}

Supply Of Ice Lined Refrigerator.Ice Lined Refrigerator., Ice Lined Refrigerator 1. Gross Storage Capacity: At Least 150 Litres. 2. Net Vaccine Storage Capacity: At Least 110 Litres Within Basket In Place. 3. Chest Type Device With Cfc Free Insulation. 4.-Kerala

Southern Railway has published Supply Of Ice Lined Refrigerator.Ice Lined Refrigerator., Ice Lined Refrigerator 1. Gross Storage Capacity: At Least 150 Litres. 2. Net Vaccine Storage Capacity: At Least 110 Litres Within Basket In Place. 3. Chest Type Device With Cfc Free Insulation. 4.. Submission Date for this Tender is 05-04-2021. Spare Part Tenders in Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

27477138
Supply Of Ice Lined Refrigerator.Ice Lined Refrigerator., Ice Lined Refrigerator 1. Gross Storage Capacity: At Least 150 Litres. 2. Net Vaccine Storage Capacity: At Least 110 Litres Within Basket In Place. 3. Chest Type Device With Cfc Free Insulation. 4.
Tender
Indian
Kerala
05-04-2021

Tender Details

Supply Of Ice Lined Refrigerator.Ice Lined Refrigerator., Ice Lined Refrigerator 1. Gross Storage Capacity: At Least 150 Litres. 2. Net Vaccine Storage Capacity: At Least 110 Litres Within Basket In Place. 3. Chest Type Device With Cfc Free Insulation. 4. Type: Compression Cycled, Cfc %U2013 Free ( Both For Refrigeration And Insulation ) . All System Tubing ( Suction Tube, Freezer Tube And Condensing Tube ) Should Be Of Minimum 99.97% Of Pure Copper Coil. 5. Refrigerant: Non %U2013cfc, Non Hcfc, Eco-Friendly Refrigerant. 6. Temperature Of All Vaccines To Remain At +2 Degree Celsius To +8 Degree Celsius During Continuous Availability Of Energy At Ambient Temperature +5 To +45 Degree Celsius With Intermittent / Continuous Electricity Supply 8 Hrs In A 24 Hrs Cycle. The Temperature Difference Between Any Two Points In The Cabinet Should Not Be More Than +2 Deg. Celsius Once Stabilized. 7. Target Holdover Time Should Be At A Minimum Of 24 Hrs Or More In A Continuous External Temperature Up To 43 Deg C. 8. Provision For Drainage For The Waste Water. 9. The Unit Should Have Ground Clearance Of Minimum 100Mm. 10. On / Off Switch And Power Indicator Should Be Available. 11. A Microprocessor Based Control Unit Should Be Provided For Setting Of Temperature. 12. Sensor: Fast Response Ntc Thermistor Sensor. The Sensor Should Be Placed 25 To 50 Mm Above Base Of Storage Chamber. 13. Power On Led / Lcd Indicator. 14. Audio And Visual Alarm Against The Violation Of Temperature Range ( Beyond +2 To +8 Degree C Range ) . 15. Programmable Micro- Processor Control Unit With Child Lock Facility. 16. The Equipment Should Have Auto Defrosting Program. 17. Vaccine Storage Basket Allowing Free Circulation Of Air, Having The Size Suitable To Match The Net Volume Requirement. There Should Be Minimum 3 Wire Baskets Attached To The Inside Chamber. 18. Stem Alcohol Thermometer With Following Features- A ) Specifications And Standard As Per Who / Mohfw With Temp Range - -30 Deg C To +50 Deg C B ) Who Specification Reference: E6 / Th3 C ) Applies To Procedures: E6 / Prcoc / 2 19. Voltage Stabilizer As Per The Mohfw Approved Specifications And Standards. A ) Automatic Regulation Relay Type Voltage Stabilizer Will Provide A Pre-Set Ac Output 220V + / -5% For Fluctuating Ac Input Voltage. B ) Should Work For Input Voltage Range Of 150-280 Volt Ac, Single Phase, With Low Voltage Cut-Off When The Input Voltage Falls Below 150V + / -5V & High Voltage Cut-Off When The Input Voltage Goes Beyond 280V + / -5V. C ) Protection: - Over / Under Voltage, Over Load & Short Circuit. D ) Provision For An Output Socket Of 5 Amps Isi Marked. 20. The Supplier Is Required To Maintain All The Spare Parts Throughout The Warrantee Period And Cmc Period. 21. Product Should Be Fda / Ce / Iso Approved. 22. The Product Should Meet Who / Unicef Standard Who / Pqs / E003 For Ice Lined Refrigerators. 23. Test And Inspection As Per Who Procedure Reference Who / Pqs / E003 Should Be Done And Valid Certificate Must Be Obtained. Testing And Inspection Should Be Carried Out From A Who Certified Lab / Nabl / Ilac / Stqc Labs. Certificate Of Testing Should Be Currently Valid Till The Supply And Same Must Be Verified By Inspecting Authority. 24. A Paper Copy Of Technical / Wiring Diagram To Be Supplied In English. 25. The Original Company User Manual With Brochure In English Should Be Submitted.

Key Value

Document Fees
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail