Chemicals and Fertilizers Boards / Undertakings / PSU Closing in 0 days TDR #27701830

Spx/2020/06 Procurement Of Duel Redundant Power Supply Unit

Issued by Boards / Undertakings / PSU · NFL Nangal Unit, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 May 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Auction
Location / State
NFL Nangal Unit → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Spx/2020/06 Procurement Of Duel Redundant Power Supply Unit , Duel Redundant Power Supply Unit Along With Quint Diode , Input Voltage :100 To 240 VacOutput Voltage : 24 Vdc Output Current : Minimum 4 Amp . Operating Temp . : 0 To 50 Deg . C Mounting : Din RailNote: Each Set Consist Of 2 Nos Of 24 Vdc/4A Power Supply Units Connected In Parallel And 01 Number Of Quint Diode / Diode Or-Ing ( One Set = 3 No . Qty . Total Requirement = 03 Sets , Signal Multiplier Cum Transmitter Powering UnitPower Supply : 24Vdc , Mounting: Din Rail , In Control Room Safe AreaInput: 4-20 Ma From 2 Wire Field TransmitterField Transmitter Power : 24 V DcOutput:4-20 Ma ( 2 Nos ) Isolation Required Between Input , Out Put And Power SupplyA Signal Dulicator With Isolation Should Provide To Cater To Both Existing Instrumentation And Also To Telemetry Without Compromising On The Drop In Signal Due To Loading . Quantity= 20 Nos . , Trip Switch Power Supply : 24 V DcInput : 4-20 Ma From Field Transmitter Output : 2 Independent Contact Ouput Programmable High/Low AlarmLed Indicator : Required For Each Out Put When Relay Activated . Mounting : Din Rail Installation In Control RoomAmbient Temp . : Up To 50 Deg C Quantity= 10 Nos .

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Apr-2021 Extension in TOD Date 03-May-2021

BOQ

Name of Work: DUEL REDUNDANT POWER SUPPLY UNIT /SIGNAL MULTIPLIER & TRIP SWITCH
Sl.No.Item DescriptionMaterial Code No.QuantityUnits
11.01DUEL REDUNDANT POWER SUPPLY UNIT ALONG WITH QUINT DIODE,\nINPUT VOLTAGE :100 TO 240 VAC\nOUTPUT VOLTAGE : 24 VDC \nOUTPUT CURRENT : MINIMUM 4 Amp.\nOPERATING TEMP. : 0 TO 50 Deg. C \nMOUNTING : DIN RAIL\n\nNOTE: EACH SET CONSIST OF 2 No's OF 24 VDC/4A POWER SUPPLY UNITS CONNECTED IN PARALLEL AND 01 NUMBER OF QUINT DIODE / DIODE OR-ING \n\n (ONE SET = 3 No. Qty. Total Requirement = 03 Sets\n\n\n3SET
21.02SIGNAL MULTIPLIER CUM TRANSMITTER POWERING UNIT\nPOWER SUPPLY : 24VDC, \nMOUNTING: DIN RAIL, In Control Room Safe area\nINPUT: 4-20 mA FROM 2 wire field transmitter\nFIELD Transmitter Power : 24 V DC\nOUTPUT:4-20 mA (2 No's)\nIsolation required between input,out put and Power supply\n\nA signal dulicator with isolation should provide to cater to both existing instrumentation and also to telemetry without compromising on the drop in signal due to loading.\n \n QUANTITY= 20 Nos.\n20NO.
31.03TRIP SWITCH\n Power Supply : 24 V DC\nInput : 4-20 mA from field Transmitter \nOUTPUT : 2 INDEPENDENT CONTACT OUPUT PROGRAMMABLE HIGH/LOW ALARM\nLED Indicator : Required for each out put when relay activated.\nMounting : DIN Rail \nInstallation In Control Room\nAmbient Temp. : Up to 50 Deg C\n\n QUANTITY= 10 Nos.\n10NO.

AI Tender Summary

OUR REF NO 27701830
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 03-05-2021
Authority
Authority Name National Fertilizers Limited
Work Description Spx/2020/06 Procurement Of Duel Redundant Power Supply Unit , Duel Redundant Power Supply Unit Along With Quint Diode , Input Voltage :100 To 240 VacOutput Voltage : 24 Vdc Output Current : Minimum 4 Amp . Operating Temp . : 0 To 50 Deg . C Mounting : Din RailNote: Each Set Consist Of 2 Nos Of 24 Vdc/4A Power Supply Units Connected In Parallel And 01 Number Of Quint Diode / Diode Or-Ing ( One Set = 3 No . Qty . Total Requirement = 03 Sets , Signal Multiplier Cum Transmitter Powering UnitPower Supply : 24Vdc , Mounting: Din Rail , In Control Room Safe AreaInput: 4-20 Ma From 2 Wire Field TransmitterField Transmitter Power : 24 V DcOutput:4-20 Ma ( 2 Nos ) Isolation Required Between Input , Out Put And Power SupplyA Signal Dulicator With Isolation Should Provide To Cater To Both Existing Instrumentation And Also To Telemetry Without Compromising On The Drop In Signal Due To Loading . Quantity= 20 Nos . , Trip Switch Power Supply : 24 V DcInput : 4-20 Ma From Field Transmitter Output : 2 Independent Contact Ouput Programmable High/Low AlarmLed Indicator : Required For Each Out Put When Relay Activated . Mounting : Din Rail Installation In Control RoomAmbient Temp . : Up To 50 Deg C Quantity= 10 Nos .
Basic Detail
Tender No spx/2021/06
Bidding Type Auction
Location
City NFL Nangal Unit
State Punjab
Key Dates
Publish Date 30 Apr 2021
Submission Date 03 May 2021
Open Date 04 May 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
NITSPX202106PSU.pdf
TECHNICALBID.xls
Tendernotice_1.pdf
F4D1ADFB-B1E3-4560-9A71-24934F844118.html
BOQ_82254.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 30, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
May 03, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 03, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 04, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

NITSPX202106PSU.pdf

xls

TECHNICALBID.xls

pdf

Tendernotice_1.pdf

html

F4D1ADFB-B1E3-4560-9A71-24934F844118.html

xls

BOQ_82254.xls

TenderDetail
Loading tenders