}

District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode, Kumbala-Kerala

Steel Industrials Kerala Limited has published District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode. Submission Date for this Tender is 19-04-2021. Earth Moving Machinery Tenders in Kumbala Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

27642080
District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode
Open Tender
Indian
Kerala
Kumbala
19-04-2021

Tender Details

District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode District Forensic Science Laboratory At Old Circle Inspector Office Kumbala , Kasaragode - 14.43 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 2 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface: Water Thinnable Cement Primer 3 13.51.2 Painting With Silicon & Acrylic Emulsion Based Water Thinnable Sealer Of Approved Brand And Manufacture On Wet Or Patchy Portion Of Plastered Surfaces: Two Coats N 4 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Nsize Of Tile 600 X 600 Mm. N 5 15.23.1 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm 6 11.36 Providing And Fixing I St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer -In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. N 7 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. 8 9.105.2 Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed / Roll Form G.I. Sheet With Zinc Coating Of 120 Gms / ( Both Side Inclusive ) , Consisting Of Floor And Ceiling Channel 50 Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of 610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width ( 0.9 Mm Thick Having Two Flanges Of 9.5 Mm Each ) To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corners ( 25 Mm X 25 Mm X0.5 Mm ) , Joint Finisher And Two Coats Of Primer Suitable For Board As Per Manufactures Specification And Direction Of Engineer In Charge All Complete. 75 Mm Overall Thickness Partition With 12.5 Mm Thick Double Skin Tapered Edged Plain Gypsum Board Conforming To Is : 2095 : Part I 9 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: Nw.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 10 17.7.7 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: Nwhite Vitreous China Flat Back Wash Basin Size 450X300 Mm With Single 15 Mm C.P. Brass Pillar Tap 11 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge. Npre- Laminated Particle Board With Decorative Lamination On Both Sides 12 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : Nfor Fixed Portion Npowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) N 13 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : Nwith Float Glass Panes Of 4.0 Mm Thickness N 14 2.31 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared 15 2.8.1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. Nall Kinds Of Soil 16 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: N1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) 17 2.25 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 18 5.1.2  Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level: 1:1:5:3 ( 1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size 19 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 150 Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 20 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 21 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platform 22 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 23 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts 24 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level:Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 25 5.22A.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Nthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 26 50.6.7.1 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20x15cm Or Nearest Size In Cement Mortar 1:6 For Foundation And Basement Including All Cost Of Materials, Labour Charges Etc. 27 50.6.7.2 Laterate Masonry With Neatly Dressed Laterate Stone Of Size 40X20x15cm Or Nearest Size In Cement Mortar 1:6 For Super Structure Above Plinth Level Up To Floor Two Level Including All Cost Of Materials, Labour Charges Etc. 28 11.36 Providing And Fixing I St Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer -In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 29 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) , Of 1St Quality Conforming To Is : 15622, Of Approved Make, In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. 30 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. 31 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) 32 13.16.1 6 Mm Cement Plaster Of Mix: N1:3 ( 1 Cement : 3 Fine Sand ) 33 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications: Ntwo Or More Coats Applied On Walls @ 1.25 Ltr / 10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr / 10 Sqm 34 17.2.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 35 9.105.2 Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board, Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed / Roll Form G.I. Sheet With Zinc Coating Of 120 Gms / ( Both Side Inclusive ) , Consisting Of Floor And Ceiling Channel 50 Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Ceiling At The Spacing Of 610 Mm Centre To Centre With Dash Fastener Of 12.5 Mm Dia Meter 50 Mm Length Or Suitable Anchor Fastener Or Metal Screws With Nylon Plugs And The Studs 48 Mm Wide Having One Flange Of 34 Mm And Other Flange 36 Mm And 0.50 Mm Thick Fixed Vertically Within Flanges Of Floor And Ceiling Channel And Placed At A Spacing Of 610 Mm Centre To Centre By 6 Mm Dia Bolts And Nuts, Including Fixing Of Studs Along Both Ends Of Partition Fixed Flush To Wall With Suitable Anchor Fastener Or Metal Screws With Nylon Plugs At Spacing Of 450 Mm Centre To Centre, And Fixing Of Boards To Both Side Of Frame Work By 25 Mm Long Dry Wall Screws On Studs, Floor And Ceiling Channels At The Spacing Of 300 Mm Centre To Centre. The Boards Are To Be Fixed To The Frame Work With Joints Staggered To Avoid Through Cracks, M.S. Fixing Channel Of 99 Mm Width ( 0.9 Mm Thick Having Two Flanges Of 9.5 Mm Each ) To Be Provided At The Horizontal Joints Of Two Boards, Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corners ( 25 Mm X 25 Mm X0.5 Mm ) , Joint Finisher And Two Coats Of Primer Suitable For Board As Per Manufactures Specification And Direction Of Engineer In Charge All Complete.75 Mm Overall Thickness Partition With 12.5 Mm Thick Double Skin Tapered Edged Plain Gypsum Board Conforming To Is : 2095 : Part I 36 17.7.7  Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Flat Back Wash Basin Size 450X300 Mm With Single 15 Mm C.P. Brass Pillar Tap 37 17.7.6 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Angle Back Wash Basin Size 400X400 Mm With Single 15 Mm C.P. Brass Pillar Tap 38 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 39 21.1.2.2 Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Npowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 40 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness 41 50.17.1.4 Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 42 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 43 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood 44 9.48.2 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc 45 11.20.3 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) . Dark Shade Pigment Using Ordinary Cement 46 18.48 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 47 21.4.1 Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is: 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors, Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer -In- Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness 48 21.18 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately ) 49 General Plumbing Including Septic Tank ( Pvc 2000L ) 50 Providing And Fixing 6 Pvc Door For Toilet 51 Providing And Fixing Lab Door Including Neccessary Fitting 52 1.1.2 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 53 1.20.1 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required 20 Mm 54 1.23.1 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. 5 / 6 Amps Switch 55 1.23.3 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. 15 / 16 Amp Switch 56 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet 57 1.23.5 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 58 1.27.1 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) 59 1.27.3 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As 756 Equired. 4 Module ( 125Mmx75mm ) 60 1.27.5 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( 125Mmx125mm ) 61 1.27.6 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 12 Module ( 200Mmx150mm ) 62 5.1 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But Without Charcoal / Coke And Salt ) As Required. 63 2.3.2 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator. 8 Way, Double Door 64 2.10.2 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole And Netural 65 2.10.3 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole 66 2.12.2 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 67 2.14.3 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 68 Od357289 / 2020_2021 Supply And Installation Of Island Bench 3200L X 1500 B X 900 H ) Mm -Table Consisting Of:-Base Unit 2 Doors 1 Drawers -750Mm-4Nos, Base Unit 1 Door 1 Drawer -450Mm-1Nos, Leg Space Assembly With Back Panel-4Nos, Blank Panelling-2Set, Square Metal Electrical Raceway -3M, Electrical Points On Raceway -5 / 15 Switch Sockets ( Without Wiring ) -12Nos, 2 Tier Reagent Rack-900Mm- 3Nos, Service Dropper 200X120x2100mm-1Nos, Jet Black Granite Work Top 20Mm Thick -27Sqt 69 Od357290 / 2020_2021 Supply And Installation Of Wall Bench 3900L X 750 B X 900 H ) Mm -Table Consisting Of:-Base Unit 2 Doors 1 Drawers -750Mm-3Nos, Base Unit For Sink 2 Door- 750Mm- 1Nos, Leg Space Assembly With Back Panel-1Nos, Blank Panelling-1Set, Triangular Metal Electrical Raceway -3.15M, Electrical Points On Raceway -5 / 15 Switch Sockets ( Without Wiring ) -6Nos, Pp Sink Of Size 560X350mm-1Nos, One Way Water Trap-1Nos, Jet Black Granite Work Top 20Mm Thick -33Sqt 70 Od357291 / 2020_2021 Upply And Installation Of Wall Bench 3900L X 750 B X 900 Hmm -Table Consisting Of:-Base Unit 2 Doors 1 Drawers -750Mm-4Nos, Leg Space Assembly With Back Panel-1Nos, Blank Panelling-1Set, Triangular Metal Electrical Raceway -3.9M, Electrical Points On Raceway -5 / 15 Switch Sockets ( Without Wiring ) -8Nos, Jet Black Granite Work Top 20Mm Thick -33Sqt 71 Od357292 / 2020_2021 Supply And Installation Of Wall Bench 5100L X 750 B X 900 H ) Mm Table Consisting Of:-Base Unit 2 Doors 1 Drawers -750Mm-4Nos, Leg Space Assembly With Back Panel-3Nos, Blank Panelling-1Set, Corner Supporting Frame-1Nos, Triangular Metal Electrical Raceway -5.85M, Electrical Points On Raceway -5 / 15 Switch Sockets ( Without Wiring ) -8Nos, , Jet Black Granite Work Top 20Mm Thick -43Sqt 72 Od357293 / 2020_2021 Supply And Installation Of Wall Bench 3805L X 750 B X 900 H ) Mm -Table Consisting Of:-Base Unit 2 Doors 1 Drawers -750Mm-1Nos, Base Unit 1 Door 1 Drawer -450Mm-2Nos, Base Unit For Sink 2 Door- 750Mm- 1Nos, Leg Space Assembly With Back Panel-1Nos, Blank Panelling-1Set, Corner Supporting Frame-1Nos, Triangular Metal Electrical Raceway -3M, Electrical Points On Raceway -5 / 15 Switch Sockets ( Without Wiring ) -6Nos, Pp Sink Of Size 560X350mm-1Nos, One Way Water Trap-1Nos, Jet Black Granite Work Top 20Mm Thick -32Sqt 73 Od357294 / 2020_2021 Supplying Shelves For Cabinets As Per Direction Of Engineeer In Charge 74 Od357295 / 2020_2021 Supplying Locks For Cabinets Drawers For Cabinets Drawers As Per The Direction Of Engineer In Charge 75 Supply Of Led Tube Light 76 Supply Of Ceiling Fan 77 Supply And Fixing 8W Led Panel Light 78 Supply And Fixing Of Front Light 79 Supply And Installation Of 1.5 Tonne Ac 80 Officers Table 81 Supply Furniture For Ad Room 82 Reception Table With Chair 83 Providing And Fixing Of Window Blinds 84 Officers Revolving Chair 85 Providing Revolving Executive Chair

Key Value

Document Fees
INR 2950 /-
EMD
INR 50000.0 /-
Tender Value
INR 46.07 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail