Public Health Engineering Department-PHED has published Construction And Commissioning Of Bore Hole By Dth/Rotary/ Combination Rig Of 200 Mm Dia, Supply And Installation Of Energy Efficient Submersible Pump Sets, Panels Cables And Other Allied Works Including Commissioning And Testing Of Tube Well Under Phed S. Submission Date for this Tender is 15-04-2021. Submersible Pump Tenders in Executive Engineer PHED dn. Kuchaman Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Apr-2021 | Undertaking | Technical Bid | 05-04-2021 |
2 | 05-Apr-2021 | ext. date | Date | 15-04-2021 |
3 | 12-Apr-2021 | Certificate of Rig Registration in District Nagaur | Technical Bid | 15-04-2021 |
Name of Work: Construction and Commissioning of bore hole by DTH/Rotary/ Combination rig of 200 mm dia, supply and installation of energy efficient Submersible Pump sets, Panels Cables and other allied works including commissioning and testing of tube well under PHED Sub Dn. Kuchaman with 24 months defect liability, 3 years operation and maintenance after completion of defect liability period (ARC) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Construction of tube well upto 100 mtr. Depth in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soil & over burden including lowering of casing pipe (if required) excluding cost of casing pipe, as epr IS: 2800 part 1 : 1991 and IS : 2800 Part II : 1979 (both amended upto date) and technicalb specifications. The work would be completed after obtaining sand free water. The TW should have a through out bore as per nominal dia of casing pipe | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001113 | 170 | per meter |
3 | 3 | Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth | BI01010001010000000000000515BI0100001114 | 100 | per meter |
4 | 4 | Construction of tube well from ground level and upto 100 mtr. Depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS : 2800 Part I : 1991 and IS : 2800 Part II : 1979 (both amended upto date) and technicalb specifications, with gravel as per IS : 4097-1967 and it's packing as per IS : 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. | BI01010001010000000000000515BI0100001115 | ||
5 | 5 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001116 | 130 | per meter |
6 | 6 | Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth | BI01010001010000000000000515BI0100001117 | 100 | per meter |
7 | 7 | Nominal bore 250 mm dia. | BI01010001010000000000000515BI0100001118 | 130 | per meter |
8 | 8 | Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth | BI01010001010000000000000515BI0100001119 | 100 | per meter |
9 | 9 | Construction of TW from ground level and upto 100 mtr. Depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling method as per IS : 2800 Part 1: 1991 and IS 2800 Part Ii : 1979 (Both amended upto date) and technical specification for removal of overburden. The work includes the cost of lowering of casing pipe, but excludes the cost of casing pipe | BI01010001010000000000000515BI0100001120 | ||
10 | 10 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001121 | 130 | per meter |
11 | 11 | Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth from ground level | BI01010001010000000000000515BI0100001122 | 100 | per meter |
12 | 12 | Nominal bore 250 mm dia. | BI01010001010000000000000515BI0100001123 | 130 | per meter |
13 | 13 | Add 15% extra on depth more than 100 mtr. For drilling beyond 100 mtr depth from ground level | BI01010001010000000000000515BI0100001124 | 100 | per meter |
14 | 14 | Construction of TW after completion of drilling by rotary method & upto 150 mtr. depth in all type of rocks by DTH system as per IS : 2800 part 1 : 1991 and IS : 2800 Part II. 1979 (both amended upto date) and technical specification. The work shall be deemed completed only after obtaining sand free water. The bore well shold have a throughout nominal size bore beyond casing pipe | BI01010001010000000000000515BI0100001125 | ||
15 | 15 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001126 | 130 | per meter |
16 | 16 | Add 15% extra on depth more than 150 mtr. For drilling beyond 150 mtr depth from ground level | BI01010001010000000000000515BI0100001127 | 100 | per meter |
17 | 17 | Construciton of TW from ground level and upto 100 mtr. Depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc, by "bailing method" and without gravel packing as per IS: 2800 part I : 1991 and IS 2800 Part II : 1979 (both amended upto date) and technical specifications, The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering fo casing pipe but excluding cost of the casing pipe. The TW should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water. | BI01010001010000000000000515BI0100001128 | ||
18 | 18 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001129 | 130 | per meter |
19 | 19 | Construction of TW from ground level and upto 100 mtr. Depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: 2800 Part 1: 1979 (both amended upto date) and technical specifications, The work includes lowering of housing and strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water | BI01010001010000000000000515BI0100001130 | ||
20 | 20 | Nominal bore 200 mm dia. | BI01010001010000000000000515BI0100001131 | 130 | per meter |
21 | 21 | Development of Tube well as per I.S.11189:1985 and IS-2800 (Part-I):1991 (both amended upto date) using suitable compressor to give sand- free water for required yield of the gravel packed TW | BI01010001010000000000000515BI0100001132 | 10 | per hour |
22 | 22 | Supply & fixing tube well cover of MS sheet 8 mm thick at top & 5 mm thick 100 mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45 cm log & two GI flanges at both end in 80 mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation presuure gauge) shall be provided & welded with 80 mm GI nipple near top plate nipple shall be provided with end plug. | BI01010001010000000000000515BI0100001133 | ||
23 | 23 | 200 mm dia | BI01010001010000000000000515BI0100001134 | 2 | No |
24 | 24 | 250 mm dia | BI01010001010000000000000515BI0100001135 | 1 | No |
25 | 25 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS: 8110-2000 or as amended up to date | BI01010001010000000000000515BI0100001136 | ||
26 | 26 | 200 mm dia nominal bore of 5.4 mm thickness | BI01010001010000000000000515BI0100001137 | 50 | per meter |
27 | 27 | 250 mm dia nominal bore of 7.1 mm thickness | BI01010001010000000000000515BI0100001138 | 50 | per meter |
28 | 28 | Supply of ERW M.S. black casing pipe ISI marked (IS : 4270/2001) or amended upto date of grade Fe 410 of following sizes | BI01010001010000000000000515BI0100001139 | ||
29 | 29 | 200 mm dia nominal bore of 5.4 mm thickness and mass of tube 28.46 Kg/m) | BI01010001010000000000000515BI0100001140 | 130 | per meter |
30 | 30 | 250 mm dia nominal bore of 7.1 mm thickness mass of tube 46.57 Kg/m) | BI01010001010000000000000515BI0100001141 | 130 | per meter |
31 | 31 | Providing & Lowering in tubewell ISI marked GI Pipe "B" class as per IS : 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. | BI01010001010000000000000515BI0100001142 | ||
32 | 32 | 50 mm dia | BI01010001010000000000000515BI0100001143 | 250 | per meter |
33 | 33 | 65 mm dia | BI01010001010000000000000515BI0100001144 | 100 | per meter |
34 | 34 | 80 mm dia | BI01010001010000000000000515BI0100001145 | 100 | per meter |
35 | 35 | Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc. | BI01010001010000000000000515BI0100001146 | ||
36 | 36 | 3 core 4.0 mm2 | BI01010001010000000000000515BI0100001147 | 50 | per meter |
37 | 37 | 3 core 6.0 mm2 | BI01010001010000000000000515BI0100001148 | 560 | per meter |
38 | 38 | 3 core 10.0 mm2 | BI01010001010000000000000515BI0100001149 | 50 | per meter |
39 | 39 | 3 core 16.0 mm2 | BI01010001010000000000000515BI0100001150 | 50 | per meter |
40 | 40 | Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS : 8034-2011 (pump) and IS 9283-2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect. | BI01010001010000000000000515BI0100001151 | ||
41 | 41 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001152 | 5.5 | KW |
42 | 42 | Up to 5.5 KW (7.5 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001153 | 5.5 | KW |
43 | 43 | 7.5 KW (10 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001154 | 7.5 | KW |
44 | 44 | 7.5 KW (10 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001155 | 7.5 | KW |
45 | 45 | 9.3 KW (12.5 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001156 | 9.3 | KW |
46 | 46 | 9.3 KW (12.5 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001157 | 9.3 | KW |
47 | 47 | 11 KW (15 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001158 | 11 | KW |
48 | 48 | 11 KW (15 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001159 | 11 | KW |
49 | 49 | 13 KW (17.5 HP) & head up to 120 mtr | BI01010001010000000000000515BI0100001160 | 13 | KW |
50 | 50 | 13 KW (17.5 HP) & head above 120 mtr | BI01010001010000000000000515BI0100001161 | 13 | KW |
51 | 51 | 15 KW (20 HP) & above, head up to 120 mtr | BI01010001010000000000000515BI0100001162 | 15 | KW |
52 | 52 | 15 KW (20 HP) & above, head above 120 mtr | BI01010001010000000000000515BI0100001163 | 15 | KW |
53 | 53 | S&F MS clamps set of 50 mm x 6 mm flat form iron with nuts and bolts etc for holding the riser pipe assembly of submersible pumpset | BI01010001010000000000000515BI0100001164 | 1 | Each |
54 | 54 | Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, DOL, starter, overload rely, ampere meter, volt meter phase, preventer, phase indicator, lighting arrangment etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage MS sheet with power coating. Panel should be of minimum size 900 x 600 x 300mm with stand (made of angle iron of size 35x35x5 mm) duly bolted/ serewed with enclosure box having 4 elgs, each leg's length 18" and double door incuding in built locking system. The legs should be embedded in M-15 cement cocrete platform. The size of CC platform should be equal or bigger than the base size of panel having high of atlest 200 mm from ground level. The panel shoud have opening of suitable size infront of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC supply. | BI01010001010000000000000515BI0100001165 | ||
55 | 55 | Up to 5.00 HP | BI01010001010000000000000515BI0100001166 | 1 | Nos |
56 | 56 | Supply and fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star-delta starter, over load relya, ampere n meter with CTs, volt meter, phase preventor, suitable starting copacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these equipments shall be housed by panel box made out form 18 guage MS sheet with powder coating. panel should be of minimum size 900 X 600 x 450 mm with stand (made of angle iron of size 35x35x5m) duly bolted/ screwed with enclosure box having 4 legs, each leg's length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC plate form should be equal or bigger thatn the base size of panel having height of at least 200 mm from gound level. The panel should have opening of suitable size in fron of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt AC supply | BI01010001010000000000000515BI0100001167 | ||
57 | 57 | Above 5 HP and up to 10 HP | BI01010001010000000000000515BI0100001168 | 1 | Nos |
58 | 58 | Above 10 HP and up to 15 HP | BI01010001010000000000000515BI0100001169 | 1 | Nos |
59 | 59 | Above 15 HP | BI01010001010000000000000515BI0100001170 | 1 | Nos |
60 | 60 | Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 65 mm dia | BI01010001010000000000000515BI0100001171 | 2 | Nos |
61 | 61 | Providing and fixing of double flanged, CI body, ISI marked NRV of approved make of size 80 mm dia | BI01010001010000000000000515BI0100001172 | 2 | Nos |
62 | 62 | Providing, installing, festing and comm. Of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia | BI01010001010000000000000515BI0100001173 | ||
63 | 63 | 50 mm dia | BI01010001010000000000000515BI0100001174 | 1 | Nos |
64 | 64 | 65 mm dia | BI01010001010000000000000515BI0100001175 | 1 | Nos |
65 | 65 | Supplying & Installing 100mm dia mtr. Sealed diaphragm bourden type pressure gauge along with all jointing materials Range 0 to 10 kg of makes specified in specifications with sefety cover | BI01010001010000000000000515BI0100001177 | 2 | Nos |
66 | 66 | Supplying & fixing of CI D/F sluice valve of 80 mm as per IS 14846/2000 PN. 1.0 specifications including tail pieces and cost of all labour jointing material with nuts and bolts and rubber sheets etc. complete of makes specified in specifications. | BI01010001010000000000000515BI0100001178 | 2 | Nos |
67 | 67 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required | BI01010001010000000000000515BI0100001179 | 3 | Nos |
68 | 68 | Testing verticality of tube well by plumping system and yield test and draw down test by pumping system as per IS : 2800 (Part- II) - 1979 as amended up to date | BI01010001010000000000000515BI0100001180 | 3 | Nos |
69 | 69 | Supplying & packing P-gravel suitable for slot size/ mesh size as suggested in IS 2800 (Part-1) 1991 with latest amendment | BI01010001010000000000000515BI0100001181 | 3 | Cum |
70 | 70 | Maintiance of TWs which includes round the the clock monitoring of TWs of all sizes, complete including cost of material components required to repair pump sets, staters meters etc. of electrict panel of TWs, lowering and unlowreing of pump sets complete in all respect maintiance of log book and histrory sheets as directed by Engiener - in- charge for TW per month. (excluding repairing of Pump sets) | BI01010001010000000000000515BI0100001182 | ||
71 | 71 | O&M for Third Year | BI01010001010000000000000515BI0100001183 | 36 | Per Month |
72 | 72 | O&M for Fourth Year | BI01010001010000000000000515BI0100001184 | 36 | Per Month |
73 | 73 | O&M for Fifth Year | BI01010001010000000000000515BI0100001185 | 36 | Per Month |