Rectification Of Pipeline Leakage At Various Rural Water Supply Schemes Under Sub Division Padampur, SriGanganagar-Rajasthan

Public Health Engineering Department-PHED has published Rectification Of Pipeline Leakage At Various Rural Water Supply Schemes Under Sub Division Padampur. Submission Date for this Tender is 28-04-2021. Water Proofing Work Tenders in SriGanganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

27686239
Rectification Of Pipeline Leakage At Various Rural Water Supply Schemes Under Sub Division Padampur
Open Tender
Indian
Rajasthan
SriGanganagar
28-04-2021

Tender Details

Rectification Of Pipeline Leakage At Various Rural Water Supply Schemes Under Sub Division Padampur

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 3 Lakhs /-

BOQ Items

Name of Work: Rectification of Pipeline Leakage at various Rural Water Supply Schemes under Sub Division Padampur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Rectification of Pipeline Leakage BI01010001010000000000000515BI0100001112
2 2 Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth and upto 1.2 Mtr. in length of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) In all type Soil BI01010001010000000000000515BI0100001113
3 3 50/63/75mm BI01010001010000000000000515BI0100001114 1 Each
4 4 80/90mm BI01010001010000000000000515BI0100001115 1 Each
5 5 100/110mm BI01010001010000000000000515BI0100001116 1 Each
6 6 125/140mm BI01010001010000000000000515BI0100001117 1 Each
7 7 150/160/180mm BI01010001010000000000000515BI0100001118 1 Each
8 8 200/225mm BI01010001010000000000000515BI0100001119 1 Each
9 9 250/280mm BI01010001010000000000000515BI0100001120 1 Each
10 10 300/315mm BI01010001010000000000000515BI0100001121 1 Each
11 11 350mm BI01010001010000000000000515BI0100001122 1 Each
12 12 400mm BI01010001010000000000000515BI0100001123 1 Each
13 13 Add on above item for B.T. Road BI01010001010000000000000515BI0100001124 1 Each
14 14 Add on above item for C.C. Road BI01010001010000000000000515BI0100001125 1 Each
15 15 Add on above item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. BI01010001010000000000000515BI0100001126 1 Each
16 16 Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth and more than 1.20 Mtr. in Length of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) In all type Soil AC/PVC/HDPE pipe BI01010001010000000000000515BI0100001127
17 17 50/63/75mm BI01010001010000000000000515BI0100001128 1 Each
18 18 80/90mm BI01010001010000000000000515BI0100001129 1 Each
19 19 100/110mm BI01010001010000000000000515BI0100001130 1 Each
20 20 125/140mm BI01010001010000000000000515BI0100001131 1 Each
21 21 150/160/180mm BI01010001010000000000000515BI0100001132 1 Each
22 22 200/225mm BI01010001010000000000000515BI0100001133 1 Each
23 23 Add on above item for B.T. Road BI01010001010000000000000515BI0100001134 1 Each
24 24 Add on above item for C.C. Road BI01010001010000000000000515BI0100001135 1 Each
25 25 Add on above item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. BI01010001010000000000000515BI0100001136 1 Each
26 26 Washing of polluatted pipe line not more than 100m cutting end and wash it by making an arrangment to draw water away from end with the healp of boosting pump filled on water tanker and after wash the pipe line in its original shape etc complete as per sat BI01010001010000000000000515BI0100001137
27 27 pipe dia 80/90/mm BI01010001010000000000000515BI0100001138 1 Each
28 28 pipe dia 100/110/mm BI01010001010000000000000515BI0100001139 1 Each
29 29 pipe dia 125/140/mm BI01010001010000000000000515BI0100001140 1 Each
30 30 pipe dia 150/160/mm BI01010001010000000000000515BI0100001141 1 Each
31 31 pipe dia 200mm BI01010001010000000000000515BI0100001142 1 Each
32 32 pipe dia 250mm BI01010001010000000000000515BI0100001143 1 Each
33 33 pipe dia 300mm BI01010001010000000000000515BI0100001144 1 Each
34 34 Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour. BI01010001010000000000000515BI0100001145 1 Per Job
35 35 Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size In all type Soil BI01010001010000000000000515BI0100001146
36 36 50 to 75 mm BI01010001010000000000000515BI0100001147 1 Each
37 37 80-110 mm BI01010001010000000000000515BI0100001148 1 Each
38 38 125 to 165 mm BI01010001010000000000000515BI0100001149 1 Each
39 39 200 to 300 mm BI01010001010000000000000515BI0100001150 1 Each
40 40 Add on above item for B.T. Road BI01010001010000000000000515BI0100001151 1 Each
41 41 Add on above item for CC Road BI01010001010000000000000515BI0100001152 1 Each
42 42 Add on above item if depth of pipe line is above 1.5 mtr and up to 3.0 mtr. BI01010001010000000000000515BI0100001153 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail