| 1 | 1 | M&L Taking down Street/Perimeter Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. | BI01010001010000000000000515BI0100001113 | 400 | EACH JOB |
|---|
| 2 | 2 | Supply only Tube/Rod 1x14 Watt (as approved) suitable for T-5 Light Fitting 4x14 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001114 | 200 | EACH |
|---|
| 3 | 3 | Supply only Electronic Ballast 2x14 Watt (as approved) suitable for T-5 Fitting 4x14 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001115 | 50 | EACH |
|---|
| 4 | 4 | Supply only PVC Holder (as approved) suitable for T-5 Fitting, 4x14 Watt complete all as specified and as directed. | BI01010001010000000000000515BI0100001116 | 50 | EACH |
|---|
| 5 | 5 | Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001117 | 20 | EACH |
|---|
| 6 | 6 | Supply only Driver (as approved) suitable for LED Street Light Fitting 45 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001118 | 30 | EACH |
|---|
| 7 | 7 | Supply only Driver (as approved) suitable for LED Street Light Fitting 48 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001119 | 30 | EACH |
|---|
| 8 | 8 | Supply only Driver (as approved) suitable for LED Street Light Fitting 60 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001120 | 20 | EACH |
|---|
| 9 | 9 | M&L Lowering down High Mast Lights, Repairing High Mast Light by apply Greasing, Oiling, etc., Repairing as required, Re-hoisting High Mast Lights after Repaired including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'. | BI01010001010000000000000515BI0100001121 | 6 | EACH JOB |
|---|
| 10 | 10 | Supply only Driver (as approved) suitable for LED Flood Light Fitting 120 Watt, complete all as specified and as directed. | BI01010001010000000000000515BI0100001122 | 10 | EACH |
|---|
| 11 | 11 | Supply only LED Flood Light 1x120 Watt (as approved), complete all as specified and as directed. | BI01010001010000000000000515BI0100001123 | 9 | EACH |
|---|
| 12 | 12 | M&L Taking down Solar Light Fitting of any type and any capacity from any Height, Replacing Defective/ Unserviceable Spares/ Parts, Applying Mineral Jelly to the Battery Terminal(s), Tightening of All Connections, Cleaning of Solar Panel throughly, Filling Distilled Water to Solar Light Batteries, Re-fixing the Solar Light Fitting in Original Position, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional), Distilled Water, etc. will be Measured and Paid separately under respective Items as 'Supply only' | BI01010001010000000000000515BI0100001124 | 34 | EACH JOB |
|---|
| 13 | 13 | Supply only Tinned/ Copper Battery Terminal (as approved), complete all as specified and as directed. | BI01010001010000000000000515BI0100001125 | 10 | EACH |
|---|
| 14 | 14 | Supply only Solar Battery 12 Volt, 75 AH, Dry Gel (as approved) suitable for 3 Days Backup capacity, complete all as specified and as directed. | BI01010001010000000000000515BI0100001126 | 5 | EACH |
|---|
| 15 | 15 | Supply only Distilled Water suitable for Solar Light Batteries, complete all as specified and as directed. | BI01010001010000000000000515BI0100001127 | 48 | LITRE |
|---|
| 16 | 16 | S&F LED Street Light Fitting 30 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS | BI01010001010000000000000515BI0100001128 | 20 | EACH |
|---|
| 17 | 17 | S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPS | BI01010001010000000000000515BI0100001129 | 21 | EACH |
|---|
| 18 | 18 | S&F BAMBOO Light Fitting, New Generation, Environmental Friendly, Energy Saving, Long Life, Aesthetically Designed, Aluminium Landscape Luminaire for Diffused Lighting with High Power LED as Light Source, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0 M) or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GE | BI01010001010000000000000515BI0100001130 | 10 | EACH |
|---|
| 19 | 19 | S&F RUBY (CLEAR), New Generation, Post Top, New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. RUBYPT25WLED757PSYMTOPC or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GE | BI01010001010000000000000515BI0100001131 | 10 | EACH |
|---|
| 20 | 20 | S&F MOON (PRISMAT IC) Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 8 Watt/ 14 Watt (TU)/ LED Lamp B-22 Base Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. LHFXBON1TN6F023 or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GE | BI01010001010000000000000515BI0100001132 | 60 | EACH |
|---|
| 21 | 21 | S&F GRACE Small Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 20 Watt Spiral/ 10 Watt LED Bulb with B-22 Base, having Mounting Pole Dia - 60mm (Max) OD, Width: 160mm & Height : 284mm, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. LHFHASN1TL4K015 or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GE | BI01010001010000000000000515BI0100001133 | 12 | EACH |
|---|
| 22 | 22 | S&F PVC insulated Aluminium Wire 1.5 Sqmm, 3 Core for Providing Connection from Overhead Line to Street Light Fitting including Taking down Unserviceable Wire of any description, complete all as specified and as directed. | BI01010001010000000000000515BI0100001134 | 200 | RUNNING METRE |
|---|
| 23 | 23 | Dismantling Unserviceable LT Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed.\nNOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately. | BI01010001010000000000000515BI0100001135 | 5 | EACH JOB |
|---|
| 24 | 24 | Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001136 | 0.5 | QUINTAL |
|---|
| 25 | 25 | Taking down Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any size from LT Electric Poles of any size and capacity, complete all as specified and as directed. | BI01010001010000000000000515BI0100001137 | 1 | QUINTAL |
|---|
| 26 | 26 | Taking down ACSR Conductor of any size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed. | BI01010001010000000000000515BI0100001138 | 0.5 | QUINTAL |
|---|
| 27 | 27 | Dismantling Stay Assembly complete of any description, complete all as specified and as directed.\nNOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately | BI01010001010000000000000515BI0100001139 | 5 | EACH SET |
|---|
| 28 | 28 | Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed.\nNOTE : Necessary Earth Works will be Measured & Paid under appropriate Items. | BI01010001010000000000000515BI0100001140 | 650 | RUNNING METRE |
|---|
| 29 | 29 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001141 | 230 | CUBIC METRE |
|---|
| 30 | 30 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001142 | 0.3 | CUBIC METRE |
|---|
| 31 | 31 | Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001143 | 190 | CUBIC METRE |
|---|
| 32 | 32 | Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed. | BI01010001010000000000000515BI0100001144 | 30.3 | CUBIC METRE |
|---|
| 33 | 33 | Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed. | BI01010001010000000000000515BI0100001145 | 20 | RUNNING METRE |
|---|
| 34 | 34 | M&L Cutting Existing Road not exc. 1.50 Metre in depth and not exc. 1.50 Metre wide including Making Good the same to match the Original Surface level with Cement Concrete after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed.\nNOTE : Cement Concrete will be Measured and Paid separtely under appropriate Item. | BI01010001010000000000000515BI0100001146 | 20 | RUNNING METRE |
|---|
| 35 | 35 | M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed. | BI01010001010000000000000515BI0100001147 | 0.2 | CUBIC METRE |
|---|
| 36 | 36 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed. | BI01010001010000000000000515BI0100001148 | 5 | CUBIC METRE |
|---|
| 37 | 37 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed. | BI01010001010000000000000515BI0100001149 | 15 | CUBIC METRE |
|---|
| 38 | 38 | M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed.\nNOTE : Necessary Earth Work & Cement Concrete will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001150 | 5 | EACH JOB |
|---|
| 39 | 39 | M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed. | BI01010001010000000000000515BI0100001151 | 0.5 | QUINTAL |
|---|
| 40 | 40 | S&F Insulator Pin type, 100mm height, 65mm dia Porcelain, Vitreous, White, Brown or Green for 1100 Volt grade including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator, complete all as specified and as directed. | BI01010001010000000000000515BI0100001152 | 10 | EACH |
|---|
| 41 | 41 | S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed. | BI01010001010000000000000515BI0100001153 | 10 | EACH |
|---|
| 42 | 42 | S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed. | BI01010001010000000000000515BI0100001154 | 2 | EACH |
|---|
| 43 | 43 | M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed. | BI01010001010000000000000515BI0100001155 | 1 | QUINTAL |
|---|
| 44 | 44 | M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed.\nNOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge. | BI01010001010000000000000515BI0100001156 | 0.5 | QUINTAL |
|---|
| 45 | 45 | M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire, Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.\nNOTE :-\n(a) The above Work includes Cleaning/Tremming of Tree Branches of any dia falling around the ACSR Conductors.\n(b) One Length shall be measured for complete Span comprising of any numbers of ACSR Conductor(s) & GI Wire(s). | BI01010001010000000000000515BI0100001157 | 100 | EACH SPAN |
|---|
| 46 | 46 | S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed. | BI01010001010000000000000515BI0100001158 | 100 | EACH |
|---|
| 47 | 47 | M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed.\nNOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items. | BI01010001010000000000000515BI0100001159 | 5 | EACH SET |
|---|
| 48 | 48 | M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.00 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed. | BI01010001010000000000000515BI0100001160 | 150 | EACH SPAN |
|---|
| 49 | 49 | M&L Painting LT Pre-stressed Concrete Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with Two coats of Cement Based Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.50 Metre height above Ground Level, complete all as specified and as directed. | BI01010001010000000000000515BI0100001161 | 100 | EACH JOB |
|---|
| 50 | 50 | M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.50 Metre height above Ground Level, complete all as specified and as directed. | BI01010001010000000000000515BI0100001162 | 100 | EACH JOB |
|---|
| 51 | 51 | M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001163 | 300 | RUNNING METRE |
|---|
| 52 | 52 | M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 25 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001164 | 100 | RUNNING METRE |
|---|
| 53 | 53 | M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001165 | 150 | RUNNING METRE |
|---|
| 54 | 54 | M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 185 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001166 | 100 | RUNNING METRE |
|---|
| 55 | 55 | Taking down unserviceable LT Cable Cross-sectional area 6 Sqmm 2 Core to 16 Sqmm 2 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001167 | 100 | RUNNING METRE |
|---|
| 56 | 56 | Taking down unserviceable LT Cable Cross-sectional area 10 Sqmm 4 Core to 25 Sqmm 4 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001168 | 100 | RUNNING METRE |
|---|
| 57 | 57 | Taking down unserviceable LT Cable Cross-sectional area 35 Sqmm 3½ Core to 70 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001169 | 100 | RUNNING METRE |
|---|
| 58 | 58 | Taking down unserviceable LT Cable Cross-sectional area 120 Sqmm 3½ Core to 185 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items. | BI01010001010000000000000515BI0100001170 | 100 | RUNNING METRE |
|---|
| 59 | 59 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.\nNOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. | BI01010001010000000000000515BI0100001171 | 70 | CUBIC METRE |
|---|
| 60 | 60 | Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed. | BI01010001010000000000000515BI0100001172 | 4300 | EACH |
|---|
| 61 | 61 | M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001173 | 20 | RUNNING METRE |
|---|
| 62 | 62 | M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001174 | 20 | RUNNING METRE |
|---|
| 63 | 63 | M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. | BI01010001010000000000000515BI0100001175 | 20 | RUNNING METRE |
|---|
| 64 | 64 | S&F MCCB 63 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connections and fixing to Existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed, | BI01010001010000000000000515BI0100001176 | 1 | EACH |
|---|
| 65 | 65 | S&F MCCB 100 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connections and fixing to Existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed, | BI01010001010000000000000515BI0100001177 | 1 | EACH |
|---|
| 66 | 66 | S&F On Load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed. | BI01010001010000000000000515BI0100001178 | 1 | EACH |
|---|
| 67 | 67 | Supply, Installation, Commissioning & Testing Factory made LT Feeder Pillar Box of size 1200x1000x450mm, made out of 3.15mm thick CRCA Sheet, Outdoor Type, Platform mounted, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz, supply having Aluminum Bus-bar 300 Amp for Phase and Neutral, installed on Porcelain/Epoxy Insulator, Dust and Vermin Proof (IP54), Painted with Two Coats of Sysnthetic Enamel Paint, Self mounted type with Mild Steel angle Iron 50x50x6.0mm Frame on front and Rear Opening with Double Shutter having Locking Arrangements with Mild Steel Lock 50mm in size, complete with Fixing Arrangements viz Mild Steel Bolts, Nuts, Washers, etc. and grouting of LT Feeder Pillar Box/ Panel in Cement Concrete 1:2:4 (20mm graded Stone Aggregates) Work, comprising of with the followings including Taking down unserviceable/ rusted Sheet Metal Encloser/ Bus-bar :-\n(a) Copper Bus-bar 4 Strip 300 Amp, 415 Volt - 01 Set\n(b) Space for fixing MCCB 100 Amp, 4 Pole, 35 kA, 415 Volt - 02 No. | BI01010001010000000000000515BI0100001179 | 2 | EACH JOB |
|---|
| 68 | 68 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing, complete all as per specified and as directed. | BI01010001010000000000000515BI0100001180 | 10 | EACH SET |
|---|
| 69 | 69 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing, complete all as per specified and as directed. \nNOTE : All Joints should be joined by Exothermic Welding or Brazing. | BI01010001010000000000000515BI0100001181 | 10 | EACH SET |
|---|