| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Carriage of material by mechanical transport includeing, loading, unloading and stackingUpto 2 Km. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 7 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 9 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights:Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 13 | Edges of slabs and breaks in floors and walls Under 20 cms wide |
| 14 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 16 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.50mm thick |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 20 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level |
| 21 | All works above plinth level upto floor V level |
| 22 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 26 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 27 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 28 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 29 | Extra for providing and mixing water proofing material in cement concrete per 50 kg work in doses by weight of cement as per manufacturer\"s specification. |
| 30 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm |
| 31 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 32 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 33 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 34 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws |
| 36 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 37 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 38 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shuttersKiln seasoned and chemically treated hollock wood |
| 39 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P.brass screws and wooden plugs, etc., wherever necessary complete 25 mm dia |
| 40 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 41 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 42 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.250 mm weighing not less than 150 gms |
| 43 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 44 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm |
| 45 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 46 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.5 mm thick |
| 47 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.With decorative veneering on one side and commercial veneering on other side |
| 48 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces |
| 49 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 50 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 51 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 52 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dashsteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 53 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 54 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 55 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick. |
| 56 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 57 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 58 | Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. |
| 59 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 61 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 62 | 12 mm cement plaster of mix1:6 (1 cement: 6 coarse sand) |
| 63 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 64 | 6mm cement plaster of mix1:3 (1 cement : 3 fine sand) |
| 65 | White washing with lime to give an even shade :New work (three or more coats) |
| 66 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 67 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 68 | Finishing walls with Premium Acrylic Smooth exterior paint withSilicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 69 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 70 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 71 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 72 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 73 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 74 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 75 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 76 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete450 mm dia RCC pipes. |
| 77 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 78 | Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 79 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness |
| 80 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With brass cover plate minimum 1.25 mm thickness |
| 81 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 82 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 83 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.iv) Vth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). |
| 84 | Providing and laying 1st quality ceramic glazed Anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to IS:15622 in all colours, shades, sizes as approved over 20 mm thick bed of Cement Mortar 1: 4 (1 cement : 4 Coarse Sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per drawings and as directed by the Engineer in Charge. |
| 85 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. all complete as directed and specified by the Engineer-in-Charge :150 mm |
| 86 | Providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the Engineer-in-Charge : |
| 87 | Providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the Engineer in Charge. |
| 88 | Supplying, installation and testing of 13 (thirteen) passenger capacity elevator of OTIS Elevator Company Limited having the folowing specification :-Speed - 1MPSTravel - Ground floor to second floor about 10.80 metersStop & Opening - 3 stops with all opening on the same side. Stainless steel car, car door, landing door including all necessary accessories complete in all respect. |
| 89 | Plumbing & Sanitary |
| 90 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 91 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc, not exceeding 80 mm dia. |
| 92 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 93 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 94 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 95 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm |
| 96 | Bend 87.5°110 mm bend |
| 97 | Shoe (Plain)110 mm Shoe |
| 98 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 99 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 100 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 101 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 102 | Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 103 | Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. |
| 104 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 105 | Providing and fixing toilet paper holder :Vitreous china |
| 106 | Providing and fixing soil, waste and vent pipes :100 mm dia.Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 107 | 75mm diameterCentrifugally cast (spun) iron socketed pipe as per IS: 3989 |
| 108 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia. pipe |
| 109 | For 75 mm dia. pipe |
| 110 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm Sand cast iron S&S as per IS - 3989 |
| 111 | 75 mm Sand cast iron S&S as per IS- 3989 |
| 112 | Providing and fixing plain bend of required degree.100 mm Sand cast iron S&S as per IS - 3989 |
| 113 | 75 mm Sand cast iron S&S as per IS- 3989 |
| 114 | Providing and fixing heel rest sanitary bend100 mmdiaSand cast iron S&S as per IS - 3989 |
| 115 | 75 mm Sand cast iron S&S as per IS- 3989 |
| 116 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 100x100x100mmSand cast iron S&S as per IS - 3989 |
| 117 | 75x75x75mmSand cast iron S&S as per IS - 3989 |
| 118 | Providing and fixing single equal plain junction of required degree100x100x100mmSand cast iron S&S as per IS - 3989 |
| 119 | 75x75x75mmSand cast iron S&S as per IS - 3989 |
| 120 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :100mmSand cast iron S&S as per IS - 3989 |
| 121 | 75mmSand cast iron S&S as per IS - 3989 |
| 122 | Providing and fixing terminal guard :100mmSand cast iron S&S as per IS - 3989 |
| 123 | 75mmSand cast iron S&S as per IS - 3989 |
| 124 | Providing and fixing collar :100mmSand cast iron S&S as per IS - 3989 |
| 125 | 75mmSand cast iron S&S as per IS - 3989 |
| 126 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100mm |
| 127 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :100mm |
| 128 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletSand Cast Iron S&S as per IS: 1729 |
| 129 | Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :100 mm dia |
| 130 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :100 mm diameter pipe |
| 131 | 75mm diameter pipe |
| 132 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 133 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms |
| 134 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 135 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 136 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching & refilling.External work 32mmdia nominal bore |
| 137 | 40mmdia nominal bore |
| 138 | 50mmdia nominal bore |
| 139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia Pipes metre |
| 140 | 32 mm nominal outer dia Pipes metre |
| 141 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes |
| 142 | 20 mm nominal outer dia Pipes |
| 143 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore |
| 144 | Providing and fixing brass stop cock of approved quality:15 mm nominal bore |
| 145 | 20 mm nominal bore |
| 146 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25mm nominal bore |
| 147 | 32mm nominal bore |
| 148 | 40mm nominal bore |
| 149 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore |
| 150 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :25 mm nominal bore |
| 151 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore |
| 152 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter |
| 153 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Rectangular tank |
| 154 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 155 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 156 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore. |
| 157 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore. |
| 158 | Providing and fixing PTMT grating of approved quality and colour.Circular type.100 mm nominal dia. |
| 159 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 160 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm diameter |
| 161 | 150 mm diameter |
| 162 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter |
| 163 | 150 mm diameter |
| 164 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design:150 x 100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 165 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 166 | Extra for depth for manholes :Size 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 167 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 168 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 169 | Providing, laying and jointing non pressure NP2 class (light duty)RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia RCC pipe |
| 170 | 250 mm dia RCC pipe |
| 171 | Providing and fixing floor drain points of 75 x 50mmreducer bend with 100 mm dia CP grating with frame, embedded in floor including making joints with waste pipe etc. complete in all respects as per drawing and as directed by theEngineer in Charge. |
| 172 | Providing & fixing Sink Mixer with Swinging Casted Spout (Wall Mounted Jaquar model CON-309 KN)/approved equal with 450mm long copper pipes & brass nuts. |
| 173 | Providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model No.(F360019CP) respectively or equivalent approved make as approved byEngineer in charge. |
| 174 | Supplying, fixing, testing and commissioning of storage type water heater (Geyser) etc. with Stainless steel body , copper container , automatic thermostatic control electric element, pressure release valve, M.S. nuts and bolts etc. conforming to IS: 2082 |
| 175 | Electricals |
| 176 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 177 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulatedcopperconductorsinglecorecableinsurface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 178 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copperconductorsinglecorecableinsurface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 179 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 180 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 181 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 182 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 183 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 184 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 mm X 75 mm X 60 mm deep |
| 185 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 186 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module (75 mmX75 mm) |
| 187 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 188 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 189 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 190 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 191 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 192 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door |
| 193 | 8 way (4 + 24), Double door |
| 194 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 195 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40A |
| 196 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40A |
| 197 | Fabrication, supplying, installation, testing and commissioning of indoor type panel, IP-42 cubical type panel suitable for 415 volt, 3 phase, 4 wire, 50 Hz AC supply, compartmentalized of depth not less than 300 mm made of 2 mm thickCRCA sheet steel, cleaning, processing, & finishing complete with 7/8 tank process for powder coating in approved shade of welded construction with necessary stiffner,suitable compartments for mounting of switch gear and and other acessories with hinged type door at front side with locking arrangement, with 200 amps capacity4 strips aluminium bus bar of high conductivity with DMC/SMC bus bar support, connection and inter connection of switch gears, proper gasketing adequate ventilation arrangement, entire panel shall have a common aluminium earth bar of size 30mm x 5mm at the rear,control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor S/C cable, cable alleys, individual cable gland plate (3mm thick), terminal block for incoming and each outgoing,and fixed on 35mmX35mmX5mm angle iron frame work leg including supplying and fixing of the following switchgear, accessories as reqd. (General arrangement and schematic diagram to be approved by the department before start of fabrication.)(Note : MCCB lcs=100% Icu) (For Building No-2)a) 200 Amp FP MCCB (36KA)(Incoming) ( Legrand/ L&T/ CG/Havells) - 1 No.b) 63Amp FP MCCB (16KA)(outgoing) ( Legrand/ L&T/ CG/Havells) - 6 Noc) 40 Amp FP MCCB (16KA)(outgoing) ( Legrand/ L&T/ CG/Havells) -3 Nos.d) 0 - 200 Amps CT operated digitalAmmeter (96mmX96mm) with in-built selector switch (L& T/AE- make) alongwith cast resin 200/5A CT of 15 VA burden accuracy class-1 with 3 Nos 2A (10KA) SP MCB - 1Sete) 0 - 500 Volts (96mmX96mm)digital Voltmeter with in-built selector switch with 3 Nos. 2A (10 KA) SP MCB - 1 set(L & T /AE)f) Phase Indication LED lamp for each phaseswith 3 Nos. 2A (10KA) SP MCB - 1 set |
| 198 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 199 | Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 200 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) |
| 201 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 202 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 203 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 204 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 205 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chucknuts and spring washers etc. complete as required. |
| 206 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.Upto 35 sq. mm |
| 207 | Above 35 sq. mm and upto 95 sq. Mm |
| 208 | Above 95 sq. mm and upto 185 sq. Mm |
| 209 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 210 | Supplying and fixing 5 watt surface mounted LED fitting with aesthetically designed flat panel which provides soft-light and glare free symmetrical illumination including connections using 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd. (Make : Bajaj / Havells/ Crompton -or equivalent make of Wipro/Philips.) |
| 211 | Supplying, Installation, testing and commissioning of 1 x 18 watt box type LED Tube Light Fitting with one No. 18 W LED Tube, complete with all accessories and tube etc. Directly on ceiling / wall, i/c connections with 1.5 sq. Mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as reqd. (Make : Bajaj /Havells/Phillips / Wipro) |
| 212 | Supplying ,installation & testing of6/10 Wattround surface down light mounted LED luminaire with white powder coated polycarbonate housing and pressure die-cast heat sink, fixing dirrectlyon ceiling i/c connection etc.as required.(Make Havells/ Bajaj / philips) |
| 213 | Supplying, Installation, testing and commissioning of 9 watt LED wall mountingenergy efficient mirror light fitting with 9 watt LED tube suitable for 230 volts,50 Hz AC supplywiringwith 1.5 sq.mm. FRLS PVC insulated copper conductor, single core cable and earthing etc. as reqd. (Make : Havell\"s/Cromptonor similar to Bajaj/ Wipro / Philips ) |
| 214 | Supplying ,installation & testing of24 Watt600X600mm surface down light mounted LED luminaire with white powder coated polycarbonate housing and pressure die-cast heat sink, fixing dirrectlyon ceiling i/c connection etc.as required.(Make Havells/ Bajaj / philips) |
| 215 | Supply, installation, testing & commissioning of Ceiling fan, 1200 mm sweep, Energy 5 Star complete with capacitor, canopy and down rod including electronic step regulator modular type 5 step 2 module with provision from ceiling rose/connector to fan and regulator all as specified as required. (Make Havells/ Bajaj / philips ) |
| 216 | Supply, installation, testing & commissioning of Exhaust fan 300 mm dia; 900 rpm complete with louvers and provision of cable from ceiling rose/connector to fan all as specified as per HAVELLS Turbo Force or equivalent. |
| 217 | Providing & fixing of 45 watt LED type street light luminaire of pressure die cast housingwith toughenedglass and individual LEDs with secondary optics and IP 66 protection suitable for operating on 140 - 280 Volt. Single phase, 50 Hz Ac supplycomplete with driver circuit, 45 watt LED fitting on the existing pole i/c making connections, testing, commissioning etc as reqd. (Make : Bajaj - BRTFG 45W LED I (169799) / Havells / Crompton Greaves) |
| 218 | Fabrication, supplying, installation, testing and commissioning of indoor type panel,degree of protectionIP-42 suitable for 415 volt, 3 phase, 4 wire, 50 Hz AC supply, compartmentalized of depth not less than 300 mm made of 2 mm thickCRCA sheet steel, cleaning, processing, & finishing complete with 7/8 tank process for powder coating in approved shade of welded construction with necessary stiffner,suitable compartments for mounting of switch gear and and other acessories with hinged type door at front side with locking arrangement, with 200 amps capacity4 strips aluminium bus bar of high conductivity with heat shrinkable coloured sleeves i/c DMC/SMC bus bar support, connection and inter connection of switch gears, proper gasketing adequate ventilation arrangement, entire panel shall have a common aluminium earth bar of size 30mm x 5mm at the rear,control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor S/C cable, cable alleys, individual cable gland plate (3mm thick), terminal block for incoming and each outgoing, bottom base channel and leg support with 35mmX35mmX5mm angle iron frame work including supplying and fixing of the following switchgear, accessories etc as reqd. (General arrangement and schematic diagram to be approved by the department before start of fabrication.) (For Building No-1)Incoming :a) 100 Amp FP MCCB having breaking capacity (36KA) thermal magnetic release (Ics=100% Icu)( Make : Legrand/ L&T/ CG/Havells) - 1 No.Outgoing :a) 63Amp FP MCCB having breaking capacity (16KA) thermal magnetic release type (Ics=100% Icu) ( Legrand/ L&T/Havells) -2Nos.b) 63 Amps 4 pole ML contactor. (Make : L & T Legrand/Havells)c) Analog Time switch of 24 hours = 1 No (Make: L & T/Legrand)Metering :a)3 Phase (0-500) V (96mmX96mm)digital Voltmeter with in-built selector switch along with 3 Nos. 2A (10 KA) SP MCB (L&T/AE/Kaycee) = 1 No. b) 3 Phase, 0-100 A CT operated digitalAmmeter (96mmX96mm) with in-built selector switchalongwith 3 Nos. 2A (10 KA) SP MCB (L&T/AE/kaycee) = 1 No.c) LED type indicator lamp RYB , protectionwith 3 Nos. 2A (10KA) SP MCBs = 1 setd)100/5A CT cast resin of 15 VA burden accuracy class-1 (Make: L&T/AE/Kaycee) = 1 Set |
| 219 | Supplying of following size ISI marked XLPE insulated and PVC sheathed aluminium conductor armoured U.G. cable of 1.1 KV grade conforming to IS 7098(Part 1) 1988 andammended up to date as reqd. (Make : Polycab/Havell\"s)a) 4 core 25 Sqm |
| 220 | b) 3.5 Core 95 Sqm |
| 221 | c) 3.5 Core 185 Sqm |
| 222 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fitting including trenching (75 cm deep) and re-filling etc as required.a)80 mm dia ( to facilate entryof service connection cable) |
| 223 | b)100 mm dia ( to facilate entryof service connection cable) |
| 224 | Suplying & errection of hot dipped galvanised 6.0 mtr. Height octogonal pole with 1.0 mtr. Long (approx) single sided GI bracket in approved design capable of holding of luminaire. The pole structure design shall be as per ILE TR7 considering the wind speed as per IS:875, the HT steel for construction should be as per BSEN10025 grade S3355JO, hot dip galvanised on both internal and external surfaces as per IS 2629/IS 2633/IS 4759 with average coating thickness of 70 microns through a single diping process. The pole shall also be provided with hinged / clained flush door of suitable length at an suitable from the base plate with proper strengthening to the cutout of the door opening. Each pole shall be complete with a Bakelite sheet complete with DIN rail, 10 amps, 10 KA DP MCB, screwless DIN mounting connectors suitable for 16 sq.mm. terminations complete with DIN bar, shorting links, end locks etc. as reqd. (Wago / Pheonix : Make) and 3 x 2.5 sq.mm. FRLS PVC insulated multistranded copper conductor cable from junction boc to the luminaire complete i/c terminations with insulated copper lugs etc. as reqd. The pole shall be with 200mm x 200m x 12mm GI base plate, 600 mm long \"J\" type GI foundation bolts of min. 20 mm dia each with 3 GI nuts and 2 GI washers (EN.8 grade) etc. complete as per drawing. The pole shall have a minimum OAF of 130 mm at bottom and 70 mm at top. The pole shall have a minimum section thickness of 3 mm. The pole shall be fabricated in a single section. The pole shall have a single side GI bracket to give a aesthetic apparance as per the design approved by the engineer-in-charge. The installation shall include making RCC foundation (Foundation design & drawing must be approved be Engineer-in-Charge). (Approved Make : Bajaj / Volmunt / Utkarsh/Nezone) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender