Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh, KALKA-Haryana

Military Engineer Services-MES has published Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh. Submission Date for this Tender is 29-04-2021. Air Conditioner Tenders in KALKA Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27585529
Corrigendum : Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh
National Competitive Bid
Indian
Haryana
KALKA
29-04-2021

Tender Details

Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Apr-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-04-2021

Key Value

Document Fees
INR 300 /-
EMD
INR 7200.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR MAINTENANCE OF SUMMER APPLIANCES AND OTHER MISC WORK AT MIL STN KALKA UNDER GE JUTOGH.
Sl. No. Item Description Item Code / Make Qty Units
1 1 CEILING FAN
2 1.01 M&L for servicing of ceiling fans, any sweep/size at existing position from various locations for maintenance after removing cable connection from ceiling rose, checking, tightening of thread of down rod, opening of fan, greasing/oiling of bush/ bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin, lock bolt, condensor clamp check nut and cable flexible from ceiling rose to ceiling fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items 300 Each
3 2 Supply only following component suitable for ceiling fan :-
4 2.01 Ball bearing as per sample suitable for ceiling fan complete all as specified and directed. 70 Each
5 2.02 Capacitor of 2.5 Mfd complete all as specified and directed. 250 Each
6 2.03 Gun metal bush as per sample complete all as specified and directed. 70 Each
7 2.04 Ceiling fan blade as per sample set of three suitable for 1200mm sweep fan complete all as specified and directed.. 10 Each
8 3 M&L for rewinding of ceiling fan with appropriate gauge size super enameled copper wire including necessary insulation material after cleaning of stator for 1200/1400 mm sweep ceiling fans complete all as specified and directed. 150 Each Job
9 4 Exhaust Fan
10 4.01 M&L for servicing of exhaust fans, any sweep/size at existing position from various location for maintenance after removing cable connection from ceiling rose, checking, tightening of nuts, bolts, opening of fan, greasing/oiling of bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin and cable flexible from ceiling rose to exhaust fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items 50 Each Job
11 5 Supply only following items for exhaust fan:-
12 5.01 Capacitor 4 Mfd, 230 Volt 50 Each
13 5.02 Ball bearing as per sample suitable for exhaust fan 30 Each
14 5.03 Exhaust fan blade of any sweep with screws/bolts, nuts. 10 Each
15 5.04 Exhaust fan louvers complete with nut & bolts etc. 30 Each
16 6 M&L for rewinding exhaust fan 300/400 mm sweep startor with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed. 40 Each Job
17 7 PEDESTAL FAN
18 7.01 M&L for servicing of Wall Fan/Pedestal fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required with and including re-assembling after replacement of defective components/ repair and replacing of minor items such as clamp, back cover, screw lock, nuts, welding guards etc testing for its smooth functioning complete all as specified and directed.\nNote: Spare parts will be measured and paid separately under respective item of Sch ‘A’.\n 5 Each Job
19 8 Supply only following items for pedestal fans:-
20 8.01 Gun metal bush as per existing size. 2 Each
21 8.02 Capacitor 4 Mfd, 230 Volts 2 Each
22 8.03 Fan blade assembly suitable for wall/pedestal fan 1 Each
23 9 M&L for rewinding Wall Fan/Pedestal Fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for wall fan/padestal fan complete all as specified and directed. 1 Each Job
24 10 WATER COOLER
25 10.01 M&L for Servicing of water cooler of any make & type of capacity 40/80 by disconnecting electrically & mechanically,from various location for repair and maintenence including cleaning condenser coil and storage tank with chemical base solution and soda water and repalcement of unserviceable parts and refixing , re-connecting electrical and water connections, testing complete all as specified and directed. Note :- New components/parts shall be measured and paid separately under respective items 8 Each Job
26 11 Supply only following item for water cooler complete all as directed :-
27 11.01 Starting capacitor 40-60 MFD 3 Each
28 11.02 Starting relay(as per sample) 3 Each
29 11.03 Running capacitor 10 MFD 3 Each
30 11.04 Thermostate as per sample 3 Each
31 11.05 PVC float valve with PVC ball ,15mm dia (as per sample). 4 Each
32 12 S&F in replacement sealed unit compressor unit single phase, 230 V and for water cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc, Supply and charging of refrigerant gas of adequate quantity complete and testing incl taking down the old U/S sealed unit compessor all as specified and & directed for the 40/80 Ltrs capacity complete all as specified and directed. 2 Each
33 13 S&F of condensor coil complete with copper tube and aluminium fins for water cooler of cap upto 80 Ltrs with and including necessary refrigerant gas charging etc including testing complete all as specified and directed. 1 Each Job
34 14 S&F of sheet metal enclosures with 2 pins and earth plug single pole neutral link and one Nos MCB SP 32 amp complete including taking out existing and make connection with the new complete all as specified and directed. 4 Each
35 15 S&F in replacement of FHP motor single phase suitable for 40/80 ltrs capacity as per existing complete all as specified and directed. 2 Each
36 16 M&L for charging with refrigerant gas suiatble for water cooler, checking and testing the leakage from the system of any cap complete all as specified and directed. 2 Each Job
37 17 REFRIGERATOR
38 17.01 M&L for servicing of refrigerator of any make and capacity from various location for maintenance including taking out old unserviceable parts and replacing with new parts and re-install the same at existing place after repairing, servicing and testing complete all as specified and directed. Note :-Spare parts shall be measured & paid separately for as supply only. 6 Each
39 18 Supply only following items for refrigerator complete all as directed:-
40 18.01 Thermostate (as per sample) 2 Each
41 18.02 Thermostate switch as per sample 2 Each
42 18.03 Relay as per existing. 2 Each
43 19 S&F in replacement new sealed unit compressor capacity of 265/300/310 ltr in replacement, welding the same with existing refrigerant pipe, leakage testing/vaccum test, supply & charging of refrigerant gas of adequate quantity testing complete incl taking down the old U/S sealed unit compressor from refrigerator andcomplete all as specified and directed. 1 Each
44 20 S&F in replacement of new condenser coil suitable for 265 to 310 ltrs capacity refrigerator including Welding/brazing of pipe lines, cahrging of refrigerant gas and testing complete all as specified and directed. 1 Each
45 21 M&L for charging with refrigerant gas suiatble for refrigerator, checking and testing the leakage from the system of any cap complete all as specified and directed. 2 Each Job
46 22 DEEP FREEZER
47 22.01 M&L for servicing of deep freezer of capacity 262 to 425 ltr from various location , cleaning the complete condenser coil & storage tank with chemical base solution and soda water complete restoring electrical connection and testing complete all as specified and directed. Note :- Parts to be replaced shall be measured and paid separately under respective items of schedule 'A'. 6 Each Job
48 23 Supply only following item for deep freezer complete all as directed :-
49 23.01 Starting capacitor 80/100 MFD 2 Each
50 23.02 Running capacitor 30 MFD 2 Each
51 23.03 Starting relay as per existing 2 Each
52 24 S&F in replacement of sealed unit compressor hermatically company sealed suitable for deep freezer of capacity 315 to 425 Ltr, single phase, 230 V and welding/ brazing of gas pipe line, vaccume pressure leakage testing etc including charging of adequate quantity of regrigerant gas , welding/brazing of copper pipe & testing complete all as directed.\nNote:- Old compressor unit will be the property of contractor as per schedule of credit. 1 Each Job
53 25 M&L for charging with refrigerant gas suiatble for deep freezer, checking and testing the leakage with the help of nitrogen gas and repairing the same by brazing etc compleate all as specified. 2 Each Job
54 26 DESERT COOLER
55 26.01 M&L for Servicing of desert coolers of any size/any height by taking down from the existing position,cleaning of bottom tank, side panel etc including repair/replacing unserviceable parts complete all as specified and directed. Note:-Spares parts required shall be measured and paid separatley under respective item of schedule 'A' as supply only. 50 Each Job
56 27 Supply only the following items suitable for desert cooler complete all as directed :-
57 27.01 Capacitor 4 MFD, 35 Each
58 27.02 PVC Pipe transparent heavy duty ½ inch dia set for three side of desert cooler complete. 15 Set
59 27.03 Wood wool pad 15mm thick made out of chicken wire mesh fitted with fine quality wood wool , bind with GI wire for desert cooler as per site reqmt complete. 50 Set of three
60 27.04 Submersible water lifting pump for desert cooler 220/230 V single phase Make - Bansal / summer cool or equiv 25 Each
61 27.05 Fan motor for 18'' sweep with blade complete suitable for desert cooler Make:- Khaitan/CG/Orient 15 Each
62 27.06 Selector switch (rotory type) 3 speed, 230 V, 50 C/S suitable for desert cooler 20 Each
63 27.07 S&F Plug top 5 Amps, 230 Volts,50Hz complete all as specified and directed. 20 Each
64 27.08 M&L for spray painting of desert cooler with one coat synthetic enamel paint incl preparation of surface, cleaning of old paint on internal & external surface complete all as specified and directed. 7 Each Job
65 28 S & F in repair single pole and neutral sheet duly powder coated distribution board for MCBs fitted with bus bar , Neutral link ,earth bar and din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as specified and directed. 5 Each
66 29 S&F in repair MCB TPN 40 to 63 Amps, 10KA,415V incl all termnials, fitting etc. complete all as specified and directed. 10 Each
67 30 S&F in repair MCB SPN 32 Amps, 10KA, 250V incl all termnials, fitting etc. complete all as specified and directed. 12 Each
68 31 S&F in replacement MCB SP 6-32 Amp, 10 KA,240 Volt complete all as specified and directed. 20 Each
69 32 S&F in replacement energy efficient LED batten integrated type with LED tube 20 Watt, 4 ft long white complete with LED driver and LED batten with extruded aluminium/PC Body and PC diffuser including all accessories pre wire and connecting up with copper three core flexible wire complete all as directed. Make:- Bajaj cat ref BCLSB 20 WH/ Havells Cat part No LUMILINEPLUSBS20WLED865SPCSS/ Polycab Cat part No LDO0103023/ Crompton cat part No LCCLB-24-CDL 50 Each
70 33 S&F in repair LED bulb 9 watt complete all as specified and directed. 20 Each
71 34 S&F in repair electric fan regulator step type, 230V, AC, complete all as specified and directed. 100 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail