Military Engineer Services-MES has published Provn Of 24 Geysers For Type-Ii Accn Including Upgradation Of Electric Supply At Cqa ( I ) Estate Ladpur Raipur Dehradun Under Ge ( I ) ( P ) ( Fy ) Kanpur . . Submission Date for this Tender is 17-05-2021. Geyser Tenders in GE (I) (P) FY KANPUR Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-May-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-05-2021 |
Name of Work: Provn of 24 Geysers for Type-II accn including upgradation of electric supply at CQA (I) Estate Ladpur Raipur Dehradun under GE (I) (P) (FY) Kanpur. | |||||
---|---|---|---|---|---|
Sl. No. | Description of item | Item Code / Make | Quantity | Unit | |
1 | 1 | Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 4 star and above rated complete all including 04 Nos. 'T' bolt and PCC and making good to the surface complete all as directed for of make: Crompton (Amica) / Bajaj (New Shakti) / AO Smith (HSE-VAS-X-025) | 24 | Each | |
2 | 2 | Supply and fix 304 grade stainless steel connection pipe (02 piece set) 15mm bore 600mm long having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed. (Make : Prayag / AO Smith / Havells) . | 24 | Each set | |
3 | 3 | S & L Tubes, `Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors of size 15 mm bore. Make ISI marked of approved make. (Jindal / Tata / Surya Prakash) | 60 | RM | |
4 | 4 | M&L for cutting existing steel tubing for alterations or additions for tube size 20 mm bore. | 24 | Each | |
5 | 5 | S & F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed of size 15 mm bore. Make: Cera / Hindware / Parry ware | 24 | Each | |
6 | 6 | S & F stop cock, PTMT any colour high pressure screwed for iron pipe and fixed for size 15 mm dia pipe. Make ISI marked of approved make. Zolota / Neta / Ajanta / Anchor | 48 | Each | |
7 | 7 | S&F bib cock long body with flange , fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. make. Zolota / Neta / Ajanta / Anchor | 24 | Each | |
8 | 8 | M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6.0 Sqmm as earth continuity conductor all as specified and directed. Make of wire: Finolex / Havells / Polycab Note :- (1) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (2) The cutting chases for conduits and making good to wall, floors etc to be included under the unit rate quoted by the contractor for this item. | 120 | RM | |
9 | 9 | M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit with standard accessories, along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor all as specified and directed. Make of wire: Finolex / Havells / Polycab Note :- (1) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (2) The cutting chases for conduits and making good to wall, floors etc to be included under the unit rate quoted by the contractor for this item. | 160 | RM | |
10 | 10 | Supply and installed Industrial plug socket with plug top, enclosure single Phase 240 Volts, 50 Hz including MCB SP 20 Amps complete all as specified and directed. Make :ABB / Scheinder/ legrand. | 24 | Each | |
11 | 11 | Supply and fixing factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 63 Amps as incomer and 12 SP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified & directed. Make- ABB / Scheinder/ legrand. | 4 | Each | |
12 | 12 | Supplying and fixing on distribution board, MCCB four pole of 63 Amps, 415 volts, 50 Hz, AC made from adjustable thermel setting & fixed magnetic setting , 16 KA breaking capacity complete all as specified.Make- ABB / Scheinder/ legrand. | 4 | Each | |
13 | 13 | S&F MCB DB sheet enclosure single pole and neutral 240V with 200 Amp standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, double door type complete with out MCB and with enclosure suitable for 4 way complete all as specified and directed. Make- ABB / Scheinder/ legrand. | 24 | Each | |
14 | 14 | Supplying and fixing on distribution board, SPN MCB of 32 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity complete all as specified. Make- Strandard or equivalent Make- ABB / Scheinder/ legrand. | 24 | Each | |
15 | 15 | Supplying and fixing on distribution board, single pole (SP) MCB/Isolator 10/ 16/ 20 /25 /32/ Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity complete all as specified. Make : Make- ABB / Scheinder/ legrand. | 48 | Each | |
16 | 16 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core. Make of cable: Havells / Finolex / Gloster | 300 | RM | |
17 | 17 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core. Make of cable: Havells / Finolex / Gloster | 150 | RM | |
18 | 18 | Excavation in trenches in soft/loose soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre wide and getting out including forming bottom surface & sides to required slope/size, complete all as specified and directed. | 68 | Cum | |
19 | 19 | Removal of surplus excavated spoil not exceeding 50 metre distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. | 30 | Cum | |
20 | 20 | Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed. | 35 | Cum | |
21 | 21 | Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. | 20 | Cum | |
22 | 22 | Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable complete all as specified and directed. | 2100 | Each | |
23 | 23 | M&L for Cement concrete type D-2, 1:4:8 (40mm graded aggregate) upto 100 mm thick for making good road cutting complete all as directed | 15 | Sqm | |
24 | 24 | Supply and lay pipe galvanized, “light grade”, including fittings of nominal dia 50mm Make ISI marked of approved make. (Jindal / Tata / Surya Prakash | 18 | RM | |
25 | 25 | Supply and lay pipe galvanized, 'Medium grade' including fittings of nominal dia 50mm Make ISI marked of approved make. (Jindal / Tata / Surya Prakash | 15 | RM | |
26 | 26 | Supply and lay pipe galvanized, “Medium grade”, including fittings of nominal dia 40mm Make ISI marked of approved make. (Jindal / Tata / Surya Prakash | 15 | RM | |
27 | 27 | Supply and lay pipe galvanized, “Medium grade”, including fittings of nominal dia 25mm Make ISI marked of approved make. (Jindal / Tata / Surya Prakash | 36 | RM | |
28 | 28 | Supplying, installing, testing and commissioing of outdoor type LT panel (Confirming to IS-8623) AC 415V, 50Hz 3 phase 4 wire made out of 3.15 mm thick CRCA sheet steel CPRI approved (certificate to be furnished before approval) with powder coated finish index of protection not less than IP 43, floor mounted front operated cubicalconsisting of bus bar chamber for phase and neutral, PVC sleeves of phase and neutral indication, interconnection with solid conductor/strips/wires/cables with PVC tapes/sleeves of RYB colours, including suitable adopter boxes with spreader links for connecting cables of switch terminals, locking arrangement complete for following switch gears:- \n(a) MCCB 250 Amps 4 pole 415V, AC supply having breaking capacity Icu=35/36KA with adjustable thermal & magnetic setting of make Schneider/Legrand/ABB Qty -01 No. (Incoming) \n(b) MCCB 63 Amps 4 pole 415V, AC supply having breaking capacity Icu=25KA with adjustable thermal & magnetic setting of make Schneider/Legrand/ABB Qty -05 No. (outgoing)\n(c) Indicating lamp for three phase - Qty 01 set of 3 Nos (Make- L&T/BCH/Rishab).\n(d) Aluminium bus bar rating 400 Amps\n\n | 1 | Each | |
29 | 29 | M&L earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate no 5 connected to earthing test point all as specified or incl testing on completion. | 4 | Each | |
30 | 30 | M&L earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized earth strip size of 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate no 5 connected to earthing test point all as specified or incl testing on completion. | 2 | Each | |
31 | 31 | M&L for earth continuity conductor fixed to wall or burried in ground or drawn in conduit / pipe suitable for loop earthing etc as required 4.0 sqmm GI earth wire all as specified and directed. | 60 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail