Public Health Engineering Department-PHED has published Rectification Of Pipeline Leakage At Various Rural Water Supply Schemes Under Sub Division Padampur. Submission Date for this Tender is 28-04-2021. Water Proofing Work Tenders in SriGanganagar Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Rectification of Pipeline Leakage at various Rural Water Supply Schemes under Sub Division Padampur | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Rectification of Pipeline Leakage | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | Minor repair of leakages such as lead caulking, plugging, clamping and ring fixing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth and upto 1.2 Mtr. in length of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) In all type Soil | BI01010001010000000000000515BI0100001113 | ||
3 | 3 | 50/63/75mm | BI01010001010000000000000515BI0100001114 | 1 | Each |
4 | 4 | 80/90mm | BI01010001010000000000000515BI0100001115 | 1 | Each |
5 | 5 | 100/110mm | BI01010001010000000000000515BI0100001116 | 1 | Each |
6 | 6 | 125/140mm | BI01010001010000000000000515BI0100001117 | 1 | Each |
7 | 7 | 150/160/180mm | BI01010001010000000000000515BI0100001118 | 1 | Each |
8 | 8 | 200/225mm | BI01010001010000000000000515BI0100001119 | 1 | Each |
9 | 9 | 250/280mm | BI01010001010000000000000515BI0100001120 | 1 | Each |
10 | 10 | 300/315mm | BI01010001010000000000000515BI0100001121 | 1 | Each |
11 | 11 | 350mm | BI01010001010000000000000515BI0100001122 | 1 | Each |
12 | 12 | 400mm | BI01010001010000000000000515BI0100001123 | 1 | Each |
13 | 13 | Add on above item for B.T. Road | BI01010001010000000000000515BI0100001124 | 1 | Each |
14 | 14 | Add on above item for C.C. Road | BI01010001010000000000000515BI0100001125 | 1 | Each |
15 | 15 | Add on above item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. | BI01010001010000000000000515BI0100001126 | 1 | Each |
16 | 16 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth and more than 1.20 Mtr. in Length of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material to make repair leak proof and then refill the pit from excavated sand by ramming it at sides of pipe & upto ground level for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) In all type Soil AC/PVC/HDPE pipe | BI01010001010000000000000515BI0100001127 | ||
17 | 17 | 50/63/75mm | BI01010001010000000000000515BI0100001128 | 1 | Each |
18 | 18 | 80/90mm | BI01010001010000000000000515BI0100001129 | 1 | Each |
19 | 19 | 100/110mm | BI01010001010000000000000515BI0100001130 | 1 | Each |
20 | 20 | 125/140mm | BI01010001010000000000000515BI0100001131 | 1 | Each |
21 | 21 | 150/160/180mm | BI01010001010000000000000515BI0100001132 | 1 | Each |
22 | 22 | 200/225mm | BI01010001010000000000000515BI0100001133 | 1 | Each |
23 | 23 | Add on above item for B.T. Road | BI01010001010000000000000515BI0100001134 | 1 | Each |
24 | 24 | Add on above item for C.C. Road | BI01010001010000000000000515BI0100001135 | 1 | Each |
25 | 25 | Add on above item if depth of pipeline is above 1.5 mtr and up to 3.0 mtr. | BI01010001010000000000000515BI0100001136 | 1 | Each |
26 | 26 | Washing of polluatted pipe line not more than 100m cutting end and wash it by making an arrangment to draw water away from end with the healp of boosting pump filled on water tanker and after wash the pipe line in its original shape etc complete as per sat | BI01010001010000000000000515BI0100001137 | ||
27 | 27 | pipe dia 80/90/mm | BI01010001010000000000000515BI0100001138 | 1 | Each |
28 | 28 | pipe dia 100/110/mm | BI01010001010000000000000515BI0100001139 | 1 | Each |
29 | 29 | pipe dia 125/140/mm | BI01010001010000000000000515BI0100001140 | 1 | Each |
30 | 30 | pipe dia 150/160/mm | BI01010001010000000000000515BI0100001141 | 1 | Each |
31 | 31 | pipe dia 200mm | BI01010001010000000000000515BI0100001142 | 1 | Each |
32 | 32 | pipe dia 250mm | BI01010001010000000000000515BI0100001143 | 1 | Each |
33 | 33 | pipe dia 300mm | BI01010001010000000000000515BI0100001144 | 1 | Each |
34 | 34 | Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree refill the pit from excavated sand by ramming it & upto ground level for entire job contractor will use his own T&P & labour. | BI01010001010000000000000515BI0100001145 | 1 | Per Job |
35 | 35 | Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling the pit from excavated sand by ramming it at site of pipe upto ground level. The rate includes all labour charges to complete the work for pipe size In all type Soil | BI01010001010000000000000515BI0100001146 | ||
36 | 36 | 50 to 75 mm | BI01010001010000000000000515BI0100001147 | 1 | Each |
37 | 37 | 80-110 mm | BI01010001010000000000000515BI0100001148 | 1 | Each |
38 | 38 | 125 to 165 mm | BI01010001010000000000000515BI0100001149 | 1 | Each |
39 | 39 | 200 to 300 mm | BI01010001010000000000000515BI0100001150 | 1 | Each |
40 | 40 | Add on above item for B.T. Road | BI01010001010000000000000515BI0100001151 | 1 | Each |
41 | 41 | Add on above item for CC Road | BI01010001010000000000000515BI0100001152 | 1 | Each |
42 | 42 | Add on above item if depth of pipe line is above 1.5 mtr and up to 3.0 mtr. | BI01010001010000000000000515BI0100001153 | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy