Resource Management For Bore Well No 01 And 02 And Ac Plant At Makarpura Af Station Baroda , Resource Management For Bore Wells 2 Nos At Makarpura Area By Deployment Of One Fgm In One Shift ( One Shift Of Eight Hours ) Including Sundays And Holidays For Operation And Maintanance Of Valves Of Bore Wells Of Make As Existing And Cleaning Of Installation Sorrounding Area All As Specified By Engineer In Charge . ( Ist Shift -06 Hours To 1400 Hours ) . , Resource Management For Maintenance Of Package Type Ac Plant 3 X 11 Ton Capacity By Deploying One ( 01 ) Ac Plant Operator In Each Shift Round The Clock ( Three Shifts Of Eight Hours Each ) Including Sundays & Gazetted Holidays Including Rectification Of Gas Leakage , Checking & Attending Normal Repair For Proper Functioning Of Ac Plant Complete All As Specified And As Directed By The Engineer-In-Charge . ( Ist Shift -06 Hours To 1400 Hours . Iind Shift 1400 Hours To 2200 Hours & Iiird Shift 2200 Hours To 0600 Hours ) . The Plant Mainly Comprising Of The Following :- , Compressor Thermotric Sealed 11 Tr Of Kirloskar Make Or Existing Make - 03 Nos . , Condenser With 2 Hp Elect Motor Of Hindustan Make Or Existing Make - 03 Nos , Note For Item No 1 & 2 , Staff ( All Trade ) Will Always Remain On Duty Duly Wearing Uniform And Shall Maintain The Connected Documents Such As Log Book , Attendence Register ( Centralized Attendance Register Duly Signed By Engineer-In-Charge/ Je/Contractor ) , Installation Running Record Book In A Printed Form , Water Sample Maintained Book Etc And Checking Daily By Engr-In-Charge . , Contractor Shall Provide The T & P ( Spanner Set ) To Tradesman And Also Provide The Log Sheet , Plant Running Book , Clothing Etc And All Records Shall Be Maintained Properly . , Bore Well Installation And Surrounding Complex Should Be Kept Clean And Tidy In Presentable Look , Cutting The Grasses In And Around The Installation As Directed By The Engineer-In-Charge , Otherwise A Recovery At The Double The Market Rate Shall Be Charged If The Installation And Its Complex Are Not Kept Clean All The Times . , Negligence Of Duty During Manning And Operations , Maintaining Of Records Shall Be Taken Seriously And Compensation Shall Be Made As Per Contract Procedures . , Contractor Shall Ensure That No Worker Shall Be Deployed Continuously More Than 48 Hrs In A Week . , The Shift Staff May Be Detailed For Any Other Works As Required By Age E/M And Je E/M . , Fgm/Ac Operator Shall Be Iti Pass Or Minimum Matriculate With Three Years Experience In The Trade From Recognized Government Institution . Necessary Qualification Details Shall Be Submitted By The Contractor Within One Month From The Date Of Acceptance . , Contractor Shall Provide Life Insurance Of Min Rs 1 Lakh To All The Employed Manpower & Copy Of Life Insurance Shall Be Deposited With Department Within One Month Of Acceptance . , No One Be Absent On Duty , If Anyone Found Absent A Recovery At The Double The Quoted Rate Shall Be Levied . , Staff Shall Remain On Duty And Will Not Leave Installation Without Staff . Staff Shall Leave The Duty With Releiver And Proper Handing/Taking Over Is Signed . , Tradesmen Shall Take Preventive Measure And Shall Use Protective Clothing As Per Code Of Practice Of Ie Rules And Deptt Will Not Be Responsible For Any Type Of Untowards Incidents . , Each Shift Of One Trade Man Is For 8 Hours . , Log Sheet/Log Book Of Plant Running And Running Of Ac Plant , Handing/Taking Over Register Atttendence Register , Will Be Maintained In Proper Form And Duly Binded Will Be Issued In Printed Form By The Contractor . All The Documents Shall Be Kept In The Sub Station And Produced To Ge/Vigilance Officer/Higher Authorities During Visit To Installation . , Tradesman Shall Carryout Normal Maintenance Of Plant Such As Cleaning Of Plant/Pipes/Ducts , Parts Etc . , All The Above Documents Shall Be Produced To The Dept ( Sub Div/Ge Office ) At The Time Of Claiming Payments Of Rars Which Is Of Mandatory Requirement . , All The Trades Man Payment Details I . E . , Proof Of Payment In The Bank , Proof Of Epf , Esi And Bonus Payments And Attendence Register And Log Book , Insurance Certificate Duly Signed By All Concerned Shall Be Submitted Along With Rar/Mb And No Payments Shall Be Entertained By The Department In The Absence Of The Above Said Documents . . , M&L For Cleaning Cip Of Ro Plant Using Authorised Chemical With Cleaning Of Membrane Complete All As Specified And Directed By Engineer In Charge . Note: Date Of Cleaning And Due Date Of Cleaning /Cip Register To Be Maintained By The Contractor Duly Signed By Contractor , Je E/M And Engineer In Charge . Cleaning Should Be Carried Out By Authorised Technician And Id Proof Shall Be Submitted To Age E/M Before Carrying Out The Job Complete All As Specified And Directed . , Supply And Mix Aquafit Solution In Water For Chlorination With Maximum Level Of Chlorine Not More Than 2 Ppm At Starting/End For Day To Day Operation And Maintenance Of Pump House Complete All As Specified And Directed . Note : Aquafit Solution Shall Be Brought Out In Company Sealed Packing Of 45Kg Per Container/Drum . , M&L For Dismantling The Complete Inner And Outer Unit Of Package Type Ac Plant 3 X 11 Tr By Means Of Disconnection Of Pipe Connection And Washing Of Complete Out Door Unit By Means Of Caustic Soda , Hcl Acid And Crc Solution And Over Oiling Inner Unit By Means Of Good Quality Of Oil And Grease And Checking Of All Nuts , Bolts And Fan Bolts And Replace The Fan Belt And Refixing The Same Duly Repaired And Testing Complete . Including Cleaning Of Cooling Coil Of 3 X 11 Tr Ac Plant And Filter With Mac Solution Including Rubbing With Brush Complete All As Specified And Directed . , Supply & Fix In Replacement Of Fan Belt Type A-32 Of Approved Make Complete All As Per Site Requirement . , Taking Down Burnt Compressor Of Package Type Ac Of Make Kirloskar/Takumseh/Usha Or Existing Make And Reconditioning Compressor At 11 Tr Plant ( Consting Two Nos Of 5 . 5 Tr ) Complete Incl Cutting , Brazing , Flaring The Suction And Discharge Line , Refixing , Testing And Commissioning Complete All As Specified And DirectedNote : Gas Charging Shall Be Measured And Paid Separately Under Respective Item Of Boq . , M & L For Charging Of Gas Refrigerant In Package Type Ac 5 . 5 Ton Capacity Of Any Make Including Flushing Down Refrigerant System With Nitrogen Gas Complete All As Specified And Directed . Note : Leakage Free Test Certificate To Be Submitted By The Contractor On Every Charging . , Dismantling The Worn Out Copper Connecting Pipe And M & L For Providing New Copper Connecting Pipe Of Size 25 Mm Dia Including Insulation Material Complete All As Specified And Directed . , Dismantling The Worn Out Copper Connecting Pipe And M & L For Providing New Copper Connecting Pipe Of Size 15 Mm Dia Including Insulation Material Complete All As Specified And Directed . , Dismantling Unserviceable Contactor And M & L For Providing New Contactor Of No/Nc Type Of Existing Make Complete All As Specified And Directed . , Dismantlng Unserviceable Relay Of Package Type Ac Plant And M & L For Provision Of New Relay With Socket Complete Of Existing Make Complete All As Specified And Directed . , Supply And Fix In Repairs Pcb Unit Of Existing Make Complete All As Specified And Directed . , Supply And Fix In Repairs Dryer Unit All As Per Specification And Direction Of Engineer In Charge . Make:Denfross/Existing Make Or Equvalent Make Approved By Accepting Officer . , Supply And Fix In Repairs Amper Meter With Selector Switch , 0-200 A , 415 V , 50 Hz , All As Per Specification And Direction Of Engineer In Charge . Make:Conzerve/Existing Or Equvalent Make Approved By Accepting Officer , Supply And Fix In Repairs Volt Meter With Selector Switch , 0-500 V , 415 V , 50 Hz , All As Per Specification And Direction Of Engineer I