}

Tender For Supply Of Essential Medicines For Civil Surgeon Store Yavatmal , Inj. Lignocaine Orlidocaine Or Xylocaine Hcl 0.02 ( 2% ) 30 Ml , Inj. Xylocaine Or Lignocaine Or Lidocaine 5% Heavy Dextrose 75Mg / Ml, Lignocaine Hci 53.3Mg / Ml , Lignoca, YAVATMAL-Maharashtra

Directorate Of Health Services-DOHS has published Tender For Supply Of Essential Medicines For Civil Surgeon Store Yavatmal , Inj. Lignocaine Orlidocaine Or Xylocaine Hcl 0.02 ( 2% ) 30 Ml , Inj. Xylocaine Or Lignocaine Or Lidocaine 5% Heavy Dextrose 75Mg / Ml, Lignocaine Hci 53.3Mg / Ml , Lignoca. Submission Date for this Tender is 24-04-2021. Medicine Tenders in YAVATMAL Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

27690056
Tender For Supply Of Essential Medicines For Civil Surgeon Store Yavatmal , Inj. Lignocaine Orlidocaine Or Xylocaine Hcl 0.02 ( 2% ) 30 Ml , Inj. Xylocaine Or Lignocaine Or Lidocaine 5% Heavy Dextrose 75Mg / Ml, Lignocaine Hci 53.3Mg / Ml , Lignoca
Open Tender
Indian
Maharashtra
YAVATMAL
24-04-2021

Tender Details

Tender For Supply Of Essential Medicines For Civil Surgeon Store Yavatmal , Inj. Lignocaine Orlidocaine Or Xylocaine Hcl 0.02 ( 2% ) 30 Ml , Inj. Xylocaine Or Lignocaine Or Lidocaine 5% Heavy Dextrose 75Mg / Ml, Lignocaine Hci 53.3Mg / Ml , Lignocaine Or Lidocaine Or Xylocainehcl 20Mg, Adrenaline Or Epinephrine 5Mcg, Per Ml ) 30Ml Inj , Inj. Neostigmine Each Ml Of The 1:2000 Concentration Contains Neostigmine Methylsulfate 0.5 Mg, Methylparaben 1.8 Mg And Propylparaben 0.2 Mg ( Used As Preservatives ) , In Water For Injection Q.S.Ph ( Range 5.0 - 6.5 ) Adjusted, When Necessary, With Sodium Hydroxide - 1 Ml Usp , Tab. Diazepam 5 Mg , Inj. Diazepam5 Mg / Ml - 2 Ml , Inj. Ranitidine Hcl 25 Mg / Ml - 2 Ml Ampoule Each 1 Ml Of Aqueous Solution Contains Ranitidine 25 Mg ( As The Hydrochloride ) ; Phenol 5 Mg As Preservative; And 0.96 Mg Of Monobasic Potassium Phosphate And 2.4 Mg Of Dibasic Sodium Phosphate As Buffers. , Tab. Ranitidine Hydrochloride 150 Mg Aluminium Blister - Strip Of 10 Tablets , Sy. Antacid Each 5 Ml Contains Aluminium Hydroxide 250 Mg + Magnesium Hydroxide 250 Mg + Dimethicone 50 Mg , Cap.Omperazole 20 Mg Aluminium Blister - Strip Of 10 Capsule , Cap.Omperazole 40 Mg Aluminium Blister - Strip Of 10 Capsule , Inj. Pantaprazole 40 Mg / 10 Ml , Pantoprazole Tab. 40Mg , Tab Domperidone 10 Mg M D Aluminium Blister - Strip Of 10 Tablets , Syrup Domperidone Sy. Domperidone 1 Mg / Ml - Bottle Of 30 Ml , Tab. Ondansetron 4 Mg , Inj. Ondansetron Hydrochloride Premixed 2 Mg / Ml - 2 Ml Ampoule Each 1 Ml Of Aqueous Solution In The 2-Ml Single-Dose Vial Contains 2 Mg Of Ondansetron As The Hydrochloride Dihydrate; 9.0 Mg Of Sodium Chloride, And 0.5 Mg Of Citric Acid Monohydrate, And 0.25 Mg Of Sodium Citrate Dihydrate, As Buffers In Water For Injection, , Ondansetron 2Mg / 5Ml , Inj. Promethazine Hydrochloride 25 Mg / Ml Im / Iv Each Ml Contains Either 25 Mg Promethazine Hydrochloride With 0.1 Mg Edetate Disodium, 0.04 Mg Calcium Chloride, 0.25 Mg Sodium Metabisulfite, And 5 Mg Phenol In Water For Injection.- 2 Ml Ampoulesi. M. / I. V , Metoclopramide Hcl 10 Mg , Metoclopramide Hcl 5 Mg / Ml , O R S Who Formula – O R S Powder 20.5 Gm As Per Who Formula Contains G / L : Sodium Chloride Ip 2.60 Gm, Potasium Chloride Ip 1.50 Gm, Sodium Citrate Ip 2.90 Gm , Anhydrous Dextrose Ip 13.50 Gm The Total Osmolar Concentration Of The Solution In Terms Of Mosmol Per Litre Is 245 , Zinc Sulphate Or Gluconate Syrup : Each 5 Ml Of Syrup Contains Zinc Sulphate Or Gliuconateequivalent To Elemental Zinc 20Mg. , Tab. Zinc Sulphate 20 Mg Each Dispersible Tablet Contains Zinc Sulphate ( As Monohydrate ) 54.88Mg Equivalent To Elemental Zinc 20Mg. , Tab. Cetrizine Di Hydrochloride 10 Mgaluminium Blister - Strip Of 10 Tablets , Cetrizine Syrup 5 Mg / 5 Ml , Tab. Chlorpheneramine Maleate 4 Mgaluminium Blister - Strip Of 10 Tablets , Inj. Paracetamol 150 Mg / Ml - 2 Ml , Tab Paracetamol 500Mg , Paracetamol 150Mg / Ml , Sy. Paracetamol250 Mg / 5 Ml 60 Ml , Inj. Diclofenac Sodium 25 Mg / Ml - 3 Ml Amp , Tab. Diclofenac Sodium50 Mg Aluminium Blister - Strip Of 10 Tablets , Geldiclofenac Diethylammonium Salt 1.16 %W / W / 2.32% W / W ( Equivalent To Diclofenac Sod 1% W / W ) -30 Gm , Tab. Ibuprofen400mg F / C Aluminium Blister - Strip Of 10 Tablets , Ibuprofen 100Mg / 5Ml , Inj. Trammadol 50 Mg / Ml - 2 Ml Ampoule , Inj. Pentazocin Lactate 30 Mg / Ml - 1 Ml Ampoule , Tab. Amoxycillin D T 125 Mg , Cap. Amoxycillin Trihydrate 250 Mg , Cap. Amoxycillin Trihydrate 500 Mg , Sy. Amoxycillin Trihydrate 125 Mg / 5 Ml- Bottle Of 60 Ml , Sy. Amoxicillin 200 Mg + Clavulinic Acid 28.5 Mg / 5 Ml Dry Syrup - Bottle Of 40 Ml , Tab. Amoxycillin I P 500 Mg + Clavulanic Acid I P 125 Mg - Strip Of 6 Tablets , Tab. Amoxycillin250 Mg + Clav 125 Mg , Inj. Amoxycillin + Clavunic Acid 600 Mg Inj. Amoxycillin Sodium 500Mg + Clavuanic Acid As Potasium Salt 100 Mg I.E.600 Mg ( 0.6 Gm ) In Vial , Cefiximetab 200 Mg , Tab / Cap. Cephelexin 500 Mg , Inj. Ceftrixone500 Mg , Inj. Ceftrixone1000 Mg , Inj. Cefatoxime 250 Mg Nj. Cefotaxime Sodiumsterile Powder 250 Mg / Vial , Inj. Cefatoxime 500 Mg Nj. Cefotaxime Sodiumsterile Powder 500 Mg / Vial , Inj. Cefatoxime 1Gm Inj. Cefotaxime Sodiumsterile Powder 1 Gm / Vial , Inj. Meropenam 1 Gm -I.V. Vial Will Deliver 1 G Of Meropenem And 90.2 Mg Of Sodium As Sodium Carbonate ( 3.92 Meq ) , Inj. Meropenam 500 Mg Each 500 Mg Merrem I.V. Vial Will Deliver 500 Mg Meropenem And 45.1 Mg Of Sodium As Sodium Carbonate ( 1.96 Meq ) . , Cefpodoxime Proxetil Tab.100Mg , Cap. Doxycycline 100 Mg , Inj. Gentamycin 40 Mg / Ml - 2 Ml Amp / Vial , Inj. Amikacine Sulphate100 Mg - 2 Ml , Inj. Amikacine Sulphate250 Mg - 2 Ml , Inj. Amikacine Sulphate 500 Mg - 2 Ml , Tab. Ciprofloxacin 250 Mg , Tab. Ciprofloxacin 500 Mg , I. V. Ciprofloxacin: Each 100 Ml Contains :Ciprofloxacin Hcl Eq. To Ciprofloxacin 200 Mg , Water For Injection Q.S.Affs / Bfs / Ffs Technology , Tab. Azithromycin 250 Mg- Aluminium Blister - Strip Of 6 Tab , Tab. Azithromycin 500 Mgaluminium Blister - Strip Of 3 Tab , Sy. Azithromycin 200 Mg Per 5 Ml , Tab. Ofloxacillin 200 Mg Aluminium Blister - Strip Of 10 Tab , Tab. Metronidazole 200 Mg , Tab. Metronidazole 400 Mg , Metronidazole Syp 200Mg / 5Ml , I V.Metronidazole - 5Mg / Ml I. V. Metronidazole 500 Mg In 100 Ml Affs / Bfs / Ffs Technology , Tab. Norfloxacin 400 Mg Aluminium Blister - Strip Of 10 Tab , Tab. Tinidazole 300 Mg , Tab. Flucanazole 150 Mg , Cap. Itraconazole 100 Mg , Sy. Albendazole -200 Mg / 5 Ml Inbottle Of 10 Ml , Tab Ivermectin 12 Mg , Inj. Atropine Sulphate0.6 Mg / Ml - 1 Ml Amp , Tab. Amlodepin Besylate 2.5 Mg Aluminium Blister - Strip Of 10 Tablets , Tab. Amlodepin Besylate 5 Mg Aluminium Blister - Strip Of 10 Tablets , Tab. Atenolol 50 Mg Aluminium Blister - Strip Of 14 Tablets , Inj. Frusemide - 2 Ml Each 1 Ml Contains 10 Mg Furosemide , Tab. Atrovastatin 10 Mg , Tab Glibenclamide 5Mg + Metformin 500Mg , Tab. Metformin 500 Mg , Tab Glimepiride 2Mg , Inj. Etophyllin 169.4 Mg + Theophyllin 50.6 Mg In 2 Ml- 2 Ml , Levo Salbutamol Respiratory Solution 0.0625 Mg / Ml , Inj. Aminophyllin - 25 Mg Per Ml I.E. 250 Mg / 10 Ml W / V , Xylometazoline Nasal Drops 0.05% Per Ml , Cough Expectorant Diphenhydramine Hydrochloride 15 Mg ( Ip ) +Ammonium Chloride 150 Mg ( Ip ) + Sodium Citrate Ip - 60 Mg + Menthol -1 Mg ( Ip , Tab. Aspirin ( Acetylsalicylic Acid ) 75 Mg Aluminium Blister Of 14 Tablets , Low Molecular Weight Heparin ( Enoxaparin ) 0.6 Iu Pfs , Low Molecular Weight Heparin ( Enoxaparin ) 0.4 Iu Pfs , Tetanus Toxoid Dpap - Each 0.5 Ml Human Dose Contains:Tetanus Toxoid = Lf, Adsorbed On Aluminium Phosphate= 1.5 Mg ( Aipo4 ) Thiomersal 0.01% As Presevative ( Vaccine Fulfils The I.P. Requirement For Tetanus Toxoid ( Adsorbed ) , Lactulose Solution Contains Lactulose 667 Mg / Ml ( 10 G / 15 Ml ) . , Vitamin D3 ( Cholecalciferol ) 60, 000 Iu  / G , Inj. Iron Sucrose 50 Mg In 2.5Ml Ampoule , Anti D ( Rho-D ) Immunoglobulin ( Human ) Ultra Filered Or Nano Filtered 300Mcg / 1500 Iu In Pfs / Single Dose Vial , Inj. Magenesium Sulphate50 % W / V - 2 Mli.E. Each Ml Contain 500 Mg Magnesium Sulphate Per Ml , Inj. Oxytocin Each Ml. To Contain: Synthetic Oxytocin 5 Iu 1 Ml. Amp. , Inj Carboprost Tromethamine 250Mcg / Ml - 1 Ml , Inj Methyl Prednisolone Acetate 40Mg / Ml - 1 Ml Or2 Ml , Inj. Dexamethasone Sodium Phosphate 4 Mg / Ml - 2 Ml Vial Im / Iv - , I. V. Sodium Chloride ( Normal Saline ) 0.9% Isotonic ( Equivalent To Na+ 154 Mmol / L, Cl- 154 Mmol / L ) .W / V Affs / Bfs / Ffs Technology , I. V. Dextrose 5% Isotonic W / V Affs / Bfs / Ffs Technology , I.V. 25% Dextrose 100 Cc Affs Technology I. V. Dextrose 25% W / V - 100Ml Affs / Bfs / Ffs Technology , I. V. Dextrose 5% In Normal Saline 0.9% ( I. E. Glucose With Sodium Chloride5% Glucose, 0.9% Sodium Chloride ( Equivalent To 150 Mmol / L Na+ And 150 Mmol / L Cl- ) ; 5% Glucose, 0.45% Sodium Chloride ( Equivalent To 75 Mmol / L Na+ And 75 Mmol / L Cl-W / V ) Affs / Bfs / Ffs Technology , I. V. Ringers Lactate ( Sodium Lactate, Compound Solution ) Each 100Ml To Contain: Lactic Acid 0.24 Ml., Sod.Chl. 0.6 Gm, Potassium Chloride 0.04 Gm, Calcium Chloride 0.027 Gm. Water For Injection Q.S.Calculated Osmolarity –280 Mos / L ( Approx ) Concentration Of Electrolytes ( In Moles / Lit. ) - Sodium 131, Potassium 5, Calcium 2, Bicarbonate ( As Lactate ) 29, Chloride 111.Affs / Bfs / Ffs Technology , Sterile Water For Injection.5 Ml , Sterile Water For Injection.10 Ml , Inj. Sodabicarbonate 7.5 Mg / Ml ( 7.5% ) - 10 Ml Sodium Bicarbonate, Nonpyrogenic Solution Of Sodium Bicarbonate, In Water For Injection, It Contains No Antimicrobial Agent. Composition, Osmolarity, Ph And Ionic ( Nahco3 ) ( G / L ) Osmolarity ( Mosmol / L ) ( Calc. ) *Phsodiumbicarbonate , Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Castor Oilin Denatured Alcohol , Tab Folic Acid 5 Mg. , Inj. Cyanocobalamin ( Vitamine B 12 ) 1000Mcg / Ml; Soln For Im Or Sc Inj; Contains Benzyl Alcohol.- 10 Ml , Tab Calcium Carbonate-1.25 Gmi.E.1250 Mgvit D3-250 Iu, , Syp- Calcium Each 5 Ml Contains: Vitamin D3 ( Cholecalciferol ) I.P. 200 Iu, Vitamin B12 ( Cynocobalamin ) I.P.2.5Mcg, Calcium Phosphate 82Mg , Inj. Calcium Gluconate 100 Mg / Ml ( W / V ) 10 Ml , Each Ml Contains: Thiamine Hydrochloride 100 Mg, Riboflavin 5’ Phosphate Sodium 2 Mg, Pyridoxine Hydrochloride 2 Mg, Dexpanthenol 2 Mg, Niacinamide 100 Mg, With Benzyl Alcohol 2% As Preservative, In Water For Injection. Sodium Hydroxide And / Or Hydrochloric Acid May Have Been Used To Adjust Ph , Tab. Vitamin B Complex ( Therupetic ) N F I , Concentrated Vitamin A Solution I P 1, 00, 000 I U Each Ml Contains Vitamin A I Psynthetic Equivalent To About 109500I U / Gm - Bottle Of 100 Ml With Dropped Marked For Doses , Tab. Ascorbic Acid 500 Mg , Oint. Povidone Iodine 5%W / W 15 Gm , Povidone-Iodine 5% W / V Solution , Povidone Iodine 7.5% W / Vtopical Solutionscrub 500 Ml , Clotrimazole Cream : Cream Clortimazole 1% W / W- 15 Gm , Clotrimazole Dusting Powder 1% W / W - 30 Gm , Miconazole Cream: Miconazole Nitrate 2% W / W 15 Gm , Benzyl Benzoate Application 25 % W / W 100 Ml , Fluocinolone Acetonide Topical Ointment 0.025% Ointment - 15 Gm , Ciprofloxacin 0.3% W / Veye Drop ( 5Ml.Vial ) , Pre Filled Preferably In Glass Syringes In Double Pouch Packing . Inj. Hydroxy Propyl Methyl Cellulose Usp 2% W / V, In Sterile Isonic Base 2Ml Pfs , For Introcular Use , Tropicamide 1% W / V- 5 Ml , Povidone Iodine 5% W / V Eye Drops, Solution Each Single Dose Container Provides 25 Mg Of Iodinated Povidone In 0.5 Ml Of Solution. One Ml Of Solution Contains 50 Mg Iodinated Povidone , Tab Acetazolamide 250 Mg , Betaxolol Hcl 0.25% W / V- Ml , Timolol Maleate Eye Drops 0.5% W / V- 5 Ml , Atropine Sulfate Ophthalmic Ointment1%-5 Gm , Isopto Homatropine Methylbromide 2% Drop - 5 Ml , Tropicamide 0.8% W / V &Phenylephrinehydrocloride 5% W / V , Inj. Pralidoxime Chloride 500 Mg / 20 Ml , Inj. Pralidoxime Chloride 1G / 20 Ml , Tab. Dicyclomine 10 Mg , Inj. Dicyclomine 10 Mg / Ml - 2 Ml , Inj. Hyaluronidase ( 2 Ml Vial, Each Vial Contain 1500 International Units Of Hyaluronidase ) , Ciprofloxacin 0.3% W / V Dexamethasone 0.1% W / V E / D ( 5Ml.Vial ) , Ketoraloc Eye Drop 5 Ml Vial ( Ketoraloc Tromethymene 0.5% Solution ) , Moxifloxacin 0.5% With Prednisolone 1% Eye Drop 5Ml Vial ( Moxifloxacin Hydrocloride Equivalent To Moxifloxacin 0.5% W / V, Prednisolone Acetate - Usp 1% W / V, Benzalkonium Chloride Solution ( As Preservative ) – Ip 0.02% W / Vsterile Aqueous Base Q.S. ) , Proparacain 0.5% E / D ( Proparacain Hydrochloride 0.5% Eye Drop , Tropicamide 1% Plus Phenylephrine Hydrocloride 10% E / D , Pilocarp 2% Eye Drops ( Pilocarpine Nitrate 2% W / V Eye Drops ( 5 Ml Vial ) , Formaldehyde500 Ml , Benzylkonium Chloride 50% W / V . - 500 Ml , Dichlorometxynol 1.88% + Terpineol 2% ( Soap Solution Base ) 5 Ltr Jar , Sodium Hypochlorite Sol. Contains Not Less Than 4% And Not More Than 6% Sodium Hypochlorite. , Iv Normal Saline 0.9% , Budesodine Resp. , Tab Dabigatron 110 Mg , Inj Doxofyllin , Tab.N-Acetyl Cystein 600 Mg , Inj Piperacillin + Tazobactum 4.5Gm , Povidone Iodine Gargle , Tab-Favipiravir 200 Mg , Salbutamol Respiratory Solution , Vitamin B Complex Injection , Protein Tonic With Iron , Vitamins & Minerals Containing Pyridoxime Hcl , Niacinamideip 15.00Mg Iron Choline Citrate Ip 3.333Mg, Magnesium Chlorideusp 0.033Mg, Zinc Sulphate Ip 0.60Mg, Lysine Hcl Usp 20.00Mg, Protein Hydrosylate 20% 333.00Mg , Multivitamin Syrup With Mineral Supplements Containing Vitamin A Ip 1500 Iu, Cholecalciferol Ip 100 Iu Vitamin E Ip 5 Mg, Thiamine Hcl Ip1mg, Riboflavin Phosphate Sodium Ip 1 Mg, Pyrodoxine Hcl Ip 1Mg, Cynocobalamine Ip 1.25Mg, Niacinamide Ip 15 Mg, L-Lysine Hcl Usp 5 Mg, Pottasium Iodide Ip 50Mcg, Zinc Sulphate Ip 22.2Mg , Alcohol Based Hand Sanitizer Containing 2 Propanol 45% + 1-Propanol30%+Mecetronium Ethylsulphate0.2% , Alcohol Based Hand Sanitizer Containing 2 Propanol 45% + 1-Propanol30%+Mecetronium Ethylsulphate0.2% , Alcohol Based Hand Sanitizer Containing 2 Propanol 45% + 1-Propanol30%+Mecetronium Ethylsulphate0.2% , Alcohol Based Hand Sanitizer Containing 2 Propanol 45% + 1-Propanol30%+Mecetronium Ethylsulphate0.2% , Saline Ivstandheight Adjustable From 1325Mm Min. To 2390Mm Max. Stainless Steel Saline Rod. Strong Base Support. Pretreated And Epoxy Powder Coated With 8 Tank Process. The Product Should Be Pretreated And Epoxy Powder Coated With 8 Tank Process. He Manufacturer Should Have In House 8 Tank Pretreatment And Powder Coating Process. The Manufacturer Should Submit The Pollution Control Board Certificate For The Samecompany Should Have Following Certificates For Quality Standard Iso 9001-2015, Iso13485 From Notified Certifying Body And Ohsas, 18001 & 14001, Ce / Usfda , Fowler Bed With Mattress1.Overall Approx. Size:- Length :2170 Mm X Width : 1020Mm X Height : 600Mm 2. The Bed Frame Should Be Made Up Of Approx.60Mm X 30Mm Rectangular Crca 18G Tube, 3. Four Section Perforated Crca Sheet Topmade Up Of Approx. 18G Crca Sheet Double Press Bend On Four Sides And Should Have Uniformly Embossed Holes. Two Separate Screws For Backrest And Knee Rest Position By Individual Ss Folding Handles. Bed Should Have 5 Full Supports In Width Approx. 20Mm X 20Mm. Panel Is Supported By Box Stiffener Along The Length Duly Spotwelded. Ss Shall Be 304 Grade Confirming To Is 6911 – 1992. Detachable Head And Leg End Bows Of Approx. 31.75 Mm X 18G Dia. Stainless Steel Pipe. Off Set H Type Leg’S Should Be Made Up Of Approx. 31.75 Mm Diameter Long Pipe Welded To Approx. 34 Mm X 34 Mm X 2 Mm Thick Angle. Leg Should Be Fitted With Rubber Shoes. Four-Flush I.V.Rod Locations. Load Bearing Capacity Should Be 135 Kg At Every Point Of Horizontal Plain. A Mattress Should Be Of 100Mm Thick Pu Foam 32 Density Suitable Mattress Covered With Non-Woven Fabric & Good Quality Rexine With One Side Zip .The Foam Should Be Of Sleep Well. Company Should Have Following Certificates For Quality Standard Iso 9001-2015, Iso13485, Ohsas, 18001 & 14001, Ce / Usfda , Ecg Machine 1. Should Have Simultaneous 12 Channel Ecg Acquisition 2. Should Simultaneously Display Real-Time Ecg Waveforms 3. Should Have Automatic & Manual Mode Of Acquisiton 4. Should Indicate / Alarm If Any Lead Is Not Connected 5. Should Be Capable Of Producing Detailed Measurement & Interpretation Of The Acquired Ecg. 6. Should Have More Than 5” Or More Color Lcd Screen. 7. The Operation And Entry Should Be User-Friendly Directly Through Keyboard And Can Be Operable On Adults, Paediatrics & Neonates. 8. Should Have High Sampling Rate Of At Least 30000 Samples / Sec 9. Unit Should Have Frequency Range 0.05 Hz - 250 Hz ( For Children ) 10. Should Have Optional Culprit Arteria Criteria To Detect Probable Site Of Occlusion 11. Should Detect Pacemaker Pulses 12. The Machine Should Indicate &Display Any Wrong Placement Of Lead 13. Unit Should Display The Lead Signal Quality 14. Should Be Light Weight Less Than 3 Kgs Including Rechargeable Battery With Backup Of At Least 4 Hrs 15. Should Have Memory For Last Ecg Recording 16. Should Able To Store Ecg’S In Pdf Format On External Storage Devices 17. It Should Have An Inbuilt Thermal Printer Of Atleast 70 Mm With Many Different Print Formats 18. The Unit Should Have Both Auto And Manual Mode For Printing 19.The Chart Speed Should Be Of 25 & 50 Mm / S 20.Should Have Myogram Filter, Ssf Filter, Sbs Filter , Pulse Oxymeter With Adult , Children & Neonatal Probe Provide Fast & Reliable Spo2 And Pulse Rate Measurements On Any Patient, From Neonates To Adults Bright Easy-To Read Led Displays Indicates Spo2 And Pulse Rate Measurement User Selectable High & Low Alarm Limits For All Parameters 8 Segments Bar Graph Indicates Pulse Strength Sensor Alarm Indicates That The Sensor Has Been Disconnected Either From Patient Or From Oximeter Pulse Beep Is Sounded For Every Detected Pulse, With The Tone Varying According To Spo2 Value 3 Color Perfusion Led – Green ( Good Perfusion ) Orange ( Marginal Perfusion ) & Red ( Inadequate Perfusion ) Built-In Rechargeable Battery With Battery Back Up Of More Than 20 Hours Audible & Visual Low Battery Indication When 15 Minutes Remaining Ideally Suited For Operation Theatre , Icu Outpatient Clinics, Emergency Rooms , Or During Emergency Air Or Land Transport Wide Range Of Sensors Available With Most Of The Sensors Having 3 Meter Cable Lengths Display Indicator Led Display 0.5 Spo2, Pulse Rate 3 Color Led 5Mm Perfusion Status Red Led Light Bar Battery Green Led Light Bar Charging Spo2 Specification Range 0-100% Averaging 4, 8, 16 Beat Automatic Sensors Adult Finger , Pediatric Finger And Universal Y Sensor Pulse Rate Specification Range 18 To 300Bpm Alarm Ranges Sensor Disconnected, Limit Violations, Low Battery Power Requirement Battery Rechargeable Built In Sealed Lead Acid Battery 6V, 1.2Ah Charging Time 6 Hr. Battery Backup >20 Hours Ac Mains 230+- 15% Vac, 50Hz Classification As Per Iec 60601-1 Type Of Protection: Class Ii Degree Of Protection: Type Bf-Applied Part Mode Of Operation: Continues , Patientcot 3 X 6 1.Overall Approx. Size:- 1990Mm-2000 Mm L X 910Mm-920 Mm W X 590Mm-600 Mm H 2. The Bed Frame Should Be Made Up Of Approx.60Mm X 30Mm Rectangular Crca 18G Tube, 3. Fix Panel Should Be Made Up Of Approx. 18G Crca Sheet Double Press Bend On Four Sides And Should Have Uniformly Embossed Holes. 4. Bed Should Have 5 Full Support In Width Approx. 20Mm X 20Mm. 5. Panel Is Supported By Box Stiffner Along The Length Duly Spot-Welded.Ss Shall Be 304 Grade Confirming To Is 6911 – 1992. 6. Detachable Head And Leg End Bows Of Approx. 31.75 Mm X 18G Dia. Stainless Steel Pipe. 7. Off Set H Type Leg’S Should Be Made Up Of Approx. 31.75 Mm Diameter Long Pipe Welded To Approx. 34 Mm X 34 Mm X 2 Mm Thick Angle. 8. Leg Should Be Fitted With Rubber Shoes. 9. Four-Flush I.V.Rod Locations. 10. Load Bearing Capacity Should Be 135 Kg At Every Point Of Horizontal Plain. 11. A Mattress Should Be Of 100Mm Thick Pu Foam 32 Density Suitable Mattress Covered With Non-Woven Fabric & Good Quality Rexine With One Side Zip .The Foam Should Be Of Sleep Well. 12. Company Should Have Following Certificates For Quality Standard Iso 9001-2015, Iso13485, Ohsas, 18001 & 14001, Ce / Usfda , Bedside Locker Bed Side Locker Overall Approx Size : 400Mm W X 400Mm D X 800Mm H. Crca Sheet Cabinet & Drawer. Mounted On 50Mm -Dia Roller Wheels Membrane Top With Four Side Edge, Drawer Front And Door. Pre Treated & Epoxy Powder Coated With 8 Tank Process. Company Should Have Following Certificates For Quality Standard Iso 9001-2015, Iso13485, Ohsas, 18001 & 14001, Ce / Usfda , Oxygen Cylinder Jumbo1 ) It Should Be A Standard D Type Molybdenum Steel Cylinder. 2 ) The Capacity Should Be Of Approx 7.5 Cumt. At Pressure Of 900 - 1000Ibs / Square Inch. 3 ) Should Be Seamless.4.Cylinder Valve, With Valve Guard. Valve Seating Should Be Non Interchangeable With Other Types Of Cylinders. 4 ) Cylinder Filled With Medical Grade Nitrous Oxide. ( Empty Cylinders Not Accepted ) 5 ) Each Cylinders Must Be Manufacturing Date Having Current Year. ( Three Months Prior Date Of Manufacturing Will Be Acceptable ) 6 ) Each Cylinder Should Have Explosive Safety Certificate Obtained From Chief Controller Of Explosive , Oxygen Cylinder Small 1 ) It Should Be A Standard B Type Molybdenum Steel Cylinder. 2 ) The Capacity Should Be Of Approx 1.5 Cumt. At Pressure Of 900 - 1000Ibs / Square Inch. 3 ) Should Be Seamless.4.Cylinder Valve, With Valve Guard. Valve Seating Should Be Non Interchangeable With Other Types Of Cylinders. 4 ) Cylinder Filled With Medical Grade Nitrous Oxide. ( Empty Cylinders Not Accepted ) 5 ) Each Cylinders Must Be Manufacturing Date Having Current Year. ( Three Months Prior Date Of Manufacturing Will Be Acceptable ) 6 ) Each Cylinder Should Have Explosive Safety Certificate Obtained From Chief Controller Of Explosive , Digital B.P.Apparatus•Measuring Range : Cuff Pressure :0-295Mmhg Blood Pressure :30-280Mmhg Pulse Rate:40-180Beats / Minute • Accuracy: Pressure: ±3Mmhg Pulse Rate: ±5% • Environmental Temperature For Operation: 5 - 40 Degree • Environmental Humidity For Operation : <90% • Environmental Pressure : 80Kpa-105Kpa • Size : 135Mmx97mmx49mm • Measuring Method: Oscillometric Method, Automatic Air Inflation And Measurement • Memory Value: 2X60times With Time And Date Stamp , O2 Flow Meter Withhumidifier Bottleflow Meter Set Chrome Plated Metal Knob Pressure Gauge Makeempl / Lionex Intel Gauge 250Kg / Cm2r Humidifier Bottle Flow Meter Tube 0-15 L / Min Intel Nozzel With With 0 Ring Safty Gauge With Spanner , Patient Stool 1. Overall Approx. Dimension: 280Mm L X 280Mm W X 445Mm H. 2. It Should Have Stainless Steel Square Top Of 304G. 3. The Base Frame Of The Stool Should Be Made Up Of 25.4Mm X 25.4Mm X 18G Square Ms Crca Pipe. 4. Finish: All Mild Steel Components Should Be Thoroughly In House Pre-Treated Chemically To Remove Rust, Grease, Oil, Etc. By 8 Tank Dip And Drain Process, Including Separate Degreasing, De- Rusting, Phosphating Each Followed By Water Rinsing, Activation And Air Drying To Give Phosphate Coating. 5. The Treated Metal Surface Should Be Coated In-House With Epoxy Powder With Paint Film Thickness Of 60Microns ( Minimum ) And Oven Baked At 180 Degree To 200 Degree Centigrade. 19. Finishing & Workmanship In The Medical Furniture Is Of Prime Importance And Must Be Of High Standard. All Corners Shall Be Rounded Off So That There Shall Be No Sharp Corners And Holes, Should Be Burr Free. 20. All Process Parameters To Be As Per Documented Ims Procedures For Quality Assurance ( Iso 9001:2015, Iso 14001:2015 2004, Ohsas 18001: 2007& Iso 13485:2016 Quality Management Systems ) , High Flow Nasal Machine With All Assesoriesthe Fan Less Monitor Should Measure Ecg, Respiration, Hr, Spo2, Nibp, Dual Channel Temperature, Dual Ibp And Etco2 System Must Have These ( Critical Features ) : ? Must Have Valid European Ce Certificate With Four Digit Notified Body Number Certificate ( Certificate To Besubmitted ) . ? Must Have Valid Qms ( Iso 9001 And En Iso 13485 ) Certificate. ? Must Have Lan Bidirectional Networking For Cms To Beupgradable. ? Must Have Both Audio And Color Coded Visual Alarms For Vitalsigns. ? Nibp Measurement Unit Must Be In Mmhg / Kpaselectable. ? Monitor Must Be Of Latest Fan Less Type Technology To Avoid Dust & Microbes Accumulation & To Reducemaintenance. ? Must Have 1000 Readings Of Nibp, 480 Hrs Of Tabular & Graphical Trends And 1000 Events Recording Of Alarm Condition Withwaveform. ? Manufacturermusthavecompanyownedbranchstateoffice Within 200-300Km From Yavatmal Forsale&Service.Mentionedtheaddresson Manufacturer Letter Head . System Should Have These: ? Minimum 12.1” With Touch Screen Or More Color Tft Display For Bettervisibility. ? Should Be 800 X 600 Resolutions Or Better With Clear Waveform And Easy To Read Numericvalues. ? Should Be Up To 12 Real Time Waveformsdisplay. ? Should Have Facility For Charging From Both 12 Vdc And 220Vac. ? Should Have Facility Of Atleast 3 Different Views Near View, Far View, Only Para View With Nightmode. ? Should Have Different Tones For Critical Intermediate And Advisoryalarms. ? Facility Of Arrhythmia And St Analysis. ? Should Have Facility Of Colour Codes On Screen For Differentalarms. ? Ecg Waveform Should Have Cascadingfeature. ? Should Have 24 Hrs. Full Wave Form Disclosure Storage Of Ecg, Spo2 With Automatic Replayoption. ? Facility For Customizable To View Only Selected Parameters & Waveforms With Color Changingoption. ? Should Have Alarm Limits Value Highlighted In Trend Table With Respective Colour As Ofwave. ? Should Be Able To Change Any Lead Waveform On Main Screen With Singleclick. ? Should Have Photo Button Option To Capture The Screen Shot Ofdata. ? Should Have 1000 Alarm Snapshot Withzoom. ? It Should Be Extremely Flexible Multiple User Definablesettings. ? Facility Of Manual Adjustment Of Voltage Oramplitude. ? Should Be Able To Connect Withhl7 ? Should Have Defibrillatorsynchronization. ? Should Have Provision To Adjust Isoelectric, J And Post J Points Inmedians. ? Should Be Able To View Worldwide Live Data Of Mpm Throughcms. ? Should Have Vga & Hdmi Port For External Displayconnectivity. ? Should Have Rechargeable Battery With Minimum 3 Hoursbackup. ? Should Have External Usb To Transfer Alarms And View Inp.C. ? Software Of Can Be Upgraded At Client Site Throughusb. Display: • Screen Type: Color Tft With Touch • Display Area: 12” • Resolution: 800 X 600 • Trends: 1000 Readings Of Nibp, 480 Hrs For All Other Parameters And 1000 Events Recording Of Alarm Condition With Waveform. • Display Modes: Demo Mode, Night Mode And Customize View For Selected Parameters And Waveforms. • Alarms: Both Audio And Color Coded Visual Alarms For Vital Signs. ( Polyphonic Sound For Alarms ) • Usb Storage: Alarm Screen Snapshot For Review And A4 Size Printing On Pc. • Data Storage & Review: 24 Hours Ecg, Spo2 & Respiration Storage And Review. • Waveforms: Up To 12 Waveforms Can Be Displayed At Any Time. Numeric Display Includes Hr / Pr / Spo2 % / Nibp With Map / Resp. / Temperature 1 And 2 / Ibp1 / Ibp2 & Etco2 • Software Upgrade: Through Usb Ecg: • Leads Selection Selectable 3 / 5 / 12 Leads I, Ii, Iii, Avr, Avl, Avf, V1, V2, V3, V4, V5, V6 In 12 Lead Configuration . I, Ii, Iii, Avr, Avl, Avf, V In 5 Lead Configuration . I, Ii, Iii In 3 Lead Configuration ( Any One Lead At A Time ) • Heart Rate Range: 30 To 350 Bpm • Heart Rate Accuracy :± 3 Bpm • Defibrillator Protection: Protection Against 360 Joule Discharge And Electrostatic Potentials Spo2: • Saturation Range: 0% To 100% • Pulse Rate: 15 Bpm To 300 Bpm • Accuracy: 70% To 100% ±2 Digits 50% To 69% ±3 Digits 0% To 49% Unspecified • Pulse Rate Accuracy:± 3 Bpm • Cautery Protection: Protected Against External Cautery Interference Nibp: • Method: Automatic Oscillometric • Bp Measurement Unit: ( Mmhg ) ( Kpa Optional ) • Auto Mode: Automatic Bp Measurement At 2, 3, 5, 10, 20, 30, 60, & 120 Minutes. • Manual Mode: Single Measurement Initiated By Nibp Start / Stop Switch. • Stat Mode Average Of All Readings In 5 Minutes • Pulse Rate Range: 15 To 300 Bpm Respiration: • Technique Trans-Thoracic Impedance • Range 0 To 150 Breath / Min • Accuracy ± 2 Or ± 3 % Breath / Min • Resolution 1 Breath / Min • Apnea Alarm 10 To 40 Sec • Display Sweep Speed 12.5, 25, 50 Mm / Sec Temperature: • Range 0 To 50°C • Accuracy ± 0.1 °C • Channels 2 Nos. Dual Ibp: • Channels 2 Nos. • Measurement Range -10 To 300 Mmhg • Resolution Range 1Mmhg • Accuracy ± 1 Mmhg Or ± 2%, Whichever Is Greater Etco2: • Etco2 0 To 99 Mmhg • Rr 0 To 150 Rpm • Etco2 Resolution 1 Mmhg • Accuracy Etco2 ± 2 Mmhg @ <5% Co2 • Rr Etco2 • Accuracy ±2 Rpm • Apnea Alarm Yes Recording System: • Printer : Single / Dual / Three Channel Printing • Thermal Paper Thermal Printing Electrical Specifications: • Internal Battery 11.1V, Li-Ion Rechargeable • Battery Backup Min. 3 Hours • Operation Ac / Dc Operation • Ac Mains 100 – 240 Ac, 50 / 60 Hz, 1 Amp • Dc Socket 12 Vdc Central Monitoring Station: System Should Have These: ? Should Have Facility To Select Upto 8 Number Ofbeds. ? Should Have User Friendly Interface Based Onwindows. ? Should Have Central Monitoring Capability Upto Seven Parameter:- ( 1 ) Ecg ( 2 ) Spo2 ( 3 ) Nibp ( 4 ) Respiration ( 5 ) Temperature ( 6 ) Ibp ( 7 ) Etco2. ? Should Have Facility To Display 10 Second Of Data For Selectedbed. ? Should Have Tabular Trends With Marked Alarm Events For Allparameters. ? It Should Have Bi-Directional Communication – Ease Of Taking Nibpreadings. ? Should Have Ecg Lead Selection For Any Bed From Centralstation. ? Should Have Individual Alarm Settings For Eachbed. ? Should Have Facility For Selectable Wave Color For Each Displayarea. ? Should Have Zoomed View Of A Bed Identical To That Of The Monitor At Thatbed. ? Freeze / Unfreeze Option For Waveform Should Bethere. ? There Should Be True Print Of Ecgleads. ? Facility For Entering Doctor’S Name, Diagnostic And Remarks For Individual Patient Should Bein Cms. ? Should Have Unique ( Configurable ) Setup For Everybed. ? 8 Lead View Is Displayed For Selected Bed. ? It Should Have Online Supportfeature. ? It Should Have Online Update Facility Available Throughsoftware. ? Should Have Facility To Preview Page Before Giving Printcommand. ? Respiration Apnea Should Be Seen Oncms. ? Module Not Connected ( Nc ) Message Should Be Seen Oncms. ? Spo2 Sensor Error And Probe Not Connected Message Should Be Seen Oncms. ? Cms Should Show Ecgarrhythmia. ? Facility Of Nibp Air Leak & Block Message On The Screen If Any Of The Error Occurs Should Bein Cms. ? Cms Should Have Printing Option Forevents. • Numbers Of Beds: 8 • Parameters: Ecg, Respiration, Spo2, Temperature, Nibp, Dual Ibp, Etco2 • Trend: Tabular And Graphics Trends • Communication: Ethernet / Lan Communication With Monitor Bi-Directional Communication • Display: Waveforms, Numeric Data, Graphical Display, Tabular Display And Calculation • Wave Analysis : Freeze / Unfreeze • Alarm: Audio / Visual Alarms • Wave Color: Selectable For Each Display Area • Sweep Speed:6.25, 12.5, 25 And 50 Mm / Sec • Storage Of Patient Data: 30 Days • Data Display For Selected Bed: 10 Sec • Views:Normal, Maximize And Monitor View • Error Massage:Facility To Display Error Massage-: Ecg Lead Off Massage Seen On Cms. Respiration Apnea Is Seen On Cms. Module Not Connected ( Nc ) Message Is Seen On Cms. Spo2 Sensor Error And Probe Not Connected Message Is Seen On Cms. Cms Shows Ecg Arrhythmia. Nibp Air Leak & Block Message Appears On The Screen If Any Of The Error Occurs. • Printing Facility:Table Trend Printing And Data Review Printing • Online Facilities: Software Update And Online Support • Comments: Facility For Entering Doctor’S Name, Diagnostic And Remarks For Individual Patient. • It Is Mandatory To Enclose All Above Certificates. , Bipap Machine•Ipap / Epap: 4 –40 Cm H2o / 4-25 Cm H2o • Ventilation Modes: Cpap, S, S / T, Pc, T, Avaps-Ae, • Target Tidal Volume: 200 - 1500 Ml • Breath Rate: 0 - 40 Bpm • Rise Time: 1 ( 100Ms ) - 6 ( 600Ms ) • Humidification: System One Humidity Control And ‘Dry Box’ Technology • Hybrid Ventilation: Avaps ( Average Volume Assured Pressure Support ) • Avaps Rate: 0.5 To 5 Cm H2o / Min • Inspiratory Time: 0.5 To 3 Sec • Alarms: Patient Disconnection, Apnea, Low Minute Ventilation, Low Tidal Volume, High Respiratory Rate • Monitoring: Pressure, Tidal Volume, Minute Ventilation, Respiratory Rate, Leak • Data Management: Encorepro 2 And Directview Software Compatible With Oximetry Module, Advanced Detection Of Residual Respiratory Events ( Apnea / Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, Rera, Large Leak And Snore ) • Dc Power Source: 12Vdc, 5.0 A • External Battery: 24Vdc, 4.2 A • Battery Backup: 5 Hours At Ipap 12 / Epap 7 Cm H2o And 12 Bpm ( 5-4 Hours ) • Noise Level: Minimum Alarm Sound Level 60 Db Warranty: 2 Years , Oxygen Concentrator• Should Use Pressure Swing Absorption ( Psa ) To Produce Oxygen Gas Output • The Oxygen Concentrator Should Haveflow Rate Of 0.5-5 Lpm And Should Provide More Than 90% Oxygen Purity At All Flow Rates •Should Have Only Bacterial And Inlet Filters And Must Be Designed With Fewer Parts Resulting In Lower Overall Maintenance Cost. • Should Have Low Power Consumption Less Than 300 Watts In Order To Reduce Cost. • Should Also Have Metal Cannula Connector For Greater Durability. • Should Have A Recessed Flow Meterwhich Reduces The Risk Of Breakage • Should Not Weigh More Than 15 Kgs • Should Have Quiet Operation With Sound Level Less Than 45Db. • Should Use Compressors Of Usa / European Make. Must Mention The Manufacturer Name. •Should Have And Interface Panel With On / Off Switch And Alarm Indicators. • Should Have Audible And Visual Alarms In Case Of Power Failure • Should Have Alarms For Low And High Oxygen Percentage. • Should Have An Internal Tubing Storage Keeps Tubing Conveniently Available For Use. • Should Be Usfda & Ce Approved • Should Come With 3 Years Of Warranty • Should Be Provided With Humidifier Bottle And Nasal Cannula. • Optional Accessories With An Additional Cost: Humidifier Connector Tube, Standalone Pediatric Flow Meter, Integrated Pediatric Flow Meter, Flow Meter Locking Kit, Caster Break Kit. , Stretcher On Trolly Overall Approx. Size: 2020Mm L X 590Mm W X 740Mm H. Approx. 31.75Mm Dia. Crca Tubular Framework Trolley Mounted On Four 150Mm-Dia Heavy Duty Castors. Detachable Powder Coated Top. Ss Plain Iv Rod With Two Location & Oxygen Cylinder Holder. Iv Rod ( Code: 514 ) With Two Location & Oxygen Cylinderholder. Pretreated And Epoxy Powder Coated With 8 Tank Processcompany Should Have Following For Quality Standard Iso9001-2015Iso 138485 From Notified Certifying Body And Ohsas, 18001 &14001 Ce / Fda , Ventilators • Fully Microprocessor Controlled Having Volume Cycled & Time Cycled With Volume And Pressure Support • Mode Of Operation :- A / C Mains With Battery Backup Inbuilt 5 Hours Or More For Complete System Includingair Source • Application: Adult As Well As Pediatric Application Minimum 5 — 6 Kg Body Weight • Driving Gas:- Air Source - Turbine Only, Compressor / Blower / Piston Not Allowed High Pressure Tubing With Adapters To Be Provided To Fit Hospital Central Oxygen Connection And To Fit Oxygen Cylinder • Ventilator Modes And Functions:- Invasive Modes:- Assist — Control ( Volume Controlled Ventilation & Pressure Controlled Ventilation ) Simv ( Volume Controlled Ventilation & Pressure Controlled Ventilation ) Simv + Pressure Support ( Volume Controlled Ventilation & Pressure Controlled Ventilation ) Cpap , Cpap + Pressure Support • Non- Invasive Modes ( Niv ) With Mask Must Be Available Independent And Separate Mode:- Control, Assist Control, S1mv + Psv, Cpap + Psv. Biphasic With Psv / Bipap / Similar • Combination Advanced Modes:- Volume Cycle With Demand Flowing In Control, A / C, Simv Modes. Prvc / Auto Flow Or Similar Mode, Simv And With Volume Limit. Aprv Mode / Bi-Vent. • Common Ventilatory Parameter Settings:- Peep / Cpap Adjustable Flow Cycled Ventilation For All Modes. User Adjustable, Automatic And Interactive Apnea Back-Up Ventilation Adjustable I:E Ratio User Adjustable, Automatic And Interactive Apnea Back- Up Ventilation With Choice Of Selecting Apnea Back-Up Mode Manual Breath Adjustable Bias ( Expiratory ) Flow Or Automatic. Trigger Sensitivity: Flow Adjustable Fi02: Adjustable ( 21 To 100% ) And Monitored. 100% Oxygen Flush. Negative Inspiratory Force Manoeuvre Or Rapid Shallow Breathing Expiratory Hold. Inspiratory Hold. Inspiration Synchronized Inbuilt Nebulizer . It Should Have Facility For Inbuiltetco2 Monitoring With Waveform. ( External Monitor Will Not Be Allowed ) • Alarms / Indicators :- Audio & / Or Visual With Adjustable Alarm Volume: ? Power Failure ? Mode Of Operation: Mains / Battery ? Battery: Fully Charged / Low ? Ventilator Inoperative ? Unusual / Incorrect Settings ? Gas Supply Failure For : Oxygen And Air ? Insp. Time Limit And I:E Ratio Limit ? Pressure / Flow Transducer ( Sensor ) Failure. ? Triggered Breath Indicator ? Apnea ? High Peak Pressure. ? Fi02: High / Low ? Minute Volume: Low. ? Airway Pressure: High / Low And High Peak Pressure. ? Peep / Cpap : High Low ? Breath Rate : High • Displays For Monitoring:- Driving Gas Supply Pressure ( Air & Oxygen ) Fio2 Etco2. Resp. Rate: Ventilator & Patient Time: Inspiratory, Expiratory, Le Ratio Inspired Tidal Volume Expired Tidal Volume Minute Volume Airway Pressures: P-Max. P-Mean & P-Plateau, Peep Auto Peep Minimum 12 Inches Inbuilt And Incorporated Touch Screen Color Graphics Display . Waveforms: Flow, Volume And Pressure — Airway ( Paw ) , And With Freeze Facility. Loops: Flow / Volume, Paw / Volume With Memory, Colored And Freeze Facility Trend Of All Monitored Parameters For Last 72 Hours Compliance Resistance • Range Or Pattern For Settings Fi02 : 21 To 10 Insp. Flow Rate : 10 To 100 Ltrs / Min Insp. Flow Waveform : User Selectable, Square, Decelerating Resp. Rate : 5 To 80 / Min Inspiratory Time : 0.3 To 7 Sec Inspiratory Pause Time : 0.1 To 2 Sec I : E Ratio : 1:150 To Inspiratory Tidal Volume Limit : 50 Ml To 2000 Ml Peep : 0 - 35 Ems Of H20 Pressure Support : 0 - 40 Cms Of H20 Flow Cycle For Pc & Psv Or Inspiration Flow Termination Criteria:-: 0, 5 To 30% Of Peak Flow Simv Rate : 1 To 40 B.P.M. Apnea Time Adjustable : Up To 60 Sec Apnea Back Up Rate : 12 B.P.M. Onwards Flow Trigger : 1 Lpm. To 15 Lpm Volume Limit : 50 Ml To 2000 Ml Capnography: - Inbuilt Co2 Monitoring With Mainstream Sensor With Reusable Airway Adaptors For Use With Adult Patients. Should Monitor Following Parameters Etco2, Waveform ( Capnogram ) , Alarms: High Etco2 And Low Etco2 • Additional Accessories: The Following Accessories Shall Be Supplied With Each Unit. Reusable, Autoclavable Dual Limb Adult Breathing Circuit — 2 Nos. Each Stand With Support Arm For Breathing Circuit ( From Same Manufacturer ) — I No. Testing Lung — 1 No. Adult & I No. Pediatrics With Restrictor. Reusable Nebulizer Should Be Supplied Along With Each Ventilator. Disposable Circuit For Adult Application, Including Its Adapters — 50 Nos. And For Pediatrics -25 Nos. Reusable Niv Mask With Harness — 2 Nos Full Face Facial Mask Each Of 3 Different Sizes. Should Be Supplied With Reusable Etco2 Sensor With Cable And I No. Of Reusable Adult Airway Adaptors And 10 Nos. Disposable Adult Airway Adaptors With Each Unit. • Flow Sensor—With Each Unit Reusable — 2 Per Machine Or If Disposable 50 Per Machine. Ventilator Trolley And Support Arm Should Be Imported Trolley Of Same Make • Internal Turbine Should Offer Long Life Of More Than 8 Years . It Should Be Replaced Free Cost Within 8 Years If Any Technical Problem / Failure Is Occurredduring 8Years.Thesamefreereplacement Warrantyof Internal Turbine Should Be Attached With Technical And Commercial Documents. Ventilator Should Have Paramagnetic 02 Sensor Or If Galvanic 02 Sensor Then Vendor Should Supply Galvanic 02 Sensor Free Of Cost Till 8 Years From The Date Of Installation. Should Have 2 Nos. Autoclavable & Reusable Expiration Cassette / Valves For Complete Disinfection Capability. For Highly Infectious Patient, Vendor Should Supply At Least 10 Disposable Expiratory Valves / Cassettes Or 4 Reusable Expiration Valves In Case No 5 03, T6, T, Disposable Valve Are Possible Etco2 Sensor Shall Be Covered Under 3 Years Warranty And 5 Years Cmc. All Standard Accessories Should Be Provided With Machine Consumables:- Rates Will Be Freeze For 8 Years Reusable, Autoclavable, Dual Limb Adult &Paediatric Breathing Circuit Test Lung Adult Test Lung Pediatrics Disposable Circuit Adult And Pediatrics Flow Sensor Disposable Flow Sensor Reusable Full Niv Face Mask Of 3 Different Sizes Etco2 Sensor Cable Etco2 Adaptor — Reusable And Disposable General Terms And Conditions All The Above Equipments Shall Be New And Manufactured From Virgin Materials. All The Requirements Of This Supply Shall Be Necessary Sourced From The Original Equipment Manufacturer Of The Model Quoted Except Ups, Printer, Humidifier, Computer Which Shall Not Be Necessary Sourced From The Original Equipment Manufacturer Of The Model Quoted But Should Be Compatible With The Quoted Model. In Case The Machine Is Imported One No Import Substitution Is Permitted Neither Before Third The Award Nor After The Award For Any Part Or Accessory. Party Inspection Certificate Should Be Applied From The Port Of Origin Of Shipping Of Equipment. Equipment Shall Operate On 230 V, Single Phase, 50 Hz Electric Supply. The Necessary Protective Relaying / Circuitry Shall Be There With The Machines. The Mains Supply Voltage Variation May Be Max.±15% And Frequency Variation Maximum 13 %. Equipment Shall Operate On 230 V, Single Phase, 50 Hz Electric Supply. The Necessary Protective Relaying / Circuitry Shall Be There With The Machines. The Mains Supply Voltage Variation May Be Max.±15% And Frequency Variation Maximum 13 %. True On Line Ups With Isolation Transformer For Complete System ( For Minimum 2 Hours ) Including Air Source For Complete Protection Against All Types Of Input Supply Variation. The Equipments And All Accessories ( Ventilator, Capnography And Air Source ) Must Be Ce Mark From European Conformity ( Ec ) Notified Bodies Issued From European Address And Valid Us Fda & Should Have Approval From Usfda To Use The Ventilator For Patient With Body Weight Of 5Kg Or More And Documentary Evidence To That Effect Shall Be Uploaded The Equipments Shall Be Having Warranty Of Three Years As Described In The Tender Document Elsewhere. The Warranty And Cmc Shall Cover All The Spare Parts Required For Maintenance Of Machine / Equipment For Total 8 Years ( Warranty 3 Years And Cmc 5 Years ) Irrespective Of Whether Those Are Treated As Consumables Or Otherwise. The Successful Bidder Has To Ensure That All The Required Spares And Services Are Available During The Period Of Cmc And 2 Years After The Contract Period Of Eight Years. The Equipments Should Be Provided With One Hard Copy In Original Of The Detailed Service Manual And Operation Manual. Further, A Soft Copy Is Also Required. He Equipment Must Be Tropicalized As Below: , Oxygen Cylinder Trollypush Type With Two Wheels. Must Carry 13.5 Kg Oxygen Cylinder Pretreated And Epoxy Powder Coated With 8 Tank Process. The Product Should Be Pretreated And Epoxy Powder Coated With 8 Tank Process. He Manufacturer Should Have In House 8 Tank Pretreatment And Powder Coating Process. The Manufacturer Should Submit The Pollution Control Board Certificate For The Samecompany Should Have Following Certificates For Quality Standard Iso 9001-2015, Iso13485 From Notified Certifying Body And Ohsas, 18001 & 14001, Ce / Usfda , White Bed Sheet 60 X 90 , Green Bed Sheet 60 X 90 , Blue Bed Sheet 60 X 91 , ( Light Pink ) Bed Sheet 60 X 90 , Baby Woolen Blanket 48 X 60 , Red Blanket 60X90 , Red Woolen Blanet 60 X90 , Solapuri Chaddar 60 X90 , White Turkish Napkin 27 X 54 , White Turkish Towel30 X 60 , Dr.Towel 27 X 54 , Honey Comb Towel 27 X 54 , Honey Comb Towel 30 X 60 , Satranji 9 Ft X 12 Ft , Panja Dari 3 X6 , White Casemet Cloth , Cloth For Operation Theaters ( Green ) 54 , Curtain Cloth ( Mtr ) Green , Green Appron Surgeon ( Redymade ) Size 38, 40, 42, 44, 46 , White Appron Surgeon ( Redymade ) Size 38, 40, 42, 44, 46 , Pillow Covers18 X24 , Cloth Mask ( Green ) , Cotton Mattresses 10 Kg , Mattresses Coir Fome Rexin Cover 4 ( Size 3Ft X 6 Ft ) , Mattresses Coir Fome Rexin Cover 3 ( Size 3Ft X 4 Ft ) ( For Peadiatric ) , Pillow ( 1.5 Kg ) Coir , Piloow ( 1.5 Kg ) Cotton , Rexin ( Mtr ) , Absorbent Cotton Wool 300 Gm Net , Absorbent Cotton Wool 500 Gm Net , Adhesive Plaster ( Zinc Oxide ) 7.5 Cm X 5 Mtr- Cotton Basedroll Of 7.5 Cm X 5 Mtr , Adhesive Plaster ( Zinc Oxide ) 10 Cm X 5 Mtr - Cotton Basedroll Of 10 Cm X 5 Mtr , Elastic Adhesive Bandage ( With 20% Zinc Oxide ) With Adhesive Masss Weight Nlt 145 Gsm % Stretch - Not Less Than 75%% Regain Not More Than 65% - Roll Of 10 Cm X 4 Mtr , Label Size 6 Cm X 2.5 Cm Chemical Band : 4 Cm X 1 Cm With Green Colour & 5 Indicator On One Strip. 1 Box Contains 10 X 100 Mean 1000 Indicator Labls With Iso & C E Certification , Bandage Cloth As Per Schedule Fiiofdrug And Cosmectic Act 1940 Than Of 100 Cm X 20 Mtr , Absorbent Surgical Gauze F Iidrug And Cosmectic Act 1940 ( 50Cmx18 M ) In Than , Surgical Blade / B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil Should Be To Fitting To Handle I S I Mark No. 22 Surgical Blades Pre-Sterile With Gamma Radiation For Handle No. 4 Sizes Latest Isi Certification With Ce Certification Will Be Preferred , Surgical Blade / B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil Should Be To Fitting To Handle I S I Mark No. 23 Surgical Blades Pre-Sterile With Gamma Radiation For Handle No. 4 Sizes Latest Isi Certification With Ce Certification Will Be Preferred , Surgical Blade / B.P. Blade Pre Sterile Wrapped With Antirust Paper In Aluminium Foil Should Be To Fitting To Handle I S I Mark No. 24 Surgical Blades Pre-Sterile With Gamma Radiation For Handle No. 4 Sizes Latest Isi Certification With Ce Certification Will Be Preferred , Crapebandages 10 Cm X 2.5 Mtr 100% Cotton With ( As Per Isi Specification ) The Bandage Comes With Flesh Color With A Blue Line In The Middle Or Without Middle Line.Stretched Length :4Mt / 4. 5Mt-Clip:With Or Without Clips, Elastic Band Clips Or Metal Band Clips , Crapebandages 15 Cm X 2.75 Mtrs ( As Per Isi Specification ) The Bandage Comes With Flesh Color With A Blue Line In The Middle Or Without Middle Line.Stretched Length :4Mt / 4. 5Mt-Clip:With Or Without Clips, Elastic Band Clips Or Metal Band Clips , Catheter Folleys Self Retaining No. 12 ( 2 Ways ) Baloon 30 Ml Foleys Urinary Catheter Silkolatex ( Pre-Sterile ) 2 Way Sterile Non-Toxic Sizes 12With Ce Certification , Catheter Folleys Self Retaining No. 16 ( 2 Ways ) Baloon 30 Ml / Foleys Urinary Catheter Silkolatex ( Pre-Sterile ) 2 Way Sterile Non-Toxic Sizes 16 With Ce Certification , I V Cannula Sterile Disposable Sterile Type Packing P.T.F.E / Fep / Polyurethane Catheter With Needle With Wings 20 G 25-32 Mm Length ( E T O Sterile ) , I V Cannula Sterile Disposable Sterile Type Packing P.T.F.E / Fep / Polyurethane Catheter With Needle With Wings 22 G 25-32 Mm Length ( E T O Sterile ) , I V Cannula Sterile Disposable Sterile Type Packing P.T.F.E / Fep / Polyurethanecatheter With Needle With Wings 24 G 19 Mm Length ( E T O Sterile ) , Infusionset – Sterile, Non-Toxic Pvc With Soft Transparent, Kink Resistant Tube, Latex Tube For Convenient Extra Medication, Plastic Soft Transparent Murphy Chamber, Smooth Plastic Spike, Sharp Enough For Easy Piercing. Easily Controllable Roller Clamp Needle - 20 / 21 G. Leak Proof Double Polyethlene Packing. Or Blister Pack Batch Number, Mfg. & Expiry Date, Sterility Date & Method Must Be Mentioned. ( E T Osterile ) , Rolledcotton Bandages As Per Schedule F Iidrug & Cosmetic Act 1940 10 Cm X 4 Mtr , Rolledcotton Bandages As Per Schedule F Iidrug & Cosmetic Act 1940 15 Cm X 4 Mtr , Rolledcotton Bandages As Per Schedule F Iidrug & Cosmetic Act 1940 7.5 Cm X 4 Mtr , Sterile Disposable Surgical Gloves No 6 Powder Free Gloves. 100% Electronically Tested. C E Certification. Packet Of 25 Pair , Sterile Disposable Surgical Gloves No 6.5, Powder Free Gloves. 100% Electronically Tested. C E Certification. Packet Of 25 Pair , Sterile Disposable Surgical Gloves No 7 Powder Free Gloves. 100% Electronically Tested. C E Certification. Packet Of 25 Pair , Sterile Disposable Surgical Gloves No 7.5 Powder Free Gloves. 100% Electronically Tested. C E Certification. Packet Of 25 Pair , Sterile Disposable Surgical Gloves No 8 Powder Free Gloves. 100% Electronically Tested. C E Certification. Packet Of 25 Pair , Rubber Gloves 6 Operation Gloves ( Non-Sterilised ) 6 Pre-Powdered, Bis Specifications Gloves, Surgical Rubber Made Of Hypoallergic Latex. 100% Electronically Tested, Is Certification With Ce Certification Packet Of 25 Pairs , • Rubber Gloves 6.5 Operation Gloves ( Non-Sterilised ) 6.5 Pre-Powdered, Bis Specifications Gloves, Surgical Rubber Made Of Hypoallergic Latex. 100% Electronically Tested, Is Certificationwith Ce Certification Packet Of 25 Pairs , Rubber Gloves 7 Operation Gloves ( Non-Sterilised ) 7 Pre-Powdered, Bis Specifications Gloves, Surgical Rubber Made Of Hypoallergic Latex. 100% Electronically Tested, Is No.4148 With Ce Certification Packet Of 25 Pairs , • Rubber Gloves 7.5 • Operation Gloves ( Non-Sterilised ) 7.5, Pre-Powdered, Bis Specifications Gloves, Surgical Rubber Made Of Hypoallergic Latex. 100% Electronically Tested, Is Certification With Ce Certification • Packet Of 25 Pairs , Urine Collection Bag - Disposable Sterile With Accurate Calibration Non Toxic, Tube Length 42Manufactured From Clinical Grade Pvc Sheet. Super Smooth Kink Resistant Tube, Made From Medical Grade Pvc. With Connector. Non Return Valve And Drainage Outlet. Provided With Hanging & Carrying System. Capacity : 2000 Ml. Approx. Sterile / Disposable / Individual Packed. , Transperant Tube Mucus Extractor For Neonatal & Infants.Sterile Pyrogen Free, Non Toxic The Capacity Of The Mucus Extractor Is 25Ml And A Spare Cap Is Also Provided For The Sealing.Soft And Kink Resistant Tubing With Frosted Surface A Traumatic, Soft Rounded, Beveled Open Tip. Capacity: 25 Ml. , Disposable Umbilical Cord Clamp Are Made From Non Toxic Medical Grade Polymer. 1. Material: Pvc, Pe, Pp, Abs Etc. 2. Sterilize By Ethylene Oxide Gas 3. Supplied Sterile In Individual Peel-Able Polybag. , Auto Disable Syringe Non Reusablewith Needle - 0.5 Mlbarrel: Polypropylene Plunger: Polypropylene Gasket: Natural Rubber Packaging: Soft Blister Luer Type: Luer Lock And Luer Slip Sterilization: Eto Capacity : 0.5 Ml Graduations : ‘0’ & ‘0.5’ Ml Material Of The Syringe : Polypropylene Needle : 23G 1 , 24G¾ Prevented From Re-Use By : One-Way Valve Technology , Triple Layer Face Mask Nose Clip -Tie On Mask Of Non-Woven, Hypoallergenic 3 Ply Construction With Filter In Between Offering >99 Percent Standard With 4 Tie Strings , Scalp Vein Sets No.22 ( Superior Quality Non Toxic Pvc Sterile Pyrogen Free, Sharp & Rust Free Needles For Easy Cannulation Properly Secured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper ) Disp. Scalp Vein Set Eto Sterilised Pyrogen Free Short Bevelved Silliconised Needle Size22 Length 3 / 4 With Ce Certification , Scalp Vein Sets No.23 ( Superior Quality Non Toxic Pvc Sterile Pyrogen Free, Sharp & Rust Free Needles For Easy Cannulation Properly Secured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper ) Disp. Scalp Vein Set Eto Sterilised Pyrogen Free Short Bevelved Silliconised Needle Size23 Length 3 / 4 With Ce Certification , Scalp Vein Sets No.24 ( Superior Quality Non Toxic Pvc Sterile Pyrogen Free, Sharp & Rust Free Needles For Easy Cannulation Properly Secured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper ) Disp. Scalp Vein Set Eto Sterilised Pyrogen Free Short Bevelved Silliconised Needle Size24 Length 3 / 4 With Ce Certification , Disposable Sterile Spinal Needle Quincke Or Pencil Point Size: 23 Gl50-150Mmiso And Ce Certificate , Disposable Sterile Spinal Needle Quincke Or Pencil Pointsize: 24 Gl50-150Mmiso And Ce Certificate , Disposable Syringes 2Ml With Needle 21G-24G X 1 Inch , Ribbon Pack / Blister Pack, Cecertification , Disposable Syringes 5Ml With Needle 21G-24G X 1 Inch , Ribbon Pack / Blister Pack, Cecertification , Disposable Syringes 10 Ml With Needle 21G X 1½ Or 22G X 1¼ Inch, Ribbon Pack / Blister Pack, Cecerti. , Disposable Syringes 20 Ml With Needle 21G X 1½ Or 22G X 1¼ Inch, Ribbon Pack / Blister Pack, Cecertif. , Disposable Syringes 50 Ml, Ribbon Pack / Blister Pack, Cecertification , Disposable Cap Is Made From Spun Bond Polymer Non-Woven Fabric, Thikness 15-40 Gsm Color: Blue / White / Green Size: 21 / Free Size , Disposable Delivery Kit - •High Quality •Sterilized Specifications: For Doctors Use Disposable Head Cap. X 1 Disposable Face Mask With Filter X 1 Disposable P.V.C. Apron Full Length X 1 Disposable Shoe Cover X 2 For Patient Use Disposable Pvc Drapes For Delivery Table-Length Upto Bucket ( W80cm X L140cm ) X 1 Disposable Delivery Sheet With Hole ( 100Cm X 100Cm ) X 1 Disposable Cord Clamp X 1 Disposable Hole Towel For Episiotomy Suturing ( 1 Mtrx ) X 1 For Newborn Baby Disposable Wrapper For Newborn Baby X 1 , Disposable Plastic Gloves Individually Packedmedical Grade Virgin P.V.C. / H.M.H.D.Dotted Excellent Grip Length: Free Size 11 1 / 2 / 29.21 Cm / 292.100Mm Type: Non Sterile / 50 Pcs / 100 Pcs Pack , Chromic Catgut With Needle 3 / 8 Circle Round Body40mm.Size 1 Length 76 Cm , Chromic Catgut With Needle 3 / 8 Circle Round Body40mm.Size 1 / 0 Length 76 Cm , Chromic Catgut With Needle 3 / 8Circle Round Body Heavy Needle 40Mm. Size 1 / 0 Length 100 Cm , Chromic Catgut With Needle 3 / 8Circle Round Body 30Mm. Size 2-0, 76Cm , Synthetic Polyglycolic Acid With Needle ½ Circle Round Body 40Mm. Size 1 , Length 90 Cm , Synthetic Polyglycolic Acid With Needle ½ Circle Round Body40mm. Size 1 / 0 , Length 90 Cm , Synthetic Polyglycolic Acid With Needle ½ Circle Round Body 30Mm. Size 2, Length 90 Cm , Synthetic Polyglycolic Acid With Needle ½ Circle Round Body 30Mm. Size 2 / 0 , Length 90 Cm , X-Ray Devloper Powder To Make Solution Of 22.5Ltr , X-Ray Fixer Powder To Make Solution Of 22.5Ltr , X-Ray Films6.5 X 8.5Green Sensitive Polyester Base Round Corner X-Ray Film Green Sensitive Blue Base With Base Fog Less Than Or Equal To 0.23 & Dmax Not Less Than 3.10 Interleavedthe Density Values Should Be Met At Developer Temperature 32 To 35 Degree = 6.5 X 8.5 , X-Ray Films 8X10green Sensitive Polyester Base Round Corner X-Ray Film Green Sensitive Blue Base With Base Fog Less Than Or Equal To 0.23 & Dmax Not Less Than 3.10 Interleavedthe Density Values Should Be Met At Developer Temperature 32 To 35 Degree = 8 X 10 , X-Ray Films10x12green Sensitivepolyester Base Round Corner X-Ray Film Green Sensitive Blue Base With Base Fog Less Than Or Equal To 0.23 & Dmax Not Less Than 3.10 Interleavedthe Density Values Should Be Met At Developer Temperature 32 To 35 Degree = 10 X 12 , X-Ray Films12x15 Green Sensitivepolyester Base Round Corner X-Ray Film Green Sensitive Blue Base With Base Fog Less Than Or Equal To 0.23 & Dmax Not Less Than 3.10 Interleavedthe Density Values Should Be Met At Developer Temperature 32 To 35 Degree = 12 X 15 , Ecg Jelly Tube Electrode Contact Paste Suitable For Ecg, Eeg, Ect Jar Of200 Gm , Digital X-Ray Film 8 X 10 , Digital X-Ray Film 10 X12 , Digital X-Ray Film11 X 14 , Digital X-Ray Film14 X 17 , Disposable Sterile Cotton Swab Sachet 3Ml Sachet Containingcotton Swab Of Isopropyl Alcohol 50 % By Volume Andrectified Spirit 20% By Volumeor 3 Ml Cotton / Cellulose Swab Of Isopropyl Alcohol 70% V / V , Standard Parameters:Multi Para Monitor Ecg, Spo2, Nibp, Resp And Dual Ibp. High Resolution 10 Inch Color Tft Screen Display Or More Monitor Should Have By Default In-Built Etco2 Module. Optional Changeable Batteries, For Continued Monitoring During Transport Or To Seamlessly Scope With Power Supply Fluctuations.Preferably Main Stream At Most 12 Channels Of Waveforms Display, Various Parameters Waveform Can Be Combined And Switched Over Freely According To Users Demand. Detailed Patient Information, Convenient For Checking Ecg Waveform Review Interface: Ecg Waveform Review, Important Waveform Segment Withdraw For Clinical Judgment, Analysis & Judgment Of Important Information. 7- Lead / 12-Lead Ecg Waveform Displayed In One Screen: Lead Acquisition & Amplification. Rhythm Lead Calculation Can Be Selected Randomly And Synchronous Display On The Screen. List Interface: To Record Nibp, Hr, Pr & Pulse Oxygen Respiration For Clinical Comparison & Observation. Trend Coexistence Interface: Trend Review For 12, 48 And 96 Hours Shall Be Selected. It Captures Different Scopes Of Date Precisely According To Clinical Demand. In Built-Rechargeable Battery Back. Networking Port For Connection To Central Monitoring Station. Voltage 220 Volts. Several Multimedia Connections: Sd Socket, Multiple Usb Sockets & Several Other Ports For External Devices Should Be Iso Certified

Key Value

Document Fees
INR 30000 /-
EMD
INR 500000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail