Provision Of Stand By Oh Ht Line From Power House To 181 Mh Special Repair Replacement Of 4 Core 25 Sqmm Xlpe Cable Length 400 Metre Alongwith Distribution Box And 4 Pole Mccb From 100 Kva Mes Transformer To Single Offrsaccn At Certain Location Under G , GE 859 EWS-Arunachal Pradesh

Military Engineer Services-MES has published Provision Of Stand By Oh Ht Line From Power House To 181 Mh Special Repair Replacement Of 4 Core 25 Sqmm Xlpe Cable Length 400 Metre Alongwith Distribution Box And 4 Pole Mccb From 100 Kva Mes Transformer To Single Offrsaccn At Certain Location Under G . Submission Date for this Tender is 15-05-2021. MCCB Tenders in GE 859 EWS Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27657016
Corrigendum : Provision Of Stand By Oh Ht Line From Power House To 181 Mh Special Repair Replacement Of 4 Core 25 Sqmm Xlpe Cable Length 400 Metre Alongwith Distribution Box And 4 Pole Mccb From 100 Kva Mes Transformer To Single Offrsaccn At Certain Location Under G
Open Tender
Indian
Arunachal Pradesh
GE 859 EWS
15-05-2021

Tender Details

Provision Of Stand By Oh Ht Line From Power House To 181 Mh Special Repair Replacement Of 4 Core 25 Sqmm Xlpe Cable Length 400 Metre Alongwith Distribution Box And 4 Pole Mccb From 100 Kva Mes Transformer To Single Offrsaccn At Certain Location Under G Provn Of Stand By Oh Ht Line From Power House To 181 Mh Special Repair Replacement Of 4 Core , 25 Sqmm Xlpe Cable Length 400 Metre Alongwith Distribution Box And 4 Pole Mccb From 100 Kva Mes Transformer To Single Offrs Accn At Certain Location Unde

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Apr-2021 DATE CORRIGENDUM Date 08-05-2021
2 05-May-2021 OTHER Other 08-05-2021
3 08-May-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-05-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 21500.0 /-
Tender Value
INR 10.70 Lakhs /-

BOQ Items

Nature of Work : Provn of stand by OH HT line from power house to 181 MH & special repair/replacement of 4 core, 25 Sqmm XLPE cable length 400 mtre alongwith distribution box and 4 pole MCCB from 100 KVA MES Transformer to single offrs Accn at certain location under GE 859 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for Steel tubular swaged poles 11.0 metres long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 complete all as specified and directed.\nMake : National Tubing Company/Kwality Steel Kolkata/Calcutta Poles/ Bansal Poles/Jindal Poles 10 Each
2 2 Supplying, laying, jointing, testing and commisioning HT 11 KV (E) XLPE cable, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 3 core & cross section area 95 Sqmm laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed. Make : Havells/Finolex/Polycab/Gloster \nNote :-Payment for excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be made for separately under relevant item of Scedule 'A'. 30 RM
3 3 M&L for ACSR conductor fixed on poles without kinds and bends complete all as specified and directed. 1.24 Qtl
4 4 S&F stay assembly complete with accessories as shown in electrical plate No 1 (loop type insulator, stay clamps, excavation and concrete measured and paid seperately) dia of stay rod 20mm,complete all as specified and directed. 2 Each
5 5 S&F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade,complete all as specified and directed. 24 Each
6 6 S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball andsocket type, white, brown or green 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts,complete all as specified and directed. 6 Each
7 7 M&L Galvanised steel wire fixed on poles without kinks and bends of size 3.15 or 4mm dia,complete all as specified and directed. 1.3 Qtl
8 8 Supply & fix cable jointing kit for 11 KV (E) grade for outdoor termination cold shrink type joint complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm,complete all as specified and directed.\n Make : Denson/Raychem/M-Seal/MS Seal 2 Each
9 9 M& L for cross arms bracings ,supports, clamps & back plate fabricated from structural steel sections including nuts bolts washers , welding bending cold or hot, driling holes for bolts, in any shape or size as indicated or directed and inlusive of one primer coat , one under coat and finising coad of paint,complete all as specified and directed. 2.43 Qtl
10 10 Supply and fix Lightning arresters high tension expulsion type complete with all fittings, transmission class,suitable 11kv, discharge capacity 65 kilo amp,complete all as specified and directed. 6 Per Set
11 11 Supply and fixing danger notice board of size 25x20cm and 1.6 mm thick mild steel sheet,vitreous enamelled white,with letters, figure and conventional skull and bones in signal red colour and fixed with MS clamps ,bolts and nuts of approved size for HT, complete all as specified and directed. 10 Each
12 12 M&L for earthing in replacement complete with galvanised steel earth plate electrode 60x60x6.3mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 3.14/4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by Engr-in-Charge including necessary excavation & earth work in any typr of soil, funnel, PCC chamber (1:2:4) type CI, PCC pit cover, charcol, salt including provision of earth lead protected by 40 mm dia light grade GI pipe and 20mm dia medium grade GI pipe for watering complete all as specified and directed. 4 Each
13 13 M&L for GI tubing light grade 80 mm dia galvanised with all fittings laid in trenches as protection of cable complete all as specified and directed. 18 RM
14 14 M&L Anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed. 0.15 Per Qtl
15 15 Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying for laying GI tubing /UG cable etc complete all as specified and as directed. 35.55 Cum
16 16 Excavation in trenches not exceeding 1.5m wide, exceeding 1.5m and not exceeding 3.0m deep for foundation of poles, stays and struts etc, and getting out in hard/dense soil complete all as specified and directed. 1.62 Cum
17 17 Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, filling back in trenches after laying of cables and tested complete all as specified and directed. 10.15 Cum
18 18 Removing excavated surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. 24.82 Cum
19 19 M&L for clean dry sand laid in trenches/ducts for beding and cushioning to cable, complete all as specified and directed.\n 17.01 Cum
20 20 Supply & Laying Un -reinforced precast concrete cable cover, class HV type 1 with peak size 300mmx180mmx40mm complete all as specified and directed. 55 Each
21 21 M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in stay foundation/coping to poles, filling and mass concrete including necessary form work complete all as specified and directed. 1.2 Cum
22 22 M&L for PCC 1:4:8 type D-2 (using 40 mm graded hard granite stone aggregate) in foundations for pole or in filling complete all as specified and directed. 7.02 Cum
23 23 Supply & Laying in replacement Un -reinforced precast concrete cable cover, class LV type 1 flat size 250mmx150mmx40mm complete as in cable protection covering all as specified and directed. 1333 Each
24 24 Taking down XLPE cable any size/capacity, complete all as specified and directed 400 RM
25 25 Taking down LT panel including MCCB, MCB any size/type, complete all as specified and directed 1 Each
26 26 Supplying, laying and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor, of size 3 core & cross section area 25 Sqmm laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed. Make : Havells/Finolex/Polycab/Grandley/HPL.\n 400 RM
27 27 Supply, install, testing and commissioning of LT Panel Board 'out door type' of size 1000mm x 1000mm x 500mm (minimum dimensios) CPRI approved factory made with suitable neoprene rubber gasket to make it completely dirt & vermin proof and degree of protection not less than IP-55 and general construction conforming to IS-13947, double door front and back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation by tinned copper bus bar wrapped with colured PVC tape/sleeves of rating in conformity to the incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.00 mm thick CRCA sheet duly pre-treated & powder coated supporting frame made out of 50X50X50mm angle iron & MC 100 channel base suitable for 3 ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable grands of suitable size incl suitable PCC (1:3:6) type C-2 and cable joint with lugs in MCCBs/MCB.\n(a) MCCB 200 Amp, 4P, 50 Hz, 415 V with rupturing capacity 35 KA - 01 No (incoming)\n(b) MCB 63 Amp TPN, 50 Hz, 415 Hz, 415 V - 05 Nos\n(c) Digital type AC volt meter with built in selector switch, 3 phase, 10-100A volts range, accuracy class-0.5, size 96X96mm. Model No AE 60332 of Make AE\n(d) Digital type AC Ammeter 0 to 100 A with built in selector switch & 03 Nos CTs (Type : CBF-0.6-D1) Accuracy class - 1.0, CT Ratio-600/5, Burden-15VA), 3 Phase, Accuracy class-0.5, size 96X96mm. Model No AE 62332 of Make AE.\n(e) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, orange, Blue) - 01 set. 1 Each Job
28 28 M & L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) connected to galvanised steel wire of size 4 mm earth lead upto test point with suitable GI nuts/bolts and washers made of galvanised iron or steel earth strip protected by light grade GI wire protection pipe 40mm bore and connected for steel tubular pole all as specified and directed incl PCC work as shown in electrical plate No 3 of MES schedule Part-I 2009, pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel wire mesh 20 mm dia GI pipe medium grade for watering, charcoal & salt in alternate layers incl necessary earth pole and excavation in hard/dense soil and removal etc incl testing, all as specified and directed. 2 Each