| 1 | 1 | Disconnecting all electric connections of central air heating system of capacity 10 TR (3 Units) and Material and labour for periodical servicing/maintenance of Central heating system to be carried out including replacement of following wornt out/defective spares parts complete including testing all as directed by Engr-in-Charge . Notes :- \n(a) All new spare parts shall be measured and paid for separately as supply only. (b) Cost of fixing of these items however shall be deemed to be included in the rate quoted against item No.1.00 \n(c) Cost of Sundry items such as nuts, bolts, washers, copper washers etc shall be deemed to be included in quoted rates. (d) Servicing of plant set will be carried out after a period of 6 months or as required. | | 3 | EACH\nJOB |
|---|
| 2 | 2 | Strip opening of motor squirrel cage induction of motor capacity 3 HP, 440 volts 1500 RPM and rewinding with supper enamelled copper conductor wire as per existing gauge and number of turns including insulation material and taking out from its original poition and transportation from site to workshop complete all as directed. \nMake of wire : ALTAS/Birla/DEVI DAYAL | | 3 | EACH\nJOB |
|---|
| 3 | 3 | M&L for duct wiring with PVC insulated copper conductor sheathed cable of size 10/6 sqmm for panel strip heater, blower motor pump cooling pump tower and compressor unit including taking out old unserviceable complete all as directed. | | 3 | EACH\nJOB |
|---|
| 4 | 4 | M&L for blower drum suitable for AC Plant and water dispenser including replacement of hot water tank including taking out old unserviceable complete all as directed. | | 6 | EACH |
|---|
| 5 | 5 | M&L for strip heater of 3 KW capacity of existing size and model including taking out old unserviceable complete all as directed. | | 15 | EACH |
|---|
| 6 | 6 | M&L for contactor 32 amp 440 volts including taking out old unserviceable complete all as directed.\n | | 10 | EACH |
|---|
| 7 | 7 | M&L for shaft and bearing of blower driven assembly complete as per exisiting make and model including taking out old unserviceable complete all as directed. | | 5 | EACH JOB |
|---|
| 8 | 8 | M&L for repair to electric panel with replacement of contractor overload relay, ampere meter voltmeter, MCCB, control wiring & interlock connections complete including taking out old unserviceable complete all as specified and directed by Engr-in Charge of following wornt out/defective spares parts complete including testing all as directed by Engr-in-Charge and comprising as under:- | | 4 | EACH\nJOB |
|---|
| 9 | 8.1 | (a) Contactor overload relay -1 No | | | |
|---|
| 10 | 8.2 | (b) Ampere meter and volt meter -1 No Each | | | |
|---|
| 11 | 8.3 | (c) MCCB, 100 amp 25 KA -1 No | | | |
|---|
| 12 | 9 | Taking down carefully split type/Window type Air conditioners of capacity 1.5 Ton of any make for carrying out the repais work at workshop including transportation (Nathatop to Udhampur and back) complete all as specified and as directed by Engr-in-Charge. \nNote :- Spares required for repair work will be measured and paid for separately under respective item of BOQ | | 4 | EACH\nJOB |
|---|
| 13 | 10 | Disconnecting, cutting and taking out unseviceable sealed unit compressor of Split AC 1.5 Ton including clean exchange of unserviceable compressor and replacing with new sealed unit compressor including soldering /brazing as required including gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.\nMake : Voltas/Bluestar/LLoyd/Carrier\nNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. | | 4 | EACH\nJOB |
|---|
| 14 | 11 | Disconnecting, cutting and taking out unseviceable sealed unit compressor of Split AC 2 Ton including clean exchange of unserviceable compressor and replacing with new sealed unit compressor including soldering /brazing as required including gas charging in the compressor making electrical and machanical connections all inclusive and testing on load complete all as specified and directed by the Engineer-in-charge.\nMake : Voltas/Bluestar/LLoyd/Carrier\nNote :- The cost of gas shall be deemed to be included in the rate quoted and nothing extra shall be admissible on this account. | | 4 | EACH\nJOB |
|---|
| 15 | 12 | S&F thermostate switch for 1.5 Ton capacity Air conditioner single phase 240 Volts and 2 Ton Air conditioner 220 Volts,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.\nMake :- Renutrol/Indfoss or equivalent as approved by GE. | | 4 | EACH |
|---|
| 16 | 13 | S&F control card of inner unit of 1.5 Ton AC, ,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 4 | EACH |
|---|
| 17 | 14 | S&F control card of inner unit of 2.0 Ton AC, ,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 4 | EACH |
|---|
| 18 | 15 | S&F Indoor unit blower with fan and bushes for 1.5 Ton capacity AC,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 2 | EACH |
|---|
| 19 | 16 | S&F Indoor unit blower with fan and bushes for 2.0 Ton capacity AC,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 3 | EACH |
|---|
| 20 | 17 | S&F Hot and cold valve for 1.5/2.0 Ton capacity AC, including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.. | | 2 | EACH |
|---|
| 21 | 18 | Rewinding of blower motor of window type AC 1.5/2.0 Ton capacity any make and model of size 1/5 HP with super enamelled copper winding wire of suitable size and gauge, varnishing, drying, baking and insulation paper including replacement of gunmetal bushes/bearing, fixing and testing on load complete all as specified and directed by Engineer-in-Charge. | | 6 | EACH\nJOB |
|---|
| 22 | 19 | S&F capacitor 10 mfd + 10 mfd (combined unit), including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.\n\nMake :- Apcos/Natraj/Tesla/Spark | | 4 | EACH |
|---|
| 23 | 20 | S&F capacitor 15 mfd + 10 mfd (combined unit),including taking down old unserviceable,complete all as specified and directed by Engr-in-charge\n.\nMake :- Apcos/Natraj/Tesla/Spark | | 4 | EACH |
|---|
| 24 | 21 | S&F capacitor 36 mfd + 10 mfd (combined unit), including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.\nMake :- Apcos/Natraj/Tesla/Spark | | 5 | EACH |
|---|
| 25 | 22 | S&F starting relay of 1.5/2.0 Ton window/split, including taking down old unserviceable,complete all as specified and directed by Engr-in-charge..\nMake :- Renutrol/Indfoss | | 6 | EACH |
|---|
| 26 | 23 | S&F route pipe (copper tube) of size 3/8\" dia complete with insulation including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 45 | RUNNING\nMETRE |
|---|
| 27 | 24 | S&F route pipe (copper tube) of size 5/8\" dia complete with insulation, including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 45 | RUNNING\nMETRE |
|---|
| 28 | 25 | S&F route pipe (copper tube) of size 1/4\" dia complete with insulation, including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 45 | RUNNING\nMETRE |
|---|
| 29 | 26 | S&F radiator outdoor unit complete for 2.0 ton AC including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 8 | EACH |
|---|
| 30 | 27 | Supply and refilling of gas R-134a in any type of cooling appliances including necessary arrangement for gas filling all as specified and directed by Engineer-in-Charge. | | 220 | KILOGRAM |
|---|
| 31 | 28 | S&F of flair nut of size 1/4 inch complete including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 14 | EACH |
|---|
| 32 | 29 | S&F of flair nut of size 5/8 inch complete including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 14 | EACH |
|---|
| 33 | 30 | S&F of flair nut of size 3/8 inch complete including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 14 | EACH |
|---|
| 34 | 31 | S&F of flair nut of size 1/2 inch complete including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 14 | EACH |
|---|
| 35 | 32 | Taking out the voltage stabilizer of capacity 3 to 5 KVA single phase and rewinding of the main transformer unit with standard copper enamelled wire and making connection (internal), testing the stabilizer to the entire satisfaction of Engineer-in-Charge, all as directed. | | 6 | EACH |
|---|
| 36 | 33 | S&F control card of voltage stabilizer PCB sensor etc.including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 6 | EACH |
|---|
| 37 | 34 | S&F selector switch for input and output voltage including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 6 | EACH |
|---|
| 38 | 35 | S&F Ics and relays including taking down old unserviceable,complete all as specified and directed by Engr-in-charge. | | 6 | EACH |
|---|
| 39 | 36 | Disconnecting the Refrigerator of capacity 280/310 Ltr and replacement of following parts, reassembly of unit and testing the same to the entire satisfaction of the Engineer-in-Charge. | | 4 | EACH\nJOB |
|---|
| 40 | 36.1 | (a compressor sealed unit including necessary brazing work as required. | | 5 | EACH |
|---|
| 41 | 36.2 | (b)Thermostate switch suitable for 280/310 Ltrs capacity refrigerator.\nMake :- INDO FOSS/TESLA/ SPARK/NATRAJ | | 4 | EACH |
|---|
| 42 | 36.3 | (c) Thermal overload relay for 280/310 Ltrs capacity refrigerator.\nMake :- INDO FOSS/TESLA/SPARK/NATRAJ | | 6 | EACH |
|---|
| 43 | 37 | Disconnecting the refrigerator of capacity 165/210 ltr and replacement of the following spares required for repair work including reassembly and testing all as directed. | | 6 | EACH\nJOB |
|---|
| 44 | 37.1 | (a) Thermostate switch suitable for 165/210 Ltrs capacity refrigerator.\nMake :- INDO FOSS /TESLA/ SPARK/ NATRAJ | | 3 | EACH |
|---|
| 45 | 37.2 | (b) Capilliary tube including brazing work. | | 4 | EACH |
|---|
| 46 | 37.3 | (c) Thermal over load relay. | | 3 | EACH |
|---|
| 47 | 37.4 | (d) Compressor protection grill. | | 4 | EACH |
|---|
| 48 | 37.5 | (e) Ics and relay. | | 4 | EACH |
|---|
| 49 | 37.6 | (e) compressor unit | | 2 | EACH |
|---|
| 50 | 38 | Taking out Deep Freezer 320 Ltr capacity 230 V AC 50HZ , supply and replacement of following unserviceable parts, reassembling the same after repair and testing on load after completion of job, all as directed. | | 2 | EACH\nJOB |
|---|
| 51 | 38.1 | (a) Compressor sealed unit including necessary brazing work as required. | | 2 | EACH |
|---|
| 52 | 38.2 | (b) Thermal over load relay.\nMake :- INDO FOSS /TESLA/ SPARK/ NATRAJ | | 2 | EACH |
|---|
| 53 | 38.3 | (c) Thermostate switch.\nMake :-INDO FOSS /TESLA/ SPARK/ NATRAJ | | 2 | EACH |
|---|
| 54 | 39 | Taking down indoor/outdoor unit of capacity 1.5/2.0 ton capacity after opening electrical connections, securing the refrigerant gas in the compressor and opening refrigeration pipe line safely. Shifting the inddor/outdoor unit for fixing at new places, mounting after drilling hole over out door unit stands, connecting refrigeration pipe line with indoor unit, electrical connection and charging refrigeration gas complete all as specified and directed by Engr-in-Charge. \nNote :- Additional Refrigerant gas and copper pipe line and insulation will be measured and paid for separately. | | 5 | EACH\nJOB |
|---|
| 55 | 40 | Stands for outdoor unit including drilling hole, nuts bolts , fastners etc complete all as required at site. | | 6 | EACH\nJOB |
|---|
| 56 | 41 | Submain wiring with Four single core PVC insulated flexible copper conductor cable FRLS of size 4 sqmm and one single core PVC insulated flexible copper conductor cable of green colour of size 4.0 Sqmm as earth lead in & including surface PVC conduit light grade fixing to wall with clamps complete all as specified and directed by Engr-in-Charge including taking down old. \nNote: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. | | 430 | RUNNING\nMETRE |
|---|
| 57 | 42 | Material and labour for periodical servicing, maintenance of RO + UV System plants 150 LPH to be carried out and replacement of wornt out/defective spare parts including testing on complection all as specified and directed by Engr-in-Charge.\nMake :Renuka water treatment plant or equivalent to approved by GE. Notes :- \n(a) All new spare parts shall be measured and paid for separately as supply only. (b) Cost of fixing of these items however shall be deemed to be included in the rate quoted against item No.22.01 \n(c) Cost of Sundry items such as nuts, bolts, washers, copper washers etc shall be deemed to be included in quoted rates. (d) Servicing of plant set will be carried out after a period of 3 months or as required. | | 12 | EACH\nJOB |
|---|
| 58 | 43 | Supply only following spares only or RO plants : | | | |
|---|
| 59 | 43.1 | (a) R.O Element shell (item code No RWC 157RES440150, RWT-ROS-C150) for RO+UV system of capacity 150 LPH complete all as specified and directed . | | 9 | EACH |
|---|
| 60 | 43.2 | (b) R.O Element (item code No RWC 152RE440150, RWT-ROS-C150) | | 8 | EACH |
|---|
| 61 | 43.3 | (c) W S Valve (item code No RWC 201WS12150, Model No-RWT-ROS-C150) | | 11 | EACH |
|---|
| 62 | 43.4 | (d) Booster (item code No RWC 107HPP150, Model No-RWT-ROS-C150) | | 10 | EACH |
|---|
| 63 | 43.5 | (e) Control unit (item code No RWC 181CP1PH150, Model No- RWT-ROS-C150) | | 9 | EACH |
|---|
| 64 | 43.6 | (e) adaptor | | 7 | EACH |
|---|
| 65 | 44 | Material and labour for peroidical servicing, maintenance of RO + UV System plants 25/50 LPH to be carried out and replacement of wornt out/defective spare parts including testing on complection all as directed by Engr-in-Charge . Make :Renuka water treatment plant or equivalent ) Notes :- \n(a) All new spare parts shall be measured and paid for separately as supply only. (b) Cost of fixing of these items however shall be deemed to be included in the rate quoted against item No.22.08 \n(c) Cost of Sundry items such as nuts, bolts, washers, copper washers etc shall be deemed to be included in quoted rates. (d) Servicing of plant set will be carried out after a period of 3 months or as required. | | 16 | EACH\nJOB |
|---|
| 66 | 45 | Supply only following spares only or RO plants : | | | |
|---|
| 67 | 45.1 | (a) Housing/R.O Element shell (item code No RWI125, Model No. RWT-ROS-007) | | 18 | EACH |
|---|
| 68 | 45.2 | (b) R.O Element (item code No RWI127, Model No -RWT-ROS-007) | | 13 | EACH |
|---|
| 69 | 45.3 | (c) Micronic filter (item code No RWI107, Model No -RWT-ROS-007) | | 10 | EACH |
|---|
| 70 | 45.4 | (d) GAC Filter (item code No RWI110, Model No - RWT-ROS-007) | | 11 | EACH |
|---|
| 71 | 45.5 | (e) CTO Filter (item code No RWI109, Model No - RWT-ROS-007) | | 12 | EACH |
|---|
| 72 | 45.6 | (h) Micron shell (item code No RWI105, Model No - RWT-ROS-007) | | 11 | EACH |
|---|
| 73 | 46 | Material and labour for servicing and maintenance of hot water generators plants of capacity 1 lakh kilo calories per hour to be carried out and replacement of wornt out/defective spare parts including testing on completion all as specified and directed by Engr-in-Charge . Make- Rapid cool/ leader) Notes :- (i) All new spare parts shall be measured and paid for separately as supply only. (ii) Cost of fixing of these items however shall be deemed to be included in the rate quoted. (iii) Cost of Sundry items such as nuts, bolts, washers, copper washers etc shall be deemed to be included in quoted rates. (iv) Servicing of Plants will be carried out once in year or as rquired. | | 2 | EACH\nJOB |
|---|
| 74 | 47 | Supply only following spares only or hot water generators : | | | |
|---|
| 75 | 47.1 | (a) Burner Fire Ignition control Sensar suitable for Rapid cool make hot water generator | | 10 | EACH |
|---|
| 76 | 47.2 | (b) Oil Nozzle of size 2.5 mm x 60 mm suit able for Rapid cool make hot water generator | | 4 | EACH |
|---|
| 77 | 47.3 | (c) Hot water controller suitable for Rapid cool make hot water generator | | 2 | EACH |
|---|
| 78 | 47.4 | (d) Temparture controller suitable for Rapid cool make hot water generator | | 2 | EACH |
|---|
| 79 | 47.5 | (e) Ignition transformer suitable for Rapid cool make hot water generator | | 1 | EACH |
|---|
| 80 | 47.6 | (f) Metallic Hose pipe 3/8\" x 40 mm suitable for Rapid cool make hot water generator | | 4 | EACH |
|---|
| 81 | 47.7 | (g) HT Wire suitable for Rapid cool make hot water generator | | 10 | RM |
|---|
| 82 | 47.8 | (h) Carbon removeable chemical HD ( Dosing 200 gms every 30 days run of each unit ) | | 25 | KILO\nGRAM |
|---|
| 83 | 47.9 | (j) Water pressure gauge suitable for Rapid cool make hot water generator | | 2 | EACH |
|---|
| 84 | 48 | Taking down storage type water heater (Geyser) of capacity 25/35/50 litres after opening electrical connections, securing the water leakage from inlet water connection and Shifting the geysers for painting/numbering complete all as specified and directed by Engr-in-Charge. \nNote :- Wornt out parts and spares will be measured and paid for separately. | | 38 | EACH\nJOB |
|---|
| 85 | 49 | Dismantling Geyser of capacity 25/35 & 50 litres, taking out burnt out parts of geysers and replacement with new parts complete all as as specified and directed. (Make : Crompton/Bajaj/Usha/Recold ) \nNote :- Wornt out parts and spares will be measured and paid for separately. | | 38 | EACH\nJOB |
|---|
| 86 | 50 | Supply only of the following spares for geysers :- | | | |
|---|
| 87 | 50.1 | (i) Inner tank made out of copper/stainless steel of capacity 25/35 Ltrs. | | 27 | EACH |
|---|
| 88 | 50.2 | (ii) Inner tank made out of copper/stainless steel of capacity 50 Ltrs | | 32 | EACH |
|---|
| 89 | 50.3 | (iii) Heating element 2 KW. (Make- Recold/ Crompton/Bajaj/Usha) | | 42 | EACH |
|---|
| 90 | 50.4 | (iv) Heating element 1.5 KW. (Make- Recold/Crompton/Bajaj/Usha) | | 40 | EACH |
|---|
| 91 | 50.5 | (v) Heating element 1 KW. (Make- Recold/ Crompton/Bajaj/Usha) | | 38 | EACH |
|---|
| 92 | 50.6 | (vi) Thermostat switches | | 44 | EACH |
|---|
| 93 | 50.7 | (vii) Appartus plate for 25/35/50 litres capacity | | 28 | EACH |
|---|
| 94 | 50.8 | (viii) Indicating lamp. | | 26 | EACH |
|---|
| 95 | 51 | Scrapping of old painting and spray Painting of external surface of Geysers with two coats of white synthetic enamell paint over a coat of red oxide primer complete as directed, transporting from Udhampur to Nathatop and back and fixing complete including replacement of nuts/bolts all as specified and directed by Engineer-in-Charge. | | 33 | EACH\nJOB |
|---|
| 96 | 52 | Dismantling/opening of oil rediator of capacity 2000 watts and taking out burnt out parts of rediators and replacement with new parts complete all as specified and directed by Engineer-in-Charge. \nfor following :- (Make :- Crompton/Bajaj ) | | 35 | EACH\nJOB |
|---|
| 97 | 52.1 | (i) Heating element/coil of capacity 2000 watts | | 25 | EACH |
|---|
| 98 | 52.2 | (ii) Thermostat switches | | 28 | EACH |
|---|
| 99 | 52.3 | (iii) Indicating lamp regulating switch. | | 22 | EACH |
|---|
| 100 | 52.4 | (iv)Transformer oil of superior quality | | 120 | LITRE |
|---|
| 101 | 53 | Disconnecting and dismantling including transporting from Nathatop to Udhampur and back without any interruption of electric supply of UPS from system and main supply and making alternate arrangement for smooth functioning of the system at radar room at AF Nathatop complete all as specified and directed by Engineer-in-Charge. | | 2 | EACH\nJOB |
|---|
| 102 | 53.1 | Opening the UPS and repairing the main control card by replacing trickling circuit, charging circuit, integrated circuit, etc from the manufacturer and testing as per manufacturer's design all as directed by user at site. | | 2 | EACH\nJOB |
|---|
| 103 | 53.2 | (i) Replacement of resistance 1.5 OHM, 20 Watt as per sample. | | 2 | EACH |
|---|
| 104 | 53.3 | (ii) Replacement of DC capacitor ( 4300/UF/450 Volt) as per sample. | | 2 | EACH |
|---|
| 105 | 53.4 | (iii) Replacement of bridge block 3 phase HD 12/12 as per sample. | | 2 | EACH |
|---|
| 106 | 53.5 | (iv) Replacement of IGBT (Make :- U PACK GERMANY or equivalent as approved by GE). | | 2 | EACH |
|---|
| 107 | 53.6 | (v) Replacement of capacitor 2 MFD 20 Watt as per sample.\n Make :- Apcos/Natraj/Tesla/Spark | | 2 | EACH |
|---|
| 108 | 54 | Reassembling the UPS after necessary repairs, installation and testing at site including transportation and testing complete all as specified and directed by Engineer-in-Charge. | | 2 | EACH\nJOB |
|---|
| 109 | 55 | M&L for replacement of existing unserviceable batteries of 45 AH, 12 volts, all as specified and directed.\nMake: EXIDE/Amron/AMCO/Okaya/Sukam/Microtek. | | 16 | EACH |
|---|
| 110 | 56 | Dismantling of old damage, leakage and unserviceable SMC/PUF insulated panel of tank of any size and supply and fixed SMC/PUF insulated panels of size 1.00 m x 1.00 m matching to existing with all fittings such as nuts, bolts, washers and M-seal tape for SMC /PUF insulated tank of capacity 27000 litres installed at stage-I complete all as specified and directed.\nMake :- Panel should be conforming to Sintex Code No.GS-PT-027-S3 or equivalent in other approved MES make.\nNote :- The rates quoted against this item shall be deemed to include disconnection of inlet and outlet pipes, welding works and GI fittings (if required) for connectioning and testing and nothing extra shall be admissible on this account.\n\n | | 6 | EACH\nJOB |
|---|
| 111 | 57 | M&L for repairs to old damaged foundation of water storage tank of capacity 27000 litres installed at stage-I including painting of entire exposed surface of iron frame work for staging with two coats of black synthetic enamell paint over a coat of red oxide primer complete all as directed,\nNote :- The rates quoted against this item shall be deemed to include any repair to steel frame work for staging alongwith connected items all as per manufacturer's instructions and nothing extra shall be admissible on this account.\nGeneral Note:-\nCredit schedule has been given separately under tender documents and shall be adjusted in general summary by the deptt. for arriving at net contract sum. \n | | 6 | EACH\nJOB |
|---|
| 112 | 58 | Brazing/welding of copper strip of size 20 x 3.15 /3 mm at each joint by overlapping of minimum 20mm of both strips which are laid as roof/down conductor on any height of building all as specified and as directed by Engr-in-Charge | | 200 | EACH WELD |
|---|
| 113 | 59 | Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws complete all as specified and directed including taking down old | | 20 | EACH |
|---|
| 114 | 60 | GI tube medium grade of bore 40 mm with all fittings and fixed complete to walls and ceiling or laid in trench or on roof for earthing, complete all as specified and directed by E ngr in charge including taking down old.\n | | 120 | RM |
|---|
| 115 | 61 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge. | | 180 | Cum |
|---|
| 116 | 62 | Returning filling in soils including spreding, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified. | | 160 | Cum |
|---|
| 117 | 63 | Removing surplus soil to a distance not exceeding 50 meter and sepositing where directed at a level not exceeding 1.5 meter above the starting point. | | 20 | Cum |
|---|
| 118 | 64 | Earth continuity conductor or main earthing lead 32x6 mm Copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed by Engr-in-charge\n\n | | 200 | RM |
|---|
| 119 | 65 | Earth continuity conductor or main earthing lead 32x6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed by Engr-in-charge\n | | 280 | RM |
|---|
| 120 | 66 | Earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15 mm buried directly in ground vertically at a depth not less than 4.50 metre below normal ground level with top edge of earth plate at a depth not less than 3.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed alternate layer of common salt and charcoal and a top layer of copper sulphate 150mm thick all as specified and as directed in drawing No CEAF/SK-60/2017 Dt 24.4.17 including bringing of mother soil from outside for filling holes, including Copper strip of size 20 x 3mm by means of nuts, bolts and check nuts, washers of copper up to main board/test point or as required including necessary excavation and earth work in any type of soil so as to achieve earth resistance below 3 Ohms including excavation of polypit chamber with polyplastic pit cover (cost of polypit chamber with polyplastic pit cover shall be deemed to be included in the rate quoted) complete all as specified and as directed by Engineer-in-Charge including dismantling of existing unserviceable earthing.\nNotes :\n(a) Copper strip beyond test point shall be measured and paid for separately.\n(b) Earthing resistance result shall be less than 3 ? .If the result comes more than 3 ? the contractor shall carry out the earthing at separate location/site given by the Engr-in-Charge after taking out of earth electrode without any extra cost to the deptt.\n(c) Test point terminal block shall be measured and paid for separately.\n(d) The contractor's quoted rates shall be deemed to include for dismantling/taking down of old unserviceable earthing of any type and making good the disturbed surfaces and nothing extra shall be admissible on this account.\n(e) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by the contractor without any extra cost to the Govt.\n(f) If mother soil is not available then mother soil wil be provided by contractor from outside source without any extra cost to the Govt. | | 20 | EACH\nSET |
|---|
| 121 | 67 | Overhauling and testing of 160 KVA DG set minimum upto 16 Hours continously as directed by Engr-in-Charge including supply and fixing in replacement of following items for 160 KVA DG set 01 No Make : Cummins :- Note : All work should be carried out in presence of user and MES Rep. | | | |
|---|
| 122 | 67.01 | Main bearing set | | 1 | EACH\n |
|---|
| 123 | 67.02 | Big end bearing set | | 1 | EACH\n |
|---|
| 124 | 67.03 | C R bearing set | | 1 | EACH\n |
|---|
| 125 | 67.04 | Piston assembly | | 6 | EACH |
|---|
| 126 | 67.05 | Valve seat inlet | | 6 | EACH\n |
|---|
| 127 | 67.06 | Valve seat exhaust | | 6 | EACH\n |
|---|
| 128 | 67.07 | Valve guides | | 12 | EACH\n |
|---|
| 129 | 67.08 | Valve inlet & exhaust | | 12 | EACH |
|---|
| 130 | 67.09 | Valve seats | | 12 | EACH\n |
|---|
| 131 | 67.1 | O' ring set | | 1 | EACH\nSET |
|---|
| 132 | 67.11 | Set of joints | | 1 | EACH\n |
|---|
| 133 | 67.12 | Ring set piston | | 6 | EACH |
|---|
| 134 | 67.13 | Liners assembly | | 6 | EACH\n |
|---|
| 135 | 67.14 | T C repair kit | | 1 | EACH\n |
|---|
| 136 | 67.15 | Relief valve assembly | | 1 | EACH |
|---|
| 137 | 67.16 | Oil seal rear | | 1 | EACH |
|---|
| 138 | 67.17 | Oil seal front | | 1 | EACH\n |
|---|
| 139 | 67.18 | Fuel filter | | 1 | EACH\n |
|---|
| 140 | 67.19 | Lubricating oil filter | | 1 | EACH\n |
|---|
| 141 | 67.2 | Centrifugal filter | | 1 | EACH |
|---|
| 142 | 67.21 | Air filter assembly | | 1 | EACH\n |
|---|
| 143 | 67.22 | Thrust washer | | 4 | EACH |
|---|
| 144 | 67.23 | Radiator assembly for 160 KVA DG set complete all as specified & directed | | 1 | EACH\n |
|---|
| 145 | 68 | Repair only following the items for 160 KVA DG set | | | |
|---|
| 146 | 68.1 | cylinder head repair | | 6 | EACH\n |
|---|
| 147 | 68.2 | pressure head testing | | 6 | EACH |
|---|
| 148 | 68.3 | crankshaft grinding | | 1 | EACH\n |
|---|
| 149 | 68.4 | fuel pump & injector repair | | 1 | EACH\n |
|---|
| 150 | 68.5 | connecting rod repair | | 6 | EACH\n |
|---|
| 151 | 68.6 | turbo charger repair | | 1 | EACH |
|---|
| 152 | 69 | Heavy duty porcelain/poly carbonate insulators of size 32 x 32mm to be fixed on wall/roof/pipe for laying of copper strip as roof/down conductor on building of height below 25 mtr including nuts & bolts of brass of appropriate size all as specified and as directed by Engr-in-Charge including taking down old unserviceable. | | 250 | EACH\n |
|---|