| 1 | 1 | Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/280 Ltr. Capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized dealer | | 1 | EACH |
|---|
| 2 | 2 | Material and labour for replacement of relay suitable for 280/310 Liters cap.refrigerator (Make:- Renutrol/Shriram/Anna purna/KLIXON) | | 2 | EACH |
|---|
| 3 | 3 | Material and labour for replacement of thermostat automatic `R' frost with knob suitable for 165/286/310 liters cap refrigerator (Make :-Anna purna/Indofos) | | 1 | EACH |
|---|
| 4 | 4 | Material and labour for replacement of door gasket of best quality complete suitable for 280/310 liters cap. refrigerator as per manufacturer's instruction and as directed by EIC. | | 1 | EACH |
|---|
| 5 | 5 | Material and labour bulb pin /screw type , 230 Volts suitable for 286/310 Ltrs Cap. refrigerator as in replacement. | | 1 | EACH |
|---|
| 6 | 6 | Material and labour for replacement of freezer door incl. necessary door springs, screws etc. for 280/310 Ltrs. Cap. Refrigerator complete all as specified and directed by EIC. | | 1 | EACH |
|---|
| 7 | 7 | Material and labour for replacement of door lock for any capacity of refrigerator as per sample approved by EIC | | 1 | EACH |
|---|
| 8 | 8 | Material and labour for replacement of PVC chill tray suitable for 280/310 Ltrs Cap. refrigerator complete of matching colour. | | 4 | EACH |
|---|
| 9 | 9 | Material and labour for replacement of refrigerator door handle of 165/ 286/310 Ltrs Cap. of any make.and model | | 2 | EACH |
|---|
| 10 | 10 | Material and labour for replacement of freezer assy (including gas charging ) complete with screw, jointing of tubes etc. and testing of cap. 280/310 Ltrs. refrigerator (any make) | | 2 | EACH |
|---|
| 11 | 11 | Material and labour for replacement of condensor unit of refrigerator cap. 280/310 Ltrs of any make incl. jointing of tubes and testing etc. complete.(gas charging will be measure and paint under relevant item separately ) | | 1 | EACH |
|---|
| 12 | 12 | Material and labour for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model | | 10 | EACH |
|---|
| 13 | 13 | Material and labour for replacement of unserviceable cut sealed compressor of split type ACs 2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model | | 15 | EACH |
|---|
| 14 | 14 | Material and labour for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of cap. 1/5HP any make with super enameled copper conductor including replacement of worn out bushes, Shaft and capacitor etc and testing complete. Make of winding wire:- Atlas/Chetak/Devidayal). | | 20 | EACH |
|---|
| 15 | 15 | Material and labour for replacement of condensor fan motor of Speed 900 RPM of window/Split Air conditioner of cap. 1/5HP | | 10 | EACH |
|---|
| 16 | 16 | Supply and fixing running capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5 Ton Cap. (Make:- Escop/Kell/Tesla/Sharda) | | 35 | EACH |
|---|
| 17 | 17 | Supply and fixing starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for window type /Split type air conditioner (Make:- Kell/Tesla/Sharda/Escop) | | 10 | EACH |
|---|
| 18 | 18 | Supply and fixing running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles for window type/split type air conditioner 2 Ton Cap. (Make:- Escop/Kell/Tesla/Sharda) | | 25 | EACH |
|---|
| 19 | 19 | Supply and fixing starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for window type/split type air conditioner (Make:- Kell/Tesla/Sharda/Escop) | | 5 | EACH |
|---|
| 20 | 20 | Supply and fixing over load protector with relay No 1622/2085 (Make:- Shri Ram/Renutral) for 1.5 Ton cap for window type AC. | | 6 | EACH |
|---|
| 21 | 21 | Material and labour for replacement of thermostat switch for AC cap.1.5/2.00 ton capacity. (Make:- Anupurna/Indofost No 2059/Ranutrol) | | 4 | EACH |
|---|
| 22 | 22 | Material and labour for replacement of defective wiring set (with suitable copper wire) of window type AC cap. 1.5 Ton/2 Ton complete all as directed by EIC. | | 4 | EACH |
|---|
| 23 | 23 | Material and labour for flushing out system , checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction of Engineer-in-Charge.Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost. | | 40 | EACH |
|---|
| 24 | 24 | Material and labour for replacement of cooling coil for window type AC Cap.1.5 /2.0 TR | | 2 | EACH |
|---|
| 25 | 25 | M & L for replacement of blade of condensing fan motor (as per sample) for window type AC cap 1.5 Ton. (any make) | | 2 | EACH |
|---|
| 26 | 26 | M & L for replacement of blower for AC cap. 1.5 Ton/2ton (as per sample) | | 4 | EACH |
|---|
| 27 | 27 | Material and labour for taking out window type AC from site of any cap.and make for servicing incl. cleaning with air blower , cleaning and washing fins of cooling coil with caustic soda mixed water, taking out all dirt , sludge deposited, cleaning of air filter incl. oiling / greasing of condensing fan motor , spray painting of outer cover with 2 coats of synthetic enameled paint of approved colour as directed with writing of serial No SM/MES No. and reinstalled the AC in position with fixing of putty etc. complete all as directed by EIC.(Note : If any damage occurred during repair contractor will be responsible to rectify defects without any cost to the Govt). | | 3 | EACH |
|---|
| 28 | 28 | Material and labour for servicing /overhauling of split type AC unit cap. 1.5 Ton incl. painting to outer cover and components with two coats of synthetic enameled paintof colour as directed) complete incl. following: | | 70 | EACH JOB |
|---|
| 29 | 28.01 | Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. | | | |
|---|
| 30 | 28.02 | Greasing / oiling of blower fan motor. | | | |
|---|
| 31 | 28.03 | Charging the gas as required to full fill the rated cooling effect. | | | |
|---|
| 32 | 29 | Description all as per ser item No.28 above but 2 TR Split type AC | | 60 | EACH JOB |
|---|
| 33 | 30 | Supply only in replacement of following U/s items in split type AC: | | | |
|---|
| 34 | 30.01 | Connector unit | | 30 | EACH |
|---|
| 35 | 30.02 | Blade for condensing fan motor | | 10 | EACH |
|---|
| 36 | 30.03 | Foam type insulating flexible pipe fitted on suction /discharge copper tubes. | | 300 | RM |
|---|
| 37 | 30.04 | PCB Card for split type AC of capacity 1.5 TR | | 15 | EACH |
|---|
| 38 | 30.05 | PCB Card for split type AC of capacity 2 TR | | 20 | EACH |
|---|
| 39 | 30.06 | Remote hand set for split type AC 1.5/2 TR Capacity | | 15 | EACH |
|---|
| 40 | 30.07 | Valve 1/2 \" ,1/4 \" and 5/8 \" for split type of capacity 1.5 TR | | 5 | EACH |
|---|
| 41 | 30.08 | Cooling coil and room temperature sensor | | 15 | EACH |
|---|
| 42 | 30.09 | Display unit for 1.5/2 Ton AC | | 10 | EACH |
|---|
| 43 | 31 | Material and labour for replacement of blower motor of indoor unit of split type of cap 1.5 /2 TR as per existing make/model | | 10 | EACH |
|---|
| 44 | 32 | Material and labour for replacement of copper pipe of size 1/4 \" from outdoor unit to indoor unit including soldering and brazing | | 30 | RM |
|---|
| 45 | 33 | Material and labour for replacement of copper pipe of size 1/2 \" from outdoor unit to indoor unit including soldering and brazing | | 30 | RM |
|---|
| 46 | 34 | Material and labour for replacement of copper pipe of size 5/8 \" from outdoor unit to indoor unit including soldering and brazing | | 60 | RM |
|---|
| 47 | 35 | Material and labour for disconnection and refixing split type of capacity 1.5/2 TR from one site to another site including drilling, making hole/ making good the disturbed surface and old place hole filling by white cement or putty/ anchor hold fastener/screws complete all as directed by Engr-in-charge | | 20 | EACH JOB |
|---|
| 48 | 36 | Material and labour for PT relay for split type Acs of Capacity 1.5/2 TR as per existing make | | 8 | EACH |
|---|
| 49 | 37 | M & L in replacement sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit as required including accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed all as directed.\nNote: 2 Runs of 6sqmm cable, one run of 4 sqmm cable and PVC counduit/casing caping measured as one unit. | | 120 | RM |
|---|
| 50 | 38 | Supply and fixing in repairs single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 25 Amps (Make- Legrand/C&S/Havells). | | 25 | EACH |
|---|
| 51 | 39 | Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete.(Makes :-Tecumesh/Kirlosker copeland ) | | 5 | Each |
|---|
| 52 | 39.01 | Note Old sealed compressor received from the water cooler will be property of contractor (ii) The rate quoted by the contractor includes all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition. (ii ) The new sealed unit will be purchased from authorized dealer | | | |
|---|
| 53 | 40 | Material and Labour for Replacement of copper filter and capillary tube. of water cooler cooling capacity 40 Ltr/hr | | 5 | Each |
|---|
| 54 | 41 | Material and Labour for Replacement of relay with over load protectors for 40 Ltr/hr cooling capacity suitable as per site requirement ( Make :Ranutrol/Rockwell/ Annapurna ) | | 3 | Each |
|---|
| 55 | 42 | Material and Labour for Replacement of condensor fan of motor HP- 1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade. | | 2 | Each |
|---|
| 56 | 43 | Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs / hr (Make : Renutrol no 1051 or Indofoss No2064/Annapurna ) | | 3 | Each |
|---|
| 57 | 44 | Material and Labour for repair work of worn out of patch work of MS body of water cooler any capacity made out 22 gauge mild steel sheet 0.25 Sqm and making good with paint to match with existing .all as specified and directed by Engineer-in-Charge. Note: Rates for patch work either on site or transporting to workshop deemed to be included in quoted rates. | | 3 | Each Job |
|---|
| 58 | 45 | Material and Labour for replacement of PVC pipe, 25 mm bore 70 cms in length with two Nos mild steel clamps and necessary brass screws etc. all as directed | | 10 | Each Job |
|---|
| 59 | 46 | Material and Labour for replacement of drip tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI and PVC connection arrangement. all as directed ( as per sample ) | | 3 | Each |
|---|
| 60 | 47 | Material and Labour for replacement of rubber beading fixed with top cover of water cooler of 40 liters/hour capacity. | | 5 | Each |
|---|
| 61 | 48 | Material and Labour for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and fixing on the existing base all as specified and directed by Engineer-in-Charge | | 3 | Each |
|---|
| 62 | 49 | Supply and fixed push cock, 15mm bore self closing vertical type made of brass nickle chromium plated- Make Mayor/ C-Sons/G-Sons | | 5 | Each |
|---|
| 63 | 50 | Material and Labour for replacement of connectors made of brass nickle chromium plated suitable for water cooler having cooling capacity 40 litresper hour | | 5 | Each |
|---|
| 64 | 51 | Material and Labour for painting to water cooler of cap. 40 / 60 Ltrs/hour spray painting with two coats of synthetic enamel paint (first quality) and preparation of surface including cleaning and washing condenser all as specified & directed by Engineer-in-Charge and writing of words for example SM No.137777,MES No NR 87995 etc ( NOTE :Repair to be done by the contractor at various location of units as directed) | | 5 | Each\n Job |
|---|
| 65 | 52 | Material and Labour for Replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply Make ; Tesla | | 4 | Each |
|---|
| 66 | 53 | Material and Labour for Replacement of running capacitor of 10 Mfd oil filled Make: Asian/ Atlas/Epcos/SPAN/Sharda | | 5 | Each |
|---|
| 67 | 54 | Material and Labour for Replacement of capacitor of 3 Mfd Make: Asian/ Atlas/Epcos/SPAN | | 5 | Each |
|---|
| 68 | 55 | Material and Labour in replacement brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple as directed by Engineer -In -charge | | 5 | Each |
|---|
| 69 | 56 | Material and Labour for replacement of top cover of water cooler with rubber beading, hinges screws etc complete for 40 Ltr/Hr cap. water cooler all as specified and directed by Engineer -in-charge.(As per sample) | | 2 | Each |
|---|
| 70 | 57 | Material and Labour for flushing of system and repairs of leakages in system charging of Gas , Oil complete incl. testing and commissioning of water cooler having cooling Capacity. 40 Ltrs.per hour. of any make. | | 4 | Each Job |
|---|
| 71 | 58 | Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with supper enameled copper wire of suitable gauge (Make: Devidayal/Chetak/Atlat complete incl. insulating material and replacement of gun metal bush & capacitor 2.5 MFD. \n(Make:Epcos/Asian /Unistar) | | 2 | Each |
|---|
| 72 | 59 | Material and labour for replacement of fan blade for condensing fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/Hr water cooler. | | 2 | Each |
|---|
| 73 | 60 | Material and Labour for condenser unit complete suitable for 40 Ltr/Hr cap. water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge | | 2 | Each Job |
|---|
| 74 | 61 | Material and Labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 48/0.20 cross sectional area superior quality . Make:Plaza/Finolex/Polycab | | 30 | RM |
|---|
| 75 | 62 | Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size . Make: DEVIDAYAL /CHETAK complete incl. replacement of bush, shaft and oil filled capacitor 4 MFD,240 volts of Make: Unistar / Kell/ Asian/ Siemens. | | 15 | Each |
|---|
| 76 | 63 | Material and labour for replacement of front grill (moveable) of the Desert Cooler made out of 20 gauge PGI sheet complete incl. Selector switch with knob,indicator etc. Suitable for 4000 /5000 cfm Desert Cooler or as approved by EIC | | 10 | Each |
|---|
| 77 | 64 | Material and Labour for replacment of Bottom water tank of size 750x750x200 mm fabricated out of 18 gauge PGI sheet.incl nuts bolts and washers etc | | 10 | Each Job |
|---|
| 78 | 65 | Material and labour for replacement of side supporting columns to be fabricated out of 20 gauges PGI sheet of size 80x80x800 mm incl. necessary nut, bolts etc .or as directed by EIC. | | 10 | Each Job |
|---|
| 79 | 66 | Material and labour for replacement of side penal made out of 22 gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler all as directed by EIC. (As per sample) | | 30 | Each Job |
|---|
| 80 | 67 | Material and labour for replacement of top cover made out of 22 gauge PGI Sheet including painting to match with the existing desert cooler all as directed by EIC. (As per sample) | | 10 | Each Job |
|---|
| 81 | 68 | Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed by engineer-in-Charge at site and office yard | | 35 | Each |
|---|
| 82 | 69 | Material and labour for replacement of Desert Cooler fan motor cap. 1/5 HP three speed, 1400 RPM single phase with fan blade, stand and selector switch. Make: Crompton/ GEC/COOL HOME. | | 30 | Each |
|---|
| 83 | 70 | Material and labour replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt | | 30 | Each |
|---|
| 84 | 71 | Material and labour for replacement of Wood / wool chips pad for Desert Cooler of size 400 x 550 x30 mm (set of three pads) superior quality . | | 50 | Each Set of three |
|---|
| 85 | 72 | Material and labour for replacement of supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers complete. | | 30 | Each Set of three |
|---|
| 86 | 73 | Material and labour for replacement of selector switch with knob three speed for D/C fan motor . | | 30 | Each |
|---|
| 87 | 74 | Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area superior quality . | | 75 | RM |
|---|
| 88 | 75 | Material and labour for replacement of PVC water distributor of 3 out lets with MS nuts & bolts complete (as per sample) | | 30 | Each |
|---|
| 89 | 76 | Material and labour for replacement of PVC elbow suitable for desert cooler (as per sample) | | 40 | Each |
|---|
| 90 | 77 | Material and labour for replacement of PVC pipe 15 mm dia heavy duty for D/Cooler Pump (Make:prayag) | | 90 | RM |
|---|
| 91 | 78 | Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz Make :Legrand / M K/Anchor | | 30 | Each |
|---|
| 92 | 79 | Material and labour for replacement of motor fixing ring for desert cooler eight screw / clip type(asper sample) | | 20 | Each |
|---|
| 93 | 80 | Material only for replacement of Outer Body of desert cooler including side panels(3 Nos) and front control panel(steel)(asper sample given by Engr-In-Charge)Note: rates for transportation upto site deemed to be included in quoted rates. | | 20 | Each |
|---|
| 94 | 81 | labour only including necessary nut bolts for taking out inner assembly including everything, fan motor, PVC piping assembly, grass pad, submersible motor and any other item from worn out body of desert cooler and fixing in new body and testing it for effective working complete all as directed by Engr-in-Charge. | | 20 | Each |
|---|
| 95 | 82 | Material and labour for replacement of Desert Cooler fan blades suitable for upto 450 mm sweep fan of any make & type as directed & specified. | | 20 | Each |
|---|
| 96 | 83 | Supply and fix in repair voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.\nMake: V guard VND 500 or equivalent in blue bird or microtech.\nNote: rates for fixing of existing ACs and power supply via volatge stabilizer deemed to be considered in quoted rates. | | 5 | Each |
|---|
| 97 | 84 | Material and labour for taking out deep frezzer of any size and any make to the workshop for general body work repairs including patch work and hinges and locking work complete after removing rusted part and repairing complete fabrication work what ever is required complete making it in good presentable condition and painting work complete all as specified and directed by EIC.Note: Rates for transportation to and fro from site to workshop shall be deemed to be considered in quoted rates. | | 1 | Each |
|---|
| 98 | 85 | Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas (between inner cooling cabin and outer fabrication) , Oil complete incl. testing and commissioning of deep frezzer of capacity upto 300 Ltrs of any make complete all as directed by EIC.\nNote: Spares to be used in repair,gas charging and transportation to workshop and back to site shall be deemed to be considered in quoted rates. | | 2 | Each Job |
|---|
| 99 | 86 | Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for deep freezer of capacity 300 Ltrs with new uncut sealed compressor supplied by manufacture complete. \nMakes :-Tecumesh/Kirlosker copeland | | 2 | Each |
|---|
| 100 | 86.01 | Note Old sealed compressor received from the deep freezer will be property of contractor (ii) The rate quoted by the contractor includes all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition ( iii ) The new sealed unit will be purchased from authorized dealer and existing make & model. | | | |
|---|
| 101 | 87 | Supply and fixing earth industrial plug top for socket for industrial socket metal clad suitable for 20 Amps metal clad MCB DB Make:C&S, Havells,HPL as per sample | | 30 | Each |
|---|
| 102 | 88 | Supply and fixing earth industrial socket metal clad suitable for 20 Amps 240 volts metal clad MCB DB Make:C&S, Havells,HPL as per sample | | 30 | Each |
|---|
| 103 | 89 | Supply and fixing of stand for AC/desert cooler inculding anchor hold fastener/nut and bolts complete all as specified and directed. | | 30 | Each |
|---|
| 104 | 90 | S/F in repair in MCB SP up to 40 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings Make Legrand/C&S/Seimens or its equivalent:-As directed | | 40 | Each |
|---|
| 105 | 91 | M & L for point wiring with copper conductor cable multistrand, PVC sheathed 4 Sqmm size for one power point or AC point controlled by one switch including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of approved size and quality ISI marked, including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading \"Point wiring'\".fixed on walls/ceiling including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed. | | 19 | Point |
|---|