Supply Of Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439 Standard At Bbq Coalyard Remote Sub-Station.Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439

Tender Notice

27729337
Supply Of Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439 Standard At Bbq Coalyard Remote Sub-Station.Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439
Indian
Tamil Nadu
22-04-2021
14-05-2021

Tender Details

Supply Of Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439 Standard At Bbq Coalyard Remote Sub-Station.Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439 Standard At Bbq Coalyard Remote Sub-Station.,Supply, Erection, Testing, Commissioning Of Indoor Type Tested Assembly (Tta) Panel As Per Iec-61439 Standard At Bbq Coalyard Remote Sub-Station And Consisting Of Electrolytic Copper Bus Bar Connection, Bus Bar Chamber, Cable Chamber And Fabricated With 14Swg Crca Sheet With 9 Tank Pre- Treatment And Powder Coating As Per Specification Along With Interconnecting Suitable Bus Bars, Ct, Numerical Relay, Digital Multifunction Meter Suitable For Communication Over Rs 485 Port And Consisting Of Switchgears (Attached To The Tender) To Be Supplied As Per Specification. Any Item Required For Successful Design & Working Of The Panels As Per Intended Use Shall Be Considered At Bidders End Without Any Cost Implications Post Bidding Stage. The Panel Design & Feeder Arrangment Shall Follow The Enclosed Sld Groupings For Ease Of Isolation Of Essential & Non Essential Feeders As Per Operational Needs. Since There Is A Strict Restriction On The Available Space For Panel Installation, Bidders Are Recommended To Visit The Site For Understanding Actual Requirements For Successful Installation Of The Panel Board Being Supplied. It Shall Be Bidders Responsibility To Study The Site Requirements And Take Into Account All Required Items For Successfull Design, Supply, Erection & Commissioning Of The Panels Any Claims Whatsoever Shall Not Be Entertained Under Any Circumstances Post Bid Submission. Switchgear Details, Sld And Specification Of Lt Panel Attached. The Panel To Be Installed At A Height Of 30 Cm From The Existing Floor Level.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
1964775.pdf Tender Document 1,005.1 KB
1964782.pdf Tender Document 378.0 KB
1964790.pdf Tender Document 287.6 KB
1964796.pdf Tender Document 2.1 MB
aecba732-2954-4be6-8809-0aca8c894d79.pdf Tender Notice 46.3 KB

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Sl. No. Item Description
1Supply, Erection, Testing, Commissioning of Indoor Type Tested Assembly (TTA) Panel as per IEC-61439 standard at BBQ Coalyard Remote Sub-station.
2Supply, Erection, Testing, Commissioning of Indoor Type Tested Assembly (TTA) Panel as per IEC-61439 standard at BBQ Coalyard Remote Sub-station and consisting of electrolytic copper bus bar connection, Bus bar Chamber, Cable Chamber and fabricated with 14SWG CRCA sheet with 9 tank pre- treatment and powder coating as per specification along with interconnecting suitable bus bars, CT, Numerical Relay, Digital Multifunction Meter suitable for communication over RS 485 port and consisting of Switchgears (attached to the tender) to be supplied as per specification. Any item required for successful design & working of the panels as per intended use shall be considered at bidders end without any cost implications post bidding stage. The panel design & feeder arrangment shall follow the enclosed SLD groupings for ease of isolation of essential & non essential feeders as per operational needs. Since there is a strict restriction on the available space for panel installation, bidders are recommended to visit the site for understanding actual requirements for successful installation of the panel board being supplied. It shall be bidders responsibility to study the site requirements and take into account all required items for successfull design, supply, erection & commissioning of the panels Any claims whatsoever shall not be entertained under any circumstances post bid submission. Switchgear details, SLD and Specification of LT Panel attached. The Panel to be installed at a height of 30 cm from the existing floor level.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail