Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Phed S, Executive Engineer PHED dn. Kuchaman-Rajasthan

Public Health Engineering Department-PHED has published Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Phed S. Submission Date for this Tender is 15-04-2021. Submersible Pump Tenders in Executive Engineer PHED dn. Kuchaman Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

27461999
Corrigendum : Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Phed S
National Competitive Bid
Indian
Rajasthan
Executive Engineer PHED dn. Kuchaman
15-04-2021

Tender Details

Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels Cables and other allied works including commissioning and testing of tube well under PHED Sub Dn. Kuchaman with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period (ARC)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Apr-2021 Undertaking Technical Bid 05-04-2021
2 05-Apr-2021 ext. date Date 15-04-2021
3 12-Apr-2021 Certificate of Rig Registration in District Nagaur Technical Bid 15-04-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels Cables and other allied works including commissioning and testing of tube well under PHED Sub Dn. Kuchaman with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period (ARC)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Construction of tube well upto 100 mtr. Depth in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soil & over burden including lowering of casing pipe (if required) excluding cost of casing pipe, as epr IS: 2800 part 1 : 1991 and IS : 2800 Part II : 1979 (both amended upto date) and technicalb specifications. The work would be completed after obtaining sand free water. The TW should have a through out bore as per nominal dia of casing pipe BI01010001010000000000000515BI0100001112
2 2 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001113 170 per meter
3 3 Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth BI01010001010000000000000515BI0100001114 100 per meter
4 4 Construction of tube well from ground level and upto 100 mtr. Depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS : 2800 Part I : 1991 and IS : 2800 Part II : 1979 (both amended upto date) and technicalb specifications, with gravel as per IS : 4097-1967 and it's packing as per IS : 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. BI01010001010000000000000515BI0100001115
5 5 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001116 130 per meter
6 6 Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth BI01010001010000000000000515BI0100001117 100 per meter
7 7 Nominal bore 250 mm dia. BI01010001010000000000000515BI0100001118 130 per meter
8 8 Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth BI01010001010000000000000515BI0100001119 100 per meter
9 9 Construction of TW from ground level and upto 100 mtr. Depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS : 2800 Part 1: 1991 and IS 2800 Part Ii : 1979 (Both amended upto date) and technical specification for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe BI01010001010000000000000515BI0100001120
10 10 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001121 130 per meter
11 11 Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth from ground level BI01010001010000000000000515BI0100001122 100 per meter
12 12 Nominal bore 250 mm dia. BI01010001010000000000000515BI0100001123 130 per meter
13 13 Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth from ground level BI01010001010000000000000515BI0100001124 100 per meter
14 14 Construction of TW after completion of drilling by rotary method & upto 150 mtr. depth in all type of rocks by DTH system as per IS : 2800 part 1 : 1991 and IS : 2800 Part II. 1979 (both amended upto date) and technical specification. The work shall be deemed completed only after obtaining sand free water. The bore well shold have a throughout nominal size bore beyond casing pipe BI01010001010000000000000515BI0100001125
15 15 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001126 130 per meter
16 16 Add 15% extra on depth more than 150 mtr. For drilling beyond 150 mtr depth from ground level BI01010001010000000000000515BI0100001127 100 per meter
17 17 Construciton of TW from ground level and upto 100 mtr. Depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc, by "bailing method" and without gravel packing as per IS: 2800 part I : 1991 and IS 2800 Part II : 1979 (both amended upto date) and technical specifications, The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering fo casing pipe but excluding cost of the casing pipe. The TW should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water. BI01010001010000000000000515BI0100001128
18 18 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001129 130 per meter
19 19 Construction of TW from ground level and upto 100 mtr. Depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: 2800 Part 1: 1979 (both amended upto date) and technical specifications, The work includes lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water BI01010001010000000000000515BI0100001130
20 20 Nominal bore 200 mm dia. BI01010001010000000000000515BI0100001131 130 per meter
21 21 Development of Tube well as per I.S.11189:1985 and IS-2800 (Part-I):1991 (both amended upto date) using suitable compressor to give sand- free water for required yield of the gravel packed TW BI01010001010000000000000515BI0100001132 10 per hour
22 22 Supply & fixing tube well cover of MS sheet 8 mm thick at top & 5 mm thick 100 mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45 cm log & two GI flanges at both end in 80 mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation presuure gauge) shall be provided & welded with 80 mm GI nipple near top plate nipple shall be provided with end plug. BI01010001010000000000000515BI0100001133
23 23 200 mm dia BI01010001010000000000000515BI0100001134 2 No
24 24 250 mm dia BI01010001010000000000000515BI0100001135 1 No
25 25 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date BI01010001010000000000000515BI0100001136
26 26 200 mm dia nominal bore of 5.4 mm thickness BI01010001010000000000000515BI0100001137 50 per meter
27 27 250 mm dia nominal bore of 7.1 mm thickness BI01010001010000000000000515BI0100001138 50 per meter
28 28 Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes BI01010001010000000000000515BI0100001139
29 29 200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m) BI01010001010000000000000515BI0100001140 130 per meter
30 30 250 mm dia nominal bore of 7.1 mm thickness mass of tube 46.57 Kg/m) BI01010001010000000000000515BI0100001141 130 per meter
31 31 Providing & Lowering in tubewell ISI marked GI Pipe "B" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. BI01010001010000000000000515BI0100001142
32 32 50 mm dia BI01010001010000000000000515BI0100001143 250 per meter
33 33 65 mm dia BI01010001010000000000000515BI0100001144 100 per meter
34 34 80 mm dia BI01010001010000000000000515BI0100001145 100 per meter
35 35 Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc. BI01010001010000000000000515BI0100001146
36 36 3 core 4.0 mm2 BI01010001010000000000000515BI0100001147 50 per meter
37 37 3 core 6.0 mm2 BI01010001010000000000000515BI0100001148 560 per meter
38 38 3 core 10.0 mm2 BI01010001010000000000000515BI0100001149 50 per meter
39 39 3 core 16.0 mm2 BI01010001010000000000000515BI0100001150 50 per meter
40 40 Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect. BI01010001010000000000000515BI0100001151
41 41 Up to 5.5 KW (7.5 HP) & head up to 120 mtr BI01010001010000000000000515BI0100001152 5.5 KW
42 42 Up to 5.5 KW (7.5 HP) & head above 120 mtr BI01010001010000000000000515BI0100001153 5.5 KW
43 43 7.5 KW (10 HP) & head up to 120 mtr BI01010001010000000000000515BI0100001154 7.5 KW
44 44 7.5 KW (10 HP) & head above 120 mtr BI01010001010000000000000515BI0100001155 7.5 KW
45 45 9.3 KW (12.5 HP) & head up to 120 mtr BI01010001010000000000000515BI0100001156 9.3 KW
46 46 9.3 KW (12.5 HP) & head above 120 mtr BI01010001010000000000000515BI0100001157 9.3 KW
47 47 11 KW (15 HP) & head up to 120 mtr BI01010001010000000000000515BI0100001158 11 KW
48 48 11 KW (15 HP) & head above 120 mtr BI01010001010000000000000515BI0100001159 11 KW
49 49 13 KW (17.5 HP) & head up to 120 mtr BI01010001010000000000000515BI0100001160 13 KW
50 50 13 KW (17.5 HP) & head above 120 mtr BI01010001010000000000000515BI0100001161 13 KW
51 51 15 KW (20 HP) & above, head up to 120 mtr BI01010001010000000000000515BI0100001162 15 KW
52 52 15 KW (20 HP) & above, head above 120 mtr BI01010001010000000000000515BI0100001163 15 KW
53 53 S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset BI01010001010000000000000515BI0100001164 1 Each
54 54 Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, DOL, starter, overload rely, ampere meter, volt meter phase, preventer, phase indicator, lighting arrangment etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage MS sheet with power coating. Panel should be of minimum size 900 x 600 x 300mm with stand (made of angle iron of size 35x35x5 mm) duly bolted/ serewed with enclosure box having 4 elgs, each leg's length 18" and double door incuding in built locking system. The legs should be embedded in M-15 cement cocrete platform. The size of CC platform should be equal or bigger than the base size of panel having high of atlest 200 mm from ground level. The panel shoud have opening of suitable size infront of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC supply. BI01010001010000000000000515BI0100001165
55 55 Up to 5.00 HP BI01010001010000000000000515BI0100001166 1 Nos
56 56 Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg's length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply BI01010001010000000000000515BI0100001167
57 57 Above 5 HP and up to 10 HP BI01010001010000000000000515BI0100001168 1 Nos
58 58 Above 10 HP and up to 15 HP BI01010001010000000000000515BI0100001169 1 Nos
59 59 Above 15 HP BI01010001010000000000000515BI0100001170 1 Nos
60 60 Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia BI01010001010000000000000515BI0100001171 2 Nos
61 61 Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 80 mm dia BI01010001010000000000000515BI0100001172 2 Nos
62 62 Providing, installing, festing and comm. Of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia BI01010001010000000000000515BI0100001173
63 63 50 mm dia BI01010001010000000000000515BI0100001174 1 Nos
64 64 65 mm dia BI01010001010000000000000515BI0100001175 1 Nos
65 65 Supplying & Installing 100mm dia mtr. Sealed diaphragm bourden type pressure gauge along with all jointing materials Range 0 to 10 kg of makes specified in specifications with sefety cover BI01010001010000000000000515BI0100001177 2 Nos
66 66 Supplying & fixing of CI D/F sluice valve of 80 mm as per IS 14846/2000 PN. 1.0 specifications including tail pieces and cost of all labour jointing material with nuts and bolts and rubber sheets etc. complete of makes specified in specifications. BI01010001010000000000000515BI0100001178 2 Nos
67 67 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required BI01010001010000000000000515BI0100001179 3 Nos
68 68 Testing verticality of tube well by plumping system and yield test and draw down test by pumping system as per IS : 2800 (Part- II) - 1979 as amended up to date BI01010001010000000000000515BI0100001180 3 Nos
69 69 Supplying & packing P-gravel suitable for slot size/ mesh size as suggested in IS 2800 (Part-1) 1991 with latest amendment BI01010001010000000000000515BI0100001181 3 Cum
70 70 Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets) BI01010001010000000000000515BI0100001182
71 71 O&M for Third Year BI01010001010000000000000515BI0100001183 36 Per Month
72 72 O&M for Fourth Year BI01010001010000000000000515BI0100001184 36 Per Month
73 73 O&M for Fifth Year BI01010001010000000000000515BI0100001185 36 Per Month