Provision Of Hard Standing Alongwith Associated Works For Solid Waste Management , Hard Standing Near Bldg No . P-86 For Parking Of Service Vehicle And Special Repair To Internal Wiring And Exhaust Fan At Smq ( P-30 Block ) At Af Station Kurseong Under, GE AF Bagdogra-West Bengal

Military Engineer Services-MES has published Provision Of Hard Standing Alongwith Associated Works For Solid Waste Management , Hard Standing Near Bldg No . P-86 For Parking Of Service Vehicle And Special Repair To Internal Wiring And Exhaust Fan At Smq ( P-30 Block ) At Af Station Kurseong Under. Submission Date for this Tender is 27-04-2021. Ceiling Fan Tenders in GE AF Bagdogra West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27600791
Provision Of Hard Standing Alongwith Associated Works For Solid Waste Management , Hard Standing Near Bldg No . P-86 For Parking Of Service Vehicle And Special Repair To Internal Wiring And Exhaust Fan At Smq ( P-30 Block ) At Af Station Kurseong Under
Open Tender
Indian
West Bengal
GE AF Bagdogra
27-04-2021

Tender Details

Provision Of Hard Standing Alongwith Associated Works For Solid Waste Management , Hard Standing Near Bldg No . P-86 For Parking Of Service Vehicle And Special Repair To Internal Wiring And Exhaust Fan At Smq ( P-30 Block ) At Af Station Kurseong Under Ge ( Af

Key Value

Document Fees
INR 500 /-
EMD
INR 34800.0 /-
Tender Value
INR 17.40 Lakhs /-

BOQ Items

Name of Work: Provn of hard standing alongwith associated works for solid waste management, hard standing near Bldg No.P-86 for parking of service vehicle and special repair to internal wiring and exhaust fan at SMQ P-30 Block at AF Stn Kurseong under GE Air Force Bagdgora
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n.exc 1.5m width and n.exc 1.5 m depth and getting out in hard/dense soil. 19.45 Cum
2 2 M&L for PCC 1:4:8, type D-2 (using 40mm graded aggregate) as in foundations all as specified. 2.8 Cum
3 3 Returning and filling in with soil obtained from excavation in layers n exc 25cm thick including watering, ramming etc all as specified. 3.9 Cum
4 4 Removal of excavated soil to a distance 50mtr and depositing where directed at a level n exc 1.50m above the starting point as specified and as directed. 15.55 Cum
5 5 M&L for steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240 all as specified. 1400 Kg
6 6 S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc.. n exc10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified. 40 Kg
7 7 S&F 5 to 10mm dia of neck Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified. 10 Kg
8 8 S&F Pre- painted (No Suggestions) aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550 Map as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. 100 Sqm
9 9 M&L for two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface exceeding 10cm in width or girth,not all as specified. 10 Sqm
10 10 Surface excavation n exc 30 cm deep and average 15 cm deep and getting out hard and dense soil. 327 Sqm
11 11 M&L for Hard core of broken stone boulders gauge n exc 63mm,deposited,spread and levelled in layers n exc 15 cm thick,watered and rammed to a true surface. 32.7 Cum
12 12 M&L for 75mm thick, plain cement concrete, Type B-1,,1:4:8(using 40mm graded stone aggregate) as in sub base complete all as specified. 84 Sqm
13 13 M&L for 50mm thick plain cement concrete Type B-1,1:2:4(using 20mm graded aggregate) as in floor finishes surface finished even and smooth with out using extra cement complete all as specified. 84 Sqm
14 14 M&L for brick work with subclass 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 all as specified. 12 Cum
15 15 M&L for 15mm thick rendering on other than fair faces of brick work or concrete surface built in cement mortar 1:4, surface finished fair and even complete as specified and directed 50 Sqm
16 16 M&L for applying two coat of cement base paint over a coat of alkali resistant primer on wall including preparation of new plastered surfaces all as specified. 50 Sqm
17 17 M&L for rendering 10mm thick in CM1:6on fair faces of brick work or concrete surface including finishing the surface even and smooth without using extra coat all as specified. 50 Sqm
18 18 M& L for for applying 3 coats of white wash on newly plastering wall surfaces including preparation of surfaces all as specified . 50 Sqm
19 19 M&L for 100mm thick, PCC (1:4:8), Type D2, (using 40mm graded stone aggregate) as in sub floor all as specified. 243 Sqm
20 20 M&L for 130 mm thick PCC, type A-1 (using 20 mm graded stone aggregate), Grade mix(by volume) 1:1 1/2 : 3 (Nominal mix concrete) as in base layer floor laid in panels including finishing the surface fair and even without using extra cement and all the preparation to receive wear proof topping complete all as specified and directed. 155 Sqm
21 21 M&L for 20 mm thick wear proof floor topping using approved metallic floor hardener as per manufacturer's instructions laid over concrete base layer flooring while base layer is still green and finished even and smooth (Metallic floor hardener shall be measured and paid separately as supplied only) 155 Sqm
22 22 Supply only metallic floor hardener all as specified and directed.\n\nMake: Ironite, Stillonite, Hardonate & Fosroc 1550 Kg
23 23 M&L for forming construction joint, 30 mm deep x 10 mm wide filled with sealing compound Grade 'B' all as specified and directed. 3.6 10RM
24 24 M&L for Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'B' all as specified and directed. 8.1 10RM
25 25 M&L for pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, M-35 Grade with grey cement and pigment, glossy finished including sand cushioning 25mm thick spread over. 88 Sqm
26 26 Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete along with fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc as specified & directed. 107 Point
27 27 M& L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metallic bodies of luminaires/ fan at other end complete all as specified and directed for one light point/one exhaust fan point controlled by one, one way switch. \nNote: Unit rate include for cutting chases for conduits and sinking of boxes and making good to wall,floors etc 58 Point
28 28 All as per item No.27 above, but for one 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. 8 Point
29 29 All as per item No.27 above, but for one call bell/buzzer point controlled by one bell push. 4 Point
30 30 All as per ser item No. 27 above but for 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes. 20 Point
31 31 All as per ser item No. 27 above but on independent board. 16 Point
32 32 All as per ser item No. 27 above but for one light point controlled by 2 way switches. 1 Point
33 33 Supply and fixing in replacement of socket outlet flush type, 5 pin, 5 Amp multipurpose 230 volts single pole, one way, suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed. 8 Each
34 34 Supply and fixing in replacement of switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed. 16 Each
35 35 Supply and fixing in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 3 pin ) 5/15 Amps, 230V, AC all as specified and directed. 20 Each
36 36 Supply and fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified. 8 Each
37 37 Supply and fix in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish. 62 Each
38 38 S & F call bell/buzzer ding dong, AC 230V, single pole complete all as specified and as directed. 4 Each
39 39 S & F Modular bell push, one way, 6 Amp, 1 Module, 240 volt, ISI marked complete all as specified and as directed. 4 Each
40 40 Supply and fixing in replacement of switch piano flush button 5 Amp single pole 2 way 230 volts white finish all as specified & directed. 58 Each
41 41 Supply and fix in replacement LED tube light FOUR feet along with fixture, 20 W T8 tubular lamp with aluminium Extruded aluminium/PC Body Pc Diffuser complete with inbuilt driver along with batten with blue coloured end caps. 28 Each
42 42 Supply and fix in replacement LED Tube light TWO feet along with fixture, 10 W lamp with aluminium Extruded aluminium/PC Body Pc Diffuser complete with inbuilt driver all in one fixtures. \n 24 Each
43 43 Supply & fixing in replacement of Pressure Die cast housing LED bulkhead 10 Watt with IP65 Protection and IK09 impact resistance suitable for surface and wall mounting applications.\n 2 Each
44 44 Supply and fix in replacement Plastic plug socket 16 A 3 pin P+E+N single phase 240 Suitable for surface mounting conforms to IS:8623 \n 4 Each
45 45 Supply and fixing exhaust fan with automatic back shutter louvers 250 mm sweep, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan including writing of MES Number (2.0 cm height) with synthetic enamel paint complete all as specified & as directed with following specification Sweep : 250mm, Power : 34W, Air Delivery : 810 CMH, RPM: 1100 Make:Bajaj Maxima DX 250 mm Exhaust Fan (White) or equivalent Model in Havells, CG, Almonard.\n 4 Each
46 46 Supply and fixing in replacement of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. \nNote:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. \n(ii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. 80 RM
47 47 Supply and fix in replacement distribution board sheet metal enclosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed. 4 Each
48 48 Supply and fix in replacement distribution board sheet metal enclosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting MCB with front openable cover suitable for TP & N 4 ways all as specified & directed. 1 Each
49 49 Supply and Fixing of MCB TPN 63Amps, 415 Volts, 50 Hz with 10 KA 1 Each
50 50 Supply and Fixing in replacement of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA . 24 Each
51 51 Supply and Fixing in replacement of MCB SPN/DP 6-32 Amps, 230 Volts, 50 Hz with 10 KA. 8 Each
52 52 S & F RCBO for earth-leakage, overload & short-circuit protection, four pole, 63 A, sensitivity 300 mA, 10KA, ISI marked incl indication of fault protection complete all as specified. 1 Each
53 53 M & L for Earthling complete with galvanized Copper earth plate electrode 60 cm X 60 cm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Copper earth strip 20 x3 mm, by means nut bolt, nuts, check nuts and washer and protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I, 2009 and connection to earth test point all as specified incl testing on completion” including taking down existing earthing complete all as specified. 2 Each
54 54 NOTES :-\n1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.\n2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule A notes for details.\n