Provision Of External Water Supply At Perimeter Post In Alpha Sect At Zangli , Spl Rep To Pipe Line From Lolab Pumphouse Collection Point To Sedimentation Tank And Spl Rep For Replacement Of Various Ber Dc Sources Of Dg Sets , Vcbs And Ocbs At Zangli G
Tender Overview
Project Description
Provision Of External Water Supply At Perimeter Post In Alpha Sect At Zangli , Spl Rep To Pipe Line From Lolab Pumphouse Collection Point To Sedimentation Tank And Spl Rep For Replacement Of Various Ber Dc Sources Of Dg Sets , Vcbs And Ocbs At Zangli Garri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-May-2021 |
BOQ
| Name of Work : PROVN OF EXTERNAL WATER SUPPLY AT PERIMETER POST IN ALPHA SECT AT ZANGLI, SPL REP TO PIPE LINE FROM LOLAB PUMPHOUSE COLLECTION POINT TO SEDIMENTATION TANK AND SPL REP FOR REPLACEMENT OF VARIOUS BER DC SOURCES OF DG SETS, VCBS AND OCBS AT ZANGLI GARRISION UNDER GE 874 EWS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 0.1 | E/M Portion | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1 | Excavation in trenches in any type of soil n exc 1.5m deep and not exc 1.5m wide for laying of under ground cable, electric pole and getting out complete all as directed. | 245 | CUM | |
| 3 | 2 | Returning filling in including spreading leveling watering and well ramming 25cm in thickness in any type of soil. | 230 | CUM | |
| 4 | 3 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point. | 15 | CUM | |
| 5 | 4 | Supply, installation and commissioning of 40 HP Centrifugal Pump Set Cast Iron body coupled with three Phase electric driven complete with necessary Electrical, plumbing and mechanical fittings and foundation as directed by Engr-in-Charge with following discription:-\nMaximum Head range of upto 120 mtrs, Brass/Gun Metal impeller, Gland packing sealed, Make-Kirloskar,or equivelant to Crompton/KSB/Kirloskar or as approved by engineer in charge. | 2 | Each | |
| 6 | 5 | S&F Rotational moulded polysthlene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, with PCC foundation to avoid water logging and sledge formation, interconnected with other tanks, all as specified in SSR part-I, Capacity of water tank 5000 Ltrs complete. \nMake-Star/Sintex/Rotex. | 4 | Each | |
| 7 | 6 | S&F GI water tubing 15mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. | 80 | RM | |
| 8 | 7 | All as per description of ser item No. 6 above but 20mm bore. | 200 | RM | |
| 9 | 8 | All as per description of ser item No. 6 above but 25mm bore. | 290 | RM | |
| 10 | 9 | All as per description of ser item No. 6 above but 40mm bore. | 245 | RM | |
| 11 | 10 | All as per description of ser item No. 6 above but 50mm bore. | 210 | RM | |
| 12 | 11 | S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of bore of 15mm complete all as specified and directed by Engr-in-Charge. | 6 | Each | |
| 13 | 12 | All as per description of ser item No. 11 above but 20mm. | 8 | Each | |
| 14 | 13 | All as per description of ser item No. 11 above but 25mm. | 2 | Each | |
| 15 | 14 | All as per description of ser item No. 11 above but 40mm. | 2 | Each | |
| 16 | 15 | All as per description of ser item No. 11 above but 50mm. | 2 | Each | |
| 17 | 16 | S&F ball valve hig pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 40mm bore complete. | 4 | Each | |
| 18 | 17 | Supply and fixing air realease valve 50mm bore with iron wheel complete all as specified and as directed. | 2 | Each | |
| 19 | 18 | Supply and fixing in replacement of starter LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x4mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25 mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed, Make of Panel Board : dvepl/aspl/tricolite/Siemen/Schnieder \n(i) MCCB TP neutral link 415 volt 50 Hz, AC 200 Amps 25 KA with adjustable thermal magnetic release for over load & short circuit protection - 01 No as Panel Incommer. \n(ii) MCCB TP neutral link 415 volt 50 Hz, AC 63 Amps 25 KA with adjustable thermal magnetic release for over load & short circuit protection - 02 Nos.\n | 1 | Each | |
| 20 | 18.1 | (iii) Star delta Starter 40 H.P. with 38Ampere Tp Heavy duty contactors, control relays, timers, auto/manual selector switch for suitable rating with ON, OFF, Trip Indicating Light, Push Buttons, Digital metering with ct/pt set, Control mcb etc. fitted in panel board for showing V,I,Hz,Pf complete all as specified and directed- 02 Nos. \n(iv) 200 Amp. smart motor protection controller of dvepl make cat no. dvmpc100 protection or equivalent of ASPL/ Tricolite/Siemen/Schnieder against auto phase polarity corrector, over voltage, under voltage, Phase loss,Phase unblanced , Phase Asymetery with On / Trip Indicating Light, auto reset with selectable on delay fitted in panel board - 01 set. | |||
| 21 | 19 | Dismantling and taking out old unserviceable CI pipe with fittings socketed/ flanged of any shape & size 150 mm dia such as bend, elbow, collar including brick masonry supporting pillers complete all as directed by Engr-in-Charge. | 80 | RM | |
| 22 | 20 | Demolition cement concrete of any description and in any position not otherwise specifically provided for complete all as directed by Engr-in-Charge. | 2.5 | CUM | |
| 23 | 21 | M & L Cement concrete work in pavement/hard standing of flexural strength 40KG/per square centimetre in field using 400 Kg of cement per cubic metre ,thickness of cconcrete 25 cm complete all as directed by Engr-in-Charge. | 1.25 | CUM | |
| 24 | 22 | Supplying, Laying, jointing, testing and commmisioning of DI Pipe with spigot (K-9) cofirming IS-8329 and socketed ends centrifugally cast Push on joint laid in trenches or over ground (as directed), complete all as specified and directed at site for 150 mm bore complete all as directed, specified and clarified by engineer in charge. | 265 | RM | |
| 25 | 23 | Material and Labour for DI fittings/specials such as Tees of any size and radious, bends, collars, tapers, tail pieces, caps and plugs from upto 150 mm bore confirming to IS:1538-1993 complete all as directed, specified and clarified by engineer in charge. | 145 | kgs | |
| 26 | 24 | Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI pipe of 150 mm bore dia complete all as directed. | 2 | Each | |
| 27 | 25 | Labour for cutting of CI/DI pipe in position for reducing to required length for insertion of new tees, branches, for repair work of 150 mm bore dia complete all as directed. | 2 | JOB | |
| 28 | 26 | Supply and fixing cast iron air release valve, confirming IS-14845 with two air lets with nuts, bolts, washers and gaskets including taking out old unserviceable air valve of size 80 mm dia complete all as specified and directed by Enginner-in-charge. | 1 | Each | |
| 29 | 27 | Supply and fixing sluice valve cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it class PN 1.6 confirming to IS 14846-2000 including necessary fixing arrengemet such as rubber insulation, packing rings, jointing materials nuts, bolts washer, gasket and packings material etc all as specified and d including taking out old CI Unsv Sluice valve irected for 150 mm dia complete all as specified and directed. | 1 | Each | |
| 30 | 28 | Supply and fixing & testing in replacement of CI Non return valve of size 150mm bore without bypass arrangement swing type confirming to IS 5312-1 flanged end, pressure rating PN 1.6 complete including taking out old CI Unsv Non Return valve all as specified and directed. | 1 | Each | |
| 31 | 29 | PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in for foundation of DI Pipe, filling & mass concrete complete all as specified and directed. | 2.3 | CUM | |
| 32 | 30 | Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean built in Cement mortar 1:4 for supporting of DI pipe line 150 mm dia complete all as directed. | 11 | CUM | |
| 33 | 31 | Plastering on stone masonry surfaces or suface other than fair face of brickwork or on of lathing,for each 10 mm thickness over and finished smooth (without using extra lime or cement ) for Cement mortar 1:4 complete all as directed. | 4 | EACH | |
| 34 | 32 | Supply and installation, testing and commissioning of 12 Volts 150 AH tubular battery for use in Generator Sets/ VCBs/ OCBs, etc with minimum warranty of 48 months (replacement/ free repair warranty) from date of installation, of make Exide/ Luminous/ Amco. | 12 | Each | |
| 35 | 33 | Supply and installation, testing and commissioning of battery bank of 110 Volts or 24 Volts containing 55 Nos (for 110V) or 12 Nos (for 24V) batteries (using copper conductors for connecting) using batteries (batteries to be measured and paid separately in Srl Item No. 3 here in after). | 2 | Each Set | |
| 36 | 34 | Valve Regulated Lead Acid Type, 2 Volt Batteries of 125 AH each for use in VCBs/ OCBs with minimum comprehensive warranty of 48 months (replacement/ free repair warranty) from date of installation of make Exide/ Luminous/ AMCO or equivalent as approved by engineer in charge.\nNote : Batteries should be compatible and chargeable by the battery charger being installed by the item No. 4 and 5 here in after. | 67 | Each | |
| 37 | 35 | Supply and installation, testing and commissioning of smart battery charger for charging battery pack, that can charge above battery packs (by charging individual batteries, simultaneously), provide DC output to VCBs, from 170 V to 220V AC supply when main supply is present and through battery when main supply is absent, with charger capable of providing output of 110 V DC or 24V DC or 12V DC or 230V AC or all four, with output supply stabilised with no variation more than 0.5V, with charger of make power control systems or equivalent as approved by engineer in charge. | 1 | Each | |
| 38 | 36 | Supply and installation, testing and commissioning of smart battery charger for charging 24V (and 12V) battery packs, that can charge above battery packs (by charging individual batteries, simultaneously), provide DC output to VCBs, from 170 V to 220V AC supply when main supply is present and through battery when main supply is absent, with charger capable of providing output of 24V DC or 12V DC or 230V AC or all four, with output supply stabilised with no variation more than 0.5V, with charger of make power control systems or equivalent as approved by engineer in charge. | 1 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender