Repairs Renewal And Maintenance To Street Lights Solar Security Lights And Soalr Water Heaters And Dg Sets Amf Pantels And Allied Work At Caw And Af Offrs Residential Accn Under Ge Af Hakimpet, CAW-Telangana

Military Engineer Services-MES has published Repairs Renewal And Maintenance To Street Lights Solar Security Lights And Soalr Water Heaters And Dg Sets Amf Pantels And Allied Work At Caw And Af Offrs Residential Accn Under Ge Af Hakimpet. Submission Date for this Tender is 24-04-2021. Diesel Generators Tenders in CAW Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

27526485
Corrigendum : Repairs Renewal And Maintenance To Street Lights Solar Security Lights And Soalr Water Heaters And Dg Sets Amf Pantels And Allied Work At Caw And Af Offrs Residential Accn Under Ge Af Hakimpet
Open Tender
Indian
Telangana
CAW
24-04-2021

Tender Details

Repairs Renewal And Maintenance To Street Lights Solar Security Lights And Soalr Water Heaters And Dg Sets Amf Pantels And Allied Work At Caw And Af Offrs Residential Accn Under Ge Af Hakimpet

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Apr-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-04-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 19400.0 /-
Tender Value
Refer document

BOQ Items

NNAME OF WORK: REPAIRS, RENEWAL AND MAINTENANCE TO STREET LIGHTS, SOLAR SECURITY LIGHTS AND SOALR WATER HEATERS AND DG SETS, AMF PANTELS AND ALLIED WORK AT CAW AND AF OFFRS RESIDENTIAL ACCN UNDER GE(AF) HAKIMPET
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for servicing of DG set of capacity 15 KVA to 75 KVA installed at AFS Begumpet/CAW / AF Offrs residential accn by carrying out the following maintenance including testing on completion for satisfactory performance for a period of 02 hrs at connected load complete all as specified and as directed :- 3 Each Job
2 1.01 Note:-Rate quoted for above item shall include for the following :-\n
3 1.02 Drain out of diesel from tank and storing in cleaned containers, cleaning the tank thoroughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered.
4 1.03 Drain out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil upto required level (Engine oil will be supplied free for filling under schedule 'B' items)
5 1.04 Replacing suitable fuel filter stainer, fuel pipe, fuel filters, engine oil filter, air cleaner element and oil seal assembly complete. (Note: Material will be measured and paid seperately as 'Supply only')
6 1.05 Check coolant level & top up the same if required (Note: Coolant will be measured and paid separately as 'Supply Only')
7 1.06 Check and top up the electrolyte/distilled water in starting batteries to maintain the required specific gravity. Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors.
8 1.07 Checking and general adjustments of FIP, fuel injectors, governer, turbo charger etc for proper functioning of DG Set.
9 1.08 Replacing suitable size of 'V' belts, hoses and clamps of air cleaner. (Note: Material will be measured and paid seperately as 'Supply only')
10 1.09 Tightening all the fasteners of complete DG set to the required torque and cleaning the complete DG Set with suitable cleaning agent.
11 2 All as per item No. 1 here-in-before but for above 75 KVA and upto 160 KVA DG Set.\nMake -greaves/ Kirloskar all as specified and as directed. 1 Each Job
12 3 Supply only the following items suitable for DG set of capacity upto 75 KVA capacity, Make: Kirloskar :-
13 3.01 Fuel filters set (primary and micro filter) 10 Each
14 3.02 Fuel pipes set (Fuel pump to filter and filter to feed pump) 8 Each
15 3.03 Lub. oil filter 8 Each
16 3.04 Air cleaner element 2 Each
17 3.05 V- Belts 5 Each
18 3.06 Oil seal housing 10 Each
19 4 Supply only the following items suitable for DG set of capacity above 75 KVA and upto 160KVA, capacity Make: Kirloskar :-
20 4.01 Fuel filters set (primary and micro filter) 2 Each
21 4.02 Fuel pipes set (Fuel pumpt to filter and filter to feed pump) 2 Each
22 4.03 Lub. oil filter 2 Each
23 4.04 Air cleaner element 2 Each
24 4.05 V- Belts 2 Each
25 4.06 Oil seal housing 2 Each
26 5 Supply only of coolant suitable for DG sets complete all as specified and as directed. Make: K-oil / Cummins Castrol /Servo. 35 Ltr
27 6 Descalling of radiator assembly by removing from engine, transporting to the workshop and removing the sediments, scales and rust etc. by submerging in acid for atleast 08 hrs, cleaning with suitable brush, high pressure water washing and air cleaning, arresting the leakages by gas welding / soldering with suitable material, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with new hoses, clips etc complete all as specified and directed by Engineer-in-Charge for DG Set of capacity upto 75 KVA installed at AFS Begumpet complete all as specified and as directed. 2 Each Job
28 7 All as per item No.6 here-in-before but for DG Set above 75 KVA to 160 KVA complete all as specified and as directed. 1 Job
29 8 Dismantling the defective water pump from the DG Set of capacity upto 40 KVA, opening the pump, replacing the pump repair kit complete as per manufacturer's recommendations, re-assembling and re-fixing the same and testing on completion complete all as specified and as directed. 2 Job
30 9 All as per item No. 8 here-in-before but of capacity above 40 KVA and upto 75 KVA complete all as specified and as directed. 1 Job
31 10 All as per item No. 8 here-in-before but of capacity above 75 KVA and upto 160 KVA complete all as specified and as directed. 1 Job
32 11 Dismantling the defective self starter assembly carefully from the DG set of capacity upto 40 KVA and carryout repair and servicing by cleaning all accessories with suitable cleaning agent and supply and replace commutator, carbon brush set, carbon brush holder, king pin holder, armature check nut, clutch plate assy and solenoid etc. re-assembling and re-fixing the same and testing complete all as specified and as directed. 2 Job
33 12 All as per item No. 11 here-in-before but for DG set of capacity above 40 KVA and upto 75 KVA complete all as specified and as directed. 1 Job
34 13 All as per item No. 11 here-in-before but for DG set of capacity above 75 KVA and upto 160 KVA complete all as specified and as directed. 1 Job
35 14 Dismantling the defective solenoid switch carefully from the DG set of capacity upto 160 KVA and supply and fix new solenoid switch suitable for engine stop all as existing capacity and make and testing complete all as specified and as directed. 2 Job
36 15 Dismantling the defective battery charging alternator carefully from the DG set of capacity upto 40 KVA and carryout repair and servicing by cleaning all accessories with suitable cleaning agent and supply and replace carbon brush, brush holders, bushes, bearings, varnishing etc, re-assembling and re-fixing the same and testing complete all as specified and as directed. 2 Job
37 16 All as per item No. 15 here-in-before but for DG set of capacity above 40 KVA and upto 75 KVA complete all as specified and as directed. 1 Job
38 17 All as per item No. 15 here-in-before but for DG set of capacity above 75 KVA and upto 160 KVA complete all as specified and as directed. 1 Job
39 18 Supply and fix in repair alternator terminal block suitable for DG Set alternator upto 160 KVA capacity 2 Each
40 19 Taking down of existing gauges and Supply and fix following gauges suitable for DG sets complete all as specified and as directed.
41 19.01 Digital RPM Meter 2 Each
42 19.02 Analogue RPM Meter 2 Each
43 19.03 Oil Pressure Gauge 3 Each
44 19.04 Oil Temperature Gauge 3 Each
45 19.05 Water Temperature Gauge 4 Each
46 19.06 Fuel Indicator Gauge suitable for fuel tanks of silent DG sets. 4 Each
47 20 S& F in repair copper terminal heavy duty for battery (length 1.5 mtr) connection with suitable size of copper lugs on one side, brass lead on other end all as directed 6 Each
48 21 Supply and wrap asbestos rope of 10mm thick over silencer of DG sets including taking down of existing u/s rope complete all as specified and as directed. 3 RM
49 22 Servicing of AMF Panel of DG sets of capacity from 15 KVA to 160 KVA by cleaning the complete panel with suitable cleaning agent and checking the controlled relays, time delay relay, contactors for proper functioning, replacing defective spare parts, replacement of defective wires of existing size, tightening of all connections and applying jelly on contactors including taking down existing unsv components complete all as specified and as directed. 2 Each Job
50 23 Taking down U/S Genset controller, power contactor, Time relay, Battery charging unit, Voltage regulator, Logic relay and fixing only new items and making connections all as existing and as directed by Engr-in-Charge. 6 Each
51 23.01 Note 21 & 22:- Spares required will be measured and paid separately as 'Supply Only' in relevant items.
52 24 Supply only the following items suitable for existing DG set AMF Panels:-
53 24.01 Main Power Contactor 4P rating upto 70 Amps suitable for 15 KVA to 40 KVA DG Set. 2 Each
54 24.02 Main Power Contactor 4P rating upto 140 Amps suitable for 40 KVA to 100 KVA DG Set. 1 Each
55 24.03 AMF Logic controller relay suitable for 15 KVA to 40 KVA DG Set. 2 Each
56 24.04 AMF Logic controller relay suitable for 40 KVA to 100 KVA DG Set. 1 Each
57 24.05 AMF Logic controller relay suitable for 100 KVA to 160 KVA DG Set. 1 Each
58 24.06 Line Voltage Monitor 415V suitable for 15 KVA to 75 KVA DG Set. 3 Each
59 24.07 Line Voltage Monitor 415V suitable for 100 KVA to 160 KVA DG Set. 1 Each
60 24.08 Timer suitable for 15 KVA to 160 KVA DG set for ON/OFF delay. 4 Each
61 24.09 Relay module 12V DC suitable for 15 KVA to 160 KVA DG set. 3 Each
62 24.1 Battery charging electronic PCB for 15 KVA to 75 KVA DG Set. 2 Each
63 24.11 Battery charging electronic PCB for 100KVA to 160 KVA DG Set. 1 Each
64 24.12 Battery charger complete unit for 15 KVA to 75 KVA DG Set. 2 Each
65 24.13 Battery charger complete unit for 75VA to 100 KVA DG Set. 1 Each
66 24.14 Auto/Manual switch complete assembly. 4 Each
67 24.15 Indicator lamp as existing on panel board (set of 3) all as specified and as directed. 5 set
68 24.16 Engine start/stop push button. 4 Each
69 24.17 Analogue Voltmeter suitable for 3 Phase supply of existing description. 3 Each
70 24.18 Analogue Ammeter of suitable capacity of existing description. 3 Each
71 24.19 VAF meter of suitable capacity as per existing description. 3 Each
72 25 Taking down unsv AVR unit and supplay and fix new AVR unit suitable for DG set upto 75 KVA. 2 Each Job
73 26 Taking down unsv AVR unit and supplay and fix new AVR unit suitable for DG set above 75 KVA and unto 100 KVA. 1 Each Job
74 27 Servicing of APFC panel of capacity from 30 KVAR to 150 KVAR installed at AFS Begumpet, ORC & CAW by cleaning the complete panel with suitable cleaning agent and checking all the components for proper functioning and replacing the defective components and providing suitable wires, lugs, nuts, bolts and washers required for connecting including taking down such as capacitor banks of suitable capacity, power contactors, contractor relays, power factor relay, switches and push buttons etc from the panel by disconnecting electric supply and testing complete all as specified and as directed. 2 Each Job
75 27.01 Note: Components / spares will be measured and paid separately as 'Supply Only', in relevant items. However the cost of suitable wires, lugs, nuts, bolts and washers required for connecting spare parts shall be included in quoted rate.
76 28 Supply only the following items suitable for DG set AMF panels:-
77 28.01 Cylindrical type, 440V, MPP Capacitor, self healing capability, heavy duty to withstand high inrush currents, of capacity 5 KVAR. 2 Each
78 28.02 Cylindrical type, 440V, MPP Capacitor, self healing capability, heavy duty to withstand high inrush currents, of capacity 10 KVAR. 2 Each
79 28.03 Cylindrical type, 440V, MPP Capacitor, self healing capability, heavy duty to withstand high inrush currents, of capacity 15 KVAR. 2 Each
80 28.04 3 phase, capacitor duty contactor, 415 volts, suitable upto 10 KVAR capacitors. 1 Each
81 28.05 3 phase, capacitor duty contactor, 415 volts, suitable above 10 and upto 20 KVAR capacitors. 2 Each
82 28.06 3 phase, capacitor duty contactor, 415 volts, suitable above 20 and upto 30 KVAR capacitors. 2 Each
83 28.07 Auto/Manual switch assembly of existing model. 2 Each
84 28.08 ON/OFF push button of existing model. 2 Each
85 29 M&L for 8 stage APFC relay all as exixting description comlete all as specified and directed. 2 Each
86 30 M& L for CT coils of range upto 400A/5A complete all as specified and as directed. 2 Each
87 31 Repairs the defective street light fitting on its own position of any description on poles at elevated height by disconnecting the electric supply and removing carbon in cables, holders, rectify loose connections if any, reconnecting all as specified and as directed. 50 Each Job
88 32 Taking down, defective street light fitting of any description from pole elevated height by disconnecting the electric supply and replacing the defective components such as LED Driver, lamp, ballast, holder, acrylic cover and burnt out wiring of suitable size and capacity, re-assembling and re-fixing in its original position and testing for proper functioning complete all as directed. 50 Each Job
89 32.01 Note: street/ security light fitting components such as ballast, lamp, holder, Ignitor, capacitor, acrylic cover and cables etc., as required will be measured and paid separately under relevant items of Sch 'A' as "Supply only" in relevant items.
90 33 Supply only the following items suitable for existing street light fittings :-
91 33.01 V.P.I.T copper ballast suitable for CFL 2x11 watts fittings. 5 Each
92 33.02 Electronic ballast suitable for CFL lamp 1 x 36 watts fittings. 5 Each
93 33.03 Electronic ballast suitable for CFL lamp 2 x 36 watts fittings. 5 Each
94 33.04 Electronic ballast suitable for T-5 lamp 2 x 24 watts fittings. 5 Each
95 33.05 Electronic ballast suitable for T-5 lamp 1 x 28 watts fittings. 5 Each
96 33.06 CFL 11 watt lamp Pin type as existing model. 5 Each
97 33.07 LED driver suitable for upto 30W LED street light fitting. 20 Each
98 33.08 LED driver suitable for above 30W & upto 60W LED street light fitting. 12 Each
99 33.09 LED driver suitable for above 60W & upto 120W LED street light fitting. 10 Each
100 34 S&F in repair LED street light fitting 30W LED made up of pressure die cast aluminium housing with acrylic cover as diffuser with minimum IP 66 protection complete including taking down old unserviceable fitting all as specified and as directed. Make: Bajaj, Havells, CG, Phillips 15 Each
101 35 S&F in repair LED street light fitting 45W/48W LED made up of pressure die cast aluminium housing with acrylic cover as diffuser with minimum IP 66 protection complete including taking down old unserviceable fitting all as specified and as directed. Make: Bajaj, Havells, CG, Phillips 15 Each
102 36 S&F in repair LED street light fitting 70W/72W LED made up of pressure die cast aluminium housing with acrylic cover as diffuser with minimum IP 66 protection complete including taking down old unserviceable fitting all as specified and as directed. Make: Bajaj, Havells, CG, Phillips 10 Each
103 37 Lowering the high mast light fitting manually by disconnecting the electric supply and replacing the defective components including taking down existing components such as lamp, holder and burnt out wiring, re-assembling and re-fixing in its original position, aligning high mast carraige and testing for proper functioning complete all asspecified and as directed. Note: The components such as lamp, holder and cable etc as required will be measured and paid separately under relevant items of Sch 'A' as "Supply only" in relevant items. 3 Each
104 38 Taking down existing unsv twin core aluminium cable and Supply and connect new PVC insulated twin core aluminium conductor cable of 2.5 sqmm complete all as specified and directed by Engineer-in-Charge. 50 RM
105 39 Taking down existing unsv submain wiring in steel/ PVC conduit and M&L for submain wiring with 2x1.5sqmm +1x1.5sqmm FRLS copper conductor cable drawn through stove enamelled steel conduit of size 20 mm dia, fixed to street light pole with suitable size FI clamps made of 20x3mm FI, from street light fittings to loop in loop out box complete all as specified and as directed. 50 RM
106 40 Taking down unsv street light loop-in and loop out box by disconnecting electrical connection and removing existing clamps, nuts, bolts, and washers and Supply & Fix Factory made out door type street lihgt loop-in and loop out box made out of 2mm thick MS sheet, of size 220mm x 180mm x 150mm with pre-treated & powder coated comprising insulators, connectors etc. and with one SP MCB 6A ''C'' Series, one PVC way connector etc including suitable size clamps, nut bolts & washers complete including suitable clamps for fixing all as specified and directed. 20 Each
107 41 Taking down unsv timer switch from the existing street light panel board by disconnecting electrical connection and supply and fix new timer Programmable timer Switch 24 Hrs including all electrical connections complete all as specified and as directed. Make : Crab Tree/ CG/L&T/GEC. 2 Each
108 42 Taking down unsv MCB from the existing street light panel or terminal box by disconnecting electrical connection and Supply and fix new MCB SP 6 Amps capacity ''C'' series complete all as specified and as directed. 50 Each
109 43 S&F in repair Power contactor TP 32 Amps in existing street light control panel all as specified and as directed. Make : Havells/L&T/HPL/ABB/ 3 Each
110 44 Taking down the damaged / punctured cable form the excavated trench for cutting and removing the damaged portion of the cable jointing the serviceable part of the cable (Note: Excavation jointing and relaing shall be measured separately under relevant items)
111 44.01 6 Sqmm 2 core 100 RM
112 44.02 10 Sqmm 4 core 100 RM
113 44.03 16 Sqmm 4 core 80 RM
114 44.04 25 Sqmm 3.5 core 80 RM
115 44.05 50 Sqmm 3.5 core 80 RM
116 45 Relaying the repaired and serviceable part of the cable in the same trench or new trench as per site conditions.
117 45.01 6 Sqmm 2 core 30 RM
118 45.02 10 Sqmm 4 core 30 RM
119 45.03 16 Sqmm 4 core 30 RM
120 45.04 25 Sqmm 3.5 core 30 RM
121 45.05 50 Sqmm 3.5 core 30 RM
122 46 Supply and lay, LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of following sizes including taking down old cables complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
123 46.01 6 Sqmm 2 core 70 RM
124 46.02 10 Sqmm 4 core 70 RM
125 46.03 16 Sqmm 4 core 50 RM
126 46.04 25 Sqmm 3.5 core 50 RM
127 46.05 50 Sqmm 3.5 core 50 RM
128 47 Taking down unsv Aviation obstruction light from the elevated height of over head tank at a height of appx. 20 M, supply and fix new Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, LED driver and other accessories as required complete. Make: Bajaj, Model: BGAV 302 LED or its equivalent in Phillips/ Crompton greaves. 1 Each
129 48 Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth in hard / dense soil for laying of LT cable complete all as specified and as directed. 68 Cum
130 49 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and as directed. 56 Cum
131 50 Removing, surplus excavated material to a distance n.exc. 50 M and depositing where directed at a level n.exc. 1.5 M above the starting point complete all as specified and as directed. 11 Cum
132 51 Supply and spread fine river sand in trenches or in cushioning to cable in substation yard surrounding transformer all as specified and as directed. NOTE: For measurement purpose, punned down thickness shall only be taken. 26 Cum
133 52 Supply & laying well burnt bricks, sub class 'B' brick of size 230x115x75mm laid across trenches for cable protection all as specified and as directed. 2174 Each
134 53 Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables all as specified and as directed of size 40 mm dia bore. 10 RM
135 54 M & L for Road cutting/ hard standing for taking up or laying of LT UG cable upto a depth of 15 cm, after laying of cable, well ramming to the excavated soil and repair the exvcavated portion of road as existing or by providing suitable mixture of PCC all as specified and as directed. 5 Sqm
136 55 Servicing and mantanance of solar water heater, cleaning the solar panel by using CTC & soft cloth and adjusting to the proper direction, and replacing the defective parts/ components and testing including taking down unsv components, if required to replace complete all as specified and directed. Note: The parts/ components required will be measured and paid separately under relevant items of Sch 'A' as 'Supply only' in relevant items. 15 Each job
137 56 Supply only the following items suitable for existing Solar water heater :-
138 56.01 Heating element of capacity 2 KW of solar water heater. 8 Each
139 56.02 Heating element of capacity 3 to 4 KW for solar water heater. 8 Each
140 56.03 Solar tubes all as existing evacuated tube collector type solar heaters 8 Each
141 57 Supply, Errecting and fixing in repairs steel tubular swaged poles complete with cast iron base plate final taper plug, bolts and nuts & screws as specified 410 SP-31 (9.0 Mtr Long) and providing 3 Nos of 30 cm wide circular bands with black yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over a black painted back ground at a height of 2 m from bottom of pole with 5 cm large bold letters 2" wide complete all as specified and directed. 1 Each
142 58 S&F in repair New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire 25W complete all as specified and as directed. Make: Havells, Model No:CORALPT25WLED757PSYMTOPC or equivalent in CG, Phillips 1 Each
143 59 M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation for rection of poles / stay assembly complete including breaking and removing the old concrete all as specified and as directed. 2 Cum
144 60 M&L for PCC 1:3:6 type C-2 using 20mm graded stone aggregate as in coping to pole etc including breaking and removing the old concrete necessary form work complete all as specified and as directed. 1 Cum
145 61 M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,and applying two coats of syntetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed. 30 Sqm
146 62 S&F in repair street light bracket made up of GI pipe light grade 32 mm dia length 1.5 RM bent to shape with MS clamps, bolts, nut & washers complete, including taking old bracket of any size all as specified and as directed 10 Each
147 63 S&F in repair LED flood light fitting 120W LED made up of die cast aluminium housing with acrylic cover as diffuser with minimum IP 66 protection complete with bolts, nuts etc for fixing all as specified and as directed. Make: Syska, Bajaj, Wipro, Havells, CG, Phillips 2 Each
148 64 S&F in repair LED flood light fitting 150W LED made up of die cast aluminium housing with acrylic cover as diffuser with minimum IP 66 protection complete with bolts, nuts etc for fixing all as specified and as directed. Make: Syska, Bajaj, Wipro, Havells, CG, Phillips 2 Each
149 65 Servicing of defective solar street system comlete and rectifying minor faults including copper connecting wire, battery checking, solar panel adjusting etc, complete all as directed. 10 Each Job
150 66 M&L for writing MES Nos of height minimum 4cm over DG sets, Transformers, Stabilizers etc by using enamel paint of suitable colour complete all as specified and directed.\nNote:- One MES No comprises 10 to 14 alpha numerical characters & each MES No wil be measured sa one job. 10 Each Job
151 67 S&F in repair landscape LED luminaire 8W aluminium body of minimum height 0.5 M suitable for garden alongwith necessary concrete bedding, nuts, bolts, connecter, connecting copper wire etc, complete all as directed. 10 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail