Operation And Comprehensive Maintenance Of Ems At Telephone Bhawan And Te Bldg Danapur Under Patna Ssa, patna and danapur-Bihar

Bharat Sanchar Nigam Limited-BSNL has published Operation And Comprehensive Maintenance Of Ems At Telephone Bhawan And Te Bldg Danapur Under Patna Ssa. Submission Date for this Tender is 08-04-2021. Tanks and Cylinders Tenders in patna and danapur Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

27508709
Operation And Comprehensive Maintenance Of Ems At Telephone Bhawan And Te Bldg Danapur Under Patna Ssa
Open Tender
Indian
Bihar
patna and danapur
08-04-2021

Tender Details

Operation And Comprehensive Maintenance Of Ems At Telephone Bhawan And Te Bldg Danapur Under Patna Ssa , Operation & Comprehensive Maintenance Of The Following Electro- Mechanical Services As Per Specifications And Details Of Services Etc . Attached . , A ) E . I . & Fans , B ) Pumps , C ) Compound-Lighting , D ) Lightning Conductor , E ) Sub-Station , F ) E . A . Set , G ) Fire Extinguishers . , H ) Split A/C Unit , Window A/C Units , Water Coolers . , I ) Package Ac Plant- , J ) Geysers . , K ) Lifts- Only Operation , Note :1]The Agency Shall Maintain The Defect Free Services & Shall Submit Report While Raising The Due Payments . , ( A ) I Year ==> , ( B ) Ii Year ==> , Servicing & Routine Maintenance ( B Check ) Of 2X200 Kva [M/S . Koel Make] Capacity Of Dg Set Complete With Cleaning Of Air Cleaner Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , Check & Reset Injector Pressure , Check & Reset Injector Pump Timing , Retighten Cylinder Head Nuts , Adjust Engine Valve Clearance , Replacement Of Radiator Water By Fresh Distilled Water With Addition Of Coolant Additive Concentrate , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Check Air Piping , Belt Tensions I/C Cleaning & Dedusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc & Actual Load Testing Of Dg Set After Servicing Etc As Directed . [B Check Once In 12 Months . Servicing Should Be Done From Authorised Dealer Only] , Supplying & Fixing Of Fully Charged 12 Volt , 180Ah Lead Acid Semi Maintenance Free Battery For Starting Of 200Kva Dg Set Complete With End Sockets Etc . As Reqd . Note-1 ) The Battery ( S ) Of Each Dg Set Shall Be Replaced Once During Currency Of Contract & Agency Shall Consider Rebate For Old Battery While Quoting Of Rates

Key Value

Document Fees
INR 590 /-
EMD
INR 64616.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Operation & Comprehensive Maintenance of EMS at Telephone Bhawan and TE Bldg Danapur under Patna SSA (Single Stage Bidding and Two Stage Opening).
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Operation & comprehensive Maintenance of the following Electro- mechanical services as per specifications and details of services etc. attached. BI01010001010000000000000515BI0100001113
2 1.02 a)  E.I. & Fans BI01010001010000000000000515BI0100001114
3 1.03 b)  Pumps BI01010001010000000000000515BI0100001115
4 1.04 c)  Compound-Lighting BI01010001010000000000000515BI0100001116
5 1.05 d)  Lightning conductor BI01010001010000000000000515BI0100001117
6 1.06 e)  Sub-station BI01010001010000000000000515BI0100001118
7 1.07 f)  E.A. Set BI01010001010000000000000515BI0100001119
8 1.08 g)   Fire Extinguishers. BI01010001010000000000000515BI0100001120
9 1.09 h)  Split A/C unit, Window A/C Units, Water Coolers. BI01010001010000000000000515BI0100001121
10 1.1 i) Package AC Plant- BI01010001010000000000000515BI0100001122
11 1.11 j) Geysers. BI01010001010000000000000515BI0100001123
12 1.12 k) Lifts- Only Operation BI01010001010000000000000515BI0100001124
13 1.13 NOTE :1]The Agency shall maintain the defect free services & shall submit report while raising the due payments . BI01010001010000000000000515BI0100001125
14 1.14 (a)  I Year ==> BI01010001010000000000000515BI0100001126 12 months
15 1.15 (b)  II Year ==> BI01010001010000000000000515BI0100001127 12 months
16 2 Servicing & Routine maintenance (B check) of 2x200 KVA [M/s. KOEL make] capacity of DG set complete with cleaning of Air cleaner element, Replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, Check & reset injector pressure, Check & reset injector pump timing, Retighten cylinder head nuts, Adjust engine valve clearance, Replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed. ["B" check once in 12 months. Servicing should be done from authorised dealer only] BI01010001010000000000000515BI0100001128 4 Job
17 3 Supplying & fixing of fully charged 12 volt,180AH lead acid Semi Maintenance Free battery for starting of 200KVA DG set complete with end sockets etc.as reqd.\nNOTE-\n1) The battery(s) of each DG set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates\n BI01010001010000000000000515BI0100001129 4 Nos