| 1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.1 | Group A | | 1 | Point |
|---|
| 3 | 1.2 | Group B | | 1 | Point |
|---|
| 4 | 1.3 | Group C | | 1 | Point |
|---|
| 5 | 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | | | |
|---|
| 6 | 2.1 | Group A | | 1 | Point |
|---|
| 7 | 2.2 | Group B | | 1 | Point |
|---|
| 8 | 2.3 | Group C | | 1 | Point |
|---|
| 9 | 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | | | |
|---|
| 10 | 3.1 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | | 1 | Mtr |
|---|
| 11 | 3.2 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | | 1 | Mtr |
|---|
| 12 | 3.3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire | | 1 | Mtr |
|---|
| 13 | 3.4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | | 1 | Mtr |
|---|
| 14 | 3.5 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire | | 1 | Mtr |
|---|
| 15 | 3.6 | 2 X 16 sq. mm + 1 X 16 sq. mm earth wire | | 1 | Mtr |
|---|
| 16 | 4 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. | | | |
|---|
| 17 | 4.1 | Group A | | 1 | Point |
|---|
| 18 | 4.2 | Group B | | 1 | Point |
|---|
| 19 | 4.3 | Group C | | 1 | Point |
|---|
| 20 | 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | | | |
|---|
| 21 | 6 | 2 X 1.5 sq. mm | | 1 | Mtr |
|---|
| 22 | 7 | 3 X 1.5 sq. mm | | 1 | Mtr |
|---|
| 23 | 8 | 4 X 1.5 sq. mm | | 1 | Mtr |
|---|
| 24 | 9 | 2 X 2.5 sq. mm | | 1 | Mtr |
|---|
| 25 | 10 | 3 X 2.5 sq. mm | | 1 | Mtr |
|---|
| 26 | 11 | 4 X 2.5 sq. mm | | 1 | Mtr |
|---|
| 27 | 12 | 2 X 4 sq. mm | | 1 | Mtr |
|---|
| 28 | 13 | 3 X 4 sq. mm | | 1 | Mtr |
|---|
| 29 | 14 | 4 X 4 sq. mm | | 1 | Mtr |
|---|
| 30 | 15 | 2 X 6 sq. mm | | 1 | Mtr |
|---|
| 31 | 16 | 3 X 6 sq. mm | | 1 | Mtr |
|---|
| 32 | 17 | 4 X 6 sq. mm | | 1 | Mtr |
|---|
| 33 | 18 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. | | | |
|---|
| 34 | 19 | 1 Pair | | 1 | Mtr |
|---|
| 35 | 20 | 2 Pair | | 1 | Mtr |
|---|
| 36 | 21 | 4 Pair | | 1 | Mtr |
|---|
| 37 | 22 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. | | 1 | mtr |
|---|
| 38 | 23 | Supplying and fixing of following sizes of medium class PVC conduit/ casin caping along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | | | |
|---|
| 39 | 24 | 20mm | | 1 | Mtr |
|---|
| 40 | 25 | 25mm | | 1 | Mtr |
|---|
| 41 | 26 | 40mm | | 1 | Mtr |
|---|
| 42 | 27 | 50mm | | 1 | Mtr |
|---|
| 43 | 28 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. | | | |
|---|
| 44 | 29 | 5/6 amps switch | | 1 | Nos |
|---|
| 45 | 30 | 3 pin 5/6 A socket outlet | | 1 | Nos |
|---|
| 46 | 31 | 15/16 A switch | | 1 | Nos |
|---|
| 47 | 32 | 6 pin 15/16 A socket outlet | | 1 | Nos |
|---|
| 48 | 33 | Telephone socket outlet | | 1 | Nos |
|---|
| 49 | 34 | TV antenna socket outlet | | 1 | Nos |
|---|
| 50 | 35 | Bell push | | 1 | Nos |
|---|
| 51 | 36 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as require | | | |
|---|
| 52 | 37 | 5/6 amps switch | | 1 | Nos |
|---|
| 53 | 38 | 3 pin 5/6 A socket outlet | | 1 | Nos |
|---|
| 54 | 39 | 15/16 A switch | | 1 | Nos |
|---|
| 55 | 40 | 6 pin 15/16 A socket outlet | | 1 | Nos |
|---|
| 56 | 41 | Telephone socket outlet | | 1 | Nos |
|---|
| 57 | 42 | TV antenna socket outlet | | 1 | Nos |
|---|
| 58 | 43 | Bell push | | 1 | Nos |
|---|
| 59 | 44 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | | 1 | Nos |
|---|
| 60 | 45 | Supplying and fixing following size/ modules, GI /PVC box alongwith modular base & cover plate for modular switches in recess/ surface etc. as required. | | | |
|---|
| 61 | 46 | 1 or 2 Module | | 1 | Nos |
|---|
| 62 | 47 | 3 Module | | 1 | Nos |
|---|
| 63 | 48 | 4 Module | | 1 | Nos |
|---|
| 64 | 49 | 6 Module | | 1 | Nos |
|---|
| 65 | 50 | 8 Module | | 1 | Nos |
|---|
| 66 | 51 | 12 Module | | 1 | Nos |
|---|
| 67 | 52 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required | | | |
|---|
| 68 | 53 | 1 or 2 Module | | 1 | Nos |
|---|
| 69 | 54 | 3 Module | | 1 | Nos |
|---|
| 70 | 55 | 4 Module | | 1 | Nos |
|---|
| 71 | 56 | 6 Module | | 1 | Nos |
|---|
| 72 | 57 | 8 Module | | 1 | Nos |
|---|
| 73 | 58 | 12 Module | | 1 | Nos |
|---|
| 74 | 59 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. | | 1 | Nos |
|---|
| 75 | 60 | Supply and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. | | 1 | Mtr |
|---|
| 76 | 61 | Installation, testing and commissioning of pre-wired, LED fitting / compact LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. | | 1 | Nos |
|---|
| 77 | 62 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. | | 1 | Nos |
|---|
| 78 | 63 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. | | | |
|---|
| 79 | 64 | Upto 510 mm sweep | | 1 | Nos |
|---|
| 80 | 65 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes | | 1 | Nos |
|---|
| 81 | 66 | Supplying and fixing PVC batten/ angle holder/Celling rose including connections etc. as required. | | 1 | Nos |
|---|
| 82 | 67 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required | | | |
|---|
| 83 | 68 | 100 A,30KA,FPMCCB | | 1 | Nos |
|---|
| 84 | 69 | 200 A,36KA,FPMCCB | | 1 | Nos |
|---|
| 85 | 70 | 250 A,36KA,FPMCCB | | 1 | Nos |
|---|
| 86 | 71 | 400 A,50KA,FPMCCB | | 1 | Nos |
|---|
| 87 | 72 | 200 A ,FP on load Changeover with enclosure | | 1 | Nos |
|---|
| 88 | 73 | 630 A ,FP on load Changeover with enclosure | | 1 | Nos |
|---|
| 89 | 74 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 90 | 75 | 6 way , Double door | | 1 | Nos |
|---|
| 91 | 76 | 8 way , Double door | | 1 | Nos |
|---|
| 92 | 77 | 12 way , Double door | | 1 | Nos |
|---|
| 93 | 78 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 94 | 79 | 4 way , Double door | | 1 | Nos |
|---|
| 95 | 80 | 6 way , Double door | | 1 | Nos |
|---|
| 96 | 81 | 8 way , Double door | | 1 | Nos |
|---|
| 97 | 82 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required | | | |
|---|
| 98 | 83 | Single pole | | 1 | Nos |
|---|
| 99 | 84 | Single pole and neutral | | 1 | Nos |
|---|
| 100 | 85 | Double pole | | 1 | Nos |
|---|
| 101 | 86 | Triple pole | | 1 | Nos |
|---|
| 102 | 87 | Triple pole and neutral | | 1 | Nos |
|---|
| 103 | 88 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | | 1 | Nos |
|---|
| 104 | 89 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | | | |
|---|
| 105 | 90 | 40 Amp | | 1 | Nos |
|---|
| 106 | 91 | 63 Amp | | 1 | Nos |
|---|
| 107 | 92 | 100 Amp | | 1 | Nos |
|---|
| 108 | 93 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. | | 1 | Nos |
|---|
| 109 | 94 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. | | 1 | Nos |
|---|
| 110 | 95 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | | | |
|---|
| 111 | 96 | Upto 35 sq. mm | | 1 | Mtr |
|---|
| 112 | 97 | Above 35 sq. mm and upto 95 sq. mm | | 1 | Mtr |
|---|
| 113 | 98 | Above 95 sq. mm and upto 185 sq. mm | | 1 | Mtr |
|---|
| 114 | 99 | Above 185 sq. mm and upto 400 sq. mm | | 1 | Mtr |
|---|
| 115 | 100 | Supply of insulation Tape. | | 1 | Nos |
|---|
| 116 | 101 | Supply of 1200 mm sweep 230 V 50 HZ ceiling fan with double ball bearing with low power consumption | | 1 | Nos |
|---|
| 117 | 102 | Supply of following size of heavy duty exhaust fan as per approved make. | | | |
|---|
| 118 | 103 | 300mm | | 1 | Nos |
|---|
| 119 | 104 | 250 mm with louver | | 1 | Nos |
|---|
| 120 | 105 | Supply of 300 mm sweep 230 V 50 HZ wall fan with low power consumption. | | 1 | Nos |
|---|
| 121 | 106 | Supply, installation, testing and commissioning of 35 Ltr Storage water heater of 5 star Rating including fixing of set of stainless steel pipes, fixing of bolts in the walls etc | | 1 | Nos |
|---|
| 122 | 107 | Supply, installation, testing and commissioning of heating element for geyser/ water heater of different size and capacity. Including dismentelling of old existing damaged element. | | 1 | Nos |
|---|
| 123 | 108 | Supply, installation, testing and commissioning of over heating control element manual on for geyser/ water heater of different size and capacity. Including dismentelling of old existing damaged element. | | 1 | Nos |
|---|
| 124 | 109 | Supply, installation, testing and commissioning of over heating controlling element auto for geyser/ water heater of different size and capacity. Including dismentelling of old existing damaged element. | | 1 | Nos |
|---|
| 125 | 110 | Supply, installation, testing and commissioning of 3 pin 15 Amp Top. Including connections as required comlplete Job | | 1 | Nos |
|---|
| 126 | 111 | Supply, installation, testing and commissioning of 3 pin 5 Amp Top. Including connections as required comlplete Job | | 1 | Nos |
|---|
| 127 | 112 | Supply of Concealed LED light fixture 9 watt . | | 1 | Nos |
|---|
| 128 | 113 | Supply of Concealed LED light fixture 15 watt . | | 1 | Nos |
|---|
| 129 | 114 | Supply of 1x1 Concealed LED penel 15 watt . | | 1 | Nos |
|---|
| 130 | 115 | Supply of 2x2 Concealed LED penel 20 watt . | | 1 | Nos |
|---|
| 131 | 116 | Supply of LED tube fitting box type 18 watt. | | 1 | Nos |
|---|
| 132 | 117 | Supply of LED batten 18 watt. | | 1 | Nos |
|---|
| 133 | 118 | Supply of LED lamp 9 watt. | | 1 | Nos |
|---|
| 134 | 119 | Supply of LED lamp 15 watt. | | 1 | Nos |
|---|
| 135 | 120 | Supply of LED lamp 20 watt. | | 1 | Nos |
|---|
| 136 | 121 | Supply, installation, testing and commissioning of 45 watt LED Flood light fitting complete with all accessories,MS clamps ,Fastener etc. Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 137 | 122 | Supply, installation, testing and commissioning of 70 watt LED Street light fitting complete with all accessories, like GI bracket ,MS clamps ,Fastener etc. Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 138 | 123 | Supply, installation, testing and commissioning of Air cooler PVC body complete with all accessories, Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 139 | 124 | Supply, installation, testing and commissioning of 2 KVa uninterrupted power supply, 240 V, 1 Ø input and 240 V, 1 Ø output, along with necessary protections such as, overload, short circuit protection etc. Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 140 | 125 | Supply, installation, testing and commissioning of 200Ah inverter battery 36 month warranty. Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 141 | 126 | Providing of maintenance free earthing with 3.0m 50mm dia G.I Electrode along with backfill materials as required to achieve values less than 2 ohms, including connection using copper bus complete job as required. Makes JMV/Fastrack or equivalent makes. | | 1 | Nos |
|---|
| 142 | 127 | Supply of Three Phase Water pumping motor 2 HP Monoblock . | | 1 | Nos |
|---|
| 143 | 128 | Supply of Three Phase Water pumping motor 5 HP Monoblock . | | 1 | Nos |
|---|
| 144 | 129 | Supply of three phase D.O.L motor starter upto 5HP. | | 1 | Nos |
|---|
| 145 | 130 | Supply of three phase electronic energy meter 40-80. | | 1 | Nos |
|---|
| 146 | 131 | Supply of three phase divector energy meter upto 25 KVA load. | | 1 | Nos |
|---|
| 147 | 132 | Supply, installation, testing and commissioning of 20 Ah 500 watt UPS , power supply, 240 V, 1 Ø input and 240 V, 1 Ø output, along with necessary protections such as, overload, short circuit protection etc. Including connections as required comlplete Job. | | 1 | Nos |
|---|
| 148 | 133 | Supply, installation, testing and commissioning of 12 volt 20 Ah 500 watt UPS battery comlplete Job. | | 1 | Nos |
|---|
| 149 | 134 | Supply, installation, testing and commissioning of Wifi ruter (1+4) complete with input power supply adopter, data cable , Telephone line cable with 2way connector complete Job. | | 1 | Nos |
|---|
| 150 | 135 | Supply, installation, testing and commissioning of 12 way access point with all accessories complete Job. | | 1 | Nos |
|---|
| 151 | 136 | Supply of adopter for Fax mechine, wifi rutor etc. as required. | | 1 | Nos |
|---|
| 152 | 137 | Supply of HDMI cable minimum 10 meter length as required. | | 1 | Nos |
|---|
| 153 | 138 | Supply of UTP CAT 6 LAN cable as required. | | 1 | Mtr |
|---|
| 154 | 139 | Supply, installation, testing & commissioning Telephone Headset with caller ID | | 1 | Mtr |
|---|
| 155 | 140 | Supply , instalation ,testing & commissioning of Dome Camera | | 1 | Mtr |
|---|
| 156 | 141 | Repair & Servicing of Air-conditioner | | | |
|---|
| 157 | 142 | Servicing of 1.5 ton Split / window Air conditioner | | 1 | Nos |
|---|
| 158 | 143 | Supply and Filling of Gas for 1.5 Ton Split Air conditioners | | 1 | Nos |
|---|
| 159 | 144 | Repairing of damaged power circuit board for 1.5 ton Split Air | | 1 | Nos |
|---|
| 160 | 145 | Providing and fixing of damaged swing motor for split air conditioners. Including dismentling of damaged motor. | | 1 | Nos |
|---|
| 161 | 146 | Providing and fixing of damaged running capacitor for Split Air conditioner.Including dismentling of damaged capaciter. | | 1 | Nos |
|---|
| 162 | 147 | Providing and fixing of 2 Ton Split A C 3 star including all accessories as required complete jab. | | 1 | Nos |
|---|
| 163 | 148 | Providing and fixing of 1.5 Ton Split A C 3 star including all accessories as required complete jab. | | 1 | Nos |
|---|
| 164 | 149 | Providing and fixing of 1 Ton Split A C 3 star including all accessories as required complete jab. | | 1 | Nos |
|---|
| 165 | 150 | Providing and fixing of suchtion & discherg copper line including all accessories as required complete jab. | | 1 | ft. |
|---|
| 166 | 151 | Repair & Service of 62.5 KVA DG Set | | | |
|---|
| 167 | 152 | Supply of Service Kit . | | 1 | Nos |
|---|
| 168 | 153 | Supply of Air Cleaner. | | 1 | Nos |
|---|
| 169 | 154 | Supply of Lube oil. | | 1 | Nos |
|---|
| 170 | 155 | Supply of Valve Housing Joint | | 1 | Nos |
|---|
| 171 | 156 | Supply of Coolant Recovery Bottle | | 1 | Nos |
|---|
| 172 | 157 | Supply of Coolant Refilling | | 1 | Nos |
|---|
| 173 | 158 | Supply of AMF Panel controll connector | | 1 | Nos |
|---|
| 174 | 159 | Labour & Service Charges for complete job. | | 1 | Nos |
|---|
| 175 | 160 | Reparing & servicing of Water Purifier ( R O) | | | |
|---|
| 176 | 161 | Supply of Memrien | | 1 | Nos |
|---|
| 177 | 162 | Supply of candle | | 1 | Nos |
|---|
| 178 | 163 | Supply of UV rod | | 1 | Nos |
|---|
| 179 | 164 | Supply of PCB | | 1 | Nos |
|---|
| 180 | 165 | Supply of Pump | | 1 | Nos |
|---|
| 181 | 166 | Labour & Service Charges for water purifier (RO). | | 1 | Nos |
|---|
| 182 | 167 | Supply, installation, testing and commissioning of water purifier (RO + UV+ UF+ Alkaline) ISO 9001-2015 certified company . | | 1 | Nos |
|---|
| 183 | 168 | Labour & Service Charges for day to day maintenance for 180 KVA automatic voltage stablizer. ( But without material) | | 1 | Nos |
|---|
| 184 | 169 | Supply of quardz heat piller . | | 1 | Nos |
|---|
| 185 | 170 | Supply of heat piller rod | | 1 | Nos |
|---|
| 186 | 171 | Supply of hellogen heater 3 rod | | 1 | Nos |
|---|
| 187 | 172 | Supply of hellogen heater 2 rod | | 1 | Nos |
|---|
| 188 | 173 | Supply of hellogen heater rod | | 1 | Nos |
|---|
| 189 | 174 | Supply of Heat convector /Blower | | 1 | Nos |
|---|
| 190 | 175 | Supply of skilled labour for day to day maintenance of electrical network. | | 1 | Job |
|---|
| 191 | 176 | NOTE :- 1) All accessories / apliances / equipments and the entire installation shall be carried out strictly in accordance with the Anexture - C attached to the tender (SBD Page: 11-14). 2) All accessories / apliances / equipments and the entire installation shall be guarantee /warrantee against DLP for a period of 12 months from the successful completion of said job 3) Material mentioned above will be supplied as per the Requirements which may vary at the time of actual execution of the work and shall be allowed as per actual with in the estimated cost. | | | |
|---|