| 1 | 1 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth (for taking up or laying of MS / CI / GI pipes) and getting out in hard/dense soil complete all as specified and directed. | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth (for taking up or laying of MS/CI/GI pipes) and getting out in hard/dense soil complete all as specified and directed. | 180 | Cum |
|---|
| 2 | 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 150 | Cum |
|---|
| 3 | 3 | Removing excavated surplus soils not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | Removing excavated surplus soils n.exc 50 m and deposited where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. | 30 | Cum |
|---|
| 4 | 4 | M&L for welding /cutting work for MS pipe of dia 150 to 300 mm at leakage pipe and fixing the pipe with new pipe of existing dia of and welding the both side joints with required length of MS pipe to restore the water supply complete all as specified and as directed by Engr-in-charge.\nNote :- Rates are deemed to be including hiring of T&P required at site.\n | M&L for welding /cutting work for MS pipe of dia 150 to 300 mm at leakage pipe and fixing the pipe with new pipe of existing dia of and welding the both side joints with required length of MS pipe to restore the water supply all as directed by Engr-in-charge.\nNote :- Rates are deems to be including heiring of T&P required at site.\n | 6 | Each Job |
|---|
| 5 | 5 | Supply and fixing Cast iron rising sluice valve both end flanged class PN 1.6 conforming to IS-14846-2000 with iron wheel head and brass spindle including necessary joint with nuts bolt, washer, rubber or fiber board gasket, etc and testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes :- | Supply and fixing Cast iron rising sluice valve both end flanged class PN 1.6 conforming to IS-14846-2000 with iron wheel head and brass spindle including necessary joint with nuts bolt, washer, rubber or fiber board gasket, etc and testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes :- | | |
|---|
| 6 | 5.01 | 150 mm bore complete all as specified and as directed. | (a) 150 mm bore | 4 | Each |
|---|
| 7 | 5.02 | 200 mm bore complete all as specified and as directed. | (b) 200 mm bore | 1 | Each |
|---|
| 8 | 5.03 | 250 mm bore complete all as specified and as directed. | (a) 250 mm bore | 2 | Each |
|---|
| 9 | 5.04 | Note: - Rate quoted by the contractor inclusive of necessary arrangement required for fixing of the item. | | | |
|---|
| 10 | 6 | Supply and fixing Cast iron non return valve both end flanged and fixed to the existing pipe line including joint with nut bolt, washers, rubber or fiber board gasket, etc testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes :- \n | | | |
|---|
| 11 | 6.01 | 150 mm complete all as specified and as directed. | (a) 150 mm | 4 | Each |
|---|
| 12 | 6.02 | 250 mm complete all as specified and as directed. | (b) 250 mm | 1 | Each |
|---|
| 13 | 7 | Supply and fixing cast iron foot valve flanged end and swing type operating with rubber seat as per IS 4038 fixed to UG sump pipe 150 mm dia including joint with necessary fittings as required at site, including taking down old one complete all as specified and as directed. | Supply and fixing Cast iron foot valve flanged end and swing type operating with rubber seat as per IS 4038 fixed to UG sump pipe 150 mm dia including joint with necessary fittings as required at site , including taking down old one complete all as specified and directed. | 2 | Each |
|---|
| 14 | 8 | Supply and fixing cast iron double orifice air release valve ISI marked IS 14845 type DS2 in PN 1.0 flanged end with provision for inbuilt isolating valve to the existing pipe line including joint with necessary fittings as required at site, testing complete all as specified and as directed including taking down old one complete suitable for the following bore of pipes :- | Supply and fixing Cast iron Double orifice Air release valve ISI marked IS 14845 type DS2 in PN 1.0 flanged end with provision for inbuilt isolating valve to the existing pipe line including joint with necessary fittings as required at site , testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes :- | | |
|---|
| 15 | 8.01 | 50 mm dia complete all as specified and as directed. | (a) 50 mm dia | 2 | Each |
|---|
| 16 | 8.02 | 100 mm dia complete all as specified and as directed. | (b) 100 mm dia | 2 | Each |
|---|
| 17 | 8.03 | 150 mm dia complete all as specified and as directed. | (c) 150 mm dia | 1 | Each |
|---|
| 18 | 9 | Labour for repair / rectification of leakage of underground CI / DI pipe line of size 150 to 400 mm bore dia in position complete with excavation appx 1.5 X 1.5 X 1.5 mtr around the leakage, returning, filling in, removal, cutting / dismantling of leakage complete with and including cocking to existing lead joint, filling new lead joint burning and taking out existing lead joint as per site requirement and restore the water supply complete all as specified and as directed.\nNote: Spare / fitting shall be measured and paid separately.\n | Labour for repair/rectification of leakage of underground CI/DI pipe line of size 150 to 400 mm bore dia in position complete with excavation Appx 1.5X1.5X1.5 mtr around the leakage, returning filling in,removal,cutting/dismentaling of leakage complete with and including cocking to existing lead joint,filling new lead joint burning and taking out existing lead joint as per site requirement and restore the water supply.\nNote: (Spare/fitting shall be measured and paid seperatly)\n | 15 | Each Job |
|---|
| 19 | 10 | M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 150 mm bore with new lead complete all as specified and directed.\n | M&L for Run lead joint for CI spigot and socket pipes & fittings of dia 150 mm bore with new lead complete all as specified and directed.\n | 5 | Each |
|---|
| 20 | 11 | M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 200 to 250 mm bore with new lead complete all as specified and as directed.\n | M&L for Run lead joint for CI spigot and socket pipes & fittings of dia 200-250 mm bore with new lead complete all as specified and directed.\n | 5 | Each |
|---|
| 21 | 12 | M&L for Run lead joint for CI spigot and socket pipes and fittings of dia 300 mm bore with new lead complete all as specified and as directed.\n | M&L for Run lead joint for CI spigot and socket pipes & fittings of dia 300 mm bore with new lead complete all as specified and directed.\n | 5 | Each |
|---|
| 22 | 13 | Taking up CI / DI water mains (including all fittings) of dia 100 to 150 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.\n | Taking up CI/DI water mains (including all fittings) of dia 100-150 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and directed by Engr-in-charge\n | 120 | RM |
|---|
| 23 | 14 | Taking up CI / DI / MS water mains (including all fittings) of dia 250 to 300 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and as directed by Engr-in-Charge.\n | Taking up CI/DI/MS water mains (including all fittings) of dia 250-300 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and directed by Engr-in-charge\n | 52 | RM |
|---|
| 24 | 15 | Supply and laying MS Black pipe P/E ISI marked conforming to IS 1239 PART - 1 (2004) of 150 mm dia bore medium grade ('B' Class) with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint and testing complete, duly painted with two coats of bituminous paint externally all as specified and as directed by Engr-in-Charge.\n | Supply and laying MS Black pipe P/E ISI marked conforming to IS 1239 PART -1 (2004) of 150 mm dia bore medium grade (B Class) with flanged joints at both ends as per site requirement in trenches,on ground or on the support above ground level by continuous welding joints 15mm thick flange joint and testing complete, duly painted with two coats of bituminous paint externally all as specified and directed by Engr-in Charge.\n | 120 | RM |
|---|
| 25 | 15.01 | Note: - (a) Rate quoted by the contractor inclusive of necessary arrangement required for fixing of the item.\n(b) Flange joint and flange jointing materials, welding etc shall deemed to be included in the rate quoted rate of pipe.\n(c) During execution of work if any damage to civil bldg, internet cables, electric cables, electric poles, road, nallah. The contractor is fully responsible and repair to damage will be executed by contractor under own arrangements.\n | | | |
|---|
| 26 | 16 | Supply and laying MS Black pipe P/E ISI marked conforming to IS 1239 PART - 1 (2004) of 300 mm dia bore, 5 mm thick with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint and testing complete, duly painted with two coats of bituminous paint externally all as specified and as directed by Engr-in-Charge.\n | | 58 | RM |
|---|
| 27 | 16.01 | Note :- (a) Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item.\n(b) Flange joint and flange jointing materials, welding etc shall deemed to be included in the rate quoted rate of pipe.\n(c) During execution of work if any damage to civil bldg, internet cables, electric cables, electric poles, road, nallah. The contractor is fully responsible and repair to damage will be executed by contractor under own arrangements.\n | | | |
|---|
| 28 | 17 | M&L for MS fititngs such as Bends (any type, radius and angles) bend to required shape by cutting and welding including flanges as required at site and testing complete all as specified and as directed for required size of bore 150 to 300 mm. \n | | 500 | Kg |
|---|
| 29 | 17.01 | MS fittings shall be of same make as of MS pipes or of make as recommended by manufacturers. | (i) MS fittings shall be of same make as of MS pipes or of make as recommended by manufacturers | | |
|---|
| 30 | 17.02 | The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less. | (ii) The weight of the fittings shall be measured and paid as given in relevent IS or actually provided which ever is less | | |
|---|
| 31 | 17.03 | All fittings shall bear relevant IS stamping marking. | (iii) All fittings shall bear relevent IS stamping marking. | | |
|---|
| 32 | 17.04 | Excavation and earth work shall be measured and paid for separately. | (vi) Excavation and earth work shall be measured and paid for separately | | |
|---|
| 33 | 17.05 | Cost of the joints and jointing materials shall be deeemed to be included in the relevant items. | (v) Cost of the joints and jointing materials shall be deeemed to be included in the relvant items . | | |
|---|
| 34 | 18 | Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 150mm dia, such as bends (any type, radius and angle) Tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches \"Y\" junction, double branches cross (all sockets or socket and spigot) collars, caps and plugs etc complete all as specified and as directed.\n | Supply and fixing CI/DI specials for spigot & socketed CI/DI pipes 150mm dia, such as bends(any type, radious and angle) Tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches \"Y\" junction, double branches cross(all sockets or socket and spigot) collars, caps and plugs etc.\n | 120 | Kg |
|---|
| 35 | 19 | Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 150mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged, other end tapering as bell mouth all as specified and directed by Engr-in-Charge. | Supply and fixing CI/DI specials for spigot & socketed CI/DI pipes 150mm ldia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth al as specified and directed by Engr-in-charge. | 90 | Kg |
|---|
| 36 | 20 | Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 200 to 300 mm dia, such as bends (any type, radius and angle) Tapers, any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches \"Y\" junction, double branches cross (all sockets or socket and spigot) collars, caps and plugs etc complete all as specified and as directed.\n | Supply and fixing CI/DI specials for spigot & socketed CI/DI pipes 200 to 300 mm dia, such as bends(any type, radious and angle) Tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches \"Y\" junction, double branches cross(all sockets or socket and spigot) collars, caps and plugs etc.\n | 95 | Kg |
|---|
| 37 | 21 | Supply and fixing CI / DI specials for spigot and socketed CI / DI pipes 200 to 300 mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged, other end tapering as bell mouth complete all as specified and directed by Engr-in-Charge. | Supply and fixing CI/DI specials for spigot & socketed CI/DI pipes 200 to 300 mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth al as specified and directed by Engr-in-charge. | 52 | Kg |
|---|
| 38 | 22 | Construction of brick masonary valve pit chamber of 1050 x 1050 x 1050 mm sizes (internal dimensions) with MS sheet cover 6 mm thick and angle iron 40 x 40 x 6 mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and as directed. \n | Construction of brick masonary valve pit chamber of 1050 x 1050 x 1050 mm sizes (internal dimensions) with MS sheet cover 6 mm thick and angle iron 40 x 40 x 6 mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete \n | 2 | Each |
|---|
| 39 | 23 | Description same as per Ser item No 22.00 here-in-before but 900 x 900 x 900 mm bore complete all as specified and as directed. | All as per item no 22 here-in- before but 900 x 900 x 900 mm bore | 1 | Each |
|---|
| 40 | 24 | Description same as per Ser item No 22.00 here-in-before but 600 x 600 x 600 mm bore complete all as specified and as directed. | All as per item no 22 here-in- before but 600 x 600 x 600 mm bore | 1 | Each |
|---|
| 41 | 25 | NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room.\nNOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE.\nNOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings. | | | |
|---|