Rate Contract For Preventive/ Routine/ Breakdown Maintenance Of Equipments For 220/132/66Kv Grid Station Hiranagar, 132/66Kv Grid Station Samba, 132/33Kv Grid Stations Bari-Brahmana-Ii, Gangyal, Sidhra , Mahanpur And Siot Falling Under The Jurisdiction Of, TLMD-V Jurisdiction.-Jammu And Kashmir

Power Development Department has published Rate Contract For Preventive/ Routine/ Breakdown Maintenance Of Equipments For 220/132/66Kv Grid Station Hiranagar, 132/66Kv Grid Station Samba, 132/33Kv Grid Stations Bari-Brahmana-Ii, Gangyal, Sidhra , Mahanpur And Siot Falling Under The Jurisdiction Of. Submission Date for this Tender is 15-04-2021. Absorbents Tenders in TLMD-V Jurisdiction. Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

27489562
Rate Contract For Preventive/ Routine/ Breakdown Maintenance Of Equipments For 220/132/66Kv Grid Station Hiranagar, 132/66Kv Grid Station Samba, 132/33Kv Grid Stations Bari-Brahmana-Ii, Gangyal, Sidhra , Mahanpur And Siot Falling Under The Jurisdiction Of
National Competitive Bid
Indian
Jammu And Kashmir
TLMD-V Jurisdiction.
15-04-2021

Tender Details

Rate Contract For Preventive / Routine / Breakdown Maintenance Of Equipments For 220 / 132 / 66Kv Grid Station Hiranagar, 132 / 66Kv Grid Station Samba, 132 / 33Kv Grid Stations Bari-Brahmana-Ii, Gangyal, Sidhra , Mahanpur And Siot Falling Under The Jurisdiction Of Tlmd-V Jkptcl, Jammu For The Year 2021-22-1 Auto-Transformers / Power Transformers / Auxillary Transformers:- Na ) Checking Of Auto Starting Of Fans, External Cleaning Of Radiators, Oil Pumps Ofaf / Onaf, Cleaning And Checking Of Marshalling Boxes Of Transformer / Reactor And Oltc, ( Ii ) Tightening Of Terminations, Checking Of Oltc Driving Mechanism, Electrical Checking / Testing Of Pressure Relief Device, Buchholz Relay, Oltc Surge Relay / Checking Of Alarm / Trip And Checking / Replacement Of The Gaskets Of The Terminal Box, Checking / Tightning Of Earthing Connections, Checking Of Earth Resistance Of Neutral, Replacement Of Silca Gel Of Breathers And Oil Topping Of Transformers And Tightning Of Bushing Clamps On Hv / Iv / Lv Sides Of 4X66.67Mva, 4X40 Mva, Auto Transformers And 20Mva To 50Mva Power Transformers Including Tandelta Testing Of Bushing / Winding & Dga / Bdv / Ppm Testing Of Transformer Oil.Other Tests On The Transformer Like Ratio Test, Ir Value / Magnetic Balance / Short Circuit Test Etc. Checking Of Space Heater And Illumination 2 66.67 Mva 1 Ø, 220 / 132 Kv 3 40Mva 1 Ø, 220 / 132 Kv 4 50 Mva 132 / 66 Kv 5 20 Mva 132 / 66 Kv 6 50 Mva 132 / 66 Kv 7 50Mva, 132 / 33Kv 8 20 Mva 132 / 33 Kv 9 1000 Kva, 66 / 11 Kv 10 500 Kva, 66 / 11 Kv 11 250Kva, 33 / 0.440Kv 12 250Kva, 11 / 0.440Kv 13 Draning / De-Sludging Of Transformer Oil Of Transformers 14 Filling Of Oil, Filitration And Dehydration Of Transformer Including Installation Of Vacume Pump To Be Provided By The Department. 15 Reparing Of Cooloing Fans Of Transformers Including Replacement Of Damaged Winding, Bearing, Mcbs, Contactors, Wiring Of Control Circuitsetc. 16 Lifting Of Top Lid Of Power Transformer For Complete Physical Inspection & Replacement Of Gaskets. 17 Replacement Of Damaged Core Bolts / Earthning Strip Etc. 18 Testing Of Transformer:- 19 Testing Of Transformer:- Tandelta Testing Of Bushing / Winding & Bdv Testing Of Transformer Oil.Other Tests On The Transformer Like Ratio Test, Ir Value / Magnetic Balance / Short Circuit Test Etc, Kits For Testing Shall Be Provided By The Department. 20 Dga And Ppm Of Transformer From Accredted Laboratories. 21 Replacement Of Damaged / Outlived Bushing Having High N Tan Delta Including Crane / Mechanical Equipment If Required. 22 220 Kv Bushing 23 132 Kv Bushing 24 66 Kv Bushing 25 33 Kv Bushing 26 11 Kv Bushing 27 Overhauling Of Circuit Breaker :- Vcb / Mocb / Sf6 / Acb Nchecking Of Oil / Gas Pressure Drop During Duty Cycle Operation Check, Checking Of Auto-Starting / Stopping Of Oil Pump, Pressure Switch Setting, Etc, Checking Of Healthiness Of Accumulator By Checking The Pre-Charging Pressure When Building Up Pressure From Zero, Checking Of Operation Of Safety Valve, Checking Of Air Compressor, Cleaning Of Breaker Units, Checking Of Protection Equipments And Replacement Of Defective Ones, I.E., Complete Inspection And Testing Of Sf6 / Vcb / Mocb / Acb Type Circuit Breakers Inclusive Of Operating Mechanism.Checking Of Driving Mechanism, Trip / Closing Circuits / Checking And Repairing Of Spring Charge Motor And Checking Of Tripping And Closing Coils.Checking Of Equipment Earthing And Strucure Earthing. Maintaning Gas Levels, Venting Of Circuit Breakers, Replacement Of O-Rings , Gas Kits Including Circuit Breaker Anylysis By Circuit Breaker Analyser.Checking Of Space Heater And Illumination.Required As Per Schedule Of Maintenance 28 220Kv Sf6 Breaker 29 132Kv Sf6 Breaker 30 66 Kv Mocb / Sf6 31 33 Kv Vcb 32 Replacement Of Damaged Pole Of The Circuit Breaker Including Carriage Of The Equipment From Divisional Store To The Site Of Work And Back Carriage Of The Damaged Equipment To The Divisional Store 33 220Kv Sf6 Breaker 34 132Kv Sf6 Breaker 35 66 Kv Mocb / Sf6 36 33 Kv Vcb 37 Cvts / Cts / Pts :- Nvisual Checking Of Earthing Hfpoint ( In Case It Is Not Being Used For Plcc, Checking Of Any Breakage Or Cracks In Porclean Insulator, Cleaning Of Cvt Capacitor Stacks And Tightness Of Terminal Connections, Checking And Tightness Of All Connections Including Earth Connections.Checking Of Healthiness Of Gaskets, Checking Of Neutral Earthing In Cvt, Healthiness Of All Gaskets And Oil Level And Its Topping.Measurement Of Ir Value And Tightening Of All Connections And Droppers.Primary Injection Test Of Ct / Pt, Tan Delta, Knee Point Value, Burden Etc. 38 220 Kv 39 132 Kv 40 66 Kv 41 33 Kv 42 Replacement Of Damaged Ct / Pt Including Carriage Of The Equipment From Divisional Store To The Site Of Work And Back Carriage Of The Damaged Equiupment To The Divisional Store. 43 220 Kv 44 132 Kv 45 66 Kv 46 33 Kv 47 Surge Arrestors :- Nchecking Of Leakage Current ( Third Harmonic Resistive Current ) , Testing Of Counters And Leakage Current Meters, Cleaning Of Insulators, Checking Of Earth Connections Between Surge Arrester, Surge Monitor And Earth, Checking Of Leakage Current After Cleaning Of Porcelain Surface, Cleaning Of La Insulators. Measurement Of Ir Value And Tightening Of Droppers. 48 220 Kv 49 132 Kv 50 66 Kv 51 33 Kv 52 Replacement Of Damaged Surge Arrestor Including Carriage Of The Equipment From Divisional Store To The Site Of Work And Back Carriage Of The Damaged Equiupment To The Divisional Store. 53 220 Kv 54 132 Kv 55 66 Kv 56 33 Kv 57 Isolators :- Nmaintenance Of Linkages Including Transmission Gears, Stopper Bolts. Cleaning Of Auxiliary Switch Contacts And Greasing With Silca Grease, Cleaning Of Support Insulators, Termination Contacts, Checking Of Elecctrical / Mechanical Interlocks With E / S And Cb, Mounting Bolts, Alignment, Nuts, Pins, Space Heater, Illumination, Healthiness Of Gaskets, Auxiliary Contacts, Alignment Of Earthing Blades, Operation Of Earth Switch, Almunium / Copper Flexible Conductor, Earth Connections Of Structures And Mb. Lubrication Of Operating Mechanism, Hinges Lock Joints, Levers, Bearings, Main Contacts, Cleaning Of Post Insulators, Tightening Of Clamps. 58 220 Kv 59 132 Kv 60 66 Kv 61 33 Kv 62 Replacement Of Damaged Isolators Including Carriage Of The Equipment From Divisional Store To The Site Of Work And Back Carriage Of The Damaged Equiupment To The Divisional Store. 63 220 Kv 64 132 Kv 65 66 Kv 66 33 Kv 67 Reparing Of Three Phase Motors Of Isolators Including Replacement Of Damaged Winding And Bearing. 68 Droppers / Jumpers Nreplacement Of Damaged / Burnt Droppers Or Jumpers Of Isolators / Breakers / Transformers / Ct / Pt / La Etc. N220 / 132 / 66 / 33 Kv Yard. 69 Clamps: Nreplacement Of Damaged / Burnt Pg / Pad / T / Ct / Bushing Clamp Etc 70 Post Insulators :- Nchecking Of Insulators For Cracks And Cleaning Of Insulators And Its Replacemnt. 71 220 Kv 72 132 Kv 73 66 Kv 74 33 Kv 75 Illumination System :- Nchecking Of Healthiness Of Fittings In Station Buildings, Outdoor Switch Yard, Tightening Of Terminals, Etc. 76 Replacement Of 200 Watt Led In The Outdoor Switch Yard 77 Replacement Of Led / Cfl Along With Fitting In The Control Room / Division Building / Office Complex 78 Battery Bank: Nchecking And Cleaning Of Battery Cell Terminals, Application Of Patrolum Gelly, If Required, Conduction Of Battery Impendence Test And Discharge Test Checking Voltage Temperature, Current, Sp. Gravity Of Individual Cells As Well As Terminals Voltage, Battery Dischrge Testing Etc.Checking Of Positive / Negative Earth Fault Of Dc.Terminal Tightening. 79 Battery Charger :- Nchecking Of Control Cards, Measurement Of Test Point Voltage Values, Testing Of Dc Earthfault And U / V Relays, Ir Measurement Of Charger Transformer, Checking Of Earthing Etc. Checking Of Charger Panel / Dcdb For Electrical Connections, Cleanliness Etc. 80 Protection System :- Nchecking Of Relays And Application Of Ccl4 For Cleaning, Replacement Of Worn Out / Defunct Relays, Checking And Replacement Of Control Wiring, If Required, Primery & Secondery Injection Testing, Software Settings Etc. 81 Cleaning Of Cable Trenches / Ducts Including Of Dressing Of Cables, Trays, Racks , Repair Of Damaged Duct Covers Etc 82 Main 83 Sub Main 84 T-Off 85 Gantry Columns And Beams :- Tightening Of All Nuts / Bolts And Providing Of Missing Nuts / Bolts And Replacement Of Damaged Members. 86 220 Kv 87 132 Kv 88 66 Kv 89 33 Kv 90 L.T. Transformer :- Ntesting Of Oil Bdv, Ir Measurement, Testing / Checking Of Oti, Wti And Buchholz ( If Provided, Checking Of Healthiness Of Pressure Relief Diaphragm, Checking Healthiness Of Buchholz Relay, Checking Tightness Of Earthing Connections N 91 L.T Pannel: Ncleaning Of Panels, Bus Bar Insulators Etc. Relays Testing, Tightning Of All Electrical Connections, Checking Of Indicating Meters , Check For Change-Over Facility, If Provided, Check Operation / Indications In Off Load Condition Of Mccb, 92 Earthing Mat :- Nmeasurment Of Earth Resistivity, Checking Of Electrical Continuity Of Equipment Earthings, Tightening Of Earthing Connectors, Removal Of Rust From Bolted Earth Connectors And Tightening And Additional Earthing Wherever Required. N220 / 132 / 66 / 33 Kv 93 Dc Distribution Board :- Nchecking Of Connections, Wiring, Replacement Of Wiring If Needed And Checking Of Healthiness Of All D / C And Dc Circuits Of 33 / 66 / 132 / 220 Kv Yards 94 Ac Distribution Board :- Nchecking Of Connections, Wiring, Replacement Of Wiring If Needed, Fuses, Mcb, Bus Bar Ct, Relays, Mfm, Lt Switchs Etc And Checking Of Healthiness Of All Connections And Ac Circuits Of 33 / 66 / 132 / 220 Kv Yards. 95 Control Cables: Replacement Of Damaged / Outlived / Burnt Control Cables Of Different Cores Including Proper Ferruling, Thimbling And Tagging And Finally With All Appropriate Connections Including Lifting Of Duct Covers And Placing Them Back. 96 Below 10 Core 97 Above 10 Core 98 Marshelling Koisk:- Nchecking Of All Terminal Blocks, Space Heaters, Light Illumination, Checking Of All Connnections And Its Cleaning. Fixing Of Cable Glands Earthing And Checking Of All Other Electrical Accessories . N 99 Capacitor Banks :- Nchecking / Tightening Of Capacitor Cells Terminals, Reactor And Checking Its Wiring Connection And Its Control Circuit.Etc 100 Bus Bar :- Nreplacement Of Damaged Acsr Conductor Along With Its Fittings. N N 101 220 Kv Yard 102 132 Kv Yard 103 66 Kv Yard 104 33 Kv Yard 105 Automatic Voltage Regulator:- Nchecking And Tightening Of Connections, Auto Control Unit, Oil And Its Overhaulling 106 Diesel Generator Set: N Maintenance And Checking Of Its Operation. 107 Deweeding Of Switch Yard 108 Painting Of Outdoor Equipments ( Transformers, Mks, Ct / Pt / Cvt, Protection Wall, Circuit Breaker, Isolatores, Poles Etc. 109 Ac Units: Checking And Servicing Of Installed Ac Unit Inside Control Room ( 1- 3 Ton ) / Office Building / Division Building / Residential Quarters Etc 110 White-Washing Of Control Room / Residencial Quarters At Grid Stations, Guest House And Divisional Office Building 111 Upkeep Of Sanitary Installed In The Control Room / Office Building / Division Building / Residential Quaters / Toilets And Replacement Of Any Damaged Item If Required. 112 Upkeep Of Electrical Accessories Installed In The Control Room / Office Building / Division Building / Residential Quarters And Replacement Of Any Damaged Item If Required. 113 Providing Of Skilled / Semi Skilled / Un Skilled Labour For The Works Which Are Not Coverd From S.No. 1 To 29 114 Skilled Labour 115 Semi- Skilled 116 Un Skilled 117 Store Handling 118 Unloading Of Material In The Divisional Store 119 220 / 132 / 66 / 33 Kv Breaker 120 220 / 132 / 66 / 33 Kv Cts 121 220 / 132 / 66 / 33 Kv Pts 122 220 / 132 / 66 / 33 Kv Las 123 220 / 132 / 66 / 33 Kv Isolator 124 Carriage Of Material From Unloading Site To Stacking Site And Stacking The Material Properly 125 220 / 132 / 66 / 33 Kv Breaker 126 220 / 132 / 66 / 33 Kv Cts 127 220 / 132 / 66 / 33 Kv Pts 128 220 / 132 / 66 / 33 Kv Las 129 220 / 132 / 66 / 33 Kv Isolator 130 Shifting Of Material To Make The Space For Adjustment Of Material 131 220 / 132 / 66 / 33 Kv Breaker 132 220 / 132 / 66 / 33 Kv Cts 133 220 / 132 / 66 / 33 Kv Pts 134 220 / 132 / 66 / 33 Kv Las 135 220 / 132 / 66 / 33 Kv Isolator 136 Carriage Of Material From Divisional Store To Loading Site 137 220 / 132 / 66 / 33 Kv Breaker 138 220 / 132 / 66 / 33 Kv Cts 139 220 / 132 / 66 / 33 Kv Pts 140 220 / 132 / 66 / 33 Kv Las 141 220 / 132 / 66 / 33 Kv Isolator 142 Loading Of Material In The Vechile. 143 220 / 132 / 66 / 33 Kv Breaker 144 220 / 132 / 66 / 33 Kv Cts 145 220 / 132 / 66 / 33 Kv Pts 146 220 / 132 / 66 / 33 Kv Las 147 220 / 132 / 66 / 33 Kv Isolator 148 Surface Density / Bush Cutting / Levelling Of Store Premises. 149 Disposal Of Material / Mulba From The Store To Outside The Store Premises 150 Cleaning Of Drainage / Front Area Of Store / Guest House During Monsoon / Rainy Season 151 Guest House-I 152 Washing Of Bed Sheets / Curtains. 153 Repair Of Switch Boards / Electrical Circuits Including Replacement Of Electrical Components.

Key Value

Document Fees
INR 2000 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: RATE CONTRACT for Preventive/ Routine/ Breakdown Maintenance of Equipments for 220/132/66KV Grid station Hiranagar, 132/66KV Grid Station Samba, 132/33KV Grid Stations Bari-Brahmana-II, Gangyal, Sidhra , Mahanpur and Siot falling under the jurisdiction of TLMD-V JKPTCL, Jammu for the year 2021-22.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Auto-Transformers/Power Transformers /Auxillary Transformers:- \nA) Checking of Auto starting of fans, External cleaning of radiators,oil pumps OFAF/ONAF,Cleaning and checking of marshalling boxes of transformer/reactor and OLTC, (ii) Tightening of terminations, Checking of OLTC driving mechanism, Electrical checking/ testing of pressure relief device, Buchholz relay, OLTC surge relay/ checking of alarm/ trip and checking/ replacement of the gaskets of the terminal box, Checking / Tightning of earthing connections, Checking of earth resistance of Neutral, Replacement of Silca Gel of breathers and oil topping of transformers and tightning of bushing clamps on HV/IV/LV sides of 4X66.67mva, 4X40 mva, auto transformers and 20MVA to 50MVA power transformers including tandelta testing of bushing/ winding & DGA/ BDV/PPM testing of transformer oil.other tests on the transformer like ratio test, IR value/ Magnetic balance/ short circuit test etc. Checking of space heater and illumination
2 1.01 66.67 MVA 1 Ø, 220/132 KV item1 1 No.
3 1.02 40MVA 1 Ø, 220/132 KV item2 1 No.
4 1.03 50 MVA 132/66 KV item3 1 No.
5 1.04 20 MVA 132/66 KV item4 1 No.
6 1.05 50 MVA 132/66 KV item5 1 No.
7 1.06 50MVA, 132/33KV item6 1 No.
8 1.07 20 MVA 132/33 KV item7 1 No.
9 1.08 1000 KVA, 66/11 KV item8 1 No.
10 1.09 500 KVA, 66/11 KV item9 1 No.
11 1.1 250KVA,33/0.440KV item10 1 No.
12 1.11 250KVA,11/0.440KV item11 1 No.
13 1.12 Draning/ De-sludging of transformer oil of transformers item12 1 per KL
14 1.13 Filling of oil, filitration and dehydration of transformer including installation of vacume pump to be provided by the Department. item13 1 per KL
15 1.14 Reparing of cooloing fans of transformers including replacement of damaged winding, bearing,MCBs,Contactors, wiring of control circuitsetc. item14 1 No.
16 1.15 Lifting of top lid of power transformer for complete physical inspection & replacement of gaskets. item15 1 No.
17 1.16 Replacement of damaged core bolts/Earthning strip etc. item16 1 No.
18 1.17 Testing of Transformer:-
19 1.18 Testing of Transformer:- tandelta testing of bushing/ winding & BDV testing of transformer oil.other tests on the transformer like ratio test, IR value/ Magnetic balance/ short circuit test etc, kits for testing shall be provided by the department. item17 1 No.
20 1.19 DGA and PPM of Transformer from accredted laboratories. item18 1 sample
21 1.2 Replacement of damaged/outlived bushing having high\n tan delta including crane/ mechanical equipment if required.
22 1.21 220 KV Bushing item19 1 No.
23 1.22 132 KV Bushing item20 1 No.
24 1.23 66 KV Bushing item21 1 No.
25 1.24 33 KV Bushing item22 1 No.
26 1.25 11 KV Bushing item23 1 No.
27 2 Overhauling of Circuit Breaker :- VCB/MOCB/SF6/ACB\nChecking of oil/gas pressure drop during duty cycle operation check, Checking of auto-starting / stopping of oil pump,pressure switch setting,etc, Checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, Checking of operation of safety valve, checking of air compressor, Cleaning of breaker units, checking of protection equipments and replacement of defective ones, i.e., complete inspection and testing of SF6/VCB/MOCB/ACB type circuit breakers inclusive of operating mechanism.Checking of driving mechanism, trip/closing circuits/ checking and repairing of spring charge motor and checking of tripping and closing coils.checking of equipment earthing and strucure earthing. Maintaning gas levels, venting of circuit breakers, replacement of o-rings , gas kits including circuit breaker anylysis by Circuit breaker analyser.Checking of space heater and illumination.Required as per schedule of maintenance
28 2.01 220KV SF6 Breaker item24 1 No.
29 2.02 132KV SF6 Breaker item25 1 No.
30 2.03 66 KV MOCB/SF6 item26 1 No.
31 2.04 33 KV VCB item27 1 No.
32 2.05 Replacement of damaged pole of the circuit breaker including carriage of the equipment from divisional store to the site of work and back carriage of the damaged equipment to the divisional store
33 2.06 220KV SF6 Breaker item28 1 No.
34 2.07 132KV SF6 Breaker item29 1 No.
35 2.08 66 KV MOCB/SF6 item30 1 No.
36 2.09 33 KV VCB item31 1 No.
37 3 CVT's /CT's /PT's :- \nVisual checking of earthing HFpoint (in case it is not being used for PLCC,Checking of any breakage or cracks in porclean insulator, Cleaning of CVT capacitor stacks and tightness of terminal connections,Checking and tightness of all connections including earth connections.Checking of healthiness of gaskets, Checking of neutral earthing in CVT, healthiness of all gaskets and oil level and its topping.Measurement of IR value and tightening of all connections and droppers.Primary injection test of CT/PT, Tan delta,knee point value, burden etc.
38 3.01 220 KV item32 1 No.
39 3.02 132 KV item33 1 No.
40 3.03 66 KV item34 1 No.
41 3.04 33 KV item35 1 No.
42 3.05 Replacement of damaged CT/PT including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.
43 3.06 220 KV item36 1 No.
44 3.07 132 KV item37 1 No.
45 3.08 66 KV item38 1 No.
46 3.09 33 KV item39 1 No.
47 4 Surge Arrestors :-\nChecking of leakage current(third harmonic resistive current), Testing of counters and leakage current meters, Cleaning of insulators, Checking of earth connections between surge arrester,surge monitor and earth, Checking of leakage current after cleaning of porcelain surface, cleaning of LA insulators. Measurement of IR value and tightening of droppers.
48 4.01 220 kV item40 1 No.
49 4.02 132 kV item41 1 No.
50 4.03 66 kV item42 1 No.
51 4.04 33 KV item43 1 No.
52 4.05 Replacement of damaged Surge Arrestor including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.
53 4.06 220 kV item44 1 No.
54 4.07 132 kV item45 1 No.
55 4.08 66 kV item46 1 No.
56 4.09 33 KV item47 1 No.
57 5 Isolators :- \nMaintenance of linkages including transmission gears, stopper bolts. Cleaning of auxiliary switch contacts and greasing with silca grease, cleaning of support insulators, termination contacts, checking of elecctrical / mechanical interlocks with E/S and CB, mounting bolts, alignment, nuts, pins, space heater, illumination, healthiness of gaskets, auxiliary contacts, alignment of earthing blades, operation of earth switch, almunium / copper flexible conductor, earth connections of structures and MB. lubrication of operating mechanism, hinges lock joints, levers, bearings, main contacts, cleaning of post insulators, tightening of clamps.
58 5.01 220 kV item48 1 No.
59 5.02 132 kV item49 1 No.
60 5.03 66 kV item50 1 No.
61 5.04 33 KV item51 1 No.
62 5.05 Replacement of damaged Isolators including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.
63 5.06 220 kV item52 1 No.
64 5.07 132 kV item53 1 No.
65 5.08 66 kV item54 1 No.
66 5.09 33 KV item55 1 No.
67 5.1 Reparing of Three phase motors of isolators including replacement of damaged winding and bearing. item56 1 No.
68 6 Droppers/Jumpers\nReplacement of damaged / burnt droppers or jumpers of isolators/ breakers/transformers /CT/PT /LA etc.\n220/132/66/33 KV Yard. item57 1 No.
69 7 Clamps:\nReplacement of damaged/burnt PG/ PAD/T/CT/Bushing clamp etc item58 1 No.
70 8 Post Insulators :- \nChecking of insulators for cracks and cleaning of insulators and its replacemnt.
71 8.01 220 kV item59 1 set of 3
72 8.02 132 kV item60 1 set of 3
73 8.03 66 kV item61 1 set of 3
74 8.04 33 KV item62 1 set of 3
75 9 Illumination System :- \nChecking of healthiness of fittings in station buildings, outdoor switch yard, Tightening of terminals, etc. item63 1 job
76 9.01 Replacement of 200 watt LED in the outdoor switch yard item64 1 No.
77 9.02 Replacement of LED/CFL along with fitting in the control room/ division building/office complex item65 1 No.
78 10 Battery Bank:\nChecking and cleaning of battery cell terminals, application of patrolum gelly, if required, conduction of battery impendence test and discharge test checking voltage temperature, current, sp. Gravity of individual cells as well as terminals voltage, battery dischrge testing etc.Checking of positive/Negative earth fault of dc.Terminal tightening. item66 1 per cell
79 11 Battery Charger :- \nChecking of control cards, measurement of test point voltage values, testing of DC earthfault and U/V relays, IR measurement of charger transformer, checking of earthing etc. Checking of charger panel / DCDB for electrical connections, cleanliness etc. item67 1 Job
80 12 Protection System :- \nChecking of relays and application of CCl4 for cleaning, replacement of worn out / defunct relays, checking and replacement of control wiring, if required, primery & secondery injection testing,software settings etc. item68 1 No.
81 13 Cleaning of cable trenches/ ducts including of dressing of cables, trays, racks , repair of damaged duct covers etc
82 13.01 Main item69 1 RM
83 13.02 sub main item70 1 RM
84 13.03 T-off item71 1 RM
85 14 Gantry Columns and Beams :- Tightening of all nuts / bolts and providing of missing nuts / bolts and replacement of damaged members.
86 14.01 220 kV item72 1 bay
87 14.02 132 kV item73 1 bay
88 14.03 66 kV item74 1 bay
89 14.04 33 KV item75 1 bay
90 15 L.T. Transformer :-\nTesting of oil BDV, IR measurement, Testing /checking of OTI,WTI and Buchholz (if provided, Checking of healthiness of Pressure relief diaphragm, Checking healthiness of Buchholz relay, Checking tightness of earthing connections\n item76 1 job
91 15.01 L.T Pannel:\nCleaning of panels,bus bar insulators etc. Relays Testing, Tightning of all electrical connections,Checking of indicating meters ,Check for change-over facility, if provided,Check operation /indications in OFF Load condition of MCCB, item77 1 job
92 16 Earthing Mat :- \nMeasurment of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening and additional earthing wherever required.\n220/132/66/33 kV item78 1 job
93 17 DC Distribution Board :-\nChecking of connections, wiring, replacement of wiring if needed and checking of healthiness of all D/C and dc circuits of 33/66/132/220 Kv yards item79 1 job
94 18 AC Distribution Board :-\nChecking of connections, wiring, replacement of wiring if needed,fuses,MCB,bus bar CT, relays,MFM,LT switchs etc and checking of healthiness of all connections and AC circuits of 33/66/132/220 kv yards. item80 1 job
95 19 Control Cables: Replacement of damaged/outlived/burnt control cables of different cores including proper ferruling, thimbling and tagging and finally with all appropriate connections including lifting of duct covers and placing them back.
96 19.01 below 10 core item81 1 per mtr.
97 19.02 above 10 core item82 1 per mtr.
98 20 Marshelling koisk:-\nchecking of all Terminal blocks, space heaters, light illumination, checking of all connnections and its cleaning. Fixing of cable glands earthing and checking of all other electrical accessories .\n item83 1 No.
99 21 Capacitor Banks :-\nChecking/ tightening of capacitor cells terminals, reactor and checking its wiring connection and its control circuit.etc item84 1 job
100 22 BUS BAR :-\nReplacement of damaged ACSR Conductor along with its fittings.\n\n
101 22.01 220 kv yard item86 1 per string
102 22.02 132 kv yard item87 1 per string
103 22.03 66 kv yard item88 1 per string
104 22.04 33 kv yard item89 1 per string
105 23 Automatic voltage regulator:-\nchecking and tightening of connections, auto control unit, oil and its overhaulling item90 1 job
106 24 Diesel Generator set: \n Maintenance and checking of its operation. item91 1 job
107 25 Deweeding of switch yard item92 1 Sqmt
108 26 Painting of outdoor equipments (Transformers, MK's, CT/PT/CVT, Protection wall, Circuit breaker, isolatores, poles etc. item93 1 Sqmt
109 27 AC Units: Checking and Servicing of Installed AC unit inside control room (1- 3 Ton) /office building/division building/residential quarters etc item94 1 No
110 28 White-Washing of Control Room/Residencial Quarters at Grid Stations, Guest house and Divisional Office building item95 1 Sqmt
111 29 Upkeep of Sanitary installed in the control room/ office building/division building/residential quaters/Toilets and replacement of any damaged item if required. item96 1 point
112 29.01 Upkeep of electrical accessories installed in the control room/ office building/division building/residential quarters and replacement of any damaged item if required. item97 1 point
113 30 Providing of skilled/ semi skilled/ un skilled labour for the works which are not coverd from s.no. 1 to 29
114 30.01 skilled labour item98 1 day
115 30.02 semi- skilled item99 1 day
116 30.03 un skilled item100 1 day
117 31 Store Handling
118 31.01 Unloading of Material in the Divisional store
119 31.02 220/132/66/33 KV Breaker item101 1 No.
120 31.03 220/132/66/33 KV CT's item102 1 set of 3
121 31.04 220/132/66/33 KV PT's item103 1 set of 3
122 31.05 220/132/66/33 KV LA's item104 1 set of 3
123 31.06 220/132/66/33 KV Isolator item105 1 No.
124 31.07 Carriage of Material from Unloading site to stacking site and stacking the material properly
125 31.08 220/132/66/33 KV Breaker item106 1 No.
126 31.09 220/132/66/33 KV CT's item107 1 set of 3
127 31.1 220/132/66/33 KV PT's item108 1 set of 3
128 31.11 220/132/66/33 KV LA's item109 1 set of 3
129 31.12 220/132/66/33 KV Isolator item110 1 No.
130 31.13 Shifting of material to make the space for adjustment of material
131 31.14 220/132/66/33 KV Breaker item111 1 No.
132 31.15 220/132/66/33 KV CT's item112 1 set of 3
133 31.16 220/132/66/33 KV PT's item113 1 set of 3
134 31.17 220/132/66/33 KV LA's item114 1 set of 3
135 31.18 220/132/66/33 KV Isolator item115 1 No.
136 31.19 Carriage of material from divisional store to loading site
137 31.2 220/132/66/33 KV Breaker item116 1 No.
138 31.21 220/132/66/33 KV CT's item117 1 set of 3
139 31.22 220/132/66/33 KV PT's item118 1 set of 3
140 31.23 220/132/66/33 KV LA's item119 1 set of 3
141 31.24 220/132/66/33 KV Isolator item120 1 No.
142 31.25 Loading of material in the vechile.
143 31.26 220/132/66/33 KV Breaker item121 1 No.
144 31.27 220/132/66/33 KV CT's item122 1 set of 3
145 31.28 220/132/66/33 KV PT's item123 1 set of 3
146 31.29 220/132/66/33 KV LA's item124 1 set of 3
147 31.3 220/132/66/33 KV Isolator item125 1 No.
148 31.31 Surface density/bush cutting/levelling of store premises. item126 1 Sqmt
149 31.32 Disposal of material/Mulba from the store to outside the store premises item127 1 kg
150 31.33 Cleaning of Drainage/front area of store/Guest house during Monsoon/Rainy season item128 1 Sqmt
151 32 Guest House-I
152 32.01 Washing of bed sheets/Curtains. item129 1 No.
153 32.02 Repair of switch boards/electrical circuits including replacement of electrical components. item130 1 No.
Disclaimer :