FileName | File Description | File Size |
Tendernotice_1.pdf | Tender Document-NIT | 2789.46 |
BOQ_658527.xls | Tender Document-BOQ | 347.00 |
F3024B6F-68DC-4D1B-AC28-741C604BD800.html | Tender Notice-Tender Notice | 0 |
etendernotice30.pdf | Tender Document-E-Tender Notice | 855.73 |
Name of Work:- M/o completed schemes under Nazul A/C -II, South Zone SH:- MOEI & Fans at DDA Community Halls Kishangarh Village , Sec.-A, Sarswati Block , E-2 housing at Vasant Kunj , Mohammadpur Village , Vasant Gaon etc. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Annual running operation & preventive maintenance of all clear water boosters, Fire Fighting, D.G. pump, dewatering,terrace pump sets,Fire alarm system,hydrants,Ventilation system ,Ten Passenger Lift in Community Hall Kishangarh and all internal/External electrical installations, watch and ward at DDA's Community hall Kishan garh Village , Sec.-A, Sarswati Block , E-2 housing at Vasant Kunj & Mohammadpur , Vasant Gaon as per schedule,terms and conditions,specifications attached herewith, complete as required | 12 | Month | |
2 | 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required\ni.)Group B | 25 | Point | |
3 | 3 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same\nin case of recessed conduit as required\ni)20 mm | 100 | metre | |
4 | 3.1 | 25 mm | 50 | metre | |
5 | 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.\ni.) GROUP C | 50 | Point | |
6 | 4.1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.\ni.)3x4 Sq mm | 180 | Metre | |
7 | 5 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)\ni.)6 way , Double door | 2 | Each | |
8 | 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required\ni)Single pole and neutral | 30 | Each | |
9 | 6.1 | Single pole | 60 | Each | |
10 | 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required\ni..)S.P. 5/6 amps, one way modular switch, ISI marked | 40 | Each | |
11 | 7.01 | S.P. 15/16 amps, one way modular switch, ISI marked | 30 | Each | |
12 | 7.02 | 6 pin 15/16 amps modular socket outlet, ISI marked | 30 | Each | |
13 | 7.03 | S.P. 5/6 amp switch P/T , ISI marked | 80 | Each | |
14 | 7.04 | S.P. 15/16 amps P/T switch, ISI marked | 30 | Each | |
15 | 7.05 | 3 pin 5/6 amps P/T socket outlet, ISI marked | 30 | Each | |
16 | 7.06 | 6 pin 15/16 amps P/T socket outlet, ISI marked | 30 | Each | |
17 | 7.07 | Modular blanking plate | 20 | Each | |
18 | 7.08 | Stepped type Modular Fan regulator (2 module) | 40 | Each | |
19 | 7.09 | Modular base & cover plate for 8 module | 2 | Each | |
20 | 7.1 | Modular base & cover plate for 12 module | 2 | Each | |
21 | 8 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. | 10 | Each | |
22 | 9 | Supplying and fixing PVC batten/ angle holder including connections etc. as required | 10 | Each | |
23 | 10 | Supply and Fixing LED Tube/Lamp in the existing fitting including connections,testing and commissioning etc as required.\ni.)LED Tube 20 Watt 4 Feet | 60 | Each | |
24 | 10.01 | LED Tube-18Watt 4 Pin in place of PLL,36 watt,4 Pin | 80 | Each | |
25 | 10.02 | Holder for PLL Lamp,4 Pin | 40 | Each | |
26 | 10.03 | LED Lamp-9 Watt(Retrofit) | 25 | Each | |
27 | 11 | Rewinding of ceiling fan with enamelled Insulated Copper wire of superior quality including dismantling,varnishing,Baking, providing/Replacing Bearings,reassembling,testing etc as required | 30 | Each | |
28 | 12 | Supplying and Replacing Metal body Heavy Duty Exhaust fan 300mm sweep (6 Poles)having Copper wound Motor, with louver shutter on existing wall,including making hole to suit the size,connections with 3x1.5 Sq mm PVC Insulated & PVC sheathed (Round)Wire,Testing,commissioning etc as required. | 8 | Each | |
29 | 13 | Supply and replacing of Ceiling Fan of 1400 mm sweep 230 V,single phase,ISI Marked(Copper Wound) including dismantling,wiring the down rod with 2x1.5sq.mm copper wire connection testing as required. | 20 | Each | |
30 | 14 | Supply and replacing of Wall Fan of 400 mm sweep 230 V,single phase,ISI Marked(Copper Wound) including dismantling,connection, testing as required. | 4 | Each | |
31 | 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required\ni.)Triple pole and neutral | 4 | Each | |
32 | 16 | Supplying of the following size,1.1KV grade , PVC Insulated,PVC sheathed/XLPE Aluminium conductor , Armoured power cable.\ni.) 2core x 16 sq. mm | 200 | Metre | |
33 | 17 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.\ni)Upto 35 sq. mm (clamped with 1mm thick saddle) | 200 | Metre | |
34 | 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 200 | Metre | |
35 | 19 | Servicing of Fire Pump engine,Engine no.1720016 ,72 H.P along with Control panel including providing & replacing following spares,testing,commisioning etc as required.\ni.)KOEL CARE Premium Genuine Oil 20 Liters CAN B5:B18-1 No.\nii.)Lub Oil Filter(06.436.01.0.00)-2 No\niii)Fuel Filter Element(03.922.42.0.00)-2 No.\niv)Pri Air Filter Element(F6.729.07.0.00)-1 No.\nv)Battery lead-2 No\nvi)KOEL CARE GENUINE COOLANT PREMIX 5 LITRE CAN(82.020.35.1.26)-1 No | 1 | Set | |
36 | 20 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories\ni)Pendent Sprinkler/Upright Sprinkler | 15 | Each | |
37 | 21 | Refilling of fire Extinguisher CO2 type 4.5KG(Hydraulic pressure test ,Refilling , replacement of discharge pipe, safety valve and gauge where ever applicable, painting the cylinder & providing stickers, labeling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities. | 16 | Each | |
38 | 22 | Refilling of fire Extinguisher Water( Stored type) CO2 9KG (replacement of discharge pipe , safety valve etc where ever applicable including painting the cylinder & providing stickers, labeling with date of refilling and expiry date of refilling as per the ISI standards and as per the norms of Fire Authorities. | 16 | Each | |
39 | 23 | Providing & fixing Powder fire extinguisher (Stored Pressure Type) capacity 6 kg duly ISI mark conferming to IS-15683:2006, U:L listed map 90% powder, ABC powder complete with squeeze grip release valve, discharge pipe locking arrangement, pressure guage, operation mannual and bracket. etc. complete as required. | 12 | Each | |
40 | 24 | Providing and fixing 9 litre capacity Mechanical foam(AFFF) potable fire extinguisher type ISI marked confirming to IS:15683 with gas cartridge,delivery hose,squeeze grip release valve,locking arrangement,operation manual and bracket complete in all respect at suitable loaction as per direction of engineer-in-charge as required. | 12 | Each | |
41 | 25 | Supply and fixing of out door Flood light for compound light fitting with following rating including connection testing complete as required.\ni.)30 Watt LED ,light luminaire of IP66 | 12 | Each | |
42 | 25.1 | ii)LED Flood Light,90 Watt(SMD type),IP 66 rating | 6 | Each | |
43 | 26 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.(Foundation size-1.15m(L)x.60m(W)x1m(D)) | 0.69 | cum | |
44 | 27 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,\njointing etc. in the existing trench, complete as required.\ni.)63 mm dia (OD-63 mm & ID-51 mm nominal) | 18 | metre | |
45 | 28 | SITC 100 Amp. 440/500 Volts four pole ON load changeover switch with enclosure & handle etc. on existing wall i/c connections etc. as required | 1 | Set | |
46 | 29 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. | 4.2 | cum | |
47 | 30 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.\ni.)63 A | 2 | Each | |
48 | 31 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.\ni)100 A, 16 KA,TPMCCB | 2 | Each | |
49 | 32 | Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes\nin cubicle panel, making connections, etc. as required.\ni.)4 pole MCCB,100A,30KA | 1 | Each |
Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail