Educational and Research Institute Local Bodies Closing in 0 days TDR #27353607

Repair And Renovation Of Room No 57A Repair And Renovation Of Room No 2 , 3 , 57 ( A ) , 57 ( B ) And 57 ( C ) At Kashmere Gate Campus Of Dr . B . R . Ambedkar University Delhi , Delhi -110006

Issued by Local Bodies · Ambedkar University Delhi, Lothian Road, Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Apr 2021
0 days left
EMD
32500
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambedkar University Delhi, Lothian Road, Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Renovation Of Room No 57A Repair And Renovation Of Room No 2 , 3 , 57 ( A ) , 57 ( B ) And 57 ( C ) At Kashmere Gate Campus Of Dr . B . R . Ambedkar University Delhi , Delhi -110006

BOQ

Name of Work: Repair and Renovation of Room No 2, 3, 57A, 57B, 57C at Kashmere Gate Campus of Dr. B R Ambedkar University Delhi, Delhi-110006 .
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11CIVILBI01010001010000000000000515BI0100001112
21.01Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazingand false ceiling including disposal of unserviceable surplus material andstacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.BI01010001010000000000000515BI0100001113187.83sqm
31.02Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and belowBI01010001010000000000000515BI010000111415.84Each
41.03Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.BI01010001010000000000000515BI0100001114336.5sqm
51.04CEMENT PLASTER (IN COARSE SAND): 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)BI01010001010000000000000515BI0100001114404.5sqm
61.05Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.\nBI01010001010000000000000515BI0100001114404.5sqm
71.06Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.\nBI01010001010000000000000515BI0100001114404.5sqm
81.07Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coatsBI01010001010000000000000515BI0100001114404.5sqm
91.08Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mmBI01010001010000000000000515BI010000111457sqm
101.09Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.BI01010001010000000000000515BI0100001114179.61sqm
111.1Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading allround the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in- Charge (Cost of 'U' beading and hinges will be paid for separately). 25 mm thickBI01010001010000000000000515BI01000011147.92sqm
121.11Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge.BI01010001010000000000000515BI010000111421.84kg
131.12Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm widthBI01010001010000000000000515BI010000111416.8metre
141.13Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)BI01010001010000000000000515BI010000111457.24kg
151.14Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.BI01010001010000000000000515BI01000011145Each
161.15Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 75x63x4 mmBI01010001010000000000000515BI010000111440Each
171.16Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mmBI01010001010000000000000515BI010000111410Each
181.17Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mmBI01010001010000000000000515BI01000011145Each
191.18Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mmBI01010001010000000000000515BI010000111420Each
201.19Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopperBI01010001010000000000000515BI010000111410Each
211.2Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.BI01010001010000000000000515BI0100001114271.2sqm
221.21Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)9.04Cum
231.22Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.37.16sqm
241.23Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)73sqm
251.24Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .\n(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)15sqm
261.25Carefully removing existing water proofing plaster of thickness up to 25mm from cement based waterproofing treatment on the terrace including dressing and stacking the rubish within 50 mtr lead.271.2sqm
271.26Providing and laying water proofing cement plaster treatment over terrace consisting of following applications:\n\n(A) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.\n\n(B) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel as per direction by Engineer-in-charge.271.2sqm
281.27Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge on walls, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete37.2sqm
291.28Providing and laying 25mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :54.6sqm
302Electrical
312.01Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wireBI01010001010000000000000515BI010000111440metre
322.02Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mmBI01010001010000000000000515BI0100001114150metre
332.03Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch\n21Each
342.04Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet\n21Each
352.05Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 1 or 2 Module (75mmX75mm)32Each
362.06Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 3 Module (200mmX75mm)21Each
372.07Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable75metre
382.08Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required.9Each
392.09Supplying and fixing of RJ 45 CAT 6 information outlet (I/O) for data, voice rack end complete with feruling and end termination as required.(Make:-(Belden/Legrand-Myrius/MK/Schnider/Crabtree)32Each
402.1Supplying and installing following size Snap on trunking DLP along with accessories on surface. (50 x 105 mm)50metre
412.11Supplying, Installation, Testing and Commisioning of recessed Mounted ultraslim LED fixture flat panel 2' x 2' made of fabricated CRCA sheet steel housing duly powder coated with high efficient LEDs & glare free opal diffuser IP 20, min 36 watt complete in false ceiling with driver (constant current and constant voltage) complete in every way as required. (Halonix CAT Ref. No. HLFPR22-02-36-CW-R or its equivalent)9Each
422.12Removing/ Relocation/ Installation of existing split type air conditioning unit up to 2 TR capacity and providing MS supporting stand, power cable of 3 core x 2.5 Sq. mm, refrigerant copper piping of 5/8” and 1/4” size with 9 mm thick insulation and 25mm PVC drain pipe upto 4 metres, gas charging etc. for the split AC unit complete in all respects.\n1Each
432.13Supplying, Installation, testing and commissioning of wall fan of 400mm sweep oscilating type, having plastic blade and TOP (Thermal Overload Protector) complete with all acesseories such as front cage and connection as required. [Halonix CAT Ref. Krypton (High Speed Fan) or its equivalent].18Each

AI Tender Summary

OUR REF NO 27353607
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 06-04-2021
Authority
Authority Name Ambedkar University Delhi
Work Description Repair And Renovation Of Room No 57A Repair And Renovation Of Room No 2 , 3 , 57 ( A ) , 57 ( B ) And 57 ( C ) At Kashmere Gate Campus Of Dr . B . R . Ambedkar University Delhi , Delhi -110006
Basic Detail
Tender No 09/EE/EMU/AUD/2020-21
Bidding Type Tender
Location
City Ambedkar University Delhi, Lothian Road, Delhi
State Delhi
Key Dates
Publish Date 15 Mar 2021
Submission Date 06 Apr 2021
Open Date 06 Apr 2021
Finance
Tender Value Ref. Documents
Tender Fee 590
EMD 32500
Exemption Not Available
Document List
A511EDFC-38B9-4498-B87A-95844F88B9A7.html
BOQ_255862.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 15, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 06, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 06, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

A511EDFC-38B9-4498-B87A-95844F88B9A7.html

xls

BOQ_255862.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender