 | Mtrs. | |
| 464 | 170 | 750 mm width x 75 mm x 4mm Thick | |||
| 465 | 170.1 | Material | 300 | Mtrs. | |
| 466 | 170.2 | Installation | 300 | Mtrs. | |
| 467 | 171 | 600 mm width x 75 mm x 4mm Thick | |||
| 468 | 171.1 | Material | 850 | Mtrs. | |
| 469 | 171.2 | Installation | 850 | Mtrs. | |
| 470 | 172 | 450 mm width x 75 mm x 4mm Thick | |||
| 471 | 172.1 | Material | 500 | Mtrs. | |
| 472 | 172.2 | Installation | 500 | Mtrs. | |
| 473 | 173 | 300 mm width x 75 mm x 3 mm Thick | |||
| 474 | 173.1 | Material | 500 | Mtrs. | |
| 475 | 173.2 | Installation | 500 | Mtrs. | |
| 476 | 174 | 150 mm width x 75 mm x 3 mm Thick | |||
| 477 | 174.1 | Material | 200 | Mtrs. | |
| 478 | 174.2 | Installation | 200 | Mtrs. | |
| 479 | 175 | Providing 600 mm x 75 mm x 3mm FRP Perforated type Cable Tray with removable cover of 3 mm. Job includes providing cable Raceway and it’s supports / hangers installation with supporting structure duly painted with two coats of red oxide and two coats of enamal paint. Steel structure will be measured and paid saperately against steel structure item. | |||
| 480 | 175.1 | Material | 1200 | Mtrs. | |
| 481 | 175.2 | Installation | 1200 | Mtrs. | |
| 482 | 176 | Providing 450 mm x 75 mm x 3 mm FRP Perforated type Cable Tray with removable cover of 3 mm. Job includes providing cable Raceway and it’s supports / hangers installation. with supporting structure duly painted with two coats of red oxide and two coats of enamal paint. Steel structure will be measured and paid saperately against steel structure item. | |||
| 483 | 176.1 | Material | 1000 | Mtrs. | |
| 484 | 176.2 | Installation | 1000 | Mtrs. | |
| 485 | 177 | Providing 300 mm x 75 mm x 3 mm FRP Perforated type Cable Tray with removable cover of 3 mm. Job includes providing cable Raceway and it’s supports / hangers installation. with supporting structure duly painted with two coats of red oxide and two coats of enamal paint. Steel structure will be measured and paid saperately against steel structure item. | |||
| 486 | 177.1 | Material | 1000 | Mtrs. | |
| 487 | 177.2 | Installation | 1000 | Mtrs. | |
| 488 | 178 | UNDER FLOOR RACEWAYS | |||
| 489 | 179 | Providing raceways below false floor Comprising rectangular aluminum extruded tubes. Cleaning wherever necessary, fixing the raceways, minor civil work with providing sealing at joints at junction boxes and proper alignment, vacuum cleaning and connection of following sizes. Job also includes of data/voice/power conduit supply and installation. | |||
| 490 | 180 | 100 x 40mm x2mm thick Al Raceway | |||
| 491 | 180.1 | Material | 1500 | Mtrs. | |
| 492 | 180.2 | Installation | 1500 | Mtrs. | |
| 493 | 181 | 80 x 40mm x2mm thick Al Raceway | |||
| 494 | 181.1 | Material | 750 | Mtrs. | |
| 495 | 181.2 | Installation | 750 | Mtrs. | |
| 496 | 182 | 40 x 40mm x2mm thick Al Raceway | |||
| 497 | 182.1 | Material | 750 | Mtrs. | |
| 498 | 182.2 | Installation | 750 | Mtrs. | |
| 499 | 183 | Providing junction boxes for aforesaid raceways fabricated out of MS sheet with powder coating, having following sizes made out of 1.6 mm thick sheet, 50 mm deep, with cut outs for raceways and Cover plate of the junction box. | |||
| 500 | 184 | Junction Box of size 200 mm x 200 mm. | |||
| 501 | 184.1 | Material | 450 | Nos. | |
| 502 | 184.2 | Installation | 450 | Nos. | |
| 503 | 185 | Junction Box of size 300 mm x 300 mm. | |||
| 504 | 185.1 | Material | 200 | Nos. | |
| 505 | 185.2 | Installation | 200 | Nos. | |
| 506 | 186 | Junction Box of size 350 mm x 350 mm. | |||
| 507 | 186.1 | Material | 25 | Nos. | |
| 508 | 186.2 | Installation | 25 | Nos. | |
| 509 | 187 | Junction Box of size 500 mm x 500 mm. | |||
| 510 | 187.1 | Material | 25 | Nos. | |
| 511 | 187.2 | Installation | 25 | Nos. | |
| 512 | 188 | Providing Table Top Popup Boxes rated for 230V AC, ABS-FR, low concentration of heavy metal, aluminum casing, gounded to protect against electrical shock in Gang Box of configuration mentioned below- Equivalent to A.H. Meyer\n12 Module Box, 3 Nos. International Socket + 1 No. International Socket + 2 Nos. 16A Switch, Provision of space with balanking cover for 2 Nos. LAN Ports. | |||
| 513 | 188.1 | Material | 50 | Nos. | |
| 514 | 188.2 | Installation | 50 | Nos. | |
| 515 | 189 | Rubber Mat of 1Mtr x 2Mtr, 12mm size for electrical & ups room | |||
| 516 | 189.1 | Material | 35 | Nos. | |
| 517 | 189.2 | Installation | 35 | Nos. | |
| 518 | 190 | Resuscitation chart | |||
| 519 | 190.1 | Material | 40 | Nos. | |
| 520 | 190.2 | Installation | 40 | Nos. | |
| 521 | 191 | UPS & Batteries\nSupply, Installation, Testing and Commissioning of UPS having rating given as under and as specified. \nUPS should be true ON Line Double conversion technology with pure sine wave output. \nUPS should be without Isolation Transformer.\nTechnology in UPS should be with IGBT Rectifier & Inverter with IGBT. \nIt should be achieving current harmonics of less than 5% for 100% computer load.\nUPS should have-\n1) Emergency Power Off to be provided, which can be connected through Fire suppression system.\n2) BMS compatible facility with communication card, Auto dialer facility.\n3) Report generation facility on UPS to track the history of UPS status.\n4) Minimum four Potential free contacts. \n5) Static Bypass \n6) Maintenance Bypass\n7) Synchronizing circuit\n8) 4 Nos potential free contacts\n9) Filter cut off arrangement in case of input pf goes to leading. \n10) Monitoring and control system shall be state of the art technology LCD Panel Type, providing all relevant data. \n11) Contact in UPS suitable to be used for tripping of MCCB provided by electrical contractor. In case UPS is in `ON` it will operate\nJob includes cabling & cable tray between UPS, STS and batteries.\nCommissioning of UPS will be done with load testing with heater load arrangement.\n | |||
| 522 | 191.1 | Providing 30 KVA UPS 3 phase In & 3 phase out without isolation transformer.UPS will be with VRLA SMF Battery Backup of 90 minutes. | |||
| 523 | 191.2 | Material | 1 | No. | |
| 524 | 192 | Installation | 1 | No. | |
| 525 | 193 | Providing 60 KVA UPS 3 phase In & 3 phase out without isolation transformer.UPS will be with VRLA SMF Battery Backup of 30 minutes. | |||
| 526 | 193.1 | Material | 1 | No. | |
| 527 | 193.2 | Installation | 1 | No. | |
| 528 | 194 | EXTERNAL LIGHTING | |||
| 529 | 195 | PANELS & D.B.S | |||
| 530 | 196 | Providing Panel / Power distribution Boards suitable for 415V 50Hz 3ph 4 wire supply dust and vermin proof floor/ wall mounting cubicle pattern with removable gland plates, copper bus bar, mounting frame, grouting made out of crca sheet, double door, duly powder coated painted as specified as follows. MCB with ‘c’ curve for lighting & power, d curve will be used for PC. | |||
| 531 | 197 | EXTERNAL LIGHTING PANEL\nComprising of:\nIncoming –\n160 Amp TPN MCCB, 25 kA, Microprocessor Over current, Short circuit and 3Ph 4 Wire Earth fault - 1No., Three Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set\nLM-ET5011- V, A, Hz, KVA, KVAR, PF, KVA, Rh, THD for A&V MD KVA Load Manager with RS 485 -1 set\nCopper Bus Bars of 160 Amp TPN 25 kA for 1 sec. - 1 Set, 40kA Class (B+C) Surge Suppressor -1 No., Auto Manual Switch with Astronomical Timer\nOutgoing –\n63 Amp. TPN MCCB - 18 No\n | |||
| 532 | 197.1 | Material | 1 | No. | |
| 533 | 197.2 | Installation | 1 | No. | |
| 534 | 198 | FACADE LIGHTING PANEL-1\nComprising of:\nIncoming –125 Amp TPN MCCB, 25 kA, Microprocessor Over current, Short circuit and 3Ph 4 Wire Earth fault - 1No., Three Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set, \nLM-1 - ET5011- V, A, Hz, KVA, KVAR, PF, KVARh, THD for A&V MD KVA Load Manager with RS 485 -1 set, Copper Bus Bars of 125 Amp TPN 25 kA for 1 sec. - 1 Set., 40kA Class (B+C) Surge Suppressor -1 No., Auto Manual Switch with Astronomical Timer\nOutgoing –\n20 Amp. TPN MCCB - 15 No.\n | |||
| 535 | 198.1 | Material | 2 | Nos. | |
| 536 | 198.2 | Installation | 2 | Nos. | |
| 537 | 199 | FACADE LIGHTING PANEL-2\nComprising of:\nIncoming – 63 Amp TPN MCCB, 25 kA, Microprocessor Over current, Short circuit and 3Ph 4 Wire Earth fault - 1No.\nThree Nos. Phase Indicating Lamps, Control fuses- Voltmeter with Selector switch –1 set, Ammeter with selector switch -1 set\nCopper Bus Bars of 125 Amp TPN 25 kA for 1 sec. - 1 Set.\n20kA Class (C) Surge Supressor -1 No., Auto Manual Switch with Astronomical Timer\nOutgoing – 10 Amp. TPN MCCB - 32 No\n | |||
| 538 | 199.1 | Material | 2 | Nos. | |
| 539 | 199.2 | Installation | 2 | Nos. | |
| 540 | 200 | CABLES | |||
| 541 | 201 | Providing 1.1KV stranded copper / aluminum conductor 3½ core XLPE insulated conductor and insulation , flat steel wires armoring, tough heat resisting outer sheets of following sizes. | |||
| 542 | 202 | 3½ C x 95 Sq. mm. A2XFY | |||
| 543 | 202.1 | Material | 300 | Mtr. | |
| 544 | 202.2 | Installation | 300 | Mtr. | |
| 545 | 203 | 3½ C x 70 Sq. mm. A2XFY | |||
| 546 | 203.1 | Material | 300 | Mtr. | |
| 547 | 203.2 | Installation | 300 | Mtr. | |
| 548 | 204 | 4 C x 25 Sq. mm. A2XFY | |||
| 549 | 204.1 | Material | 1720 | Mtr. | |
| 550 | 204.2 | Installation | 1720 | Mtr. | |
| 551 | 205 | Providing of 1100 V Grade PVC insulated, PVC sheathed GI wire armored multicore copper Stranded conductor, Cable of following sizes to be laid in prepared trenches/ excavated trenches/ on wall / on trays complete with dressing saddling clamping etc. Including civil work and required accessories spacers, clamps and hardware etc. | |||
| 552 | 206 | 4 C x 6 Sq. mm. YRY | |||
| 553 | 206.1 | Material | 11000 | Mtr. | |
| 554 | 206.2 | Installation | 11000 | Mtr. | |
| 555 | 207 | 4 C x 4 Sq. mm. YRY | |||
| 556 | 207.1 | Material | 2100 | Mtr. | |
| 557 | 207.2 | Installation | 2100 | Mtr. | |
| 558 | 208 | 3 C x 6 Sq. mm. YRY | |||
| 559 | 208.1 | Material | 500 | Mtr. | |
| 560 | 208.2 | Installation | 500 | Mtr. | |
| 561 | 209 | Providing of Termination of cables with double compression Brass cable gland including gland earthing and with crimping type copper lugs suitable for copper conductor cable with consumable such as tape, hard ware. | |||
| 562 | 210 | 3½ C x 95 Sq. mm. A2XFY | |||
| 563 | 210.1 | Material | 8 | Nos. | |
| 564 | 210.2 | Installation | 8 | Nos. | |
| 565 | 211 | 3½ C x 70 Sq. mm. A2XFY | |||
| 566 | 211.1 | Material | 8 | Nos. | |
| 567 | 211.2 | Installation | 8 | Nos. | |
| 568 | 212 | 4 C x 25 Sq. mm. A2XFY | |||
| 569 | 212.1 | Material | 98 | Nos. | |
| 570 | 212.2 | Installation | 98 | Nos. | |
| 571 | 213 | Providing of Termination of cables with double compression Brass cable gland including gland earthing and with crimping type copper lugs suitable for copper conductor cable with consumable such as tape, hard ware. | |||
| 572 | 214 | 4 C x 6 Sq. mm. YRY | |||
| 573 | 214.1 | Material | 300 | Nos. | |
| 574 | 214.2 | Installation | 300 | Nos. | |
| 575 | 215 | 4 C x 4 Sq. mm. YRY | |||
| 576 | 215.1 | Material | 114 | Nos. | |
| 577 | 215.2 | Installation | 114 | Nos. | |
| 578 | 216 | 3 C x 6 Sq. mm. YRY | |||
| 579 | 216.1 | Material | 70 | Nos. | |
| 580 | 216.2 | Installation | 70 | Nos. | |
| 581 | 217 | LIGHTING | |||
| 582 | 218 | Providing following equipments along with accessories, hardware, down rods made out of 19mm 14 SWG MS enamel painted conduit, ball and socket and check nut arrangement. In case of conduit with S.S. Chains are used then same will be suspended from ceiling by ISI marked anodized anchor fasteners. Light fittings to be suspended individually at all four corners. Providing LED fitting with sutiable Driver approved by Architect/Consultant having following Cat Number. | |||
| 583 | 219 | Providing 8 meter decorative poles made out of combination of GI & CI with double arm decorative bracket, anchor bolts, looping box of IP66 grade, suitable 2/3way terminal block along with LED of 135w, IP66. The cost of LED is deemed to be included in the quoted price.The Junction box will be placed inside the pole to improve the asthetic look in a window cut at the bottom neatly places the connector, MCB, Earthing point for loop in loop out arrangement. The Pole consist of a base plate having 16-25mm thickness. Pole to be mounted with suitable foundation of 1.5-3mtr alongwith suitable mounting accessories like foundation bolts, base plate etc... Street LIght Fixture to be mounted on ARM with termination cable running from pole base internally in absence of external junction box.\nEquivalent to Dwaraka Cat. No. DLP-3-80-302 | |||
| 584 | 219.1 | Material | 40 | Nos. | |
| 585 | 219.2 | Installation | 40 | Nos. | |
| 586 | 220 | Providing 8 meter decorative poles made out of combination of GI & CI with Four arm decorative bracket, anchor bolts, looping box of IP66 grade, suitable 2/3way terminal block along with LED of 135w, IP66. The cost of LED is deemed to be included in the quoted price.The Junction box will be placed inside the pole to improve the asthetic look in a window cut at the bottom neatly places the connector, MCB, Earthing point for loop in loop out arrangement. The Pole consist of a base plate having 16-25mm thickness. Pole to be mounted with suitable foundation of 1.5-3mtr alongwith suitable mounting accessories like foundation bolts, base plate etc... Street LIght Fixture to be mounted on ARM with termination cable running from pole base internally in absence of external junction box.\nEquivalent to Dwaraka Cat. No. DBP-002 | |||
| 587 | 220.1 | Material | 4 | Nos. | |
| 588 | 220.2 | Installation | 4 | Nos. | |
| 589 | 221 | OTHER WORKS | |||
| 590 | 222 | Providing Out door IP 65 Junction Boxes for termination of cables of size 100 mm x 100 mm. | |||
| 591 | 222.1 | Material | 50 | Nos. | |
| 592 | 222.2 | Installation | 50 | Nos. | |
| 593 | 223 | Providing Out door IP 65 Junction Boxes for termination of cables of size 200 mm x 200 mm. | |||
| 594 | 223.1 | Material | 50 | Nos. | |
| 595 | 223.2 | Installation | 50 | Nos. | |
| 596 | 224 | IP 65 Out door cable male female gas filled termination kit for terminating cables. | |||
| 597 | 224.1 | Material | 100 | Nos. | |
| 598 | 224.2 | Installation | 100 | Nos. | |
| 599 | 225 | Providing 350 x 350 mm Square Concrete base for mounting Outdoor Shrub light and Bollards | |||
| 600 | 225.1 | Material | 75 | Nos. | |
| 601 | 225.2 | Installation | 75 | Nos. | |
| 602 | 226 | Excavation of 450 mm wide 600 mm deep in existing strata of soil with horizontal accross bricks on top of cables, sand bedding of 50 mm above and bellow cable & Back filling and making good as per existing condition. for External Lighting cable work | |||
| 603 | 226.1 | Material | 100 | Cu. Mtr | |
| 604 | 226.2 | Installation | 100 | Cu. Mtr | |
| 605 | 227 | Providing 50 mm GI Conduit with accessories | |||
| 606 | 227.1 | Material | 50 | Mtrs. | |
| 607 | 227.2 | Installation | 50 | Mtrs. | |
| 608 | 228 | Providing Structural fabrication for supports made out of 40 x 40 x 3mm angle, plate, Anchor fasteners etc in wall/ceiling including supply of steel, cutting, welding, drilling, erecting at site including consumables like welding rods, gas drill bits etc. Job also includes for minor civil work, duly Painted with two coats of Red oxide and two coats of Synthetic namel paint of grade 631. | |||
| 609 | 228.1 | Material | 450 | Kgs | |
| 610 | 228.2 | Installation | 450 | Kgs | |
| 611 | 229 | Providing Hot Dipped Galvanised ladder type Cable Tray made out of 14 SWG MS sheet steel as per drawing having following width with two sets of GI Full threaded 6mm GI Bolts, Nuts and two numbers of 50mm Anchor Fasners duly installed on slab. | |||
| 612 | 230 | 150 mm width x 75 mm | |||
| 613 | 230.1 | Material | 500 | Mtrs. | |
| 614 | 230.2 | Installation | 500 | Mtrs. | |
| 615 | 231 | EARTHING | |||
| 616 | 232 | Providing ASHLOK make 3 meters Earthing having pipe in pipe technology with cast iron pipe outside and GI pipe inside duly filled by chemical for conductivity. | |||
| 617 | 232.1 | Material | 2 | Nos. | |
| 618 | 232.2 | Installation | 2 | Nos. | |
| 619 | 233 | Providing 50 mm x 6 mm GI earthing flat | |||
| 620 | 233.1 | Material | 100 | Mtrs. | |
| 621 | 233.2 | Installation | 100 | Mtrs. | |
| 622 | 234 | Providing 8SWG Copper earthing wire. | |||
| 623 | 234.1 | Material | 5000 | Mtrs. | |
| 624 | 234.2 | Installation | 5000 | Mtrs. |