Imp Of Water Supply At Chota Enaka Goal Tikery Model School And Veterinary Complex At Kmt Co Treatment Plant 01 Sedimentation Tank And 02 Nos Filter Bed Of 60 Sqm Each Cwr Of 120000 Ltrs Capacity And Steel Ohtof 120000 Ltrs And Pump House At Kamorta Imp , Kamorta-Andaman And Nicobar Islands

Public Works Department-PWD has published Imp Of Water Supply At Chota Enaka Goal Tikery Model School And Veterinary Complex At Kmt Co Treatment Plant 01 Sedimentation Tank And 02 Nos Filter Bed Of 60 Sqm Each Cwr Of 120000 Ltrs Capacity And Steel Ohtof 120000 Ltrs And Pump House At Kamorta Imp . Submission Date for this Tender is 13-04-2021. Pump House Construction Tenders in Kamorta Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

27522158
Imp Of Water Supply At Chota Enaka Goal Tikery Model School And Veterinary Complex At Kmt Co Treatment Plant 01 Sedimentation Tank And 02 Nos Filter Bed Of 60 Sqm Each Cwr Of 120000 Ltrs Capacity And Steel Ohtof 120000 Ltrs And Pump House At Kamorta Imp
Open Tender
Indian
Andaman And Nicobar Islands
Kamorta
13-04-2021

Tender Details

Imp Of Water Supply At Chota Enaka Goal Tikery Model School And Veterinary Complex At Kmt Co Treatment Plant 01 Sedimentation Tank And 02 Nos Filter Bed Of 60 Sqm Each Cwr Of 120000 Ltrs Capacity And Steel Ohtof 120000 Ltrs And Pump House At Kamorta Imp Of Water Supply At Chota Enaka Goal Tikery Model School And Veterinary Complex At Kmt Co Treatment Plant 01 Sedimentation Tank And 02 Nos Filter Bed Of 60 Sqm Each Cwr Of 120000 Ltrs Capacity And Steel Ohtof 120000 Ltrs And Pump House At Kamorta

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 1.85 Crore /-

BOQ Items

Name of Work: Improvement of water supply at Chota Enaka, Goal Tikery Model Schooland Veterinary Complex at Kamorta SW : Construction of treatment plant (01 Sedimentation tank and 02 Nos filter bed of 60 sqm each), CWR of 1,20,000ltrs capacity and steel overhead tank of 1,20,000ltrs capacity pump house at kamorta (3rd Call)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
2All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
4All kinds of soil.
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
81:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
91:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
101:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
11Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete.
121:1½:3 (1 Cement: 1½ coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
13Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
14Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
151:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
16Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
171:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
18Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
19Centering and shuttering including strutting, propping etc. and removal of form for:
20Foundations, footings, bases of columns, etc. for mass concrete
21Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
22Suspended floors, roofs, landings, balconies and access platform
23Lintels, beams, plinth beams, girders, bressumers and cantilevers
24Columns, Pillars, Piers, Abutments, Posts and Struts
25Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
26Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
27Thermo-Mechanically Treated bars of grade Fe-500D or more.
28Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
29Kiln seasoned and chemically treated hollock wood
30Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
3130 mm thick Kiln seasoned and chemically treated hollock
32Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
33Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
3480x0.90 mm M.S. laths with 0.90 mm thick top cover
35Providing and fixing ball bearing for rolling shutters.
36Providing and fixing bolts including nuts and washers complete.
37Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
38Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
3940 mm thick with 20 mm nominal size stone aggregate
40Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
4175 mm diameter
42Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
43Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
44Ridges plain (500 - 600mm)
4512 mm cement plaster of mix :
461:4 (1 cement: 4 fine sand)
4712 mm cement plaster finished with a floating coat of neat cement of mix :
481:4 (1 cement: 4 fine sand)
496 mm cement plaster of mix :
501:3 (1 cement : 3 fine sand)
51Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification.
52Two or more coats on new work
53Finishing walls with Acrylic Smooth exterior paint of required shade :
54New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
55Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
56New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
57Applying priming coat:
58With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
59Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
60Two or more coats on new work
61Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
6280 mm dia nominal bore
63Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
6480 mm nominal bore
65Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class):
66Up to 300 mm dia
67Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
68Up to 300 mm dia
69Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :
70100 mm diameter pipe
71Supplying pig lead at site of work.
72Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints :
73100 mm diameter pipe
74Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
75100 mm diameter Class II
76Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :
77100 mm dia Ductile Iron Class K-7 pipes
78Supply and stacking i/c laying of 53 to 24mm stone agrregate for filter media.
79Supply and stackingof 13.5 mm stone agrregate for filter media.
80Supply and filling with river sand for treatment plant as slow sandfilter media.
81Constructing masonry Chamber 90x90x100 cm inside, withcement concrete1:3:6 (1 cement : 3 coarse sand:6 graded stone aggregate ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard designand as per the direction of Engineer in-charge.
82Fabrication,supply & errection of Galvanized press steel water tank of size 8.75x5.00x2.50 mtr having 109200 liter capacity with decking and will all accessories such as nuts & bolts sheet cover inlet,outlet over flow pipe connection lead wool lead wire etc.Total weight of the materials is 9465 (List attached as per code.)
83Fabrication,supply & errection of Galvanized steel staging of mtr.Height staging for above tank inside all around platform.Total weight of the ,aterials is 14761 kg (List attached as per code.)
84Providing cement concrete surface drain including earthwork excavation 10 cm thick base concrete and 15 cm thick side wall with 1:4:8 (1 Cement: 4 coarse sand :8 graded stone aggregate 40 mm nominal Size) cement concrete finishing with 1:4 (1 cement : 4 sand ) a floating coat of neat cement inside the drain and its top and exposed surface, including earth work in excavation and disposed of surface earth etc.
85Providing and fixing in position eaves or facia board with 18 mm thick WPC/PVC board (SIR brand with a density of 0.54-0.70 grm/cc, weather chemical and corrosion resistant and also Fire retardant and non toxic) of 30 cm wide including fixing with nuts and bolts retc complete.
86Providing and laying Hollow C.C Block walling 200 mm thick consisting hollow block of size 400 x 200 x 200 mm of mix 1:3:6having crushing strength of 3.5 N/sqmat 28 days as per IS 2185 including hoisting and setting in position with cement morter 1:6 (1cement : 6coarse sand).
87Providing, Installation testing and commissioning of 01 No. 30 HP/22 KW , 3-Phase, 4+Pole, 415 Volts± 10%, 50 Hz± 5% designed to run at 1500 RPM, with "F" class insulation and temperature rise limit upto class "B" and has to be totally enclosed fan cooled squirrel cage inducation, motor, similar to kirlosker/crompton Greaves make soupled with water Pump similar to Kirloskar make, model DSM 65/32A or equivalent to C.I make, C.I impeller having a suction and delivery of 80 x 65 mm with a minimum discharge of 20.00 LPS at 50.0 mtrs of head including supplying and installation of base frame with foundation bolts and nuts, coupling assembly, coupling gaurd, C.I foot valve (80 mm ) etc. as required.
88Providing, Installation testing and commissioning of 01 No. 30 HP designed to run at 1500 RPM, four cylinder, water cooled, Vertical Diesel Oil engine similar to irloskar make model No. 3R - 10140 coupled with water pump similar to kirlosker make, model DSM 65/32A or equivalent to C.I make, C.I impeller having a suction and delivery of 80 x 65 mm with a minimum discharge of 20.00 LPS at 50.0 mtrs of head including supplying of 01 Nos 12 V, 180 AH battery with cable and supplying and installation of base frame with foundation bolts and nuts, coupling assembly, coupling with gaurd, C.I foot valve (80 mm ), fuel tank assembly for 8:00 Hrs. along with stand and fuel line hose etc. as required.
89Providing, Installation testing and commissioning of 01 No. 10 HP/7.5 KW , 3-Phase, 4+Pole, 415 Volts ± 10%, 50 Hz± 5% designed run at 1500 RPM, with "F" class insulation and temperature rise limit upto class "B" and has to be totally enclosed fan cooled squirrel cage inducation, motor, similar to kirlosker/crompton Greaves make coupled with horizontal centrifugal water Pump similar to Kirloskar make, model SCT 80/30, single stage, C.I impeller having a suction and delivery of 100 x 80 mm with a minimum discharge of 10.00 LPS at a head of 25.00 mtrs including supplying and installation of base frame with foundation bolts and nuts, coupling assembly, coupling gaurd, C.I foot valve (100 mm ) etc. as required.
90Providing, Installation testing and commissioning of 01 No. 20 HP, vertival diesel Oil engine designed to run at 1500 RPM, two cylinder, water cooled, with fuel tank assembly similar to kirlosker make model DM-20 coupled with horizontal centrifugal water pump similar to kirloskar make, model SCT 80/30, single stage C.I. impeller having a suction and delivery of 100 x 80 mm with a minimum discharge of 10.00 LPS at a head of 25.00 mtrs including supplying of 01 No. hand start handle and supplying and installation of base frame with foundation bolts and nuts, coupling assembly, coupling with gaurd, C.I foot valve (100 mm ), etc. as required.
91Supplying and drawing 7 X 10 Sqm of FR PVC insulated cooper condutor, single core in the existing HDPE pipe as required
92Supplying and drawing 7 X 25 Sqm of FR PVC insulated cooper condutor, single core in the existing HDPE pipe as required
93Supplying of 50.00 mm outer diameter with minimum wall thickness of 3.50 mm one number High Density Poyethlene pipe (HDPE) for cable protection coforming to IS: 4984-1995 & IS-14151-1994 duly ISI marked.
94Supplying of 25 sq.mm, 3.5 core PVC insulated and PVC sheathed/XLPE (heavy duty) Armoured 1.1 KV grade Aluminium conductor cable conforming to IS: 7098 (Part-I).
95Supplying of 50 sq.mm, 3 1/2core PVC insulated and PVC sheathed/XLPE (heavy duty) Armoured 1.1 KV grade Aluminium conductor cable conforming to IS: 7098 (Part-I).
96Laying of one number PVC insulated and PVC Sheathed/XLPE power cable of 1.1 grade of following size in the existing RCC/HUME/METAL pipe as required.
97(a) Above 35sq.mm
98Laying of one number PVC insulated and PVC Sheathed/XLPE power cable of 1.1 grade of following size in the existing RCC/HUME/METAL pipe as required.
99(a) Upto 35sq.mm
100Earthing with copper earth plate 6 mm X 600 mm X 3mm thick including accessories, ad providing masonry enclosed with cover plate having locking arrangement and wastering pipe of 2.7 meter long etc. with charcoal/coke and selt as required.
101Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. Pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
102Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connection etc. as required.
103Supplying, Installation, testing and commissioning of indoor type mounted cubical panel board. a). MCCB 100 Amps/TPN (Four Pole)- 25 KA breaking capacity- 01 No.b). Analog Ammeter (0 to 100 A) - 01 No. c). Analog Voltmeter (0 to 500 V)- 01 No. d). C.T. Coil, Class “B”, with ration of 5/100 A - 01 No. e). Three Phase Selector switch (for voltmeter and Ammeter)- 01 No. f). Single Phase Preventer relay of suitable range - 01 No. g). Fully automic star delta starter of 35 HP, 3 – Phase, 415 volts – 01 No. h). Indication lamp with backup fuse (RYB) - 01 Set. i). Copper bus bar strip of size 40 x 5 x 500 mm length for RYB – 01 Set. j). Rewritable porcelain fuse unit with neutral link 100 A (RYBN) with extension strip – 01 Set k).Power factor correction capacitor, box type of 1 KVAR, 440 Volts. – 01 set. l). Inter connection with 16.0 Sq. mm PVC copper etc. as required.
104Supplying, Installation, testing and commissioning of indoor type mounted cubical panel board. MCCB 63 Amps, 415 V, pole 16 KA breaking capacity - 01 No. MCCB 40 /TPN (Four Pole) – 10 KA LM series - 01 No. Analog Ammeter (0 to 100 A) - 01 No. Analog Voltmeter (0 to 500 V) - 01 No. C.T. Coil, Class “B”, with ration of 5/100 A - 01 No. Three Phase Selector switch (for voltmeter and Ammeter) - 01 No. Single Phase Preventer relay of suitable range - 01 No. Fully automic star delta starter of 12.5 HP,9.0 KW, (12-18 A relay range) – 3 Phase. Indication lamp with backup fuse (RYB) - 01 Set. Copper bus bar strip of size 40 x 5 x 500 mm length for RYB – 01 Set. Rewritable porcelain fuse unit100 A /415 V (RYB) – 01 Set Power factor correction capacitor, box type of 1 KVAR, 440 Volts. – 01 set. Inter connection with 16.0 Sq. mm PVC copper etc. as required.
105Wiring for light point/fan point/ exhaust fan point/call point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit,
106Wiring for light/point plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS
107Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducotor, single core cable in surface/recessed medium clas PVC conduit as required.
1082 x 1.5 sq. mm + 1x 1.5 sq. mm earth wire.
1092 x 6 sq. mm + 1x 1.6 sq. mm earth wire.
110Supplying and fixing metal box of 150 mm X 75 mm 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outler and 5/6 A piano type switch. connections, painting etc. as required.
111Supplying and fixing PVC batten/angle holder including connections etc. as required.
112Supplying and prewired box type fluorescent tube lamp fitting 4 x 40 w, (single with copper ballast) similar to Bajaj Cat No. BJCEB 140 WEB with starter, tube etc. as required.
113Installation testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube/lamp etc. directly on ceiling/well, including conductor, single core cable and earthing etc. required.
114Supplying of A.C Celling fan (120 mm sweep white colour) i/ec down rods of standard length 30 cm with all accessories etc. as required Make Havells/Usha/Bajaj/Orient or equivalent standard
115Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (Upto 30 cm) with 1.5 Sq.mm FR PVC insulated, copper conductor, single core cable and earthling etc. as required.
116Supplying and fixing step type electronic (socket type) fan regulator in the existing switch board with all accessories etc. as required.
117Supplying and fixing 6 way, Double door, single and neutral, sheet steel, MCB distribution board 240 volts on surface/recess complete with tanned copper bus bar, neutral bus bar, earth bar, interconnection power pointed including earthling etc. as required. (But withoutMCB/RCCB/Isolator).
118Supplying and fixing 40 A, double pole, 240 volts, Isolator in the existing MCB DB complete with connection, testing and commissioning etc., as required.
119Supplying and fixing 5 A, to 32 A rating, 240/145V, 10 KA, “C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. asrequired.
120Supplying and fixing of 15 W, 240 V retrofit CFL of base B 22 lamps
Disclaimer :