| 1 | 1 | Repairing of 8Mtr Mini Mast Lights at Thannimoodu, Kochupalli and Nellimoodu in Athiyannur Grama Pachayat | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | BI01010001010000000000000515BI0100001114 | 54 | mtr |
|---|
| 3 | 1.02 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001115 | 3 | nos |
|---|
| 4 | 1.03 | Digital timer | BI01010001010000000000000515BI0100001116 | 3 | nos |
|---|
| 5 | 1.04 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001117 | 3 | nos |
|---|
| 6 | 1.05 | 32A 2-way neutral links mounted\non DMC/SMC base | BI01010001010000000000000515BI0100001118 | 3 | nos |
|---|
| 7 | 1.06 | Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001119 | 18 | nos |
|---|
| 8 | 2 | Repair and Relocation of 12 Mtr High Mast Light at Kamukinkode in Athiyannur Grama Pachayat | BI01010001010000000000000515BI0100001120 | | |
|---|
| 9 | 2.01 | Labour charges for dismantling of High Mast Pole from existing foundation and fixing on new foundation including Crane charges | BI01010001010000000000000515BI0100001121 | 1 | nos |
|---|
| 10 | 2.02 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | BI01010001010000000000000515BI0100001122 | 18 | mtr |
|---|
| 11 | 2.03 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. | BI01010001010000000000000515BI0100001123 | 2 | nos |
|---|
| 12 | 2.04 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001124 | 1 | nos |
|---|
| 13 | 2.05 | Digital timer | BI01010001010000000000000515BI0100001125 | 1 | nos |
|---|
| 14 | 2.06 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001126 | 1 | nos |
|---|
| 15 | 2.07 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole | BI01010001010000000000000515BI0100001127 | 1 | nos |
|---|
| 16 | 2.08 | Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001128 | 6 | nos |
|---|
| 17 | 2.09 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.\n3 core 10 sq mm | BI01010001010000000000000515BI0100001129 | 50 | mtr |
|---|