Construction Of Sps Toilet Blocks At Sarvodaya Kanya Vidyalaya No . 2 , Palam Village , New Delhi . During 2020-21 . Electrical Work

Tender Notice

27613712
Construction Of Sps Toilet Blocks At Sarvodaya Kanya Vidyalaya No . 2 , Palam Village , New Delhi . During 2020-21 . Electrical Work
Indian
Delhi
08-04-2021
15-04-2021
15-04-2021

Tender Details

Construction Of Sps Toilet Blocks At Sarvodaya Kanya Vidyalaya No . 2 , Palam Village , New Delhi . During 2020-21 . Electrical Work

Key Value

Document Fees
Refer document
EMD
INR 2542.00 /-
Tender Value
INR 1.27 Lakhs /-

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document-Notice Inviting Tender 350.39
1BAEDD83-371F-4A3C-B2C1-3F624D0F4112.html Tender Notice-Tender Notice 0
BOQ_257929.xls Tender Document-BOQ 292.50

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work : Construction of SPS toilet blocks at Sarvodaya Kanya Vidyalaya No. 2, Palam village, New Delhi. During 2020-21. (SH:- Electrical work).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2 1.01 Group C 31 Pts
3 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
4 2.01 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 23 Mtrs
5 2.02 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 85 Mtrs
6 3 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
7 3.01 63 A 1 Nos
8 4 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. i/c dismantling & credit of old dismantled material as and where basis etc complete as required.
9 4.01 15/16 A switch 12 Nos
10 4.02 6 pin 15/16 A socket outlet 12 Nos
11 5 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12 5.01 Single pole 1 Nos
13 6 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i/c dismantling & credit of old dismantled material as and where basis etc complete as required.
14 6.01 63 A 1 Nos
15 7 Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium cable ISI marked of following size etc as required.
16 7.01 3 x 10 sqmm (On Surface) 110 Mtrs
17 7.02 3 x 10 sqmm (in ground) including excavation and refilling the trench etc as reqd but excluding sand cushioning and protective covering. 4 Mtrs
18 8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
19 8.01 16 way, Double door 1 Nos
20 9 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
21 9.01 6 Module (200 mmX75 mm) 6 Nos
22 10 Supplying and fixing of 300 mm sweep 900 RPM exhaust fan complete with louvers and shutters in the existing opening i/c making the hole to suit the size of above fan, making good the damages, connection, testing, commissioning etc. as reqd. 5 Nos
23 11 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
24 11.01 3 X 10 sq. mm (22mm) 2 Nos
25 12 Supplying installation testing and commissioning of IP65 Surface mounted Led bulkhead type fitting 10-12watt in 5000-6000 K CCT including mounting on surface with help of MS clamps etc including connections ,earthing etc as reqd. 3 Nos
26 13 Supplying, installation, testing & commissioning of flood light fitting LED made of pressure die cast aluminum with high power LED of 50 watt (intergral type) with having following features: Luminous efficcacy >120 lm/watt, CCT = 3000K, CRI>70, Surge protection device = 5KV, Secondary optics with lens, IP 66 housing, electronic driver, on the existing cove / wall in underpass including suitable sized wiremesh cage etc as per as per specification given in terms and conditions etc. complete as required. 2 Nos
27 14 SITC of 15-18 watt surface mounted Square Downlighter LED fittings size 1 ft x 1 ft. having minimum system efficacy of 100 lumens/watt and colour temperture of 5500-6500 kelvin and CRI of >80 and having power factor of >0.95, THD <10% i/c fixing on the surface with the help of suitble size of screw and fastners i/c connections with 3x1.5 Sq mm FRLS PVC Insulated copper conductor cable etc. complete as reqd. 23 Nos