| 1 | 1 | Civil Work | ISC0000103 | | |
|---|
| 2 | 1.01 | E/Work excavation ni foundation, trenches etc in all kinds of soil not exceeding 2mtr depth including dressing of bottom and sides of trenches stacking the earth excavated clear from the edge of excavation complete in all respect as per approved design, PWD specification and directed by Engineer in charge (HSR item No. 6.6) | ISC0000104 | 53.626 | 100 Cum |
|---|
| 3 | 2 | E/Work excavation in ordinary soil i/c all leads, lifts and other allowances with an avg lead 495 mtr complete in all respect (HSR item No. 6.2(b)(c), 6.3(i)) | ISC0000105 | 351.17 | 100 Cum |
|---|
| 4 | 3 | Cement Concrete 1:3:6 with Stone aggregate 20mm nominal size in foundation & plinth complete in all respect as per approved design, PWD specification & direction of engineer in charge (HSR item No. 10.40) | ISC0000106 | 21.46 | Cum |
|---|
| 5 | 4 | 1st class brick work laid in cement sand mortar 1:3 foundation & plinth complete in all respect as per approved design, PWD specification & direction of engineer in charge (HSR item No. 11.5) | ISC0000107 | 27.93 | Cum |
|---|
| 6 | 5 | 12mm thick cement plaster 1:4 complete in all respect as per approved design, PWD specification & direction of engineer in charge (HSR item No. 15.5) | ISC0000108 | 51.55 | Sqm |
|---|
| 7 | 6 | Centering & shuttering for sides & soffits of beam complete in all respect as per approved design, PWD specification & direc | ISC0000109 | 24.72 | Sqm |
|---|
| 8 | 7 | Centering & shuttering for flat surface of slab complete in all respect as per approved design, PWD specification and directed by Engineer in charge (HSR item No. 9.1) | ISC0000110 | 17.679 | Sqm |
|---|
| 9 | 8 | Cement Concrete 1:1:2 plain in foundation & plinth complete in all respect as per approved design, PWD specification & direction of engineer in charge (HSR item No. 10.43) | ISC0000111 | 1.972 | Cum |
|---|
| 10 | 9 | Cement concrete 1:1.5:3 with Stone aggregate 20mm nominal size for reinforced concrete work, but excluding steel reinforcement, centering & shuttering in foundation & plinth complete in all respect as per PWD specification and direction of Engineer in charge (HSR item No. 10.79 + 10.95) (a) | ISC0000112 | 14.86 | Cum |
|---|
| 11 | 10 | Cold twisted deformed (ribbed/tor steel) bars for RCC work not including in complete rate of RCC including bending, binding and placing in position complete in all respect as per approved design, PWD specification & direction of engineer in charge (HSR item No. 18.22) | ISC0000113 | 12.02 | Qtl. |
|---|
| 12 | 11 | Painting two coats ready mixed exterior paint in all shades complete in all respect as per approved design, PWD specification and directed by Engineer in charge (HSR item No. 16.24 + 16.26) | ISC0000114 | 34.207 | Sqm |
|---|
| 13 | 12 | Single layer brick lining laid in 6.83cm thick brick 22.86 x 11.11cm laid in 1:3 mortar over 6mm thick cement mortar 1:3 over 10mm thick cement plaster 1:3 on 10mm thick cement plaster 1:6 on sub grade complete in all respect as per approved design, PWD specification & direction of engineer in charge. | ISC0000115 | 38.926 | Sqm |
|---|
| 14 | 13 | Brick on edge coping in 1:3 cement sand mortar over 10mm thick cement plaster 1:6 complete in all respect as per approved design, PWD specification & direction of engineer in charge | ISC0000116 | 3.483 | Sqm |
|---|