}

Special Repairs To Kiran Store House Bldg No P18 At Mo Goa Under Ge Gomantak Vasco, CWE NAVY VASCO-Goa

Military Engineer Services-MES has published Special Repairs To Kiran Store House Bldg No P18 At Mo Goa Under Ge Gomantak Vasco. Submission Date for this Tender is 19-04-2021. Building Repair Tenders in CWE NAVY VASCO Goa. Bidders can get complete Tender details and download the document.




Tender Notice

27484851
Corrigendum : Special Repairs To Kiran Store House Bldg No P18 At Mo Goa Under Ge Gomantak Vasco
Open Tender
Indian
Goa
CWE NAVY VASCO
19-04-2021

Tender Details

Special Repairs To Kiran Store House Bldg No P18 At Mo Goa Under Ge Gomantak Vasco-1 Old Ceiling Boards Of Any Description, Pattern And Size 2 Iron Scrap 3 Old Pcc Block / B’ Bricks / Stones In Any Condition 4 Old Plain / Corrugatedsemi Corrugated Roofing Sheet In Any Condition 5 Old U / S Point Wiring Complete Light / Fan / Socket 6 Old U / S Piano Modular Type Switch 7 Old U / S Switch Socket Outlet Any Amps 8 Old U / S Celing Rose 9 Old U / S Regulator 10 Old U / S Mcb 11 Oidu / Smcb|Db? 12 Old Uls Recess Mounted Light 13 Old Unsv Sub Main Wiring Any Size 14 Old U / S Earthing Material

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Apr-2021 DATECORRI Date 19-04-2021
2 07-Apr-2021 BOQCORRI Other 19-04-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 95000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK :- SPECIAL REPAIRS TO KIRAN STORE HOUSE (BLDG NO. P-18) AT MO GOA UNDER GE GOMANTAK VASCO
Sl. No. Item Description Item Code / Make Quantity Units
1 0.05 Schedule 'A' -Part I (B/R Portion)
2 1 M & L for chipping removing carefully concrete work by low impact hammer, breaker without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as specified and as directed. \nNote : Hard concrete should not be removed by force. 250 Sqm
3 2 M&L for Clean existing reinforcement with wire/ rotary wire brush making the surfaces free from loose material dirt etc complete, Applying two coats of alkaline rust converting primer confirming to ASTM-B-117 on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating complete all as specified and as directed. 250 Sqm
4 3 M&L for Carry out application of 'Bi-polar migratory corrosion on concrete surface complete all as specified and as directed. 250 Sqm
5 4 M&L for providing and applying structural grade prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all as specified and as directed. 250 Sqm
6 5 M&L for Building up the profile of structural members by using latex additives modified air cured mortar system (Polymer modified mortar) (1:5:15 =1-MONOBOND, 5-Cement, 15-Sand) in damaged areas in 20mm thickness including leveling profiling etc complete all as specified and as directed. 200 Sqm
7 6 M&L for Building up the profile of structural members by using latex additives modified air cured mortar system (Polymer modified mortar) (1:5:15 =1-MONOBOND, 5-Cement, 15-Sand) in damaged areas in 40mm thickness in two layers (Each layer 20 mm thick) including leveling profiling etc complete all as specified and as directed. 50 Sqm
8 7 Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter and applying protective coating complete all as specified and as directed. 100 Kg
9 8 M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep hole in structural members at the interval of 500mm center to center in staggered manner or as directed by Engineer-in-Charge in RCC structural element. Work shall be carried out as under :-\n(i) Cleaning of holes - Clean the holes by air blower prior to fixing nozzles.\n(ii) Fixing of nozzles - Insert 12mm dia Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the hole by applying thixotropic epoxy putty to ensure complete sealing . Cure the system for min 12 hrs.\n(iii) Cutting of nozzles - Cut the nozzles by chiser after completion of grouting without damaging structural elements. 700 Each
10 9 M&L for Injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of material.\n Mixing of materials :- Mixing of material components (part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting maintain the pressure at exit (0.5 to 1.0 kg/cm2) by monitoring pressure gauge at exit. Grout the material through prefixed nozzles in the structural element @ 100ml per nozzle. Repeat the process for all the nozzles (Beam and columns) complete all as specified and as directed. 700 Each
11 10 M&L for jacketing around columns with Micro concrete (Molith-MC) M-40 including all lifts, shuttering, drilling holes and fixing shear Anchor as per specification complete all as specified and as directed. \nNotes:- \n1.Reinforcement shall be measured and paid separately. 2.Rates including jacketing, formwork and Micro concrete 1 Cum
12 11 M&L for cutting out cracks to 'V'section not exceeding 5mm in existing roofs walls by using machine cleaning the groove to remove all loose laitance & washing with water applying crack filler with the aid of a putty blade compete all as specified and as directed. 250 RM
13 12 S&F Welded steel wire fabric (not exc 4 kg) complete to wood or steel member all as specified and as directed. 30 Kg
14 13 S&F GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge all as specified and as directed. 20 Sqm
15 14 Taking down cement plaster from brick or stone walls including racking out joints hacking for key, scrubbing down with water etc. all as specified and as directed. 2600 Sqm
16 15 M&L for 20 mm thick ready mix external sand faced cement plaster using factory manufactured pre mix/ready mix of roofy mix of approved make having minimum composition of C:S (1:4) using fully treated dry,well graded natural sand confirming to IS383 with neat cement rendering at all heights and locations in two coats for masonry and concrete surfaces including water proofing compound to the first coat of plaster as per manufacturers specifications, racking out joints,hacking of concrete surface,finishing,curing etc all as specified and as directed. 1000 Sqm
17 16 M&L for 12mm thick ready mix internal plaster of approved make in single coat at all heights and locations surface, watering , finishing, curing, scaffolding etc.complete all as specified and as directed. 1000 Sqm
18 17 M&L for 5mm thick ready mix internal plaster of approved make on ceiling at all heights and locations surface, watering , finishing, curing, scaffolding etc.complete all as specified and as directed. 600 Sqm
19 18 M&L for preparation of new treated surfaces and apply three coat of white wash to walls all as specified and as directed. 1000 Sqm
20 19 M&L for preparation of old treated surfaces and apply one coat of white wash to walls all as specified and as directed. 1000 Sqm
21 20 M&L for preparation of new treated surfaces and apply three coat of white wash to ceiling all as specified and as directed. 600 Sqm
22 21 All as per item No 20, here in before, but for on old ceiling. 600 Sqm
23 22 M&L for applying two coats of Anti fungal paint over a coat of primer to match the existing colour including preparation of newly plastered surface all as specified and as directed. 1000 Sqm
24 23 M&L for applying a coat of acrylic emulsion exterior paint (anti fungal paint-) on old decorative surfaces of walls, ceiling and cornices including preparation of surfaces by brooming down or steel wire brushing scrapping down with steel scrapper smoke soot moulds moss and efflorescent slats brading oil and greasy spots etc and making proper surface by applying ready mix preparatory putty wherever required complete all as manufacturers instructions and as directed. 1000 Sqm
25 24 M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide premier all as specified and as directed. 50 Sqm
26 25 M&L for one coat of synthetic enamel paint to old steel surface over 10 cm width or girth including preparation of surfaces all as specified and as directed. 30 Sqm
27 26 Dismantling of false ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified and as directed. 500 Sqm
28 27 S&F Anodised aluminium snap grid frame work in false ceiling of grid size 605x605 mm fixed with hangers 6mm dia, G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and as directed. 500 Sqm
29 28 Supply and fixing PVC False ceiling consisting of 600mmx600mm,10mm(+or - 0.25) thick plain colour PVC sheet manufactured by an ISO-9001-2008 certified company,complete as per direction of Engineer-in -Charge,manufacturer's specification & drawing. 900 Sqm
30 29 Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) all as specified and as directed. 57 Cum
31 30 M & L for 75 mm thick PCC 1 : 4 : 8, type D2 using 40mm graded stone aggregate Cement concrete as in Sub base all as specified and as directed. 300 Sqm
32 31 M&L for Plain Cement concrete M.15 grade(Nominal mix) using 40mm graded stone aggregate, 100mm thick as in floorings.finished even and smooth and laid in bays of 1500 x 1500mm all as specified and as directed. 300 Sqm
33 32 M&L for glass dividing strips,3mm thick and width of strip in 38mm flooring of slab work etc all as specified and as directed. 400 RM
34 33 M&L for cement concrete M.10 grade(Nominal mix) using 20mm graded stone aggregate, 50 mm thick , 75cm wide as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight) all as specified and as directed. 100 Sqm
35 34 Dismantling/taking down existing hessian base felt or clay tiles or any other water proofing treatment from roof/chajja including cement plaster, cleaning the surface and removing the dismantled debris to a distance exceeding 1.50 Km but not exceeding 5 Km to inside the MD land all as specified and as directed. 750 Sqm
36 35 M&L for rendering 10 mm thick in cement mortar 1:3 as in roof slab, Chajja drops, roof on brick or concrete surfaces including roughening surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust etc. all as specified and as directed. 750 Sqm
37 36 M&L for laying water proofing treatment using 4mm thick APP modified membrane consisting five layer membranes with features as specified weighing not less than 3.5 kg/sqm reinforced with oven polyester fiber @ 160gm/sqm laid over a coat of cold applied bituminous primer @ 0.40kg/sqm by torching the membrane and sealing the over lap by 100mm length side 150mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex@ 200ml bag of cement curved well before laying membrane all as per manufacturer instructions and as directed.\nNotes : (i) Irrespective of lap the net covered area shall only be measured for payment. \n(ii) Rate is inclusive of APP membrene ,SBR latex.\n(iii) Applying a coat of bituminous aluminium paint @ 200gm/sqm (min) in two coat 750 Sqm
38 37 Removing building materials etc.to a distance of 1.00 Km beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed. 16 Per load
39 38 Dismantling structural steel work all as specified and as directed. 10 Qtl
40 39 Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and as directed. 110 Sqm
41 40 S&F roof trusses (framed trussed purlin, crane ganries, rails and fastening and heavy bracket framing) beam, tee, angle, channel or flat section) including distance pieces cleats adjacent wall/column etc all as specified and as directed. 500 Kg
42 41 Erection fixing and fabrication of roof trusses (framed trussed purlin, crane gantries, rails and fastening and heavy bracket framing) beam, tee, angle, channel or flat section) including distance pieces cleats adjacent wall/column etc all as specified and as directed. 500 Kg
43 42 S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. 60 Sqm
44 43 Fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.\nNote : Useful / serviceable sheet obtained under dismantling shall be used. 50 Sqm
45 44 Demolition of brick/stone/block masnory built in cement mortar all as specified and as directed. 30 Cum
46 45 M & L for Pre-cast cement concrete block masonry with solid blocks grade C-5 exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and as directed. 30 Cum
47 46 M & L for rendering 10mm on brick or concrete surfaces in cement mortar 1:4 finish even and smooth without using extra cement all as specified and as directed. 340 Sqm
48 46.1 Schedule 'A' -Part II (E/M Portion)
49 47 Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc complete all as specified and as directed. 152 Point
50 48 Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and as directed for one light point controlled by one, one way switch 06 Amps.\nNote :- Rate is inclusive of Cutting/chases of wall/ floor/ ceiling 110 Point
51 49 All as per item No 48 here in before, but for one light point controlled by two 2 - way switches with cables 1.5 sqmm size all as specified and as directed. 7 Point
52 50 All as per item No 48 here in before, but for 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board all as specified and as directed. 30 Point
53 51 All as per item No 48 here-in-before, but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and as directed. 12 Point
54 52 Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts all as specified and as directed. 140 Each
55 53 Supply & Fixing modular switch 2 way 6A, 1 module, 230 volts all as specified and as directed. 14 Each
56 54 Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts all as specified and as directed. 12 Each
57 55 Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module all as specified and as directed. 30 Each
58 56 Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module all as specified and as directed. 12 Each
59 57 Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks all as specified and as directed. 110 Each
60 58 Supply & Fixing stepped type 2 module modular electronic fan regulator flush type including removal of old one all as specified and as directed. 2 Each
61 59 Supply & fixing MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts all as specified and as directed. 30 Each
62 60 Supply & fixing MCB, 6 to 32 Amps, single pole neutral, C Series, 10 KA, 240 volts all as specified and as directed. 4 Each
63 61 Supply and fixing MCB 63 Amps TP, C Series, 10 KA, 415 volts all as specified and as directed. 8 Each
64 62 Supply & Fixing sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and directed. 4 Each
65 63 Supply & fixing MCCB (DB) vertical TPN 8 way double door with suitable size of busbar neutral/earth link connector and including 100 Amps rated MCCB, 4P, 10 KA breaking capacity including dismantling of old one complete all as specified and as directed. 1 Each
66 64 Supply and Fixing LED light fitting Recess/Surface mounting LED flat panel 2'x2' with high efficient LEDs & glare free opal diffuser of 34 watts LED including dismantling old fittings all as specified and as directed. 40 Each
67 65 Supply & Fixing submain wiring with 2 Runs of 2.5 Sqmm, PVC insulated, unsheathed, single core, multistranded, 1100 volts, FRLS copper conductor cable drawn in and including PVC conduit concealed with all accessories as required along with 1 run of 2.5 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as specified and as directed.\nNote : 2 runs of main conductor and one run of earth conductor and one run of PVC conduit shall be measured as one length. 100 RM
68 66 Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as specified and as directed.\nNote : 2 runs of main conductor and one run of earth conductor and one run of PVC conduit shall be measured as one length. 80 RM
69 67 Supply and fixing Earth continuity conductor or main earthing lead of 16 sqmm PVC insulated copper conductor drawn in and including through concealed steel conduit/pipe dia and connecting from existing earthing to Distribution box complete all as specified and as directed. 30 RM
70 68 Supply & fixing brushless direct current (BLDC) ceiling fan 1200mm sweep (ISI Marked), 230 volts, 26 Watt including connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard all as specified and as directed. 2 Each
71 69 Supply & fixing metallic exhaust fan 300mm sweep, heavy duty, 230 volts including louvers of suitable size and dismantling of old one depositing in MES store yard all as specified and as directed. 6 Each
72 70 M&L for earthing complete with steel earth plate electrode 60cm x 60cm x6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts, nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 3 of SSR part 1 Including necessary excavation disintegrated hard rock filling earth of 15 mm thick and provision of earth pit provision of 20mm dia with funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engineer-in-Charge.\nNote : GI earth wire upto 7.5 RM is included in the unit rate quoted. 1 Each set
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail