Uttaranchal Jal Vidyut Nigam Limited has published Design Engineering Supply Installation Integration Testing And Commissioning Of Telemetry And Data Management System For Amr Of Abt Meters Of 10 No Power Houses To Sldc Dehradun As Per Tender Documents. Submission Date for this Tender is 11-05-2021. Application Software Tenders in Differnt sites of UJVNL PH in Uttarakhand Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Apr-2021 | Date extension | Date | 11-05-2021 |
2 | 06-May-2021 | EMD Exemption | Fee | 11-05-2021 |
Name of Work:Design, Engineering, Supply, Installation, Integration, testing and Commissioning of Telemetry and data management system for AMR of ABT Meters of 10 no Power Houses to SLDC Dehradun | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply (as per Technical Specification) | |||
2 | 1.01 | Supply of complete Telemetry System for remote end with all accessories of Telemetry System for AMR of ABT meters from UJVNL Power houses to SLDC Dehradun. (For 10 Power Houses) | BI01010001010000000000000515BI0100001112 | 10 | Set |
3 | 1.02 | Supply of Data Management cum Fault monitoring system with all accessories | BI01010001010000000000000515BI0100001113 | 10 | Set |
4 | 1.03 | Enclosure Panel (Size: as per site fit) CRC Sheet with Powder coated IP54 with all wiring material.Make: Rittal/ Hoffman nvent /Energy Electricals/ MB control/IALS/PMAS/Secure/ | BI01010001010000000000000515BI0100001114 | 10 | Set |
5 | 1.04 | Supply of complete SCADA system (for AMR + LDMS system) at remote end with all accessories compatible with telemetry panel(For 10 Plants) | BI01010001010000000000000515BI0100001115 | 10 | Set |
6 | 1.05 | Supply of Central Monitoring DCU Panel for server end with all accessories ( For PTCUL Premises Dehradun) (System should be suitable for collection of 16 plants data from remote Panels of different power houses of UJVNL.) | BI01010001010000000000000515BI0100001116 | 1 | Set |
7 | 1.06 | Supply of complete SCADA system (for AMR/ Real Time Monitoring system) for server end with all accessories as per compliance with telemetry panel (For PITCUL/UJVNL Premises Dehradun 02 Nos. server PC compatible with telemetry panel (1 at PTCUL & 1 at UJVNL, Dehradun)) | BI01010001010000000000000515BI0100001117 | 1 | Set |
8 | 1.07 | Data cable Make – Sterlite, D-Link, Havels, Polycab,Kei, RRkabel | BI01010001010000000000000515BI0100001118 | 10000 | Mtrs. |
9 | 1.08 | 12F, OFC armored cable Make: Sterlite, Havells, D-Link, LAPP, Usha- Martine, | BI01010001010000000000000515BI0100001119 | 5500 | Mtrs. |
10 | 1.09 | Industrial grade Media Converter with LIU (Ethernet to OFC cable) Make: Moxa, Alcatel-Lucent D-Link, Seimens, Cisco | BI01010001010000000000000515BI0100001120 | 12 | No. |
11 | 1.1 | Industrial grade Media Converter with LIU ( OFC cable to Ethernet) Make: Moxa, Alcatel-Lucent D-Link, Seimens, Cisco | BI01010001010000000000000515BI0100001121 | 12 | No. |
12 | 1.11 | Industrial grade Converter ( RS 485 to Ethernet) Make: Moxa, Alcatel-Lucent D-Link, Seimens, Cisco | BI01010001010000000000000515BI0100001122 | 12 | No. |
13 | 1.12 | Industrial Grade Ethernet switch 26 + 4 SFP with LIU Make: Moxa, Alcatel-Lucent D-Link, Seimens, Cisco, ABB,GE | BI01010001010000000000000515BI0100001123 | 12 | No. |
14 | 1.13 | USB to Serial Converter ( RS 485/RS422/RS232 to USB) Make: Moxa, Alcatel-Lucent D-Link, Seimens, Cisco, ABB, GE | BI01010001010000000000000515BI0100001124 | 12 | No. |
15 | 2 | Work | |||
16 | 2.01 | Installation of telemetry Panels, Software development, Testing and Commissioning for SCADA/Real time Monitoring system and telemetry Panel including all required work for communication with ABT Meters and PC including, Fiber cable laying and termination, Convertor Installation and all required consumable material like paroles, clips etc (For 10 Power Houses)Dismantling/rearrangement of old panel including loading unloading and Transportation charges up to respective store of power house. | BI01010001010000000000000515BI0100001126 | 10 | Job |
17 | 2.02 | Installation of Telemetry Panels, Software development, Testing and Commissioning for SCADA/Real time Monitoring system and all field telemetry Panel including all required work for communication with all 13 no telemetry Panels from different locations and remote monitoring PC. (For PTCUL Premises Dehradun & remote monitoring at UJVNL ) | BI01010001010000000000000515BI0100001127 | 1 | Job |
18 | 2.03 | Point to Point Lease Line with redundancy on 4G/3G Gateway with required networking hardware at all location | BI01010001010000000000000515BI0100001128 | 13 | Job |
19 | 2.04 | 2 year AMC Charges after warranty period per annum basis | BI01010001010000000000000515BI0100001129 | 2 | Job |