Armo Of Internal And External Electrical Installations At Aai Transit Guest House And Aai Kendriya Vidyalaya , Rangpuri , New Delhi ( 2021-23 ) , Rangpuri, New Delhi-Delhi

Airports Authority Of India has published Armo Of Internal And External Electrical Installations At Aai Transit Guest House And Aai Kendriya Vidyalaya , Rangpuri , New Delhi ( 2021-23 ) . Submission Date for this Tender is 01-05-2021. Coats and Jackets Tenders in Rangpuri, New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

27715807
Armo Of Internal And External Electrical Installations At Aai Transit Guest House And Aai Kendriya Vidyalaya , Rangpuri , New Delhi ( 2021-23 )
Open Tender
Indian
Delhi
Rangpuri, New Delhi
01-05-2021

Tender Details

Armo Of Internal And External Electrical Installations At Aai Transit Guest House And Aai Kendriya Vidyalaya , Rangpuri , New Delhi ( 2021-23 ) , Sh-I: Operation & Maintenance Operation & Maintenance Of Internal & External Electrical Installations I / C Fire Fighting System , Operation Of Dg Set And Pumping Set At Aai Transit Guest House , Aai Kendriya Vidyalaya And Paper Recycling Unit ( Excluding Factory Machinerey ) . The Deputing Staffs Shall Note Down The Compaint In Complaint Register And Attend The Complaint For Immediate Follow Up Action By Arranging The Store Material . The Following Minimum Manpower Shall Be Provided By Agency On All Working Days I / C Sunday & Holidays And Releiver Shall Be Provided On Weekly-Off . A ) Operator Cum Wireman - 03 Nos . ( 1 No . Each In Three Shifts Per Day ) ; B ) Khallasi - 03 Nos . ( 1 No . Each In Three Shifts Per Day ) , Fuel Cost For Running Of The Following Capacity Kirloskar Make Dg Set Per Hour Basis ( Contractor Has To Quote Their Rate For Running Hours I / C Handling , Storing And Transportation Cost Of Fuel , The Rate Shall Be Assessed According To The Location And Capacity Of Dg Set Mentioned Below As Per Special Conditions Of The Tender . , 1X125 Kva , 1X62 . 5 Kva , 1X10 Kva , Sh-Ii: Supply Of Electrical Spares & Accessories Supply Of Flame Retardant Pvc Insulated Single Core Copper Conductor ( Flexible ) Cable Suitable Upto 1100V Grade Conforming To Is:694 / 1990 With Latest Amendments Of Aai Approved Make Of Following Size: , 1 X 1 . 5 Sqmm ( 90 Mtr Coil ) , 1 X 2 . 5 Sqmm ( 90 Mtr Coil ) , 1 X 4 . 0 Sqmm ( 90 Mtr Coil ) , Supply Of Pvc Insulated & Pvc Round Sheathed Copper Conductor ( Flexible ) Industrial Cable ( Multicore ) , 1100V Conforming To Is:694 / 1990 With Latest Amendments Of Aai Approved Make Of Following Size: , 3 X 1 . 5 Sqmm ( 100 Mtr Coil ) , 3 X 2 . 5 Sqmm ( 100 Mtr Coil ) , 3 X 4 . 0 Sqmm ( 100 Mtr Coil ) , Supply Of Following Size Xlpe Insulated Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1 . 1Kv Grade Conforming To Is:1554 ( Part-I ) With Upto Date Amendment Complete As Required . , 4 X 16 Sq . Mm . , 4 X 25 Sq . Mm . , Supplying Of Following Size Of Pvc Casing And Capping As Per Aai Approved Make List As Required . , 20Mm X 12Mm , 25Mm X 16Mm , 6-32 A , 10 Ka , Sp Mcb , C Series , 6-32 A , 10 Ka , Dp Mcb , C Series , 6-32 A , 10 Ka , Tpn Mcb , C Series , Isolator 100Amp ( Fp ) , Industrial Plug & Socket Box With Metal Cover - 20 A With 20 A Spn Mcb , C- Series , Supply Of Following Rating And Breaking Capacity Mccbs :- , 250A , 36Ka , Fp Mccb , 250A , 36Ka , Tp Mccb , 125A , 25Ka , Tp Mccb , 100A , 25Ka , Tp Mccb , 32-63A , 25Ka , Tp Mccb , 3 Pin Top 6 Amp , 3 Pin Top 16 Amp , Piano Type 5 / 6 Amp Switch , Piano Type 3 Pin 5 / 6 Amp Socket Outlet , Piano Type 16 / 20 Amp Switch , 20 & 10 Amp , Uni Socket Outlet , 20 & 10 Amp Switch Socket Combined With Box , Pvc Tape , Electronic Fan Regulator ( Step Type ) , Capacitor 2 . 0 Mfd / 2 . 5 Mfd , Capacitor 4Mfd , Ceiling Fan ( 1200 Mm Sweep ) , Wall Mounting Fan ( 400 Mm Sweep ) , 9 Watt Led Bulb ( B22 ) , 15 Watt Led Bulb ( B22 ) , 18 / 20 Watt Extruded Aluminium Retrofit Led Tubelight , Supply Of Lead Acid Batteries 12V , 150Ah Capacity In Charged Condition , As & When Required . , Supply Of Desert Coolers Made Of Gi Sheet Body Of 20 Gauge Of Dimension 5Ftx2ftx3ft With Fan And Pump And All Accessories Complete As Required . , Supply Of Desert Coolers Made Of Gi Sheet Body Of 20 Gauge Of Dimension 2Ftx2ftx3ft With Fan And Pump And All Accessories Complete As Required . , Supply Of Cooler Pads Suitable For Standard Size Desert Cooler As Per Site Requirement , Supply Of Desert Cooler Pump Of Isi Marked Suitable For 220V Ac Supply . , Refilling Of Water Type Fire Extinguishers Of 9 Ltr . Capacity , Etc . As Required . , Refilling Of Co2 Type , 4 . 5 Kg Fire Extinguishers As Required . , Sh-Iii: Painting Works Painting Of Fire Fighting Pipe Line After Scrapping With Emery / Sand Paper To Get A Smooth Surface And Painting With One Coat Of Primer And Two Or More Coat Synthetic Enamel Paint Of Approval Brand And Manufacture To Give An Even Shade Complete As Required . , Painting Of 100 Mm Dia Pipe Only , Painting Of 80 Mm Dia Pipe To 65 Mm Dia Pipe Only . , Painting Of 25 Mm Dia Pipe . , Painting Of First - Aid Hose Reel Drum Including Accessories With Pipes Etc . Complete After Scrapping With Emery / Sand Paper To Get A Smooth Surgace And Painting With Two Or Maore Coat Or Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Complete As Required . , Painting Of Desert Cooler As Per Site Requirement . , Painting Of Distribution Boards / Out Door Panel Etc . In Installed Position With Synthetic Enamelled Paint By Spray / Brush Painting By One Or More Coats I / C Scrapping , Cleaning Of Surface & Writing Actual Nomenclature With Highlighted Colour On The Installation After Painting , Etc . Complete As Required . , Sh-Iv: Rewinding & Repairing Of Submersible Pumps Rewinding Of Following Pump Motors Etc . As & When Required With Super Enemelled Copper Winding Wire , Varnishing Including Greasing Replacement Of Bearings / Bush , Thrust Support Plate , Repairing / Replace Of Shaft Including Transporatation Charges Completed As Required . ( Dismantle Material Belongs To The Contractor ) , 12 . 5 Hp , 3 Phase Water Pump ( Fire System ) , 5 . 0 Hp , 3 Phase Submersible Pump , 1 . 5 Hp , 3 Phase Mono Submersible Pump , 5 . 0 Hp , 3 Phase Booster Pump , 1-1 . 5 Hp , Single Phase Water Pump , Rewinding Of Following As Per Original Characteristics With Super Enameled Copper Wire And E Class Insulation Material Repairing / Replacing The Worn Out Bearing Etc . Complete As Required . , Ceiling Fan As & When Required . , Exhaust Fan Upto 450Mm As & When Required . , Lifting & Lowering Charges Of Mono Submersible Pump Set Upto Required Depth Of Underground Tank I / C Water Proof Cable Jointing Including Transportation Of Special Tools And Plants Etc . As Reqd . , Charges For Lifting & Lowerig Of Submersible Pump Set Alongwith Pipe Lines , Cable From Existing Bore , As & When Required I / C Cost Of Labour , Tools & Plants , Waterproof Cable Jointing & Minor Items Such As Nut-Bolt , Rubber Packing , Etc . As Required . , Sh-V: Dsr Items Execution Of Works As Per Requirement Of Site From Cpwd Schedule Of Rates ( Electrical Dsr-2018 ) As Per Cpwd Specifications Complete As Required ( Total Amount Of Rs . 50000 . 00 ( Exclusive Of Gst ) Is Kept For Dsr Items-2018 ) [ ( Note- Rate Of Dsr Items Shall Be Quoted Against Total Amount Of Rs 50000 . 00 ( Fifty Thousand ) In Figures Excluding Gst Which Shall Be Converted In The Percentage ( Above / Below ) And Rate Of Dsr Items Shall Be Taken Exclusive Of Gst ( Basic Rate ) On Which Payment Shall Be Made Considering Percentage Above / Below Rate Quoted Against Rs . 50000 . 00 ]

Key Value

Document Fees
INR 1180 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: ARMO of Internal & External Electrical Installations at AAI Transit Guest House & AAI Kendriya Vidyalaya, Rangpuri, New Delhi (2021-23).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SH-I: OPERATION & MAINTENANCE\n Operation & maintenance of internal & external electrical installations i/c Fire Fighting System, Operation of DG Set and pumping set at AAI Transit Guest House, AAI Kendriya Vidyalaya and Paper Recycling Unit (excluding Factory Machinerey). The deputing staffs shall note down the compaint in complaint register and attend the complaint for immediate follow up action by arranging the store material. The following minimum manpower shall be provided by agency on all working days i/c Sunday & holidays and releiver shall be provided on weekly-off.\na) Operator cum Wireman - 03 Nos. (1 No. each in three shifts per day);\nb) Khallasi - 03 Nos. (1 No. each in three shifts per day) 1 24 Months
2 2 Fuel cost for running of the following capacity Kirloskar make DG set per hour basis (contractor has to quote their rate for running hours i/c handling, storing and transportation cost of fuel, the Rate shall be assessed according to the location and capacity of DG set mentioned below as per special conditions of the tender. 2
3 2.01 1x125 KVA 3 130 P. Hrs
4 2.02 1x62.5 KVA 4 100 P. Hrs
5 2.03 1x10 KVA 5 40 P. Hrs
6 3 SH-II: SUPPLY OF ELECTRICAL SPARES & ACCESSORIES\nSupply of Flame Retardant PVC insulated single core copper conductor (flexible) cable suitable upto 1100V grade conforming to IS:694/1990 with latest amendments of AAI approved make of following size: 6
7 3.01 1 x 1.5 sqmm (90 mtr Coil) 7 4 Nos.
8 3.02 1 x 2.5 sqmm (90 mtr Coil) 8 2 Nos.
9 3.03 1 x 4.0 sqmm (90 mtr Coil) 9 1 Nos.
10 4 Supply of PVC insulated & PVC round sheathed copper conductor (flexible) industrial cable (multicore), 1100V conforming to IS:694/1990 with latest amendments of AAI approved make of following size: 10
11 4.01 3 x 1.5 sqmm (100 mtr Coil) 11 1 Nos.
12 4.02 3 x 2.5 sqmm (100 mtr Coil) 12 1 Nos.
13 4.03 3 x 4.0 sqmm (100 mtr Coil) 13 1 Nos.
14 5 Supply of following size XLPE insulated PVC sheathed aluminium conductor armoured power cable of 1.1KV grade conforming to IS:1554 (part-I) with upto date amendment complete as required. 14
15 5.01 4 x 16 sq.mm. 15 100 Mtrs.
16 5.02 4 x 25 sq.mm. 16 100 Mtrs.
17 6 Supplying of following size of PVC casing and capping as per AAI approved make list as required. 17
18 6.01 20mm x 12mm 18 50 Mtrs.
19 6.02 25mm x 16mm 19 30 Mtrs.
20 7 6-32 A, 10 KA, SP MCB, C Series 20 25 Nos
21 8 6-32 A, 10 KA, DP MCB, C Series 21 5 Nos
22 9 6-32 A, 10 KA, TPN MCB, C Series 22 5 Nos
23 10 Isolator 100Amp (FP) 23 3 Nos
24 11 Industrial Plug & Socket Box with metal cover - 20 A with 20 A SPN MCB, C- series 24 4 Nos
25 12 Supply of following rating and breaking capacity MCCB's :- 25
26 12.01 250A, 36kA, FP MCCB 26 1 Nos
27 12.02 250A, 36kA, TP MCCB 27 1 Nos
28 12.03 125A, 25kA, TP MCCB 28 2 Nos
29 12.04 100A, 25kA, TP MCCB 29 2 Nos
30 12.05 32-63A, 25kA, TP MCCB 30 3 Nos
31 13 3 Pin top 6 Amp 31 20 Nos
32 14 3 Pin top 16 Amp 32 20 Nos
33 15 Piano type 5/6 Amp Switch 33 120 Nos
34 16 Piano type 3 pin 5/6 Amp Socket outlet 34 40 Nos
35 17 Piano type 16/20 Amp Switch 35 25 Nos
36 18 20 & 10 Amp, Uni Socket outlet 36 25 Nos
37 19 20 & 10 Amp Switch Socket combined with box 37 15 Nos
38 20 PVC Tape 38 75 Nos
39 21 Electronic Fan Regulator (Step Type) 39 20 Nos
40 22 Capacitor 2.0 MFD/2.5 MFD 40 75 Nos
41 23 Capacitor 4MFD 41 5 Nos
42 24 Ceiling fan (1200 mm sweep) 42 10 Nos
43 25 Wall mounting fan (400 mm sweep) 43 5 Nos
44 26 9 watt LED bulb (B22) 44 15 Nos
45 27 15 Watt LED bulb (B22) 45 15 Nos
46 28 18/20 watt Extruded Aluminium Retrofit LED Tubelight 46 20 Nos
47 29 Supply of lead Acid Batteries 12V, 150AH capacity in charged condition, as & when required. 47 2 Nos
48 30 Supply of Desert Coolers made of GI sheet body of 20 Gauge of dimension 5ftX2ftX3ft with fan and pump and all accessories complete as required. 48 1 Each
49 31 Supply of Desert Coolers made of GI sheet body of 20 Gauge of dimension 2ftX2ftX3ft with fan and pump and all accessories complete as required. 49 4 Each
50 32 Supply of cooler pads suitable for standard size desert cooler as per site requirement 50 15 Each
51 33 Supply of desert cooler pump of ISI marked suitable for 220V AC supply. 51 4 Each
52 34 Refilling of Water type fire extinguishers of 9 ltr. capacity, etc. as required. 52 10 Nos
53 35 Refilling of CO2 type, 4.5 Kg fire extinguishers as required. 53 10 Nos
54 36 SH-III: PAINTING WORKS\nPainting of fire fighting pipe line after scrapping with emery/sand paper to get a smooth surface and painting with one coat of primer and Two or more coat synthetic enamel paint of approval brand and manufacture to give an even shade complete as required. 54
55 36.01 Painting of 100 mm dia pipe only 55 150 Mtrs.
56 36.02 Painting of 80 mm dia pipe to 65 mm dia pipe only. 56 50 Mtrs.
57 36.03 Painting of 25 mm dia pipe. 57 50 Mtrs.
58 37 Painting of First - Aid Hose Reel Drum including accessories with pipes etc. complete after scrapping with emery/sand paper to get a smooth surgace and painting with Two or maore coat or synthetic enamel paint of approved brand and manufacture to give an even shade complete as required. 58 5 Job
59 38 Painting of Desert Cooler as per site requirement. 59 5 Job
60 39 Painting of Distribution boards/out door panel etc. in installed position with synthetic enamelled paint by spray/brush painting by one or more coats i/c scrapping, cleaning of surface & writing actual nomenclature with highlighted colour on the installation after painting, etc. complete as required. 60 20 sqmtr.
61 40 SH-IV: REWINDING & REPAIRING OF SUBMERSIBLE PUMPS\nRewinding of following pump motors etc. as & when required with super enemelled copper winding wire, varnishing including greasing replacement of bearings/Bush, thrust support plate, repairing /replace of shaft including transporatation charges completed as required. (Dismantle material belongs to the contractor) 61
62 40.01 12.5 HP, 3 Phase water pump (Fire System) 62 2 Job
63 40.02 5.0 HP, 3 phase Submersible pump 63 3 Job
64 40.03 1.5 HP, 3 phase Mono Submersible pump 64 2 Job
65 40.04 5.0 HP, 3 phase booster pump 65 2 Job
66 40.05 1-1.5 HP, Single phase water pump 66 4 Job
67 41 Rewinding of following as per original characteristics with super enameled copper wire and 'E' class insulation material repairing/replacing the worn out bearing etc. complete as required. 67
68 41.01 Ceiling Fan as & when required. 68 40 Job
69 41.02 Exhaust fan upto 450mm as & when required. 69 10 Job
70 42 Lifting & lowering charges of mono submersible pump set upto required depth of underground tank i/c water proof cable jointing including transportation of special tools and plants etc. as reqd. 70 2 Job
71 43 Charges for lifting & lowerig of submersible pump set alongwith pipe lines, cable from existing bore, as & when required i/c cost of labour, tools & plants, waterproof cable jointing & minor items such as nut-bolt, rubber packing, etc. as required. 71 3 Job
72 44 SH-V: DSR ITEMS\nExecution of works as per requirement of site from CPWD schedule of rates (Electrical DSR-2018) as per CPWD specifications complete as required (Total amount of Rs. 50000.00 (Exclusive of GST) is kept for DSR items-2018) [ (Note- Rate of DSR items shall be quoted against Total amount of Rs 50000.00 (Fifty Thousand) in figures excluding GST which shall be converted in the percentage (above/below) and rate of DSR items shall be taken exclusive of GST (basic rate) on which payment shall be made considering percentage above/below rate quoted against Rs. 50000.00] 72 1 Job