Power Development Department has published Supply Installation Testing And Commissioning Of Equipment S Required For Construction Of 10Mva 33/11Kv Receiving Station At Redwani Under Capex Budget .. Submission Date for this Tender is 03-05-2021. Power Relays Tenders in Redwani kul Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: Supply,Installation,Testing & Commissioning of Equipments required for Construction of 10MVA,33/11KV Receiving Station at Redwani under Capex Budget. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | 33/11KV, 10 MVA ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections | item1 | 1 | No |
2 | 2 | 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) | item2 | 2 | No |
3 | 3 | 33 kV C&R Panel with nemurical Relays with Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant( with out Differential Relay) | item3 | 1 | No |
4 | 4 | 33 kV C&R Panel with nemurical Relays with Differential Relay ( IEC 61850), Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant | item4 | 1 | No |
5 | 5 | 33 kV Isolator with Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) | item5 | 2 | Set |
6 | 6 | 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) | item6 | 2 | Set |
7 | 7 | 33 kV Current Transformer (250-500/5-5 A) (33 kV, 1F, Multi Ratio Multi Core, Outdoor) (1 No. per F) | item7 | 6 | No |
8 | 8 | 33 kV Voltage Transformer (33 kV/110 V, 1F, Multi-Core, Outdoor), (1No. per F) | item8 | 3 | No |
9 | 9 | 30 kV Lightening Arrestors (30 kV, 10KA, Station class, ZnO, Porcelain/Polymer) gap less | item9 | 6 | No |
10 | 10 | 33 kV Post Insulator (Polymer/Porcelain 36KV, 170KV Impulse) | item10 | 6 | No |
11 | 11 | Galvanised Steel Structures(6" G I Pipe with Top & Base/Channel/Angle/Flat) as per REC | item11 | 9 | MT |
12 | 12 | Galvanised Nuts & Bolts | item12 | 0.45 | MT |
13 | 13 | M S Chequred Plate 6 mm Thick for cable trunch & Equipments | item13 | 55 | Sq Mt |
14 | 14 | 12 Core 2.5 mm² Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS. | item14 | 240 | Mtr |
15 | 15 | 6 Core 2.5 mm² Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS. | item15 | 420 | Mtr |
16 | 16 | 4 Core 2.5 mm² Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS. | item16 | 300 | Mtr |
17 | 17 | 2 Core 2.5 mm² Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS. | item17 | 360 | Mtr |
18 | 18 | Lugs, Ferrules etc. | item18 | 2 | lot |
19 | 19 | Al Clamps of Sizes | item19 | 27 | Nos. |
20 | 20 | Single Tension Fittings | item20 | 12 | Nos. |
21 | 21 | Disc Insulators (Porcelain/Polymer ) 70 KN | item21 | 36 | Nos. |
22 | 22 | Earth wire 7/4.00 mm sq. | item22 | 58 | Kg |
23 | 23 | Almunium Tubular Bus Bar( Outer Dia=48.26mm; Inner Dia=40.894mm) | item23 | 288 | Rft |
24 | 24 | ACSR Conductor Panther | item24 | 200 | Mtr |
25 | 25 | G I flat for earthing(50x6)mm | item25 | 300 | Kg |
26 | 26 | 11 kV VCB Panel Board 12 kV, 1250A, 25 KA, Outdoor (1 incomming +5 Outgoing) Indoor Type | item26 | 1 | Set |
27 | 27 | 11 kV L.A Station Type ;9KV,10KA | item27 | 5 | Set |
28 | 28 | 11 KV 630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS | item28 | 160 | Mtr |
29 | 29 | 11 KV 3-Core XLPE 300 mm² armoured, FRLS | item29 | 240 | Mtr |
30 | 30 | 11 KV 3-Core XLPE 120 mm² armoured, FRLS | item30 | 60 | Mtr |
31 | 31 | 11 kV Heat Shrinkable Cable Termination Kits for 630 mm² Single Core XLPE Cable Indoor and Out door Type | item31 | 4 | Set |
32 | 32 | 11 kV Heat Shrinkable Cable Termination Kits for 3-Core XLPE 300 mm² Indoor and Out door Type | item32 | 4 | Set |
33 | 33 | 11 kV Heat Shrinkable Cable Termination Kits for 3-Core XLPE120 mm² Indoor and Out door Type | item33 | 1 | Set |
34 | 34 | 11kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. | item34 | 4 | Set |
35 | 35 | 9 Mtr. Long Pole(ST-410 SP33) along with cement concrete Bottoming in 1:2:4 as per REC Std & Earthing Complete | item35 | 10 | Nos |
36 | 36 | 11 KV GO AB Switch , 3-Pole,3 Pole, 400 Amp | item36 | 1 | No |
37 | 37 | Galvanised iron of sorts for Auxillary Sub Station | item37 | 360 | kg |
38 | 38 | 100 KVA, 11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) | item38 | 1 | No |
39 | 39 | 120 mm² ,Almunium,PVC LT Cable 4 Core, armoured, FRLS | item39 | 45 | Mtr |
40 | 40 | Earthing of 100 KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | item40 | 1 | Job |
41 | 41 | MCCB - 200 Amps | item41 | 1 | No |
42 | 42 | Yard Lighting of the new receiving sub station using 4 no , 9 meter long, GI High Mast poles ,continuously tapered of octagonal of cross-section ; including suitable shallow raft foundation using 8 nos 250 W each LED flood light , conforming to IP-66 complete with all accessories bearing Philips make and suitable control feeder panel. | item42 | 1 | Job |
43 | 43 | a). Battery Bank 30 V,200 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. Lead acid Type.\n\nb). 36V,200 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . | item43 | 1 | No |
44 | 44 | Distribution Panel (36V, DC) with 1 No.10Amp. MCCB. Double pole for battery incoming supply with DP MCBs & indicating Lamps etc. | item44 | 1 | No. |
45 | 45 | Distribution Panel (415 V, AC) complete with ckt. Breakers, indicating Lamps etc. | item45 | 1 | No. |
46 | 46 | Fire Fighting Equipment consisting of \na). Dry chemical powder type(6kg) for control room....3No. \nb). Co2 Type of 4.5 kg capacity for control room ---4 No. \nc). Co2 Type Trolly mounted of 22.5 Kg capacity for switch yard.. 2 No. | item46 | 1 | Job |
47 | 47 | 12 KV ,3.6 MVAR, Capacitor Bank with VCB Panel with complete arrancement for conection with 11 KV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories | item47 | 1 | Set |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail