Project Description

Urgent Renovation Of Office Building Of Directorate Of Health Services Urgent Renovation Of Office Building Of Directorate Of Health Services

BOQ

Name of Work:Urgent renovationof office building of Directorate of Health Services (1st floor ) at P.N. Complex, Gurkhabasti during the year 2021-22 due to sudden damage caused by fire accident/ SH:- Flooring, Installation of false ceiling, Aluminium work, wood work, Finishing work, wall panelling with ACP sheet,water supply & sanitation, & minor internal electrification etc.
Sl. No. Item Description
1Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
2Dismantling doors, windows and clerestorywindows (steel or wood) shutter includingchowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sqm and below.
3Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in charge.
4Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge: With cement mortar 1:4 ( 1 cement : 4 fine sand )
5Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size)
6Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge
7Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. Complete
8Providing and applying cement slurry on old CC / RCC / Brick works in joints to receive new and fresh CC / RCC / Brick works including roughening and cleaning the old surface as required complete as per direction of the Engineer in charge.
9Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and as per direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
1012 mm cement plaster of mix:-Cement mortar 1:4 (1 cement : 4 fine sand)
1115 mm cement plaster on the rough side of single or half brick wall of mix:- Cement mortar 1:4 (1 cement : 4 fine sand)
126 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand)
13Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Local Teak Wood
14Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant ................Aluminium Composite Panels of 4mm total thickness withTop coil – 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 3mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119- 16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS 737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 7.5 Kg/m2
15Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanizedwith zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings,specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I.
16Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : Local Teak Wood
17Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
18Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete:-Soluble Salt Stainfree vitrified tiles: Size of tile 60x60 cm
19Deduet for not using 20mm thick cement mortar 1:4 (1cement : 4 fine sand ) bedding in laying of floor tiles.
20Fixing glazed/Ceramic/Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, using 5kg. adhesive per sqm of tile area, in average 3mm thickness.
21Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.Mat Finish Tiles Ceramic Tiles 1st quality 300 x 300mm in all shades and designs
22Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.
23Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
24Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. Complete300×16 mm
25Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm
26Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
27Providingandfixingaluminiumworkfordoors, windows, ventilators and partitions withextrudedbuilt up standardtubularsections/ appropriateZsectionsand other sections of approved make conforming to IS:733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing andthedirectionofEngineer­in­charge.(Glazing and paneling and dash fasteners to be paid for separately) :- A. For fixed portion of approved quality:Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
28Providingandfixingaluminiumworkfordoors, windows, ventilators and partitions withextrudedbuilt up standardtubularsections/ appropriateZsectionsand other sections of approved make conforming to IS:733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing andthedirectionofEngineer­in­charge.(Glazing and paneling and dash fasteners to be paid for separately) :- B. For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
29Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of Grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge (only weight of grill to be measured for payment).
30Providing and fixing glazing of approved quality in aluminum doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-A. With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm )
31Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade-I, type II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass / stainless steel screws all complete as per architectural drawing and the direction of Engineer-in-charge :- Prelaminated particle board of approved quality with decorative lamination on both side.
32Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.
33Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete
34Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work
35Providing and laying and fixing of 2.00 mm thick antistatic sheet of required shade on C.C. Floor, wall with adhesive etc complete of ISI quality complete as per direction of the Engineer-in-charge.
36Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
37Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer.
38Distempering with oil bound washable distemper of approved brand and manufacture and of required shade on old work ( one or more coats ), to give an even shade as required complete as per direction of the Engineer in charge.
39Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge.
40Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe40 mm dia
41Providing and fixing PTMT Waste Coupling for washbasin and sink, of approved quality and colour. Waste coupling 38mm of 83mm length and 77mm breadth, weighing not less than 60gms.
42Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
43Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (a) 15 mm nominal outer dia .Pipes
44Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(b) 20 mm nominal outer dia .Pipes
45Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
46Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore.
47Supplying & fixing of following ratings isolator in the existing MCB DB including connection etc as required:-63 amps TP isolator:-
48Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required.(a). Short Point
49Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required.(b). Medium Point
50Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required.(c) Long point
51Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) onmodular concealedswitch board with cover plate earthing the 3rd pin etc. as required.
52Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required:- 2 X 1.5 + 1 X 1.5 sq mm
53Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.(i) 1-2 module :-
54Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.(b). 6 modules
55Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.(c). 8 modules
56Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.(d). 12 modules
57Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.(i) 1-2 module plastic switch board:-
58Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.ii.6 modules plastic switch board
59Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.iii.8 modules plastic switch board
60Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.iv.12 modules plastic switch board
61Supplyingof 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades.(Without regulator) conformimgto IS 374 (1979), BEE 5star
62Supplying & fixing of electronic 5 step fan regulator in existing switch board including necessary connection etc as required:-
63Supplying & fixing of following ratings MCBB/C curve having breaking capacity10 KA in the existing MCB DB including connectionas required:-6 to 32 amps SP MCB:-
64Supplying and fixing of following accessories for LED luminaries including necessary connection etc. as required:-16-18 watt LED tube light :-
65Supplying and fixing of following surface/recess mounting LED luminaries complete with powder coated die cast housing and high efficiency diffuser including necessary connection etc. as required:-12-18 watt (round/square shaped) LED light fixture:-
66Supplying and fixing of the following modular accessories including necessary connection etc. as required.20/25 amps single phase motor starter switch (2M):-
67Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC conduit including connection etc. as required:-3 X 4 sq mm

AI Tender Summary

OUR REF NO 27657701
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 27-04-2021
Authority
Authority Name State Health And Family Welfare Deptt
Work Description Urgent Renovation Of Office Building Of Directorate Of Health Services Urgent Renovation Of Office Building Of Directorate Of Health Services
Basic Detail
Tender No EE(Engg.Cell)/DHS/DNIT/01/2021 22
Bidding Type Tender
Location
City Tripura
State Tripura
Key Dates
Publish Date 13 Apr 2021
Submission Date 27 Apr 2021
Open Date 27 Apr 2021
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 14560
Exemption Not Available
Document List
d01ea504-ddf2-482f-a8b0-0e122032b5da.html
BOQ_17823.xls
DNIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 13, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 27, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 27, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d01ea504-ddf2-482f-a8b0-0e122032b5da.html

xls

BOQ_17823.xls

pdf

DNIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender