| 1 | 1 | M&L for overhauling/Servicing of Air Conditioning split/window type of any capacity installed at various location at ground floor/1st floor by means of removing dust by blower, washing and cleaning of condensing and cooling coil with suitable chemical, checking connection of all components including oiling and greasing all as specified and directed. | | 100 | Each |
|---|
| 2 | 2 | S&F in replacement of old unserviceable sealed unit (compressor) including charging of gas complete after taking down defective compressor from enclosure and making connection/jointing suction/discharge pipe for split AC 1.5 Ton capacity \n | | 10 | Each |
|---|
| 3 | 3 | All as per serial item No 2.00 above but for window type AC 1.5 Ton capacity. | | 10 | Each |
|---|
| 4 | 4 | S&F in repair of defective and broken copper suction pipe of 20 mm dia including cutting of damage/worn out with the copper pipe soldering & brazing, flaring with insulation including all other accessories required at site directed by Eng-in-Charge. | | 30 | RM |
|---|
| 5 | 5 | S&F in repair of defective and broken copper discharge line 15 mm dia incl. cutting of damage/worn out copper pipe with the help of soldering & brazing with complete fitting and accessories required at site as directed by Eng-in-Charge. | | 30 | RM |
|---|
| 6 | 6 | M&L for insulation of copper tubing of any size of dia for split type AC of capacity 1.5/3 ton compete all as specified and as directed. | | 30 | RM |
|---|
| 7 | 7 | S&F in repair metal clad plug & socket enclosure, socket with two pin and earth and one plug top with one MCB SPN 20 Amps, 240 Volt complete all as specified and directed. | | 10 | Each |
|---|
| 8 | 8 | S&F in repair metal clad socket ,two pin and earth , 20 Amps, 250 Volts suitable for metal clad sheet enclosures complete all as specified and directed.\n | | 10 | Each |
|---|
| 9 | 9 | S&F in repair metal plug top, two pin and earth , 20 Amps, 250 Volts suitable for metal clad sheet enclosures complete all as specified and directed. | | 10 | Each |
|---|
| 10 | 10 | S&F relay coil suitable for split AC 1.5/3 Ton complete all as specified and as directed. | | 10 | Each |
|---|
| 11 | 11 | S&F running capacitor 45/50 mfd 440/220V complete all as specified and as directed. | | 50 | Each |
|---|
| 12 | 12 | S&F running capacitor 80/120 mfd 440/220V complete all as specified and as directed. | | 10 | Each |
|---|
| 13 | 13 | S&F running capacitor 4 mfd 440/220V complete all as specified and as directed. | | 30 | RM |
|---|
| 14 | 14 | S&F flexible copper conductor cable of size 3 core (4/0.0076) 1100 Volts grade complete all as specified and as directed. | | 180 | RM |
|---|
| 15 | 15 | S&F in repair compressor connection lead of copper conductor of suitable size comprising of copper thimbles and connectors complete all as specified and as directed. | | 10 | Each |
|---|
| 16 | 16 | S&F air filter suitable for AC 2.0 ton capacity for any make as directed. | | 1 | Each |
|---|
| 17 | 17 | M&L for rewinding of blower/condenser fan motor of split AC 1.5 ton of any make & size with super enamelled copper winding wire including varnishing , Bracing and replacement of ball bearing/ bush of required size all as directed. | | 10 | Each Job |
|---|
| 18 | 18 | M&L fan blade assembly suitable for split 1.5 Ton capacity. | | 10 | Each |
|---|
| 19 | 19 | S&F remote control suitable for split AC 1.5 Ton hanging type remote 230 Volts.\n | | 10 | Each |
|---|
| 20 | 20 | S&F air filter suitable for split AC 1.5 ton capacity for any make and size as directed. | | 10 | Each |
|---|
| 21 | 21 | S&F in repair of condensor/blower motor of split AC 1.5 Ton capacity complete all as directed. | | 10 | Each |
|---|
| 22 | 22 | S&F in repair of condensor/blower motor of Window AC 1.5 Ton capacity complete all as directed. | | 10 | Each |
|---|
| 23 | 23 | S&F in repair of wiring kit suitable for window/split type AC 1.5 ton capacity including soldering tapping and thimbling etc complete all as specified and as directed. | | 10 | Each |
|---|
| 24 | 24 | S&F in repair of PCB unit suitable for split type AC upto 3 ton capacity including soldering tapping and thimbling etc complete all as specified and as directed. | | 10 | Each |
|---|
| 25 | 25 | M&L for repair of PCB unit suitable for window type AC 1.5 Ton capacity including soldering tapping and thimbling etc complete all as specified and as directed. | | 5 | Each |
|---|
| 26 | 26 | S&F in repair thermostate switch with Knob 230 Volts suitable for window AC 1.5 ton complete all as specified and as directed. | | 10 | Each |
|---|
| 27 | 27 | S&F in repair selector switch with Knob as per matching to existing suitable for window AC 1.5 ton complete all as specified and as directed. | | 10 | Each |
|---|
| 28 | 28 | S&F in repair PVC grill any type/any size suitable for window type AC 1.5 TR capacity complete all as specified and as directed.. | | 10 | Each |
|---|
| 29 | 29 | Disconnecting, dismantling and taking out existing defective/unserviceable condenser coil of any description and in any position and supply & fixing new condenser coil, suitable for window type AC 1.5 TR as per sample complete all as specified and as directed. | | 5 | Each |
|---|
| 30 | 30 | All as per serial item No 29.00 above but cooling coil. | | 5 | Each |
|---|
| 31 | 31 | M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and as directed.. | | 4 | Each Job |
|---|
| 32 | 32 | M&L for charging of refrigerant gas R-22/R-410/R-600/R-407 in window type AC/split type AC any capacity, compressors of air conditioning plant including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitrogen pressure to ensure leak proof gas circulated in system, flushing out the nitrogen gas complete all as specified and as directed. | | 90 | Kg |
|---|
| 33 | 33 | M&L for rewinding of exhaust fan motor for desert cooler with existing size/gauge wiring super enamelled copper winding wire ,insulating material, replacement of bushes,varnising,drying etc complete including taking out & refixing and testing in position complete all as specified and as directed. | | 10 | Each |
|---|
| 34 | 34 | S&F in repair of automatic boost/buck transformer for low and high voltage correction equipped with electronic transistorized relay suitable for correction on single phase, 50 cycles, AC supply, naturally air closed, indoor type complete with voltmeter and designed for input voltage of 175V to250V and output voltage stabilized between 215V to 240V of capacity 4 KVA complete all as specified and as directed.\n | | 15 | Each |
|---|
| 35 | 35 | S&F in repair of desert cooler body made of 20 gauge CGI sheet suitable for evaporating type desert cooler of size 73x73x93 cm including side panel-03 Nos with 20 gauge CGI sheet and water tank height 20 cm & grill with fins electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow, PVC pipe connection,PVC cable 3 core 23/.0076- 3 mtr with top plug 5 Amps -01 No. duly painted complete body internally and all side panel inner and outer side with two coat with synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed. | | 15 | Each |
|---|
| 36 | 36 | M&L for servicing of desert cooler of any size including cleaning of desert cooler of any size including cleaning of desert cooler from inside & outside greasing of fan kit, motor water pump and connected accessories complete all as specified and as directed. | | 5 | Each |
|---|
| 37 | 37 | M&L for painting of desert cooler body both internally and externally by spray painting with one coat of synthetic enamel paint of approved tint and colour over a coat of red oxide primer where reqiured after cleaning the desert cooler body thoroughly with the help of emery paper and dry jute cloth removing the old peep out colour layer and rust making the surface even and smooth complete all as specified and as directed. | | 10 | Each |
|---|
| 38 | 38 | S&F in repair of wood wool pads of size 450x600 mm set of 3 of best quality including wire netting (chicken wire mesh) as approved by Engineer-in-Charge. | | 24 | Each Set of 3 |
|---|
| 39 | 39 | S&F Capacitor 4.0 mfd suitable for desert cooler/water cooler. | | 10 | Each |
|---|
| 40 | 40 | S&F in replacement of cooler pump submersible type single phase 50 Hz,230 Volts ,1340 RPM,45/50 watt suitable for evaporative type desert cooler including fixing clamp inside the desert cooler complete all as specified and directed. | | 30 | Each |
|---|
| 41 | 41 | S&F in replacement cooler motor 500 mm sweep single phase 230 Volts, 180 Watt,1400 RPM including fan blades fixing clamps and condenser complete all as specified and as directed.\n | | 10 | Each |
|---|
| 42 | 42 | S&F sealed unit (compressor) after taking down defective compressor from the enclosure and making connection for water cooler 40/80 Ltr capacity including charging of gas complete.\n | | 1 | Each |
|---|
| 43 | 43 | S&F sealed unit (compressor) after taking down defective compressor from the enclosure and making connection suitable for Refrigerator 165 Ltr capacity including charging of gas complete.\n | | 2 | Each |
|---|
| 44 | 44 | Supply only AC electric condenser motor as per sample 230 Volts,1250 RPM, single speed complete all as specified and as directed. | | 2 | Each |
|---|
| 45 | 45 | M&L for shifting of existing Air Conditioners window AC of 1.5 ton capacity from one place to another place, any height/ any floor as per requirement of users any make and new re-installation and commissioning the unit including testing after gas charging complete all as specified and as directed. | | 10 | Each |
|---|
| 46 | 46 | M&L for shifting of existing Air Conditioners Split type of 1.5 ton capacity from one place to another place as per requirement of users any make and new re-installation and commissioning the unit by using additional copper tubing of required size bent to shape including brazing insulation etc testing after gas charging complete all as specified and as directed. | | 10 | Each |
|---|
| 47 | 47 | S&F in repair AC stand suitable for out door AC unit upto 3 ton capacity including making hole for stand and making good with PCC 1:2:4 or CM 1:3. | | 10 | Each |
|---|
| 48 | 48 | M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with suitable chemical , servicing of cooling coil, fan, motor,condenser, fan blades and its connected water and refrigerant fitting complete all as specified and as directed. | | 5 | Each Job |
|---|
| 49 | 49 | S&F in repair thermo stat switch suitable for water cooler of any make/ size complete all as specified and as directed. | | 5 | Each |
|---|
| 50 | 50 | S&F in repair starting relay /over load relay suitable for water cooler of any make/ size complete all as specified and as directed. | | 3 | Each |
|---|
| 51 | 51 | S&F in repair push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make/ size complete all as specified and as directed. | | 10 | Each |
|---|
| 52 | 52 | Dismantling & disconnecting connection taking out old unserviceable items and checking the serviceability of different spares/components/parts of security light fittings 9HPSV, HPMV, Metal halide fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installation etc and taking out the old existing LED street light fitting/security light fitting/flood light fitting and electric connections remove by carbon, disconnect cable connection and re-connect, after repair of any description and in any position from poles/walls/pillars etc complete and unserviceable LED street light depositing in MEs store yard and collect any type light and fixing all as directed. \nNote:- Spare part for repair shall be measured and paid separately as supply only under respective item. | | 360 | Each Job |
|---|
| 53 | 53 | Supply only HPSV Tubular Clear Lamp (SON LUX-T),70 SON-T Watts | | 30 | Each |
|---|
| 54 | 54 | Supply only HPSV Tubular Clear Lamp (SON LUX-T),150 SON-T Watts | | 40 | Each |
|---|
| 55 | 55 | Supply only HPSV Tubular Clear Lamp (SON LUX-T),250 SON-T Watts. | | 25 | Each |
|---|
| 56 | 56 | Supply only HPSV Tubular Clear Lamp (SON LUX-T),400 SON-T Watts. | | 6 | Each |
|---|
| 57 | 57 | Supply only Ballast (Choke) , 70 Watts,SON/MH open construction heavy duty VPIT copper wound. | | 30 | Each |
|---|
| 58 | 58 | Supply only Ballast (Choke) for HPSV fittings, 150 Watts,SON/MH open construction heavy duty VPIT copper wound. | | 40 | Each |
|---|
| 59 | 59 | Supply only Choke for HPSV fittings, 250 Watts,SV/MH Sleek open construction heavy duty VPIT copper wound. | | 20 | Each |
|---|
| 60 | 60 | Supply only Choke for HPSV fittings, 400 Watts,SV/MH Sleek open construction heavy duty VPIT copper wound. | | 4 | Each |
|---|
| 61 | 61 | Supply only Electronic igniter suitable for 70/150/250/400W HPSV/Metal Halide fittings. | | 200 | Each |
|---|
| 62 | 62 | Supply only Type of Lamp 70 MH SINGLE ENDED COATED ELLIPTICAL LAMP (MH SEE) 4000K. | | 10 | Each |
|---|
| 63 | 63 | Supply only Type of Lamp 150 MH DE 6000K QUARTZ TUBE LAMP. | | 20 | Each |
|---|
| 64 | 64 | Supply only porcelain holder’s screw or pin type for 70 Watt fittings for any type and any description as directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 65 | 65 | Supply only porcelain holders screw or pin type for 150/250/400 Watt fittings for any type and any description as directed. | | 20 | Each |
|---|
| 66 | 66 | S&F in repair energy saving, IP65 environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source,.200 W suitable for highlighting architectural facade high mast and general purpose lighting . including cable 1. sqmm 3 core copper conductor and PVC conduit pipe 15 mm bore heavy duty ISI marked duly claimed with pole at 2 place complete all as specified and directed from light fitting to over head line. | | 7 | Each |
|---|
| 67 | 67 | S&F in repair New generation energy saving and environmental friendly long life LED Street Light made up of pressor die cast aluminium housing with high power LED as 60W lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP 66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device.60W LED including cable 1.5 sqmm 3 core copper conductor and PVC conduit pipe 15 mm bore heavy duty ISI marked duly claiped with pole at 2 place complete all as specified and directed from light fitting to over head line. | | 15 | Each |
|---|
| 68 | 68 | S&F in repair new Automatic street light Control Switch with INFRARED SENSOR based NATURE switch & voltage monitoring System (VMS) on light iux * ievel.suitable power Contactor,MCB and support Termite should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof, Termite proof and Termite proof and FR grade special moulding compound (Sintex make SMC junction box ) conforming to IP54. The contactors, MCBs and circuit wiring should suitable enough to take load of 25 kw equally distribution over Three phase 415 Volts A/C. | | 2 | Each |
|---|
| 69 | 69 | S&F in repair new generation, Post-top energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as Light source, 25W,RUBY (CLEAR)- IP 65 protection including cable 1.5 sqmm 3 core copper conductor and PVC conduit pipe 15 mm bore heavy duty ISI marked, complete all as specified and directed. | | 16 | Each |
|---|
| 70 | 70 | S&F in repair, MCB TPN, 63 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.\n | | 4 | EACH |
|---|
| 71 | 71 | Supply, fixing in repair MCCB 100 Amps , 4 pole, 415 volt AC supply, having breaking capacity 16 KA and with adjustable load setting including sheet metal enclosure for MCCB Complete all as specified and directed. | | 2 | Each |
|---|
| 72 | 72 | S&F in repair new PVC insulated sheathed stranded Aluminium conductor cable twin core 4 Sqmm size for connecting from Over head conductor to street light fittings with connector etc complete all as specified and directed. | | 200 | RM |
|---|
| 73 | 73 | Supplying & fixing in repair new PVC insulated sheathed stranded Aluminium conductor cable twin core 6 Sqmm size for connecting from Over head conductor to street light fittings with connector etc complete all as specified and directed. | | 200 | RM |
|---|
| 74 | 74 | Disconnecting and taking out existing MS boxes of any description and in any position on poles or fixed in the plinth of poles and supplying and fixing in position new PVC (Synthetic ) boxes of size 280mm X 170mm X 115mm depth, made out with Synthetic. The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of ‘C’ series, 5/6 Amps of Make Legrand/L&T/ Siemens and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminium lugs etc fixed on pole using 30x5 mm FI clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. \nNote :- The contractors quoted rates for the above items are deemed to include for fixing the Synthetic box in position with suitable MS clamps and/or necessary PCC as per site requirement.\n\n | | 20 | Each Job |
|---|
| 75 | 75 | Supplying ,Laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminium conductor cable 25 Sqmm 2 core 1100 volts grade, laid in trenches/ducts, floors, fixed to pole/ walls etc. including taking down complete all as specified and directed by the Engineer-in-charge. | | 100 | RM |
|---|
| 76 | 76 | All as per ser item No. 62.00 above but 16 Sqmm 2 core. | | 100 | RM |
|---|
| 77 | 77 | All as per ser item No. 62.00 above but 10 Sqmm 2 core. | | 100 | RM |
|---|
| 78 | 78 | All as per ser item No. 62.00 above but 50 Sqmm 2 core. | | 100 | RM |
|---|
| 79 | 79 | Disconnecting & Taking out old unserviceable joints and Supplying, Fixing, jointing and testing for provision of straight through joints, epoxy type with epoxy jointing materials, suitable for XLPE, LT Cable, 1100 Volts grade, for 10 Sqmm to 16 Sqmm any core the following sizes of cables all as specified and directed. | | 5 | Each |
|---|
| 80 | 80 | All as per serial item No. 66.00 above but 25 Sqmm to 35 Sqmm 3½ core | | 5 | Each |
|---|
| 81 | 81 | All as per serial item No. 66.00 above but 25 Sqmm to 35 Sqmm 3½ core | | 5 | Each |
|---|
| 82 | 82 | Disconnecting existing LT over heated or burnt cable terminal Joint for LT aluminium conductor cable of size 10 to 25 Sqmm of any core at existing panel/ board/feeder pillar box /overhead lines etc., cutting out over heated / burnt / unserviceable end portion of cable, stretching / opening cable to suitable required length from available rings etc and fixing and connecting the cable in position properly by providing suitable new aluminium lugs and suitable GI nuts, bolts & washers etc complete all as specified and directed.\n | | 6 | Each |
|---|
| 83 | 83 | All as per ser item No. 69.00 above but LT aluminium conductor cable of size 35 to 70 Sqmm of any core. | | 6 | Each |
|---|
| 84 | 84 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface to required slope/gradient for laying cables/protection pipes etc complete all as specified and directed by Engineer-in-Charge including removing cable covers carefully & stacking properly for re-use all as directed. | | 50 | Cum |
|---|
| 85 | 85 | Returning, filling in, including spreading, levelling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed. | | 38 | Cum |
|---|
| 86 | 86 | Removal of surplus excavated spoil not exceeding 50 metre distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 metre above the starting point complete all as specified. | | 12 | Cum |
|---|
| 87 | 87 | M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.\nNote:-Punned thickness shall be measurement & paid. | | 10 | Cum |
|---|
| 88 | 88 | Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed by Engineer-in-Charge. | | 1 | Per 1000 Nos |
|---|
| 89 | 89 | M&L for surface excavation over the areas around the poles/feeder piller boxes/ sub stations not exceeding 15mm depth including cleaning the bushes and vegetation and levelling incl removal of surplus soil in soft/hard dense soil. | | 2000 | Sqm |
|---|
| 90 | 90 | Trimming/cutting of all trees branches and cleaning of buses upto 3.0 mtr distance both side from nearest conductor/Earth Wire at LT overhead line including cleaning of site and depositing of material upto 250 mtr distance all as directed at site by Engineer-in-Charge | | 2000 | RM |
|---|
| 91 | 91 | Supply, fixing, connecting & testing and replacement of sheet metal enclosures double pole, 2 way DBs for using MCBs / MCB isolators without bus bar with and including one MCB SPN 16 Amp complete all as specified & directed.\n | | 4 | Each |
|---|
| 92 | 92 | S&F MCB single pole & Neutral 63 Amps, 10 KA ,240 Volts complete all as specified. | | 4 | Each |
|---|
| 93 | 93 | S&F MCB single pole 6 to 32 Amps, 10 KA , 240 Volts complete all as specified. | | 6 | Each |
|---|
| 94 | 94 | Dismantling old unserviceable cross arms and Supply, fabrication and fixing for mild steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description of LT over head line poles/ street light poles complete all as specified & directed.\n | | 1 | Qtl |
|---|
| 95 | 95 | Disconnecting and taking out the old existing LED street light fitting / security light fitting / Flood light fitting and electric connections remove by carbon ,cut cable connection and re connect ,after repair of any description and in any position from poles / walls / pillars etc. complete and U/S LED street light depositing in MES store yard and collect any type street light and fixing all as directed | | 40 | Each |
|---|
| 96 | 96 | Supply only Driver 45/48W. | | 10 | Each |
|---|
| 97 | 97 | Supply only Driver 60W. | | 10 | Each |
|---|
| 98 | 98 | Supply only Driver 100W. | | 8 | Each |
|---|
| 99 | 99 | Labour only for checking the serviceability of different spares / components / parts of High mast light fittings (HPSV, HPMV, Metal Halide fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, cleaning acrylic/glass cover connecting to electric supply and its testing on installation etc complete all as specified and directed. | | 2 | Each Job |
|---|