Construction Of Brass Cluster Building Kariyatpur Hazaribagh
Tender Overview
Project Description
Construction Of Brass Cluster Building Kariyatpur Hazaribagh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Mar-2021 | date | Date | 27-Mar-2021 |
| 2 | 25-Mar-2021 | COMPLETION DATE | Technical Bid | 27-Mar-2021 |
BOQ
| Name of Work: Construction of Brass Cluster Building, Kariyatpur, Hazaribagh | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. | 180.65 | cum | |
| 2 | 2 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). | 439.98 | cum | |
| 3 | 3 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). | 95.16 | cum | |
| 4 | 4 | Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per | 571.64 | sqm | |
| 5 | 5 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | 29.23 | cum | |
| 6 | 6 | Providing designation 75B brick work with \n in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | 78.17 | cum | |
| 7 | 7 | Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:6) in superstructure with approved quality of clean coarse sand of F.M 2 to 2.5 including the cost of screening, carrige of materials, scaffolding raking out joints to 15 mm depth , curing, taxes and royalty (but excluding the cost of reinforcement ) all complete as per building specification and direction of E.I | 18.18 | sqm | |
| 8 | 8 | Providing P.C.C. M-150 with nominal mix of (1:2:4) in foundation with approved quality of stone metal grade - III (50 mm to 25mm size) clean coarse sand of F.M 2.5 to 3 including screening, shuttering,mixing cement concrete in mixer and placing in position vibrating, skirting, curing, taxes and royalty all complete all complete as per building specification and direction of Engineer-incharge. | 57.16 | cum | |
| 9 | 9 | Providing R.C.C. M-200 with normal mix of (1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I | 43.74 | cum | |
| 10 | 10 | Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | 9.03 | cum | |
| 11 | 11 | Providing R.C.C. M-200 with nominal mix of (1:1.5:3) in lintel with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | 4.07 | cum | |
| 12 | 12 | Providing R.C.C. M-200 in Roof Beam level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | 16.32 | cum | |
| 13 | 13 | Providing R.C.C. M-200 with nominal mix of (1:1½:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | 25.41 | cum | |
| 14 | 14 | Providing av. 63mm thick R.C.C. M-200\n with nominal mix of (1:1.5:3) Chajja with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering and mixing cement concrete in mixer and placing in position, vibrating, striking 6mm cement plaster (1:4) in ceiling and sides of chajja with sand of F.M. 1.5 curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of E/I. | 27.72 | sqm | |
| 15 | 15 | Providing R.C.C.M 200 with nominal mix of (1:2:4) in roof slab with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, stricking, curing, taxes and royality all complete, as per building specification and direction of E/I | 59.74 | cum | |
| 16 | 16 | Providing Toe steel reinforcement of 8mm dia\n to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) | 16.84 | MT | |
| 17 | 17 | Steel work welded in built up M.S Grill sections/ framed work (USE SQUARE BARS), including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.\nIn stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete | 968.76 | kg | |
| 18 | 18 | Supplying, fitting and fixing collapsible gate\n of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. | 17.28 | sqm | |
| 19 | 19 | Providing Promer One coats of red lead paints \n of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. | 71.1 | sqm | |
| 20 | 20 | Providing two coats of synthetic enamel \npaint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. | 71.1 | sqm | |
| 21 | 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at\njunctions, i.e. at top, bottom and sides with required EPDM rubber/\nneoprene gasket etc. Aluminium sections shall be smooth, rust free,\nstraight, mitred and jointed mechanically wherever required including\ncleat angle, Aluminium snap beading for glazing / paneling, C.P.\nbrass / stainless steel screws, all complete as per architectural\ndrawings and the directions of Engineer-in-charge. (Glazing, paneling\nand dash fasteners to be paid for separately) \nPowder coated aluminium (minimum\nthickness of powder coating 50 micron) | 107.64 | kg | |
| 22 | 22 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings\nshall be paid for separately)\nPowder coated aluminium (minimum\nthickness of powder coating 50 micron) | 53.82 | kg | |
| 23 | 23 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .\n(Cost of aluminium snap beading shall be paid in basic item): | 53.82 | sqm | |
| 24 | 24 | Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm | 26.91 | sqm | |
| 25 | 25 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. | 879.08 | sqm | |
| 26 | 26 | Providing 6 mm thick cement plaster ( (1:3) in ceiling with clean corse sand of F.M 1.5 including screnning, curing with all leads and lifts of water scaffolding ,taxes royalty all complete as per building specification and direction of E.I | 429.275 | sqm | |
| 27 | 27 | Providing two coats of snowcem of approved shade and make over a coat of cement primer over new surface including prepairing the plastered surface by rubbing smooth with sand paper scaffolding curing,taxes all complete as per building specification and direction of E.I | 840.565 | sqm | |
| 28 | 28 | Finishing walls with textured exterior paint of required shade :\nNew work (Two or more coats applied @ 3.28 ltr/10 sqm)\nover and including priming coat of exterior primer applied\n@ 2.20kg/10 sqm | 467.79 | sqm | |
| 29 | 29 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded\nstone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm\nnominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement\nslurry, but excluding the cost of nosing of steps etc. complete. | 416.675 | sqm | |
| 30 | 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including\npointing the joints with white cement and matching pigment etc., complete. | 12.6 | sqm | |
| 31 | 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,\nincluding pointing in white cement mixed with pigment of matching shade\ncomplete | 80.55 | sqm | |
| 32 | 32 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes\n110 mm Rain water pipe | 38.4 | mtr. | |
| 33 | 33 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.\nCoupler - 110mm | 16 | Each | |
| 34 | 34 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.\nBend - 110mm | 16 | Each | |
| 35 | 35 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.\nShoe - 110 | 16 | Each | |
| 36 | 36 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete\n110 mm | 24 | Each | |
| 37 | 37 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth. | 55.2 | sqm | |
| 38 | 38 | Carriage of materials\nBricks Lead = 7.+1 km | 62.05 | Thou. | |
| 39 | 39 | Sand lead = 10 km | 154.51 | cum | |
| 40 | 40 | Stone chips lead = 10 km | 137.93 | cum | |
| 41 | 41 | Stone metal lead = 10km | 54.88 | Cum | |
| 42 | 42 | Local Sand lead = 10km | 57.16 | cum | |
| 43 | 43 | SANITARY\nSupplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 liters C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware ware footrest to be fixed than 50 gms, 15mm PVC connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. \nWith 12.5 lit. low level PVC cistern | 3 | Each | |
| 44 | 44 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.\nFlat back or standard corner (600mm x 350mm) | 1 | Each | |
| 45 | 45 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I. | 2 | Each | |
| 46 | 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall \n25 mm nominal outer dia .Pipes. | 15 | RMT | |
| 47 | 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall \n32 mm nominal outer dia. Pipes. | 10 | RMT | |
| 48 | 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall \n40 mm nominal outer dia. Pipes. | 8 | RMT | |
| 49 | 49 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. \n15 mm nominal outer dia .Pipes. | 10 | RMT | |
| 50 | 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. \n20 mm nominal outer dia .Pipes. | 10 | RMT | |
| 51 | 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. \n25 mm nominal outer dia .Pipes. | 15 | RMT | |
| 52 | 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. \n32 mm nominal outer dia .Pipes. | 10 | RMT | |
| 53 | 53 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(d) 32mm dia and weight not less than 700gms. | 1 | Each | |
| 54 | 54 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(e) 40mm dia and weight not less than 1.0 Kg.. | 1 | Each | |
| 55 | 55 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.\n(f) 50mm dia and weight not less than 1.5 Kg. | 1 | Each | |
| 56 | 56 | Providing and fixing Male ended 15mm dia brass bib cock of approved quality (Wt. Not less than 350 gms) with extra socket all complete as per specification and direction of E/I. : | 2 | Each | |
| 57 | 57 | Providing and fixing brass/C.I stop cock of approved quality all complete as per specification and direction of E/I.\n15mm nominal bore | 2 | Each | |
| 58 | 58 | Providing and fixing 15mm size C.P. brass pillar cock (Weight not less than 350gms). C.I. body brass spindle pillar cock of approved quality as per specification and direction of Engineer-in-Charge.\n(b) C.I. body brass spindle | 2 | Each | |
| 59 | 59 | Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system | 1000 | Lit | |
| 60 | 60 | Providing and fixing PTMT grating of approved quality and colour.Circular type\n100 mm nominal dia | 2 | Each | |
| 61 | 61 | Providing and fixing PTMT grating of approved quality and colour.Circular type\n125 mm nominal dia with 25 mm waste hole | 15 | Each | |
| 62 | 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. \n110 mm diameter | 15 | RMT | |
| 63 | 63 | ELECTRICAL \nPoint wiring in PVC conduit, with modular type switch - \nPoint wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.\nGroup - B | 40 | P/Point | |
| 64 | 64 | Wiring for twin control light point with 1.5 sq.mm \nFRPVC insulated copper conductor single/core cable in surface/recessed PVC conduit 2 way piano type switch phenolic laminated sheet cover suitable size M.S. box and earthing the paint with 1.5 sq.mm FRPVC | 4 | Each | |
| 65 | 65 | Wiring for light/power plug with 2 x 4 sq.mm FRPVC insulated\n copper conductor single core cable in surface/recessed PVC conduit along with 1 No. sq.mm FRPVC insulated copper conductor single core cable for loop earthing as required | 80 | Mtr. | |
| 66 | 66 | Wiring for Curcuit submain wiring along with earth\n wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required\n2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire | 125 | Per Mtr. | |
| 67 | 67 | Wiring for Curcuit submain wiring along with earth\n wire with the following sizes of PVC insulated copper conductor single core cable in surface of recessed PVC sonduit as required\n2 x 4.0 sq.mm. + 1 x 4.0 sq.mm. earth wire | 65 | Per Mtr. | |
| 68 | 68 | S/F PVC conduit - \nSupplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.\n20mm | 45 | Per Mtr. | |
| 69 | 69 | S/F PVC /G.I. boxes - \nSupplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.\n75mm x 75mm x 50mm deep/(4\" x 4\") | 24 | Each | |
| 70 | 70 | Telephone wiring in existing conduit - \nSupplying and drawing following pair, 0.5 sq.mm FR PVC copper conductor, unarmoured telephone cable in the existing surface/recessed PVC conduit as required.\n2 Pair | 80 | Per Mtr. | |
| 71 | 71 | TV cable in existing conduit - \nSupplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required. | 80 | Mtr. | |
| 72 | 72 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required5/6 amp. Switch & 3 pin 5/6 amp. Socket/outlet | 19 | Each | |
| 73 | 73 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as required3 pin 5/6 amp. Socket/outlet | 20 | Each | |
| 74 | 74 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as requiredTelephone socket outlet | 4 | Each | |
| 75 | 75 | S/F Modular type switch/socket on the existing switch\n box including connection etc. as requiredTV antenna socket outlet | 4 | Each | |
| 76 | 76 | S/F Modular type electronic fan regulator -\nSupplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 20 | Each | |
| 77 | 77 | S/F suitable size G.I. box with modular plate and cover \nin front on surface or in recess including P.F. 3 pin 5/6 amp. Modular socket outlet and 5/6 amp. Modular switch connection painting etc. as required | 12 | Each | |
| 78 | 78 | S/F suitable size G.I. box with modular plate and\n cover in front on surface/recess including P/F 6 pin 15/16 amp. And 5/6 amp modular socket outlet and 15/16 amps. Modular switch connection as painting etc. as required | 16 | Each | |
| 79 | 79 | S/F 3 pin 5 amp ceiling rose on the existing junction \nbox wooden block including connection etc. as required | 24 | Each | |
| 80 | 80 | S/F brass vatton/Angle Holder including connection etc. as required | 30 | Each | |
| 81 | 81 | S/F Dingdong call bel - \nSupplying and fixing dingdong call bell suitable for D.C/A.C single phase, 2230 volts, complete as required. | 1 | Each | |
| 82 | 82 | ITC fluorescent fitting directly on surface - \nInstalltion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit. | 40 | Each | |
| 83 | 83 | I.T.C of ceiling fan including wiring the down rods of\nstandard length (Up to 30 cm) with 1.5 sq.mm FRPVC with 1.5 sq.mm. FRPVC insulated copper conductor single core cable etc. as required | 10 | Each | |
| 84 | 84 | I.T.C of exhaust fan up to 450mm sweep in the existing \nopening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc. as required | 4 | Each | |
| 85 | 85 | S/F T.P. MCB DB - \nSupplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, Horizontal type | 4 | Each | |
| 86 | 86 | S/F T.P. MCB DB - \nSupplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door, Horizontal type | 3 | Each | |
| 87 | 87 | S/F 5 amp. To 32 amp rating 240 volt \"C\" series miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc. as required.\n6/32 amps, single pole, \"B\" series | 3 | Each | |
| 88 | 88 | S/F 'C' series, MCB - \nSupplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.40 amps, TPN | 6 | Each | |
| 89 | 89 | S/F 'C' series, MCB - \nSupplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.50/63 amps, TPN | 2 | Each | |
| 90 | 90 | S/F following rating single pole 240 volts isolator in the\n existing MCB DB complete with connection testing and commissioning etc. a srequired40 amp | 3 | Each | |
| 91 | 91 | S/F following rating single pole 240 volts isolator in the\n existing MCB DB complete with connection testing and commissioning etc. a srequired63 amp | 4 | Each | |
| 92 | 92 | Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia \nincluding accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. | 1 | P/Set | |
| 93 | 93 | Copper earth plate elecrtode - \nEarthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But without charcoal or coke and salt) | 1 | P/Set | |
| 94 | 94 | Salt/Charcoal for plate earth electrode - \nExtra for using salt and charcoal for G.I. or copper plate earth electrode as required. | 1 | P/Set | |
| 95 | 95 | S/L 8 SWG copper wire at 0.50 metre below ground level\nfor conductor earth electrode including soldering etc. as required | 30 | Mtr. | |
| 96 | 96 | P/F lighting conductor final made of 25mm dia 30omm\n long copper tube having single pole at top with 85mm dia 3mm thick copper base plate including holes etc. complete as required | 1 | Each | |
| 97 | 97 | Reverting sweating and soldering of copper/G.I. tape (with another\ncopper G.I. tape base of the final or any other metalic object) as required | 30 | Mtr. | |
| 98 | 98 | P/F copper lightning conductor tape in horizontal run - \nProviding and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) | 22 | Mtr. | |
| 99 | 99 | P/F copper lighning conductor tape in vertical run - \nProviding and fixing copper tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) | 15 | Mtr. | |
| 100 | 100 | P/F testing joint made of 20 x 3mm thick copper strip\n 125mm long with 4 nos. of tinned brass bolts nuts check nuts and spring washers etc. complete as required | 1 | Each | |
| 101 | 101 | MV Cable Laying upto120 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. | 20 | Mtr. | |
| 102 | 102 | MV Cable Laying upto400 Sq mm in ground:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc, as required. | 20 | Mtr. | |
| 103 | 103 | Supply 1200mm ceiling fan Bajaj/cromption or any other approved\nmake etc. without regulator | 20 | Each | |
| 104 | 104 | S/F 18 watt LED | 20 | Each | |
| 105 | 105 | 1X28 watt T5 Tube light fitting | 10 | Nos. | |
| 106 | 106 | Supply 12\" dia Khaitan India exhaust fan etc. all required | 6 | Each | |
| 107 | 107 | BORING \nCost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.\n(a) From 0.00 M to 50.00 M below G.L. | 50 | M | |
| 108 | 108 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.\n(b) From 51.0 M to125.00 M | 75 | M | |
| 109 | 109 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(c) From126.0 M to250.00 M | 25 | M | |
| 110 | 110 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.\n200 mm nominal size dia | 50 | M | |
| 111 | 111 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge | 2 | Hours | |
| 112 | 112 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:\n200 mm dia | 2 | Each | |
| 113 | 113 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.\n200 mm clamp | 2 | Each | |
| 114 | 114 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.\nSubmersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages\n2 HP | 1 | Each | |
| 115 | 115 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I. | 1 | Each | |
| 116 | 116 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. | 160 | M | |
| 117 | 117 | Supply fitting and fixing lowering 50 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. | 160 | M | |
| 118 | 118 | SEPTIC TANK (3.5MX2.1MX2.1M)\nEarth work in EXCAVATION in foundation trenches in ordinary so il (vide classification of soil item -A) and disposal of excavation earth as obtained --------do----\n | 17.25 | cum | |
| 119 | 119 | EARTH FILLING in foundation trenches And plinth in layers not exceeding 150 mm Thick well watered rammed, ---------do-------- | 17.25 | cum | |
| 120 | 120 | Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding -----do----\n | 0.82 | cum | |
| 121 | 121 | Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royality all complete as per building-----do-----\n | 8.21 | sqm | |
| 122 | 122 | Providing P.C.C. M- 150 with nominal mix (1:312:3) in foundation & plinth with approved quality of stone metal grade-III (50mm to 25mm size) clean -----do----\n | 0.82 | cum | |
| 123 | 123 | Providing designation 75B brick work in C.M (1:10) in foundation and plinth – do -\n | 5.54 | cum | |
| 124 | 124 | Providing R.C.C . M-200 with nominal mix of (1:1*1/2:3) in \nRoof slab with ----do----\n | 0.74 | cum | |
| 125 | 125 | Providing R.C.C. M-200 with nominal mix (1:1.5:3) IN\n ROOF BEAM with approved quality of stone chips 20 mm to 6 mm size grade and clean course-----do----\n | 0.04 | cum | |
| 126 | 126 | Providing cost of Reinforcement Bar 8 mm, 10mm ………..do……...\n | 0.07 | MT | |
| 127 | 127 | Providing 12mm plaster (1:3) with water Proof \nmaterial\n | 11.1 | sqm | |
| 128 | 128 | providing 1.5mm cement punning including caring carriage of water with all lead \n | 11.1 | sqm | |
| 129 | 129 | Providing C l+ wo Cl Manhole=2' dia 600x450mm-39.00kg\n | 3 | each | |
| 130 | 130 | Making soak pit 2.5 m diameter3.0 \nmetre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. | 1 | each | |
| 131 | 131 | Carriage of Materials | 1 | L.S. | |
| 132 | 132 | GST @12% | 0.12 | percentage | |
| 133 | 133 | 1% Labour Cess | 0.01 | percentage |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender